Loading...

Kinetic Model

The shrimp and the platinum character riding a roller coaster together at a funfair

Kinetic Model

← Back to Model

Initial Setup

When performing wet lab setup, the inputs will align with the plan. However, for the initial model results, a basic setup will be used instead.

S0=1g/L

This applies to both models, meaning the initial chitin and chitosan concentration is 1g/L.

For the enzyme inputs, slightly more nuance is needed. The model operates in molar concentrations (mM), though for the life cycle assessment and techno-economic models, it is far more useful to have enzyme input in mass concentrations (g/L). As such, using the expected molecular weights (kDa) from our Benchling, conversions can be made.

E0[mM]=E0[g/L]MW(kDA)(30)

Equation 30 uses the following values:

MWChi=62kDa
MWCDA=49kDa
MWPp=53kDa

The initial concentrations of SmChiA and VcCDA were set on the basis of obtaining 1μM each, acquiring a 1:1 molar ratio.

E0,Chi=0.062g/L
E0,CDA=0.049g/L

This comes to a total enzyme concentration of 0.111g/L. As such, this value was used for the PpChi model.

E0,Pp=0.111g/L

Additionally, the pH (fusion only), temperature, and thermal degradation functions will all be set to active whilst the impact of impurities will be set to inactive (in other words, D=0).

For PpChi, degree of acetylation was set to 0.25 as the chitosan substrate purchased by the wet lab team has that same value.

Optimal Conditions

A parameter sweep is a process that reruns different values of parameters. This enables the most optimal values of parameters to be found based on the time taken to reach 50% and 90% substrate conversion to product. A shorter time generally means a more optimal reaction.

There are four possible parameter sweeps that can be run using the kinetic model to determine optimal operation conditions: temperature for SmChiA, VcCDA, and PpChi, as well as both temperature and pH for the fusion enzyme. Note that pH does not need to be swept for any of the isolated single enzymes due to there being no reason not to select the optimums seen in literature [1] [2] [3].

Figures 15–18

Time taken to reach 50%/90% substrate conversion by PpChi at different temperature values.
Figure 15: Time taken to reach 50%/90% substrate conversion by PpChi at different temperature values.

pH is 6.0. The dots represent the minimum time value, and therefore the optimum temperature value, being 45°C for 90% conversion.

Time taken to reach 50%/90% substrate conversion by SmChiA at different temperature values.
Figure 16: Time taken to reach 50%/90% substrate conversion by SmChiA at different temperature values.

pH is 6.0. The dots represent the minimum time value, and therefore the optimum temperature value, being 43°C for 90% conversion.

Time taken to reach 50%/90% substrate conversion by VcCDA at different temperature values.
Figure 17: Time taken to reach 50%/90% substrate conversion by VcCDA at different temperature values.

pH is 7.0. The dots represent the minimum time value, and therefore the optimum temperature value, being 39°C for 90% conversion.

Time taken to reach 50%/90% substrate conversion by the fusion enzyme at different temperature and pH values.
Figure 18: Time taken to reach 50%/90% substrate conversion by the fusion enzyme at different temperature and pH values.

The dots represent the minimum time value, and therefore the optimum values, being 43°C and pH 6.1 for 90% conversion. The colours used are from the Okabe-Ito palette for better visualisation by the colour blind. Darker colours represent a lower time taken to conversion.

Figures 15-18 are useful as they will be used to determine how the assays will be run in the wet lab. Additionally, Figure 18 highlights how the fusion optimum is much more heavily weighted towards SmChiA than VcCDA. This is seen again when looking at the active quantity of each enzyme subunit of the fusion at the combined optimum (Figure 19).

Active SmChiA and VcCDA subunits across the length of the fusion enzyme’s process at its optimal temperature.
Figure 19: Active SmChiA and VcCDA subunits across the length of the fusion enzyme’s process at its optimal temperature.

Fusion vs Dual-Enzyme vs PpChi

Another very important purpose of the kinetic model is the determination of whether the fusion should be used at all, or if a dual enzyme (SmChiA + VcCDA) system or just PpChi should be used. To begin with, to better understand the conclusions made from Figures 18 and 19, an enzyme molar ratio parameter sweep was done for SmChiA and VcCDA, keeping the total starting enzyme mass constant (Figure 20).

Enzyme ratio parameter sweep.
Figure 20: Enzyme ratio parameter sweep.

Keeping the total enzyme mass input constant at 0.111g/L, the ratio of SmChiA to VcCDA is swept from 0.1 to 40. Looking specifically at 90% conversion, the optimum ratio is 15:1, taking approximately half as long as a 1:1 ratio (the ratio the fusion is confined to). This shows that SmChiA’s action is the rate-limited step.

Now with three figures of evidence (Figures 18, 19 and 20), it is without a doubt that SmChiA is the rate limiting step by an enormous factor, with an optimal ratio of 15:1. For a better overall understanding, Table 9 was made to compare all possible approaches.

Table 9: Comparison of the fusion enzyme, dual enzyme (single-pot), dual enzyme (multi-pot), and PpChi against one another (quantitative).

SystemStarting Enzyme (g/L)Starting SubstrateTemperature (°C)pHTime to 90% conversion (hours)
Fusion0.1111g/L436.12.0480
Dual (single-pot)0.10544 (SmChiA) 0.005556 (VcCDA)1g/L436.11.1714
Dual (multi-pot)0.10544 (SmChiA) 0.005556 (VcCDA)1g/L (SmChiA) 2.21427mM (VcCDA)*43 (SmChiA) 39 (VcCDA)6.0 (SmChiA) 7.0 (VcCDA)1.8359*
PpChi0.1111g/L456.012.6761

* The multi-pot values were calculated by first running SmChiA on its own, recording the intermediate concentration and time taken at 90% conversion, then running VcCDA on its own with the recorded intermediate concentration and noting the time taken to 100% conversion. These times were then summed. The values outlined in “Initial Setup” were used for this table.

Ultimately, Table 9 shows that the single-pot dual-enzyme process is superior to the multi-pot dual-enzyme process whilst also being cheaper (less equipment needed). The main debate can now be summarised as follows:

Table 10: Comparison of the fusion enzyme, dual enzyme (single-pot), and PpChi (qualitative)

SystemRateProduction ComplexityExpressibilityProduct
FusionModerate1 bioprocessNovelWeaker chelator [13]
Dual (single-pot)Fastest2 bioprocessesShown [1] [2]Weaker chelator [13]
PpChiExtremely slow1 bioprocessShown [3]Stronger chelators [13]

As seen in Table 10, all three remaining options have at least one advantage. Using the techno-economic model, a cost comparison on the basis of production complexity can be used to determine whether the dual-enzyme system is more costly. Data from the wet lab can determine whether or not the fusion is expressible and whether or not the product of PpChi is actually superior.

The Effect of Impurities

For use in the techno-economic model and life cycle assessment model, the effect of impurities is of high importance as it determines the number of steps in the downstream processing of the enzymes. From the mass balance, impurity and enzyme yields were obtained. These were then incorporated into the model to give the following results:

Table 11: Impact of the number of unit operations in the downstream processing of the fusion enzyme.

Number of downstream unit operationsEnzyme Concentration (g/L)Impurity concentration (g/L)Product at 10 hours (mM)
50.68412.74811.64
60.65012.36611.44
8 (AEX and UF/DF)0.5801.23722.40
9 (PEG precipitation, TFF, resolubilisation).0.5981.48422.18
10 (AEX, UF/DF, IEX, and UF/DF)0.5060.01223.84

Note: Substrate was set to 10g/L for all tests, enzyme output from fermentation was set to 1kg, and the reaction volume was set to 1000L. Additionally, impurity concentration is the sum of the concentrations of cell debris and HCPs. Also note that operations 1-6 are cell centrifugation, resuspension, homogenisation, flocculation, lysate centrifugation, and depth filtration. Drying has been left out as its inclusion is dependent on business plan, not process efficiency. Temperature was reduced to 30°C to allow VcCDA to last long enough for long reaction times.

The data in Table 11 has been used in the techno-economic model to alter the overall bioprocess flowsheet for cheaper production of the target quantity of enzyme. It has highlighted that using the enzymes without any purification is significantly less productive than with any level of purification. As a result, only the flowsheets with PEG precipitation, a single chromatography step, and two chromatography steps will be compared, using the product values from the kinetic model to determine a localised cost of goods per gram value.

Choice Sensitivity (Partial Sensitivity Study)

The model itself is built on assumptions and partially-available literature data, meaning that it could potentially decrease predictive capabilities depending on choices taken throughout model construction. As such, various alterations have been tested (Tables 12 and 13).

Table 12: Choice sensitivity analysis for the fusion enzyme.

