Loading the page
Where each step is done, who may do it, and what we have deliberately not built
More than half a century ago, the geneticist Stanley Cohen and his colleagues told the world that they had built a plasmid — a ring of DNA — carrying a gene from another organism into an E. coli cell. That was the birth of genetic engineering. Since the first genetically modified organisms appeared they have drawn curiosity and inspiration, and a growing unease along with them.
We still take that work, which undoubtedly carries some degree of risk, as a vocation worth pursuing carefully. Winning broad acceptance for synthetic biology in everyday life is part of the same task, and much of that effort is still ahead of us. Biosafety has never mattered more as the science grows: without it, science stays caged in the laboratory, and any medical improvement built on biological products stays a dream that never arrives.
Our management rationale follows the Safe Laboratory Practices published by National Cheng Kung University, used here as our reference.[1]
| Work | Where | Supervision |
|---|---|---|
| Cloning, E. coli transformation, fluorescence readout, double-layer agar plates | BSL-1 area | Advisors |
| Any step involving live P. aeruginosa | BSL-2 laboratory, biological safety cabinet | PIs and advisors |
In accordance with the Taiwan Ministry of Health and Welfare’s Regulations Governing Management of Infectious Biological Materials[4] and university policy, 10 hours of training and a knowledge assessment must be completed before entering a BSL-2 laboratory:
Only members who have completed the additional BSL-2 training and been authorised by the PI carry out steps involving the pathogen; other members do not. Laboratory notebooks, the strain inventory, labelling and storage locations are managed centrally by our safety officer.
Personal protective equipment, disinfection and the accidental-exposure reporting procedure all follow the current rules of NCKU’s Environmental Protection and Safety Health Center.
We did not exchange samples with other teams this season; samples moved only between the different laboratories within our team. We followed iGEM’s policies[2] and the relevant domestic rules for biological material, and moved only plasmid DNA or laboratory E. coli strains — never the pathogen.
| Role | Name | |
|---|---|---|
| NCKU Environmental Protection and Safety Health Center — Biosafety and Radiation Protection Group, group leader | Lin, Wei-Chen, Ph.D. | wcnikelin@mail.ncku.edu.tw |
| Laboratory supervision | Masayuki Hashimoto | hashmate@mail.ncku.edu.tw |
| Laboratory supervision | I-son Ng | yswu@mail.ncku.edu.tw |
Our project runs along two routes: it listens for the quorum sensing signals (AHLs) of Pseudomonas aeruginosa, and it releases aptamers that interrupt those signals. Detection comes first and acts as navigation — it confirms that the target molecules are really there before we try to quiet the bacteria down.
The two routes carry different risks. Detection relies on an engineered E. coli reporter, so its risks are those of handling a genetically modified laboratory strain alongside the P. aeruginosa cultures it is tested against. Inhibition adds the question of what the aptamers do once released: an aptamer extracted from E. coli carries the host’s endotoxin with it, and quieting AHL signalling may affect bacteria other than the target. The organisms and chemicals behind both routes are set out below; the open questions on inhibition are listed under Unfinished Business.
Between the two sits a third piece that does not yet work, and we describe it here because it is the part of the design with the clearest safety consequences. To get the aptamer out of the cell that makes it, we built an AHL-triggered release module: the LasR-responsive promoter pLasRV driving the E7 lysis protein, so that detecting the signal triggers release rather than a constant leak (Parts, BBa_26OOQEIP). The plasmid was constructed; the module has not been validated, and no result on this wiki depends on it (Engineering). Two things follow from it even so. E7 lyses the cell that expresses it, so the only thing the circuit kills is its own host. And lysing a Gram-negative cell frees that cell’s own lipopolysaccharide along with whatever it was carrying, which is why a released preparation is not the same thing as a purified one — see Unfinished Business.
The table below is our own draft, with risk groups taken from the NIH Guidelines.[5] The risk group and containment level must follow the determination of NCKU’s Institutional Biosafety Committee, based on a local risk assessment.[3]
| Organism | Strain | Role in the project | Risk group | Containment |
|---|---|---|---|---|
| Escherichia coli | TOP10 and DH5α (K-12 derived laboratory strains); BL21(DE3) (B-strain derivative) | Host for all engineered parts: the signal-sensing reporter and aptamer production | RG1 | BSL-1 |
| Pseudomonas aeruginosa | PAO1 | Source of the signals, and the organism we assess against | RG2 | BSL-2 |
BL21(DE3) is not a K-12 derivative. We place it in RG1 because, under the NIH Guidelines, a strain of E. coli is an RG1 agent if it lacks a complete lipopolysaccharide (no O antigen) and carries no active virulence or colonization factors, nor any genes encoding them.[5]
The division of labour matters here. All genetic modification happens in E. coli, which is both our detector and our synthetic biology tool; P. aeruginosa is only an organism we test against, and is never genetically modified. No virulence factors were introduced into our chassis, and the only antibiotic-resistance genes present are the standard plasmid selection markers required for cloning — no resistance determinant from a clinical isolate was cloned or transferred. One gene in the design is lethal, and we would rather name it than leave it to be found: the E7 lysis protein in the release module above. It permeabilises the envelope of the E. coli cell that expresses it and acts on nothing else, so it is neither a toxin directed at another organism nor a virulence factor. Nothing else we added harms a cell.
The chemicals below are the hazardous ones our protocols use.
| Chemical | Main hazard | Control we apply |
|---|---|---|
| Dimethyl sulfoxide (DMSO) | Absorbed through skin quickly, and carries dissolved chemicals in with it | Nitrile gloves, changed at once if wetted; hazardous solutes dissolved in the fume hood |
| Ethyl acetate | Volatile and flammable | Fume hood, no ignition source nearby, containers kept closed |
| Ethanol | Highly flammable | Kept away from ignition sources, small working volumes, stored in the flammables cabinet |
| Hydrochloric acid (HCl) | Corrosive | Fume hood, goggles and apron, acid added to water (never the reverse), spill kit within reach |
| TRIzol (phenol and guanidine thiocyanate) | Toxic by skin contact and inhalation, causes severe burns; releases toxic gas if mixed with bleach or acids | Every TRIzol step in the fume hood; nitrile gloves changed at once if splashed, goggles and lab coat; waste collected separately and never mixed with bleach |
| Chloroform | Harmful vapour; dizziness and CNS depression at high levels, liver and kidney damage on repeated exposure | Fume hood only, smallest workable volume |
| Isopropanol | Flammable and irritant | Away from ignition sources, gloves, good ventilation |
| Crystal violet | Causes serious eye damage, harmful if swallowed, suspected carcinogen; very toxic to aquatic life | Gloves and goggles; used only as a dilute 0.1% stain; spent stain collected, never poured down the sink |
| Acetic acid (30%) | Corrosive to skin and eyes; pungent vapour | Gloves and goggles, good ventilation, small working volumes |
All of these go to the chemical waste stream described above, never down the sink.
Our approach through the experiments and the rest of our work is a conservative one, but we expect that the story could be extended, inside synthetic biology or outside it. Those extensions would bring risks of their own — during sample collection, during experiments, or on contact with highly regulated strains.
Our results are an in vitro proof of concept. This is not a diagnostic device and not a drug, and it has not been validated in real clinical specimens such as sputum, bronchoalveolar lavage fluid or wound exudate.
The following are not done, and we think it is better to say so plainly for whoever picks the work up next: