Loading the page

Engineering

Part 01

Detection

Cycle 01

01 Design

We designed a LasR–pLasRV–sfGFP biosensor to convert the quorum-sensing signal 3-oxo-C12-HSL into a fluorescent output.

Read the full Design

02 Build

We constructed the ProD–LasR / pLasRV–sfGFP circuit in E. coli TOP10 and verified that LasR was expressed at approximately its expected molecular weight.

Read the full Build

03 Test

We tested the biosensor using synthetic AHL, co-culture with PAO1, and finally an agar diffusion assay with PAO1 supernatant. Detectable fluorescence appeared only in the agar-based assay, while the liquid-based tests did not produce the expected response.

Read the full Test

04 Learn

The inconsistent response showed us that simply increasing LasR expression was not enough to guarantee better sensing. We also discovered a sequence difference in our optimized LasR, so we decided to rebuild the circuit closer to the original reference design.

Read the full Learn

Design

What we set out to make, and why

To develop a system capable of detecting Pseudomonas aeruginosa, we designed a biosensor that responds to its quorum-sensing signals. We selected the LasR regulatory system, one of the major QS systems in P. aeruginosa, as the foundation of our biosensor.

LasR protein is able to bind the AHL, 3-oxo-C12-HSL, forming a dimer. Upon binding to the AHL, this active dimer can activate the LasR-responsive promoter, pLasRV, and consequently drive the transcription of the downstream sfGFP gene.[1]

To further enhance the practical applicability of our biosensor, we designed it for integration with our hardware platform, enabling the fluorescence output to be detected and analyzed.

Build

What we made, and how

Following our design, we constructed a plasmid based on the original LasRV biosensor described by Wen et al.[1] In our initial construct, we decided to replace J23101 with ProD, a strong insulated constitutive promoter characterized by Davis et al.,[2] expecting to get better LasR expression. (Fig. D1)

pTwist-ProD-LasR; LasRV-sfGFP gene map
Fig. D1 pTwist-ProD-LasR; LasRV-sfGFP gene map

The redesigned genetic circuit retained the LasR-responsive promoter pLasRV and the downstream sfGFP reporter gene. Thus, our detection system 1.0 was born, carried on a pTwist backbone with chloramphenicol resistance and a high-copy ori gene. The new plasmid was subsequently introduced into E. coli TOP10 for further fluorescence testing. (Fig. D2)

Through this construction, we aimed to create a bacterial platform capable of converting AHL signals into detectable fluorescence, allowing us to evaluate the functionality of our biosensing system in subsequent experiments. Our goal is to combine this with the hardware designed by our dry lab team members.

Enzyme digestion
Fig. D2 Enzyme digestion

A correct plasmid does not guarantee that the protein is made, so we checked for LasR itself. Whole-cell lysates of the engineered E. coli were separated by SDS-PAGE alongside a lysate of wild-type P. aeruginosa PAO1 for comparison. The engineered strain showed a band at about 27 kDa, the predicted mass of LasR, while no comparable band was visible in the PAO1 lysate. The construct therefore does express the receptor our biosensor depends on. (Fig. D3)

SDS-PAGE gel: marker lane M, a PAO1 lysate lane with no band at 27 kDa, and an engineered E. coli lane where an arrow marks a band at 27 kDa
Fig. D3 SDS-PAGE of whole-cell lysates: P. aeruginosa PAO1 (Pa) beside the engineered E. coli (E); the arrow marks LasR at 27 kDa (M, marker)

Test

What we measured

To evaluate the performance of our biosensor, we initially ordered chemically synthesized 3-oxo-C12-HSL from Sigma. Overnight cultures of engineered E. coli were diluted to an OD600 of 0.3, followed by the addition of AHL. Fluorescence was then monitored over time. However, no detectable fluorescence was observed.

Following this unsuccessful attempt, we explored an alternative approach by co-culturing our engineered E. coli with Pseudomonas aeruginosa PAO1, a natural producer of quorum-sensing signals. Although a visible green coloration appeared in the culture (Fig. D4), no detectable fluorescence was observed, indicating that the color change could not be confidently attributed to sfGFP expression.

Three culture tubes in a rack, labelled in marker: two co-cultures of PAO1 with the engineered TOP10 are green, while PAO1 alone on the right stayed pale yellow
Fig. D4 PAO1 co-cultured with the engineered E. coli TOP10 (left, middle), beside PAO1 alone (right)

We then switched to an agar diffusion assay.[3] Engineered E. coli was mixed with soft agar and overlaid onto an LB agar plate. A well was created in the center of the plate, and PAO1 culture supernatant was introduced into it. The supernatant was filtered through a 0.22 µm membrane filter before being applied to the agar well. This method cannot use synthetic AHL, because the AHL requires DMSO to dissolve. However, excessive DMSO will lead to bacterial death. Under these conditions, observable fluorescence was successfully detected. (Fig. D5) To check that the halo came from our construct rather than from the supernatant itself, we ran the same assay with E. coli TOP10 carrying the empty vector pBBR1MCS-1; no halo appeared. (Fig. D6) However, function of fluorescence differed from our initial expectations, suggesting that the biosensor’s response was not yet fully understood.

