Hardware

The platinum character holding a wrench and a blueprint of a reactor in a workshop, with books on process design, bioengineering and sustainability and a cisplatin diagram on the whiteboard

Hardware

Overarching Purpose

The focus of our project as a whole is to generate a chelating agent (either mono-acetylated chitobiose or mono-acetylated chitotriose) that can remove heavy metals from wastewater, aiding water treatment facilities and reducing the amount of harmful compounds in natural water bodies. Whilst synthetic biology can be used to create these agents, they must be installed into an overall piece of hardware to actually work. As such, the hardware must meet the following goals:

  • Handle the wastewater passing through or entering it without compromising its structure and functionality.
  • Remove a significant portion of the heavy metal contaminants from the loaded wastewater.
  • Be economically viable and superior to current state-of-the-art hardware.
  • Be easily implementable into current infrastructure.
  • Be safe to operate and maintain, and safe for disposal of heavy metal residues.
  • Have a significant positive impact on the environment.
Figure 1: Final assembly design

The Fusion 360 assembly, consisting of the reusable frame and disposable cartridge (connected) beside the reusable plunger.

Previous Applications

Throughout the project’s development, the application of our hardware changed considerably.

Application 1

Originally, the focus of our project was the development of a large-scale piece of equipment that could clean heavy metals out of industrial and mining wastewater. There were two main ideas for how this could be implemented, though they were not fully explored:

  • A large reactor with dissolved chelating agent, followed by a specialised filter.
  • A large chromatography column that uses the chelating agent as a ligand.

In the former design, reaction between the heavy metals and the chelating agent would create a complex of higher molecular weight that could theoretically be easier to filter. In reality, however, the change in molecular weight is insignificant, being from around 340 Da to around 570 Da. This would require nanofiltration [1], a unit operation that cannot feasibly be done at this scale.

In the latter design, the wastewater would flow continuously through a chromatography column that retains the heavy metal residues. This is significantly more feasible, though it was not fully explored due to a change in application focus.

Application 2

Early into the project, it became known to the team that new EU legislation would be coming into effect that would drastically alter how pharmaceutical waste was handled. This requires pharmaceutical companies to pay 80% of the end-of-life cleanup costs of their products [2], which could potentially sway such companies from supplying their product at all. As proof of concept, cisplatin, a platinum-based chemotherapeutic drug, was selected as the target compound. Cisplatin is important for treatment of solid tumours, though it is cytotoxic and largely excreted by patients through their urine [3].

It must be noted that the potential uses of the chelating agent can still be applied to other areas, such as industrial wastewater treatment (for example using the chromatography idea mentioned above), and should not be limited to just cisplatin removal, as advised by stakeholder Dr Anne Woolridge. In this case, however, the wastewater being treated has changed origin, from industrial activity to hospital sewer systems.

The design ideas for this application are identical to the ones mentioned previously for industrial wastewater treatment, though they would be at a much smaller scale and placed within hospital waste systems, directly before discharge into sewer systems. Whilst this location was deemed optimal by medical stakeholders (Dr Kumud Kantilal and Anne O’Connor and Professor Louis Grandjean), those same stakeholders also informed us of the difficulty in changing the infrastructure of hospitals for a cause that does not save significant amounts of money. As such, it was decided that the application would not be a large-scale piece of equipment integrated into infrastructure, but rather a small device used by patients directly, ensuring that the amount of cisplatin flushed into toilets was reduced altogether.

Design Process

Through both research and stakeholder interaction, many different conceptual designs were thought through. The same story is told cycle by cycle on our Engineering Success page.

Design 1

In the first design, the hardware was effectively just a funnel that could be attached to the toilet. The chelating agent coating the material inside the funnel would bind to the cisplatin, trapping it within the hardware. Meanwhile the treated urine would pass through the other side and into the toilet.

After meeting with Professor Laurence Lovat, an enormous amount of insight into the technicalities of our project was provided. Some of the key points included factoring in both chelation contact time and the safety of handling the device (for example, whether there is a risk of contaminated urine splashing anywhere). Of immediate priority was the former point.