FeatureChangeBaseline time to 90% conversion (hours)Time to 90% conversion (hours)% change from baseline
Temperature impact on turnover number and decaySet to “False”2.04801.6714-18.39
pH impact on turnover numberSet to “False”2.04802.0436-0.21
Decay impact on active enzyme concentrationSet to “False”2.04801.8997-7.24
Product impact on SmChiA’s inhibition termModification of SmChiA rate term to remove monoacetyl chitobiose as an inhibitor2.04800.3031-85.20
Chitobiose impact on VcCDA’s inhibition termModification of VcCDA rate term to include chitobiose as an inhibitor with Ki = 0.286mM [12]2.04802.0648+0.82

Baseline 90% conversion occurs at 2.0480 hours under conditions of 1:1 ratio, 43°C, pH 6.1, total starting enzyme 0.111g/L and starting substrate 1g/L with temperature, pH, and thermal degradation all on.

  • VcCDA inhibition was not used due to very sparse evidence of it even existing, though it has an insignificant effect regardless [12].
  • pH had an insignificant effect due to the optimum fusion pH being very close to SmChiA, the rate limiting enzyme.
  • Decay had a notable effect, as did temperature. It should be noted that the large effect of temperature is also decay, effectively double-counting it.
  • Most impactful was the inclusion of the final product as an inhibitor for SmChiA. This decision was made based purely on the similarity between acetylated and partially-deacetylated chitobiose. The large impact is a result of the fact that the original inhibitor (fully acetylated) is immediately consumed by VcCDA.

Table 13: Choice sensitivity analysis for PpChi.

FeatureChangeTime to 90% conversion% change from baseline
Temperature impact on Kcat and decaySet to “False”12.6762-1.93
Decay impact on ESet to “False”12.7408-1.43
Large shift in G_Pp function to match literature peakSet G_Pp to G_Pp,Offset by subtracting delta (7.18)13.1308+1.59
Random acetylation pattern of substrateSet Y=(1-DA)(1-q)q where q=DA(1-0.5) to achieve halfway blocky acetylation11.9939*-7.21

Baseline 90% conversion occurs at 12.9252 hours under conditions of 43°C (matching fusion), total starting enzyme 0.111g/L, substrate DA 0.25, and starting substrate 1g/L with temperature and thermal degradation all on. *Lower product was originally generated, so the value of starting substrate was modified to achieve the same product generated.

Interestingly, it appears that of the assumptions made for PpChi, only the random substrate acetylation pattern appears to have had a significant effect. This could be due to a lack of literature data making PpChi appear more versatile than it potentially is.

Wet Lab Integration

Fortunately, the pNPA assay showed positive results for VcCDA. However, they could not be analysed to obtain kinetic parameters. The same can be said for the MBTH assay where, similarly to Wageningen_UR (2016), both the standard curve and reaction course data was erratic. As such, wet lab integration was not performed.

Final Conclusions

The kinetic model as a whole has served as a significant asset throughout the project, alongside the techno-economic model, life cycle assessment and wet lab research, in determining the optimal approach to generating a chelating agent for our project.

Firstly, the kinetic model has generated data that will be used in conjunction with other models and wet lab research to determine the optimum enzyme system, being PpChi. This is because PpChi was shown to have greater expression than the fusion and is generally cheaper to use at large scale.

Secondly, the kinetic model has provided a set of baseline values for use by the wet lab when performing their enzyme assays. This includes using 37°C for the VcCDA pNPA assay and using 40°C for the SmChiA/PpChi MBTH assay. The output of this can then be fed back into the model, improving it and producing a superior platform that serves as an interface used in scale up of the SHELLter project.

Thirdly, the kinetic model has provided insight into the impact of impurities on enzymatic rates using the partial techno-economic model. As a result, the industrial production of our selected enzyme has been narrowed down to the following: centrifugation (cell pelleting), resuspension, homogenisation, flocculation, centrifugation, depth filtration, PEG precipitation, tangential flow filtration (slurry retention), and resolubilisation.

Table 14: Overall Summary of Results

GoalResultGoal Achieved
To inform on enzyme selection.Has enabled selection of PpChi through interaction with the mass balance, which in turn informs the techno-economic model and life cycle assessment.YES
To inform on assay protocols.Has enabled selection of assay temperatures for pNPA (37°C) and MBTH (40°C).YES
To inform on the industrial scale plan.Has enabled selection of the PEG precipitation downstream route through interaction with the preliminary mass balance/cost model.YES
To integrate wet lab data for generation of a platform for scale-up of our project.No wet lab data can be implemented. In future, would require repeats of the assays multiple times and without the time constraints of the iGEM deadlines.INCOMPLETE