Soft agar plate on a UV transilluminator: a green halo surrounds the central well and fades with distance from it
Fig. D5 Soft-agar overlay of the engineered E. coli, with PAO1 supernatant in the central well, under UV
Soft agar plate of TOP10 carrying the empty vector pBBR1MCS-1, with PAO1 supernatant in the central well, under UV: the plate glows blue with no green halo around the well
Fig. D6 Negative control: E. coli TOP10 carrying the empty vector pBBR1MCS-1, under the same conditions, with no halo around the well

Learn

What it told us, and what changed next

As this was our first experience in synthetic biology, we initially underestimated the complexity of engineering biological systems. We expected that constructing the plasmid and then applying AHL molecules to it would be enough to give us the result we wanted.

Although fluorescence was observed in the agar diffusion assay using PAO1 supernatant, the lack of detectable fluorescence in other experimental conditions raised concerns about the performance of our genetic circuit.

In the reference design,[1] LasR expression was regulated by the constitutive promoter BBa_J23101. However, we had replaced J23101 with ProD, an insulated promoter previously reported to exhibit higher expression activity than J23101 under the conditions examined by Davis et al.[2] This modification was intended to enhance LasR expression and potentially improve the sensitivity of our biosensor. Nevertheless, we realized that stronger promoter activity does not necessarily guarantee better biosensor performance, as excessive expression may introduce additional metabolic burdens or affect the balance of the regulatory system.

In addition, we performed codon optimization on the LasR coding sequence to improve its expression in E. coli. However, sequence blast revealed an unexpected amino acid substitution relative to the reference LasR protein. We hypothesized that this substitution might have affected its structure or regulatory activity.

These unsatisfactory results raised our concerns about the reliability and consistency of the biosensor’s response. After further discussion, we decided to construct a new plasmid, carefully reviewing the genetic circuit to identify potential design issues.

Cycle 02

01 Design

Carried over from the previous round, unchanged.

02 Build

We rebuilt the J23101–LasR / pLasRV–sfGFP plasmid and transformed it into E. coli TOP10. The new construct was then verified and compared with the original ProD-based version before further testing.

Read the full Build

03 Test

We repeated the same experimental approaches used in Cycle 1, but the redesigned construct showed almost the same pattern. We also introduced LasReader software to make fluorescence analysis more objective.

Read the full Test

04 Learn

Because rebuilding the genetic circuit did not substantially improve the response, we began to suspect that the problem was not only genetic, but also AHL stability, culture conditions, and the differences between liquid, agar and cell-free environments.

Read the full Learn

reBuild

What we made, and how

Following the redesigned genetic circuit, we constructed a new plasmid in which the original ProD promoter was replaced with J23101 and the codon-optimized LasR was replaced with the unoptimized sequence, while retaining the LasR-responsive pLasRV promoter and downstream sfGFP reporter. (Fig. D7)

Gene map of the rebuilt plasmid: J23101 driving LasR, and pLasRV driving sfGFP
Fig. D7 pTwist-J23101-LasR; LasRV-sfGFP gene map

The redesigned plasmid, pTwist-J23101-LasR; LasRV-sfGFP, was introduced into E. coli TOP10 for subsequent fluorescence testing. Transformants were screened by colony PCR with the primers CmN-out and sfGFP-R, which span the insert and give an expected product of about 611 bp. (Fig. D8)

Colony PCR gel: marker lane M beside six colonies, each with a band between the 600 and 700 bp markers
Fig. D8 Colony PCR of the rebuilt construct in TOP10 (M, marker)

Whole-cell lysates of the rebuilt J23101–LasR construct were then separated by SDS-PAGE beside the ProD–LasR construct from the first cycle, both uninduced and without AHL, three lanes each. (Fig. D9)

SDS-PAGE gel flanked by marker lanes: three ProD-LasR lanes beside three J23101-LasR lanes, with an arrow marking a band between the 25 and 35 kDa markers as LasR, expected at about 27 kDa
Fig. D9 SDS-PAGE of uninduced whole-cell lysates (no AHL): ProD–LasR (lanes 1–3) beside J23101–LasR (lanes 1–3), the arrow marking LasR, expected at about 27 kDa, between the 25 and 35 kDa markers (M, marker)

Test

What we measured

To evaluate whether the promoter modification improved biosensor performance, we repeated the experimental approaches used in the first cycle, including direct supplementation with synthetic AHL, co-culture with PAO1, and agar diffusion assays.

However, the redesigned biosensor exhibited a similar response pattern to the original construct. Detectable fluorescence was still limited to the agar-based assay using PAO1 culture supernatant, while the other experimental conditions failed to produce the expected fluorescence response.

These results suggested that the genetic modifications were insufficient to overcome the limitations observed in our initial experiments.

To further analyze the fluorescence response, we collaborated with our Dry Lab team to integrate an image-processing software tool capable of identifying fluorescent regions on agar plates: the plate-photo analysis in LasReader, which finds the plate, outlines the bright region on it and reports its size in millimetres. This approach allowed us to assess the spatial distribution of fluorescence and explore a more objective method for interpreting our biosensor’s output, providing a foundation for future integration with our hardware detection platform. (Fig. D10)

Two panels: the plate photograph under UV, and the same photograph with the plate edge, the fluorescent region and its longest span marked
Fig. D10 The same plate before and after analysis: plate edge (green), fluorescent region (yellow) and its longest span, 17.1 mm (red)

Learn

What it told us, and what changed next

Despite modifying the promoter controlling LasR expression and the LasR sequence itself, we did not observe a substantial improvement in fluorescence. Although we could not rule out problems with our genetic circuit, these results encouraged us to investigate other possible factors.