In theory, the chelation step can only occur once cisplatin has undergone aquation (has lost its chloride ions) [4]. After further research, it was discovered that the aquation step is quite long, in the magnitude of several hours [5]. There is not much literature on this, but what was found was initially taken as fact. It was also found that a higher pH is preferable for coordination to occur [6], so addition of a basic reagent was also highly considered.

Drawing of a funnel resting on a toilet bowl, its inside lined with the chelating ligand, with an arrow showing urine poured in at the top
Figure 2: Funnel design

A funnel coated inside with a chelating agent sits on the toilet seat. Urine runs straight through it into the toilet, and cisplatin binds.

Designs 2–4

After the first set of feedback, three separate designs were made:

  • A “teabag” containing chelating agent that is placed in the toilet bowl prior to urination and is then left before being removed and disposed of.
  • A “clip-on bag” internally coated with chelating agent that is attached to the toilet seat and collects urine that pools alongside the teabag.
  • A chelating-agent-containing “filter cup” for use in cancer wards, into which collected patient urine is emptied.
Drawing of a mesh teabag of ligand being lowered into a toilet bowl, then lifted back out and dropped into a bin
Figure 3: Toilet teabag design

A mesh bag containing the chelating agent is dropped into the toilet and later removed and disposed of.

Drawing of a bag clipped to the toilet rim and lined with the ligand, shown left to stand for a time, then emptied into the bowl and binned
Figure 4: Initial clip-on bag design

A disposable plastic bag internally coated with the ligand. It is urinated into and, after being left to enable chelation outside the toilet, is emptied back into the toilet bowl. The bag is sent for incineration.

Drawing of a jug pouring urine into a cup packed with the ligand, with treated liquid collecting in a container below
Figure 5: Filter cup design

A filter cup into which urine collected from patients on the cancer ward is emptied. It feeds a chelation tank, producing treated urine and a contaminated single-use bag for incineration.

All three designs now include sodium carbonate to increase the urine’s pH. They also all require a delay for adequate chelation to occur. These designs were presented to the Cancer Patient and Public Advisory Group (CPPAG) to get insight from the patients who would be using our hardware.

Almost immediately, the first and third designs were rejected. The first was rejected due to the inability to flush or defecate whilst aquation and chelation are occurring, as well as the need to actively take out the teabag, which can be considered unsafe and is too much of a burden for patients and carers. The third was rejected by Isla-Jayne Burzio, the chair of CPPAG, who stated that it was highly unlikely for there to be a large filter cup for constant addition of patient urine within the ward.

On the other hand, the second design was praised yet given critical feedback. The intention was for patients to easily remove the bag and store it with the urine inside whilst chelation occurs. Once the recommended time period was over, the bag could be emptied into the toilet, leaving behind most of the cisplatin inside for disposal. The only negative criticism given for this design was the fact that the bag would be stored with urine inside, which was considered disgusting. The patients’ suggestion was to have an absorbent material within the bag to soak up the liquid, removing the more unpleasant element of the setup.

Design 5

The next design was similar to the “clip-on bag”, but the chelating agent is coated on a cellulose sponge within the bag. In addition to removing the large volume of liquid urine, the sponge also provides an extremely high surface area for chelation to occur.

In more detail, this design consists of two parts:

  • A recycled polypropylene frame that attaches to the toilet seat and has a lever that can be used to squeeze the urine out of the sponge.
  • A disposable cartridge containing the sponge. There is a peelable strip at the bottom that enables pores to be opened for release of urine after the chelation period. The cartridges are then disposed of.

This was deemed the final design for a while, so the bulk of the life cycle assessment and techno-economic model outputs are actually based on this design.

Design 6

During write-up of the literature, it was decided as a group that there was insufficient evidence to support the long aquation time of cisplatin stated in one piece of literature [5]. Additionally, as the hardware serves as a device for all heavy metal pharmaceutical manufacture, the much faster chelation kinetics of other heavy metals were assumed instead [7].

This meant that several aspects of the previous design could be scaled down:

  • A smaller overall size, as only the volume from one urination needs to be held rather than multiple.
  • Removal of the strip from the cartridges, as the liquid no longer needs to sit.

The sponge has been retained so that urine doesn’t just pass straight through (it still needs a short contact time), whilst also enabling the surface area of chelating agent to remain high.

