Introduction

How is TFA sensed right now?

Currently, TFA is mostly sensed via LC-MS, liquid chromatography - mass spectronomy. This technique consists of two parts, an LC often an HPLC, high-performance liquid chromatography and mass spectrometry[1]. This technique works the following way. First the eluent, the mobile phase, is pumped through the system in the machine at a specific flow rate. In the second step, the sample is injected and moves with the mobile phase from the injection point to the head of the column. Next, the physical separation of the different compounds occurs in the stationary phase. After the elution of the different compounds from the column, the molecules are ready fro detection [2]. After HPLC separated the analytes, they enter the mass spectrometer. First they encounter the ion source that ionizes the analytes. Afterwards the analytes pass through the quadrupel mass analyzer. this quadrupel consists of four rods which ensure only atoms of a specific mass to charge or m/z ratio will travel to a detector at any given time. To generate a signal the detector records the signal intensity of ions arriving at a given time [1]. By measuring the area under the peak of the analyte of interest quantification of the analyte can be done [3].

Despite its popularity, LC-MS has some major drawbacks. The method is laborious and time consuming, making quick continuous sensing, as needed for our filter, difficult [4][5]. TFA’s small size, extreme polarity and structural simplicity also make it particularly difficult to sense [6].

Other TFA sensing mechanisms utilise complex chemical structures, such as chemosensors employing fluoroscence or chiral tetraethylene [6] [7]. These methods come with their own drawbacks [6], chiral tetraethylene, for instance, is toxic to aquatic life [8].

[...] from a technology development perspective, what we miss most often is on-site and online monitoring of PFAS.

For the application in our biodegradation reactor, real time monitoring is important. This way the state of the degradation tank can continuously be evaluated, and once most of the TFA is degraded, or problems arise in the tank, it can be noticed in time and the proper course of action can be taken. To, one of the oldest molecular mechanisms of bacteria is engineered in our advantage.

What are riboswitches? An alternative solution.

A riboswitch can also be used as a biosensor. A riboswitch is a genetic regulatory element that controls transcription or translation based on ligand binding, which is why it can be used as a biosensor. It consists of 2 parts on the same RNA molecule: an aptamer, which forms a binding pocket and interacts with the target, and an expression platform that switches between an ON and OFF state, based on the aptamer interaction. Immediately downstream of the riboswitch, a gene can be placed, allowing for great flexibility in the transduction pathway [9].

Schematic overview two types of riboswitches. This Figure shows the 2 types of riboswitches used during our research. Figure 1A shows the transcriptional off switch. Without a ligand an antiterminator binds to the terminator, sequestering the poly-U sequence, allowing for transcription to continue. Once a ligand binds to the aptamer domain, the antiterminator no longer sequesters the terminator. The RNA transcriptase will then bind to the poly-U tail and transcription will be terminated. Figure 1B shows a transcriptional on switch. Without ligand binding the anti-RBS, ribosome binding site, sequence binds to the RBS preventing translation. Once a ligand binds to the aptamer domain the anti-RBS no longer binds to the RBS and translation can occur. Figure made with the help of claude opus 5,5.
Figure 1. Schematic overview two types of riboswitches. This Figure shows the 2 types of riboswitches used during our research. Figure 1A shows the transcriptional off switch. Without a ligand an antiterminator binds to the terminator, sequestering the poly-U sequence, allowing for transcription to continue. Once a ligand binds to the aptamer domain, the antiterminator no longer sequesters the terminator. The RNA transcriptase will then bind to the poly-U tail and transcription will be terminated. Figure 1B shows a transcriptional on switch. Without ligand binding the anti-RBS, ribosome binding site, sequence binds to the RBS preventing translation. Once a ligand binds to the aptamer domain the anti-RBS no longer binds to the RBS and translation can occur. Figure made with the help of claude opus 5,5.
Translational on-riboswitches

The most common form of riboswitch is a translational on-riboswitch (Figure 1B), in which the mRNA is normally folded in a way that sequesters the Ribosome Binding Site (RBS) into a hairpin structure. Because of this, the ribosome cannot bind, blocking translation. When the target is present, it binds/interacts with the aptamer domain of the riboswitch, which allows a different hairpin to form, so the RBS becomes exposed and translation can take place.