We began by reconsidering the stability of AHL molecules. Previous research has shown that AHLs can undergo pH- and temperature-dependent lactonolysis, potentially reducing their biological activity.[4] In addition, PAO1 culture supernatant contains various metabolites besides AHL, which might influence our biosensor’s response. Differences between liquid culture and agar plates, including signal diffusion and bacterial growth conditions, could also contribute to the inconsistent results.

Another possibility was the difference between cell-free and living-cell systems. Our initial design was based on previous cell-free biosensor research, but the behavior of a genetic circuit may change when introduced into living bacteria. Although Chappell et al.[5] demonstrated that many regulatory elements show comparable performance in both systems, differences in their biological environments may still influence gene expression.

Since we could not identify the exact cause of our unsuccessful experiments, we decided to revisit the literature and repeat our initial synthetic AHL assay under more carefully controlled conditions, following the experimental approach described by Chappell et al.[5]

Cycle 03

01 Design

Instead of changing the genetic circuit again, we shifted our focus to factors such as pH and light exposure that might reduce AHL activity before it reached the biosensor.

Read the full Design

02 Build

Reuse the ProD- and J23101-based constructs rather than building another genetic circuit.

03 Test

We repeated the synthetic 3-oxo-C12-HSL assay as a time-course experiment in liquid culture and measured fluorescence using a plate reader.

Read the full Test

04 Learn

Measurable fluorescence was obtained; the limitation is that the control design could not distinguish AHL induction from basal reporter expression.

Read the full Learn

reDesign

What we set out to make, and why

Based on the findings from our previous engineering cycles, we decided to revisit our initial experimental approach using synthetic 3-oxo-C12-HSL. Rather than introducing further modifications to the genetic circuit, we focused on controlling experimental conditions that might affect AHL stability and biosensor performance.

Previous research has demonstrated that AHL molecules can undergo pH-dependent lactonolysis, potentially reducing their biological activity.[4] Therefore, we paid particular attention to pH control and minimized unnecessary light exposure during AHL handling and preparation.

Test

What we measured

To evaluate the fluorescence response of our LasR-based biosensor, we performed a time-course assay using synthetic 3-oxo-C12-HSL. Both the ProD- and J23101-based constructs were tested, and fluorescence was monitored using a 96-well plate reader. (Fig. D11)

A 96-well plate seen from above in the holder of the plate reader, columns 1 to 12 running left to right, most of its wells filled with culture
Fig. D11 The 96-well plate loaded for the time-course reading

Both constructs exhibited increasing fluorescence over time, with the J23101-based construct showing higher fluorescence intensity than the ProD-based construct under the tested conditions. Statistical analysis revealed significantly higher fluorescence in both engineered strains compared with the negative control, which carried the empty vector pBBR1MCS-1 — the same resistance marker, but no sfGFP (Dunnett’s test, p < 0.001). (Fig. D12)

Line chart over five hours: the negative control runs low, from 41 to 55, while the ProD construct rises from 105 to 151 and the J23101 construct from 115 to 163, every point marked with three stars
Fig. D12 Fluorescence of the two constructs in liquid culture with 1 µM 3-oxo-C12-HSL, beside a control carrying the empty vector pBBR1MCS-1, which has the same resistance marker but no sfGFP. RFU/OD600, mean ± SD (n = 3). Stars are Dunnett’s test against that control (*** p < 0.001)

However, our experimental design has an important limitation. Our negative control carried the empty vector pBBR1MCS-1, which has the resistance marker but no sfGFP gene, rather than the corresponding biosensor strain without AHL induction. Consequently, although the observed differences confirmed higher fluorescence in the engineered strains, they could not establish whether the fluorescence was specifically induced by AHL or resulted from basal reporter expression. This is a design flaw we did not notice. Therefore, while measurable fluorescence was observed in both genetic constructs, the AHL-dependent response of our biosensor remained unverified.

Learn

What it told us, and what changed next

Throughout our engineering cycles, we realized that biosensor performance depends not only on genetic design but also on experimental conditions.

Initially, we suspected that modifications to the promoter and LasR coding sequence contributed to our unsuccessful fluorescence detection. However, reconstructing the reference design did not improve the results, leading us to investigate AHL stability, culture conditions, and experimental procedures.

In our final cycle, we repeated the liquid-culture assay under more carefully controlled conditions. Both constructs exhibited increasing fluorescence over time, with statistically significant differences compared with the negative control. However, we later recognized a critical flaw in our control design: the negative control lacked the sfGFP-containing plasmid. Consequently, we could not distinguish AHL-induced fluorescence from basal reporter expression.

This experience taught us that statistical significance does not necessarily confirm biological functionality. Appropriate controls are essential for interpreting experimental results and validating biological mechanisms.

Although we were unable to conclusively demonstrate AHL-dependent induction, each engineering cycle deepened our understanding of synthetic biology. We learned to question our assumptions, systematically investigate unexpected results, and recognize the importance of experimental design. These lessons will guide future improvements to our biosensor.


Part 02

Inhibition

01 Design

We designed an Ec67 retron system to produce Cb-2 aptamer-containing ssDNA inside E. coli, reducing the need to supply chemically synthesized aptamer from outside.

Read the full Design

02 Build

We incorporated the Cb-2 sequence into the retron msd region and constructed the system on a pTwist vector. The plasmid was first propagated in TOP10 and then transferred into BL21(DE3) for expression and further characterization.

Read the full Build

03 Test

We first attempted to detect the retron-derived product by agarose gel electrophoresis, and then evaluated the system through swarming, pyocyanin and biofilm assays. All three functional assays showed inhibitory effects, but direct molecular identification of Cb-2 remained incomplete.

Read the full Test

04 Learn

Functional activity and molecular verification provide different levels of evidence. The consistent phenotypic effects encouraged us to continue developing the system, while the limitations in our control design showed exactly what the next round of validation needs to improve.

Read the full Learn

Design

What we set out to make, and why

Aptamer is a short sequence of nucleic acid, which is able to bind with the AHL of Pseudomonas aeruginosa. We found a group of ssDNA aptamers, ALS-5, A16-2 and Cb-2, which are able to bind with the AHL molecules of Pseudomonas aeruginosa: 3-oxo-C12-HSL and C4-HSL.[6] While the AHL molecules are captured, biofilm formation and motility would be inhibited. Besides, we also found a system called retron, which is able to generate ssDNA inside E. coli. Retrons occur naturally in bacteria as anti-phage defence systems, where the reverse-transcribed DNA is part of an abortive-infection response.[9] Currently, constructing aptamer by chemical synthesis is mainstream. However, they must be produced externally and supplied to the system as a pre-synthesized reagent. For applications requiring continuous aptamer availability, repeated supplementation may therefore be necessary. We chose Cb-2 aptamer to experiment, for its ability to bind two kinds of AHL simultaneously, while the other aptamers can only bind with one. We aimed to establish a biological production system that could generate the aptamer directly inside living cells. This strategy could reduce the dependence on repeated external addition of synthetic aptamers and provide a programmable platform for intracellular ssDNA production.

Cb-2 aptamer folding structure
Fig. I1 Cb-2 aptamer folding structure

In order to synthesize the ssDNA, we utilize the system called retron. This system allows E. coli to generate the single-stranded DNA in vivo. The retron system mainly consists of three components: two non-coding RNA elements, msr and msd, and a reverse transcriptase (RT), which is able to reverse transcribe the RNA sequence of the msd to ssDNA. The msr is a conserved sequence, which forms a stem structure for the reverse transcriptase to bind to the RNA. In addition, the msd is the sequence that the RT will reverse transcribe.[7]

Cb-2 aptamer with the msd region
Fig. I2 Cb-2 aptamer with the msd region

Build

What we made, and how

We constructed the engineered retron system in a pTwist vector, in which the Cb-2 aptamer sequence was incorporated into the msd region of the retron. The Ec67 retron system is driven by T7 promoter, consisting of msr, the engineered msd region carrying the Cb-2 sequence, and the Ec67 reverse transcriptase (RT) coding sequence.

Ec67-retron gene map
Fig. I3 Ec67-retron gene map

The purpose of this build was to create a bacterial platform capable of producing Cb-2-containing ssDNA intracellularly rather than supplying synthetic aptamer externally. First, we transformed the plasmid into E. coli TOP10 strain for propagation. Subsequently, we extracted the plasmid from TOP10, and transformed it into BL21(DE3). The transformed colonies were subsequently verified by colony PCR with the primers M13M4-mul and Ap-C-Out, which give an expected product of 3123 bp, before the confirmed construct was used for further characterization.

TOP10 agarose gel electrophoresis of colony PCR product
Fig. I4 TOP10 agarose gel electrophoresis of colony PCR product
BL21(DE3) agarose gel electrophoresis of colony PCR product
Fig. I5 BL21(DE3) agarose gel electrophoresis of colony PCR product

Test

What we measured

In this round, we tested the system in two ways. We first tried to detect the retron-derived ssDNA directly, and then evaluated whether the extract could inhibit quorum-sensing-associated phenotypes of P. aeruginosa. The two tests did not give the same answer, and both are reported below in the order we performed them.

1Molecular verification

In order to put the Cb-2 aptamer into function, we used a TRIzol-based extraction method to extract the intracellular nucleic acids, and then intended to use gel electrophoresis to determine if the aptamer is indeed produced. The paper we referenced used urea-PAGE and SYBR-Gold. Nonetheless, our laboratory was not equipped to perform denaturing urea-PAGE during the project period, so we initially used 2% agarose gel to analyze.

Cb-2 agarose gel electrophoresis -1
Fig. I6 Cb-2 agarose gel electrophoresis -1

First, we cultured 2 ml of E. coli to extract, and it showed nothing on the gel after our first TRIzol extraction. We hypothesized that the production rate of the aptamer was too low to show on the gel. Consequently, we decided to culture 100 ml of the bacteria each time. After this modification, a low-molecular-weight signal became visible on the gel.

As Cb-2 is 93 nts, we initially interpreted this low-molecular-weight signal as a possible product of the Cb-2, and thus we subsequently designed the functional test. Since the Cb-2 aptamer was designed to interfere with quorum-sensing signaling, we selected three quorum-sensing-associated phenotypes for functional evaluation: swarming motility, pyocyanin production and biofilm inhibition.

Cb-2 agarose gel electrophoresis -2
Fig. I7 Cb-2 agarose gel electrophoresis -2

However, we later thought the evidence from the agarose gel was not strong enough, so we compared the result with a BL21(DE3) strain without the plasmid. That sample also showed a low-molecular-weight band, and the band disappeared after we applied RNase. This suggested that RNA contributed substantially to the signal observed in our initial gel, so the band could not be regarded as direct evidence of retron-derived Cb-2 ssDNA production.

Conventional agarose gel electrophoresis might not be suitable for detecting and identifying short ssDNA molecules under our experimental conditions, since their small size and potential secondary structures make them difficult to distinguish from other nucleic acids. A denaturing urea-PAGE system would provide better resolution and reduce the influence of secondary structures by disrupting hydrogen bonds.[6] However, since this method was not available in our laboratory during the project period, further molecular verification of the Cb-2 ssDNA remains necessary.

2Functional test

In the functional assays, we compared three aptamers reported in the reference study: ALS-5, A16-2, and Cb-2. ALS-5 and A16-2 were chemically synthesized by IDT and used as reference aptamers, while the Cb-2 group was derived from our engineered retron-Cb-2 system.

Since the Cb-2 group was a crude extract rather than a purified oligonucleotide, we also included a BL21 extract control in all three assays. This sample was prepared from E. coli BL21(DE3) without the retron plasmid and went through the same culture, harvesting, and TRIzol extraction procedures as the Cb-2 sample. By comparing this group with the untreated control, we could examine whether the extraction background itself contributed to the observed effects. It is the rightmost bar in each of the charts below.

1Swarming

Unsuccessful swarming result
Fig. I8 Unsuccessful swarming result

Initially, swarming plates were prepared according to the formulation described in the original study, while the solidification and drying intervals followed the procedure used during our laboratory training. After autoclaving, the medium was allowed to solidify for 40 min, and the poured plates were air-dried for a further 30 min before inoculation. Plates were then incubated for 24 h. Under these conditions, the bacteria failed to spread across the agar surface and instead remained confined to compact, clustered colonies at the inoculation site (Fig. I8), in contrast to the extensive dendritic spreading reported in the original study.

We hypothesized that two factors contributed to this outcome: excessive evaporation during drying, which left the surface too dry to support the hydrated interfacial film required for swarming migration, and insufficient ambient humidity during incubation, which would similarly accelerate surface desiccation over the 24 h culture period.

Swarming test
Fig. I9 Swarming test

These parameters were then adjusted iteratively. Extending the solidification time to 2 h, shortening the air-drying step to 10 min, and enclosing the plates in a sealed plastic bag to limit evaporative loss during incubation together restored the dendritic spreading pattern described in the original study (Fig. I9). Under these optimized conditions, the swarming radius was measured in ImageJ and compared between Cb-2–treated and control plates. The same plates were also measured with LasReader’s Plate Imaging · Agar Vision, built by our Dry Lab team, as a cross-check on the manual ImageJ measurement. Cb-2 treatment significantly reduced the swarming radius, while the extract control left it at the untreated level (Fig. I10). This indicates that Cb-2, rather than the extract itself, suppresses population-level surface motility. The measurements and the statistics are on the Results page.

Swarming radius for control, A16-2, ALS-5, Cb-2 and the retron-free BL21 extract control
Fig. I10 Swarming radius of PAO1 treated with A16-2, ALS-5, Cb-2 or the extract control, as a percentage of the untreated control. BL21 is the extract control: the same preparation from cells carrying no retron plasmid.

2Pyocyanin

The organic phase did not show blue
Fig. I11 The organic phase didn’t show blue.

Pyocyanin is a virulence-associated metabolite produced by Pseudomonas aeruginosa. To quantify pyocyanin production, chloroform was added to the bacterial supernatant for extraction. When pyocyanin partitions into the chloroform, the organic phase should turn blue.

Then, the chloroform extract was mixed with 0.2 M HCl, which would make the aqueous phase turn pink. We subsequently measured the absorbance at 520 nm using a 96-well plate reader. The first time we conducted the experiment, the statistics showed no evident inhibition. We then examined our procedures: the chloroform should turn blue after combining with the pyocyanin molecules, but we didn’t see this change. (Fig. I11)

We attributed this result to insufficient mixing of the chloroform and the sample. After refining our experiment method, we observed the color change of pyocyanin partitioning into the chloroform (Fig. I12) and the aqueous phase turning pink when added with HCl. (Fig. I13) Cb-2 treatment significantly lowered pyocyanin production relative to the untreated control, while the extract control did not (Fig. I14). The measurements and the statistics are on the Results page.

The organic phase turned blue
Fig. I12 The chloroform layer after the extraction was repeated with more thorough mixing
The aqueous phase turned pink after adding HCl
Fig. I13 The aqueous phase after acidification with 0.2 M HCl
Pyocyanin content for control, A16-2, ALS-5, Cb-2 and the retron-free BL21 extract control
Fig. I14 Pyocyanin content of PAO1 treated with A16-2, ALS-5, Cb-2 or the extract control, as a percentage of the untreated control. BL21 is the extract control: the same preparation from cells carrying no retron plasmid.

3Biofilm

Crystal violet retained by the adherent biofilm, solubilized in acetic acid
Fig. I15 Crystal violet retained by the biofilm in a 96-well plate: the untreated control (left) beside wells treated with ALS-5, A16-2 and Cb-2 (right)

Biofilm formation was quantified by crystal violet staining. Overnight cultures were adjusted to an OD600 of 0.1, applied with aptamers and dispensed into 96-well plates and incubated statically for 48 hours.

After incubation, the planktonic supernatant was carefully aspirated, and the wells were washed twice with Milli-Q water to remove residual non-adherent cells. Adherent biofilm was stained with crystal violet, and the retained dye was solubilized in acetic acid (Fig. I15) before absorbance was recorded at 550 nm. Absorbance values were corrected by subtracting the mean of sterile medium-only wells processed in parallel, and the corrected values were normalized to the LB-treated control, set at 100%.

Cb-2 treatment significantly reduced biofilm formation (Fig. I16), which suggests that Cb-2 suppresses biofilm development in addition to the population-level motility phenotype described above. The extract control went slightly the other way and was not significantly different from the untreated control. The measurements and the statistics are on the Results page.

Biofilm content for control, ALS-5, A16-2, Cb-2 and the retron-free BL21 extract control
Fig. I16 Biofilm content of PAO1 treated with ALS-5, A16-2, Cb-2 or the extract control, as a percentage of the untreated control. BL21 is the extract control: the same preparation from cells carrying no retron plasmid. Note that this chart lists ALS-5 before A16-2.

Learn

What it told us, and what changed next

Through these experiments, we realized that functional assays and molecular verification provide different kinds of evidence. Although our agarose gel results were insufficient to directly confirm retron-derived Cb-2 ssDNA production, the swarming, pyocyanin, and biofilm assays all showed inhibitory effects consistent with the expected function of Cb-2.

Initially, we did not include a BL21(DE3) extract control because we assumed that the TRIzol extraction procedure would remove most non-target cellular components. However, we later realized that this was a limitation in our experimental design. Therefore, we repeated the functional assays using an extract from BL21(DE3) without the retron plasmid, processed through the same extraction procedure.

In all three assays, the BL21 extract showed no statistically significant difference from the untreated control, while the retron-Cb-2 extract showed significant inhibitory effects. These results suggest that the extraction background alone was unlikely to explain the observed inhibition, providing stronger functional support for our retron-Cb-2 system.

Nevertheless, we still cannot directly confirm that Cb-2 ssDNA was responsible for the inhibitory effects, since our molecular verification remained inconclusive. In addition, the concentration of Cb-2 in our crude extract was unknown, making it difficult to determine the relationship between aptamer concentration and inhibitory activity.

In future work, we would focus on directly verifying and quantifying retron-derived ssDNA using methods such as denaturing urea-PAGE with appropriate standards and sequence-specific detection. We would also improve our control design to further distinguish the effects of Cb-2 from other components associated with the engineered plasmid.

Ultimately, we hope to develop the retron system into a more reliable biological platform for continuous production of functional DNA aptamers in vivo.

Beyond the cycle

Once we have confirmed the function of our retron system, we aim to integrate our retron-Cb-2 system with an AHL-responsive lysis module, enabling engineered E. coli to detect quorum-sensing signals from Pseudomonas aeruginosa and subsequently release the intracellularly produced aptamer. We have already attempted to construct such a system, changing the sfGFP region to E7 lysis protein (Fig. I17); however, the lysis module has not yet been successfully validated. Similar synthetic circuits have previously used lysis proteins to release intracellular products from engineered E. coli following AHL detection.[8]

Gene map of the lysis construct: pLasRV driving E7, and J23101 driving LasR
Fig. I17 pTwist-pLasRV-E7; J23101-LasR gene map

For future clinical applications, the safety of bacterial lysis would also need to be carefully considered. Lysis of Gram-negative bacteria may release cellular debris and inflammatory components such as lipopolysaccharide (LPS), which could trigger unwanted immune responses. Therefore, future development should focus not only on improving lysis efficiency, but also on safer release strategies, such as controlled secretion or alternative chassis with lower inflammatory risk.


Part 03

Reader

Cycle 01

01 Design

Read the green of a GFP culture without an emission filter: one blue LED, a sensor looking from 90°, and a light trap to swallow the beam that passes straight through.

Read the full Design

02 Build

A 3D-printed optical core on a base plate, with an ESP32 and an AS7341 spectral sensor on a breadboard beside it. Two printed parts broke as their supports came off and were taped.

Read the full Build

03 Test

Room light leaked in — 11 counts on an empty cuvette — so the reader went under a shield, and a dark read that is not zero now voids its cycle. Across three mixing sessions, all 27 readings without GFP were zero, and 35 of 38 tubes with GFP read above zero.

Read the full Test

04 Learn

The wet lab found that placing the cuvette took four steps and 30 to 40 seconds, each step a chance to seat it differently. The LED was also running under its design current.

Read the full Learn

Design

What we set out to make, and why

A fluorescence reader normally tells green light from blue with an emission filter. We set out to do without one: a single 470 nm LED lights the sample, a ten-channel spectral sensor looks at it from 90°, where the beam does not go, and a light trap behind the cuvette swallows the beam that passes straight through. What the sensor sees is then a matter of which of its channels respond, not of what a filter let past.

The reasoning behind that geometry, and the optics it depends on, are set out under how the reader works.

Build

What we made, and how

The first build put a 3D-printed optical core on a base plate, with an ESP32 and the AS7341 spectral sensor on a breadboard beside it. Two of the printed parts broke as their supports came away and were taped rather than reprinted, which is the kind of thing a first build is for finding.

The parts, the wiring and what it cost are listed under how to build it.

Test

What we measured

One of the first things the reader measured was the room it was standing in: an empty cuvette read 11 counts, which is light getting in rather than anything in the tube. The reader went under a shield, and the firmware now voids any cycle whose dark read is not zero, so a leak cannot be mistaken for a sample. It has voided cycles since; the reader does not claim never to leak, it claims to notice.

Across three mixing sessions, all 27 readings of tubes without GFP came back zero, and 35 of the 38 tubes with GFP read above zero. The cells in those tubes were a test strain — E. coli TOP10 carrying a plasmid that makes sfGFP on its own — not the biosensor, so this says the reader can see the reporter, not that it can see the signal.

The sessions are written up under the three mixing sessions, and the shielding under keeping the light out.

Learn

What it told us, and what changed next

The reader worked, and using it did not. The wet lab reported that placing a cuvette took four separate steps and 30 to 40 seconds, and every one of those steps was a chance to seat the tube a little differently from the last time — which is the one thing a reader comparing one tube with another cannot afford. The LED was also found to be running under the current it had been designed for.

Neither is a fault in the optics, and that is what made the second round about the fittings rather than the physics. The feedback is under what using it was like.

Cycle 02

01 Design

A seat that takes the cuvette in one step and sets its height and position itself, holders redrawn to print without weak layers, and one resistor to bring the LED to about 10 mA.

Read the full Design

02 Build

Five printed parts and one resistor changed on the same base plate; the base plate, detector side, light trap and firmware stayed as they were.

Read the full Build

03 Test

Loading fell to 3 to 5 seconds, and one tube put back five times varied by 0.76%. Beside a SpectraMax M3 plate reader, a GFP culture read 86 counts and one without GFP, at similar density, read 0; five dilutions ranked the same way on both.

Read the full Test

04 Learn

Suspensions scraped from AHL plates read a few counts with no GFP in them. A culture without the reporter read zero while the scatter channel stayed under about 33 counts, and no longer did from 46, so the scatter channel has to be read beside the green one.

Read the full Learn

reDesign

What we set out to make, and why

Three changes, each answering something the first round found. A seat that takes the cuvette in one step and sets its height and position by itself, so the tube is placed the same way whoever places it. Holders redrawn so that they print without weak layers, after two parts broke on the first build. And one resistor, to bring the LED up to about 10 mA.

What changed between the two builds, and why, is under the first build to the second.

reBuild

What we made, and how

Five printed parts and one resistor changed, on the same base plate. The base plate itself, the detector side, the light trap and the firmware were left exactly as they were. Only five parts and a resistor changed, so the second round tested the fittings and not a new reader.

Test

What we measured

Loading a cuvette fell from 30–40 seconds to 3 to 5, and one tube taken out and put back five times varied by 0.76%, with the tube put back by wet-lab members, not by the reader’s builder.

The reader was then run beside a SpectraMax M3 plate reader. A GFP culture read 86 counts on ours and a culture without GFP, at similar density, read 0; across five dilutions the two instruments ranked the samples the same way. Ranking the same way is what we can say: the two were not run as a calibration, and we are not claiming the readings are proportional to each other.

The session is under beside a plate reader.

Learn

What it told us, and what changed next

Then the reader met a sample that was not a clean culture. Suspensions scraped from AHL plates read a few counts with no GFP in them at all, which the green channel alone cannot explain away. Reading the scatter channel beside it showed where the line is: a culture without the reporter read zero while scatter stayed under about 33 counts, and no longer did from 46.

So the green channel is not enough on its own — the scatter channel has to be read beside it, and a sample too dense cannot be trusted. On those plates the reader could not tell a suspension apart from a culture carrying no reporter at the same scatter, which agrees with what Detection found: AHL-dependent induction is not yet shown by either of us.

The dense-suspension readings are under suspensions from the AHL plates.

Where the reader stands

After two rounds, the reader can measure the sfGFP reporter but not yet the sensor’s signal. On the bench, it tells a GFP culture from one without in a few seconds per tube, and it ranks dilutions in the same order as a plate reader. It has also shown where our sensor stands: on both builds, the sensor strain reads like cells without sfGFP, below what either build can detect. What the reader needs next is not another round of part changes.

It needs an emission filter. So far the reader keeps blue and green apart using only the 90° angle between the LED and the detector and the detector’s own colour channels, and that is enough for medium to read zero every time. With dense samples it is not: we cannot yet tell whether the green channel is picking up scattered blue light or the sample’s own green. A filter that passes green and blocks blue would settle this, and the reader already has a drawer for one. The same reader can also be run from LasReader over Wi-Fi, so readings do not have to be recorded by hand.

The Hardware page covers both: see what the reader needs next and the modules it can take.


Across all three parts

Overall Learn

Looking back on our iGEM journey, we realized how much we had grown throughout this project. At the beginning, most of us had little experience in synthetic biology. We initially believed that designing a genetic circuit and assembling the necessary components would be enough to achieve our expected results. However, as we began our experiments, we soon realized that biological systems were far more complex than we had imagined.

Throughout our engineering cycles, we gradually learned how to design genetic circuits, plan experiments, troubleshoot unexpected results, and critically analyze our data. From reconsidering our genetic designs to investigating experimental conditions and recognizing the importance of appropriate controls, each challenge encouraged us to question our assumptions and think more carefully about our next steps.

Our Detection and Inhibition systems and our Reader presented different challenges and taught us different lessons. Although our final results were not as ideal as we had hoped, all three helped us understand that engineering involves much more than simply putting parts together. Even small changes in genetic design or experimental conditions can lead to unexpected outcomes, making biological systems both challenging and fascinating to study.

More importantly, we learned to appreciate the beauty and complexity of synthetic biology. What initially seemed like a straightforward engineering process gradually became an exploration of how biological components interact and how unexpected results can lead to new questions and discoveries.

From knowing almost nothing about synthetic biology to developing our own designs and learning from our experiments, this journey has changed the way we approach scientific problems. Ultimately, we learned that the value of engineering lies not only in achieving the desired outcome, but also in the knowledge, experience, and curiosity we gain along the way.

References

  1. Wen, K. Y., Cameron, L., Chappell, J., Jensen, K., Bell, D. J., Kelwick, R., Kopniczky, M., Davies, J. C., Filloux, A., & Freemont, P. S. (2017). A cell-free biosensor for detecting quorum sensing molecules in P. aeruginosa-infected respiratory samples. ACS Synthetic Biology, 6(12), 2293–2301. https://doi.org/10.1021/acssynbio.7b00219
  2. Davis, J. H., Rubin, A. J., & Sauer, R. T. (2011). Design, construction and characterization of a set of insulated bacterial promoters. Nucleic Acids Research, 39(3), 1131–1141. https://doi.org/10.1093/nar/gkq810
  3. Ravn, L., Christensen, A. B., Molin, S., Givskov, M., & Gram, L. (2001). Methods for detecting acylated homoserine lactones produced by Gram-negative bacteria and their application in studies of AHL-production kinetics. Journal of Microbiological Methods, 44(3), 239–251. https://doi.org/10.1016/S0167-7012(01)00217-2
  4. Yates, E. A., Philipp, B., Buckley, C., Atkinson, S., Chhabra, S. R., Sockett, R. E., Goldner, M., Dessaux, Y., Cámara, M., Smith, H., & Williams, P. (2002). N-Acylhomoserine lactones undergo lactonolysis in a pH-, temperature-, and acyl chain length-dependent manner during growth of Yersinia pseudotuberculosis and Pseudomonas aeruginosa. Infection and Immunity, 70(10), 5635–5646. https://doi.org/10.1128/IAI.70.10.5635-5646.2002
  5. Chappell, J., Jensen, K., & Freemont, P. S. (2013). Validation of an entirely in vitro approach for rapid prototyping of DNA regulatory elements for synthetic biology. Nucleic Acids Research, 41(5), 3471–3481. https://doi.org/10.1093/nar/gkt052
  6. Wu, K., Mo, Y., Duan, M., Zheng, Y., Chang, Y., Ding, M., Wang, Z., Wu, S., & Duan, N. (2025). A structure-guided bifunctional aptamer mitigates Pseudomonas aeruginosa virulence and biofilms by disrupting las and rhl quorum sensing systems. Analytical Chemistry, 97(37), 20291–20302. https://doi.org/10.1021/acs.analchem.5c03245
  7. Vibhute, M. A., Machatzke, C., Krümpel, S., Dirks, M., Bigler, K., Summerer, D., & Mutschler, H. (2026). Intracellular expression of a fluorogenic DNA aptamer using retron Eco2. eLife, 13, RP99554. https://doi.org/10.7554/eLife.99554
  8. Saeidi, N., Wong, C. K., Lo, T.-M., Nguyen, H. X., Ling, H., Leong, S. S. J., Poh, C. L., & Chang, M. W. (2011). Engineering microbes to sense and eradicate Pseudomonas aeruginosa, a human pathogen. Molecular Systems Biology, 7, 521. https://doi.org/10.1038/msb.2011.55
  9. Millman, A., Bernheim, A., Stokar-Avihail, A., Fedorenko, T., Voichek, M., Leavitt, A., Oppenheimer-Shaanan, Y., & Sorek, R. (2020). Bacterial retrons function in anti-phage defense. Cell, 183(6), 1551–1561.e12. https://doi.org/10.1016/j.cell.2020.09.065