Ultimately, the design is as follows:

  1. A reusable frame containing a lever arm is attached to the toilet seat.
  2. The lever arm is pushed back to raise the press plate at the bottom.
  3. A disposable cartridge containing the chelating-agent-coated sponge is placed into the frame.
  4. The patient urinates into the device, causing their urine to pass directly through the chelating sponge.
  5. After a period of roughly 10 minutes, the lever is pushed forward, squashing the sponge and releasing the urine from the sponge into the toilet.

Using Fusion 360, the designs of these parts were visualised (Figures 6 and 7).

Engineering drawing sheet titled Reusable Frame, with a side view and a sectioned top view at 1 to 3 scale, the cartridge holder and press plate labelled, and a title block
Figure 6: Simplified mechanical drawing of the reusable frame design

Consists of the frame that attaches to the toilet. It has a lever used to squash the cartridge and the sponge within.

Open Figure 6 full size →

Engineering drawing sheet titled Disposable Cartridge, with a side view and a sectioned top view at 1 to 1 scale and a title block
Figure 7: Simplified mechanical drawing of the disposable cartridge design

Consists of the cartridge that is placed into the frame. It contains an empty space for the sponge. Note that the cartridge is compressible.

Open Figure 7 full size →

This too was considered a final design, and so was used to update the techno-economic model for greater accuracy. That said, this wasn’t the true final design, as an issue was discovered: too much force was required for a chemotherapy patient to use the lever at its current height, and making it any longer would cause its own problems.

Final Mechanical Design

The final design abandons the lever, instead adding a third part: the plunger. This is also reusable, but is separate from the frame and is stored separately, similarly to a toilet brush. Firstly, the cartridge is placed into the frame. Ten minutes after urinating, the plunger can then be used to squash the sponge by pushing against the cartridge’s press cap, releasing the treated urine into the toilet. The plunger can then be used to hook two tabs on the cartridge, removing it from the toilet easily. The cartridge should be allowed to drip and then be disposed of in an appropriate bin bag.

The measurements needed to fit the new design have been summarised in Tables 1 to 6.

Table 1: Sourced design parameters

ParameterValueSet bySource
Urine void volume245 mL mean, 425 mL maxHuman physiology[8] [9]
Toilet envelope350–380 mm bowl, 400–450 mm seat, 100–180 mm fixingsUK standard[10] [11]
Mounting precedent330 × 203 mm (0.61 mm wall); 68 g polypropylene rim lip and lowered seatClinical nun’s cap[12] [13]
Pulp wall range3–5 mm for transfer-moulded traysProcess limit[14]
Toilet seat hole213 × 285 mmUK standard[10] [11]

Table 2: Assumed design parameters

ParameterValueSet bySource
Dwell time10 minutes (drain in place)Aquation and coordination kinetics[7]
Cartridge volumeAt least one voidShort dwell time–
Cavity target600 mLAbove max void volume–

Table 3: Parameters impacting shape design

ParameterValueSet bySource
Sponge capillary limitPore < 0.23 mm at 0.050 N/m surface tension of urineJurin’s law[15] [16]
Cavity height45 mmShallow enough for a sponge to retain fluid–
Press pressure15–30 kPaAssumed–
Cavity width112 mm floor; 116.7 mm mouthA wider cavity requires more force; a shorter cavity can cause technical problems for users–
Cavity589 mL total; assumed ~10% sponge fraction, usable volume of ~530 mLCavity heights and widths–

Table 4: Disposable cartridge design

ParameterValueSet bySource
Tray wall3 mm, 3° draftPulp wall range[17]
Base / rim / flange117.7 / 122.7 / 152.2 mmDerived from cavity volume, tray wall thickness and draft angle. Also adds 8.6 mm width going up the cartridge (tapered design)–
Body at flange15 mm tall, nests in frame cone, 45°Derived from tray wall thickness, draft angle and base/rim/flange dimensions–
Cartridge funnel201 × 274 mm; 120.5 mm tallFrame height–
Press capPulp dish, 111.3 mm square base, 15 mm tall, 3 mm wall (25 g)Cartridge dimensions–
Tabs2 × (44 × 32 mm), 22 × 27 mm window, 5 mm barTypical–
Floor holes36 × (0.6 mm), 17 mm pitchTypical / assumed–
Sponge mass30 gCavity volume[18]
Tray and skirt masses147 gDerived from base/rim/flange dimensions and tray wall thickness[19]
Sodium carbonate3 gpH buffer[20] [21]
Total pulp mass171 g––

Note: masses do not go into the overall design of the hardware, but they do feed directly into the techno-economic and life cycle assessment models.