Transcriptional off-riboswitches

Alternatively, transcriptional off-riboswitches can be used (Figure 1A). Transcriptional riboswitches employ terminators, consisting of a hairpin structure and poly-U sequence. The U-A interaction is the weakest nucleotide interaction, leading to the RNA polymerase detaching from the DNA and in turn the termination of transcription. These riboswitches work because normally, an anti-terminator sequesters the terminator inside a hairpin. This means that the terminator cannot be formed. When the ligand is present, it stabilises the aptamer part, so the anti-terminator is now in the aptamer. Because the anti-terminator can now no longer bind to part of the terminator, the terminator forms, and transcription of the gene after the terminator can no longer take place.

Other aptamer uses

Aptamers can also be used as biosensors in other ways. They are then called "aptasensors". "Fluoroaptasensors" work with the help of a fluorescence quencher system called optical aptasensors or by securing an aptamer to an electrode to get electrochemical aptasensors. The downside of aptasensors is that signal amplification is difficult, which is crucial for measuring low TFA concentrations. Chemical aptasensors can omit this problem by employing certain nanomaterials. These nanomaterials are however sensitive to changing conditions and fouling [10]. Another issue with aptasensors is their lack of signal reversibility [11], with riboswitches this problem can be ommited by adding degrons tags to the reporter proteins [12]. For these reasons aptasensors are not suitable for our bioreactor this system of measuring was not further pursued.

Experiments & results

Measuring strategy

The experimental procedure for the riboswitches initially went two fold. A backbone plasmid with a fluoride riboswitch, an mRFP1 reporter, origin of replication and chloramphenicol resistance gene was ordered. The first thing that was done with this plasmid was establishing an experimental procedure to test the fluoride riboswitch. In the paper that published the original fluoride riboswitch, AEB-F12 as it was called, it was tested with a concentration of 150 mM of sodiumfluoride in E. coli [13]. Our experiment was emulated as much as possible from the paper. The fluorescence was measured in plate readers with excitation of 578 nm and emission of 620 nm. Cells were first grown in an overnight culture. From this overnight culture they were washed and the OD600 was measured. The different wells were inoculated with a starting OD of 0,01 in LB medium. A triplet with the fluoride riboswitch containing cells without additional sodiumfluoride, a triplet of the same cells in 75 mM sodiumfluoride concentration, a triplet of the same cells in 150 mM sodiumfluoride concentration and a triplet of those same cells in 300 mM were tested.

The initial experiment did not yield the expected results; cell growth in the wells with high sodium fluoride was inhibited, which affected the fluorescence measurement. There were also no "negative control cells", cells with no fluorescence expression to correct for autofluorescence. These were constructed by cutting out the mRFP1 gene and riboswitch resulting in an empty backbone containing only the ORI and chloramphenicol resistance gene. After contacting the author of the paper that inspired our experimental design, we received insights that helped us refine our protocol. First, overnight cell cultures were made and then washed and measured. The washed cells were then added to 25 ml of media in a 250 ml shake flask and again grown overnight. The "negative control" cells with no sodium fluoride added, and cells containing the riboswitches in a 0, 75, 150 and 300 mM of sodium fluoride solution. After the overnight growth in the shake flasks, 1 ml of the culture was taken and washed to prepare it for the flowc ytometer. The flow cytometer either ran for 2 minutes or until 100.000 events were recorded. Within the time frame of 2 minutes at least 50.000 events were often achieved.

Fluorescence plot of fluoride riboswitch. This Figure shows the fluorescence of the AEB-F12 riboswitches compared under different fluoride concentrations. The X axis shows the mRFP1 fluorescence strength in RFU. The y-axis shows the amount of events. Sample stands for bacteria grown with the different concentrations of analyte. The amount of event per sample correlates with the area under the plot of the sample.
Figure 2. Fluorescence plot of fluoride riboswitch. This Figure shows the fluorescence of the AEB-F12 riboswitches compared under different fluoride concentrations. The X axis shows the mRFP1 fluorescence strength in RFU. The y-axis shows the amount of events. Sample stands for bacteria grown with the different concentrations of analyte. The amount of event per sample correlates with the area under the plot of the sample.

In Figure 2 we can observe that the results that came back from this experimental design yielded the expected results. A stronger shift to the right indicates higher fluorescence. Cells grown in 150 mM showed this shift to the right, and cells in a culture with 300 mM showed an even greater shift to the right. The de novo riboswitches will also be tested this way.

Cloning

The sequences from the de novo riboswitches were obtained from the dry lab. For the design of the de novo riboswitches first a sfGFP was cloned into the backbone plasmid in place of the AEB-F12 fluoride riboswitch as a drop-out cassette. This was done by restriction ligation cloning using the restriction sites XbaI and SacI. Heat shock was performed to transform the bacteria and green fluorescent colonies from plates were picked. From these green colonies a miniprep was performed. In the new plasmid containing the drop-out cassette, the de novo riboswitches were cloned using the same strategy; by using the plasmid with the drop-out cassette and the same restriction sites that were used to clone in the drop-out cassette. Although in theory this strategy should work in reality this wasn’t always as successfull, due to the randomness involved and the large ammounts of laborious steps undertaken.

For this reason, a golden gate strategy was then designed with the help of snapgene to clone the riboswitches more succesfully. This strategy resulted in the assembly of the desired constructs.

The de novo riboswitches arrived in 2 batches. The first batch consisted of only PFOA, a longer, more well known and easier to sense PFAS molecule [14], riboswitches. The second batch consists of PFOA, TFA and scrambled (non-functioning) riboswitches. The first batch were translational on switches and the second batch were transcriptional off switches (Figure 1).

The results of the riboswitch measurements were used for the riboswitch retargeting DBTL cylce.

Toxicity assay

A toxicity assay was performed to access if PFOA had a toxic affect on the cell growth that could otherwise interfere with our measurements. Bacterial cultures were exposed to PFOA concentrations of 5, 50 and 250 500 uM and tested. Because PFOA behaves like a strong acid [15], additional controls were added to assess whether the toxic effect was due to PFOA itself or due to the acidity. These controls consisted of bacterial cultures exposed to the before-mentioned PFOA concentrations and the same concentration of NaOH to neutralise the acid and cultures exposed to the same concentrations of HCl to assess the effect of acid alone. The PFOA stock solution was dissolved in methanol. The effect of PFOA on cell growth was found to be minimal. Since longer chain PFAS molecules are more cytotoxic than shorter chain ones [16], a toxicity assay for TFA was not performed as it would have been redundant.

Successful riboswitch

The tests for the de novo riboswitches were first done with extremes, meaning in a shake flask with either no analyte added or 500 uM. Here, the aim was to see if the riboswitch showed any dose response. Only one riboswitch from the second batch showed promising results (Figure 3). This was a PFOA riboswitch, which demonstrated that the pipeline created in the dry lab has potential to create an in situ continuous biosensor.

Fluorescence plot working riboswitch. This Figure shows the response of the working riboswitch. The X axis shows the mRFP1 fluorescence strength in RFU. The y-axis shows the amount of events. Sample stands for bacteria grown with the different concentrations of analyte. The amount of event per sample correlates with the area under the plot of the sample.
Figure 3. Fluorescence plot working riboswitch. This Figure shows the response of the working riboswitch. The X axis shows the mRFP1 fluorescence strength in RFU. The y-axis shows the amount of events. Sample stands for bacteria grown with the different concentrations of analyte. The amount of event per sample correlates with the area under the plot of the sample.
Table 1. Table with overview of the raw data. The Table shows the raw data per culture grown with a certain amount of analyte. Per culture, the events measured, the number of intact cells, the cells outside the autofluorescence cut-off and the intact cells as a percentage of the total events are shown. NC stands for negative control.
culture Events measured Intact cells measured cells after auto-fluorescence correction intact cells % of total events
0 mM fluoride 64136 46731 45044 72.9%
75 mM fluoride 45907 28826 28120 62.8%
150 mM fluoride 43914 9799 6476 22.3%
300 mM fluoride 63594 19970 17193 31.4%
NC MeOH 53484 37074 43 69.3%
NC water 46824 13633 25 29.1%
0 µM PFOA 96907 33253 15192 34.3%
500 µM PFOA 100000 38504 16922 38.5

(Table 1) shows the overview of the different samples. In the different scatter plots there were 2 clusters of events. The events with a higher SSC values are the cells since the cells are generally bigger than contamination and other fragments. A cut of was established at the lower end of this cluster, events below were discarded for making the fluorescence graphs. The negative controls were added to control for autofluorescence, one time with water added and one time with methanol added, because the sodiumfluoride was dissolved in water and the PFOA was dissolved in methanol. The autofluorescence had a mRFP1 fluorescence value below a 1000, so all the fluorescence bellow that, of the cultures with riboswitches, was discarded.

Conclusion & Outlook

A de novo PFOA riboswitch, generated by DISARM, has shown to respond to the ligand in our wet lab setting. This is an indication that our wet lab and dry lab combined approach is capable of generating de novo riboswitches. In order to create a working TFA riboswitch, more experiments and tests are needed. Once a proper riboswitch has been found, a degron must be engineered on the reporter protein to ensure that the signal does not stay "on", and the biosensor can be used to measure continuously.

Photo of Nijhuis Saur

Nijhuis Saur

International water treatment company

[...] from a technology development perspective, what we miss most often is on-site and online monitoring of PFAS.

Why we reached out

Nijhuis Saur implement water treatment solutions for different purposes, from municipalities to industries and even mobile solutions. They could help us draft a plan to implement Triton. We inquired about the desirability of real-time TFA-sensing.

Main takeaways

  • On-site monitoring of PFAS concentrations is important. Do not make it just a side project.

Reflection & integration

Nijhuis Saur confirmed that a continuous technique to monitor TFA concentrations would be sought after. We realised that our degradation module relies on a sensing module, so we made sensing an essential part of Triton.

References

Show all references
[1] Basics of LC/MS - a primer Agilent. (n.d.). Retrieved October 21, 2026, from https://www.agilent.com/en/product/liquid-chromatography-mass-spectrometry-lc-ms/lcms-fundamentals
[2] Tuczemskyi, C. (2023). HPLC Basics: What You Should Know. In AnalyteGuru. https://www.thermofisher.com/blog/analyteguru/hplc-basics-what-you-should-know/
[3] Tamang, S. (2026). HPLC: Principle, Instrumentation, Steps, Types, Uses, Diagram. https://microbenotes.com/high-performance-liquid-chromatography-hplc/
[4] Alves, E., Gurupadayya, B. M., & Prabhakaran, P. (2025). Artificial Intelligence in HPLC Method Development: A Critical Review of Technological Integration, Limitations, and Future Directions. Critical Reviews in Analytical Chemistry, 1–43. https://doi.org/10.1080/10408347.2025.2575352
[5] Berg, M., Parbel, A., Pettersen, H., Fenyö, D., & Björkesten, L. (2006). Reproducibility of LC-MS-based protein identification. Journal of Experimental Botany, 57(7), 1509–1514. https://doi.org/10.1093/jxb/erj139
[6] Li, Y., Li, Q., Wu, X., Shen, X., & Mao, S. (2026). Amphiphilic Fluorescent Aggregate for Highly Selective Detection of Trifluoroacetic Acid in Water. Advanced Functional Materials, 36(25), e20986. https://doi.org/10.1002/adfm.202520986
[7] Niu, X., Zhang, H., Wu, X., Zhu, S., Feng, H., & Liu, W. (2022). A novel “turn-on” fluorescent sensor based on Tetraphenylethylene-planarized bis-Schiff base for dual-state TFA detection. Journal of Molecular Structure, 1259, 132754. https://doi.org/10.1016/j.molstruc.2022.132754
[8] Road, W., & Sk, B. (2023). Details of the manufacturer or supplier of the safety data sheet. (2).
[9] Weigand, J. E., & Suess, B. (2009). Aptamers and riboswitches: Perspectives in biotechnology. Applied Microbiology and Biotechnology, 85(2), 229–236. https://doi.org/10.1007/s00253-009-2194-2
[10] Lei, Z., & Ismail, N. I. (2026). Nanomaterials-Based Electrochemical Aptasensors for Rapid Detection of Pathogens and By-Products. Molecules, 31(4), 664. https://doi.org/10.3390/molecules31040664
[11] Li, X., Liu, S., Huang, X., Yao, C., Chen, J., Gao, L., Zhou, C., Wu, Y., Liu, J., Li, M., Zhao, N., Chen, H., Huang, S., & Xie, X. (2025). Aptamers-based wearable electrochemical sensors for continuous monitoring of biomarkers in vivo. Microsystems & Nanoengineering, 11(1), 241. https://doi.org/10.1038/s41378-025-00993-5
[12] Izert, M. A., Klimecka, M. M., & Górna, M. W. (2021). Applications of Bacterial Degrons and Degraders — Toward Targeted Protein Degradation in Bacteria. Frontiers in Molecular Biosciences, 8. https://doi.org/10.3389/fmolb.2021.669762
[13] Espah Borujeni, A., Mishler, D. M., Wang, J., Huso, W., & Salis, H. M. (2016). Automated physics-based design of synthetic riboswitches from diverse RNA aptamers. Nucleic Acids Research, 44(1), 1–13. https://doi.org/10.1093/nar/gkv1289
[14] Björnsdotter, M. K., Yeung, L. W. Y., Kärrman, A., & Ericson Jogsten, I. (2020). Challenges in the analytical determination of ultra-short-chain perfluoroalkyl acids and implications for environmental and human health. Analytical and Bioanalytical Chemistry, 412(20), 4785–4796. https://doi.org/10.1007/s00216-020-02692-8
[15] Balasuryia, D., Queral-Beltran, A., Vick, T., Simpson, S., Lacorte, S., Aga, D. S., & Hoepker, A. C. (2025). Experimental Determination of p ka_{\textrm{a}} for 10 PFAS, Mono-, Di-, and Trifluoroacetic Acid by19^{\textrm{19}} F-NMR. Environmental Science & Technology Letters, 12(9), 1238–1246. https://doi.org/10.1021/acs.estlett.5c00688
[16] Sodani, K., Ter Braak, B., Hartvelt, S., Boelens, M., Jamalpoor, A., & Mukhi, S. (2025). Toxicological mode-of-action and developmental toxicity of different carbon chain length PFAS. Toxicology Letters, 405, 59–66. https://doi.org/10.1016/j.toxlet.2025.02.003
[17] Newsweek (International, Atlantic Edition) 1991-05-20: Vol 117 Iss 20. (1991). Newsweek Media Group Inc. http://archive.org/details/sim_newsweek_1991-05-20_117_20
[18] Directive 2001/18/EC of the European Parliament and of the Council of 12 March 2001 on the deliberate release into the environment of genetically modified organisms and repealing Council Directive 90/220/EEC - Commission Declaration (Vol. 106). (2001). http://data.europa.eu/eli/dir/2001/18/oj
[19] Espah Borujeni, A., Mishler, D. M., Wang, J., Huso, W., & Salis, H. M. (2016). Automated physics-based design of synthetic riboswitches from diverse RNA aptamers. Nucleic Acids Research, 44(1), 1–13. https://doi.org/10.1093/nar/gkv1289