Table 5: Reusable frame design

ParameterValueSet bySource
Funnel throat155.2 mm inner width, 45° cone to 125.2 mm5 mm clearance of body at flange–
Funnel mouth199 × 269 mmSeat hole minus 5 mm per side–
Funnel depth / slope55 mm, 68° walls, 44° from horizontalSteep enough not to pool–
Funnel mass103 g––
Rim bands and ribs260 × 320 × 2.5 mm (65 g)––
Stack below toilet rim132 mmMust clear bowl water–
Sleeve and rib grid5 × 5 open rib grid, 3 × 14 mm, ~77% open (101 g)Must carry 600 N without a plate–

Note: masses do not go into the overall design of the hardware, but they do feed directly into the techno-economic and life cycle assessment models.

Table 6: Mechanism design (squeezing the sponge)

ParameterValueSet bySource
Press force250 N; limit 290 N for patientsMedical standard[22]
Press plate104.1 mm², 5 mm width, ribs and hub (89 g)Must fit within the cap, pressing down on it without going beyond its perimeter–
Shaft32 mm outer diameter, 26 mm inner diameter, 450 mm overall (75 g)Typical–
Grip and palm cap38 mm diameter, 120 mm length (68 g)Medical equipment standard[22]
Hooks2 × spring fingers and barbs (10 g)Standard–
Polypropylene mass total532 g––

Note: masses do not go into the overall design of the hardware, but they do feed directly into the techno-economic and life cycle assessment models.

The designs listed in Tables 1 to 6 have been used to create the overarching mechanical design, put together in Fusion 360.

Engineering drawing sheet titled Reusable Frame 7, with a front view and a top view carrying dimensions, and a title block
Figure 8: Mechanical drawing of the reusable frame (final)

The complete frame placed into the toilet prior to urination.

Open Figure 8 full size →

Engineering drawing sheet titled Reusable Plunger 7, with a front view and a projected view carrying dimensions, and a title block
Figure 9: Mechanical drawing of the reusable plunger (final)

The instrument used to squeeze the cartridge and lift it out of the frame without exposing the user to urine.

Open Figure 9 full size →

Engineering drawing sheet titled Disposable Cartridge 7, with a front view and a top view carrying dimensions, and a title block
Figure 10: Mechanical drawing of the disposable cartridge (final)

Functionally a disposable, smaller version of the frame. It contains a sponge (not shown) and is placed within the frame before use.

Open Figure 10 full size →

Usage

  1. The patient or carer places the reusable frame onto the toilet seat.
  2. The patient inserts a disposable cartridge into the frame.
  3. The patient sits on the toilet seat, on the rim of the frame top, and urinates. This urine soaks into the sponge within the cartridge, initiating chelation with the chitobiose and chitotriose ligands within it. No urine makes contact with the frame or toilet at this point.
  4. After a short period of time (10 minutes), a cap is dropped onto the cartridge, covering the top of the sponge to produce a urine-free roof.
  5. The reusable plunger is then used to push down onto the cartridge, squeezing the urine out of the sponge without exposing the plunger to any urine. The urine leaves the sponge without the cisplatin and passes through the bottom of the cartridge and the small grates at the base of the frame. This is the only point of contact between urine and the frame.
  6. After pushing down the sponge, the hooks on the plunger are now positioned below the tabs on the cartridge. Upon removing the plunger, the cartridge will be removed from the frame. After allowing it to drip, it should be placed into a suitable bin for disposal.
  7. The frame can now be removed from the toilet seat and placed on a stand.
Seven numbered drawings showing the device in use: place the frame, drop in a cartridge, urinate and wait, add the press cap, squeeze, lift out and bin, then store the frame
Figure 11: Usage of the device as a storyboard

Urine doesn’t make contact with the reusable parts at any point except steps 5 and 6. Here, it should only make contact with the tiny grates at the bottom.

References
  1. Namla, D., Oves, M., Alshaeri, M. A., Al-Maaqar, S. M., Issa, H. N. Y. and Mangse, G. (2025). Nanofiltration as an advanced wastewater treatment technique: A comprehensive review. Discover Applied Sciences, 7(4).
  2. European Union (2024). Directive (EU) 2024/3019 of the European Parliament and of the Council of 27 November 2024 concerning urban wastewater treatment. https://eur-lex.europa.eu/eli/dir/2024/3019/oj
  3. Food and Drug Administration (2021). Highlights of prescribing information.
  4. Corinti, D., Coletti, C., Re, N., Piccirillo, S., Giampà, M., Crestoni, M. E. and Fornarini, S. (2017). Hydrolysis of cis- and transplatin: Structure and reactivity of the aqua complexes in a solvent free environment. RSC Advances, 7(26), 15877–15884. https://doi.org/10.1039/C7RA01182B
  5. Hann, S., Koellensperger, G., Stefánka, Z., Stingeder, G., Fürhacker, M., Buchberger, W. and Mader, R. M. (2003). Application of HPLC-ICP-MS to speciation of cisplatin and its degradation products in water containing different chloride concentrations and in human urine. Journal of Analytical Atomic Spectrometry, 18(11), 1391–1395. https://doi.org/10.1039/B309028K
  6. Schaller, C. (2019). Proton as a common Lewis acid. Chemistry LibreTexts, 28 October 2019.
  7. Schaller, C. (2021). Trends in kinetic lability. Chemistry LibreTexts, 13 August 2021.
  8. Wyman, J. F., Zhou, J., LaCoursiere, D. Y., Markland, A. D., Mueller, E. R., Simon, L., Stapleton, A., Stoll, C. R. T., Chu, H. and Sutcliffe, S. (2020). Normative noninvasive bladder function measurements in healthy women: A systematic review and meta-analysis. Neurourology and Urodynamics, 39(2), 507–522.
  9. Huang Foen Chung, J. W. N. C. and van Mastrigt, R. (2009). Age and volume dependent normal frequency volume charts for healthy males. Journal of Urology, 182(1), 210–214.
  10. Bathroom Mountain (2025). Bathroom Mountain. bathroommountain.co.uk
  11. Allardyce, G. (2025). Are toilet seats a standard size? Royal Bathrooms, 28 February 2025. royalbathrooms.co.uk
  12. Bowen, C. (2024). 10.1 Urine specimen — Clinical Nursing Skills. OpenStax, 26 June 2024.
  13. Kahntact Medical (2024). Urine hats specimen collection. 10 April 2024.
  14. Grove, C., Robert, F. and Hurter, P. (2017). Are nonwood fibers right for you? Maybe, maybe not! 2017 IMFA Annual Seminar.
  15. Jurin, J. (1718). An account of some experiments shown before the Royal Society; with an enquiry into the cause of the ascent and suspension of water in capillary tubes. Philosophical Transactions of the Royal Society, 30(355), 739–747.
  16. Thomas, E. A., Poritz, D. H. and Muirhead, D. L. (2009). Urine advancing contact angle on several surfaces. Journal of Adhesion Science and Technology, 23(15), 1917–1923.
  17. MPE (2018). Molded Pulp Engineering. 6 February 2018.
  18. Spontex Industrial (n.d.). Cellulose sponge (materials). Accessed 17 October 2026.
  19. Hua, G., Yang, M., Fei, W. and Lu, F. (2020). Poisson’s ratios of molded pulp materials by digital image correlation method and uniaxial tensile test. Journal of Engineered Fibers and Fabrics, 15, 1558925020908271.
  20. Brandis, K. (2019). Renal regulation of acid-base balance. Medicine LibreTexts, 3 February 2019.
  21. Mayo Clinic Laboratories (2018). Phosphorus, 24 hour, urine.
  22. Canadian Centre for Occupational Health and Safety (2020). Pushing and pulling — general: OSH Answers. 12 May 2020. https://www.ccohs.ca/oshanswers/ergonomics/push1.html