Wet Lab

Creating high-throughput, scalable assays to test candidate enzymes retrieved by Dry Lab.

Results

Protocol Summary

The following protocol summary describes the workflow for both the Biosensor and Selection assays:

  1. Prepare plates
  2. Integrate copper sulphate into PET mesh
  3. Transform E. coli (BL21(DE3)) with PD-V2 plasmid (Empty or containing LCC, Fast-PETase, IsPETase, M4-Q IsPETase, Dead-IsPETase, or Dry Lab PETase sequence) and AS plasmid (containing either msGFP2 or sul1)
  4. Plate transformed E. coli onto control (no mesh/no mesh or sulfadiazine) and test (with mesh) plates
  5. Identify colony fluorescence using transilluminator (Biosensor assay)/look for colonies (Selection assay)
  6. Pick colonies selected for by the assay and perform colony PCR
  7. Send the resulting amplicons for sequencing to identify successful PETase variants and their corresponding colonies for downstream testing

Copper Toxicity

E. coli cells can have their growth impaired by sufficiently high copper concentrations. To test the lethal copper dose, we ran a series of experiments testing E. coli dilutions (10¹⁰, 10⁸, 10⁷, 10⁶ 10⁵,10⁴, 10³, 10²) on a range of copper concentrations (0mM, 0.25mM, 0.5mM, 1mM, 2mM, 4mM, and 8mM) mixed onto agar plates. For details, see the Copper Plate Testing document below. It was determined that the range of all plates up to 4mM (10⁸ to 10²) did not alter bacterial growth detrimentally. Finding the highest copper concentration that does not inhibit bacterial growth informs how much copper can be integrated into PET for the assay.

Copper Plate TestingOpen PDF ↗
copper tox
Figure 1. Copper toxicity and pCusC dynamic range testing with selected plates. msGFP2 fluorescence is expected to increase with increasing copper concentrations in plates, while growth is expected to decrease.

Copper leakage and background fluorescence

We conducted a leakage test to ensure that the PET mesh won’t leach out copper. If the mesh released copper without requiring any PETase activity, this would result in false positives. Thus, we transformed our E. Coli cells with only the biosensor AS plasmid and placed the PET mesh on top of the agar to see if any cells would fluoresce without PETase activity. As seen below, copper was not detected in the cells, indicating that copper leakage from the PET mesh did not occur. Additionally, background fluorescence was insignificant.

result1
Figure 2. AS-msGFP2 test plates incubated with copper infused mesh to test for copper leakage under no PETase activity.

Copper-Induced GFP Expression

To ensure that our AS plasmid expresses msGFP2 in the presence of copper, we conducted a serial dilution experiment to determine which concentrations of copper colonies would fluoresce. To observe the fluorescence, a UV light was shone onto the colonies. In the images below, it can be seen that the reporting plasmid functions within a certain range. Plates were made using 38g/L MHA in MilliQ water. After microwaving, sterile CuSO₄ was added to make 0mM, 0.25mM, 0.5mM, 1mM, 2mM, 4mM, and 8mM plates. Kanamycin was kept at 50ug/mL. BL21(DE3) transformed with AS-msGFP2 was liquid cultured overnight. The cells were washed with saline and spotted onto the plate at different dilutions (dilutions deviate from protocol, see Figure 3).

result2
Figure 3. The growth of BL21(DE3) transformed with AS-msGFP2 on MHA plates with kanamycin and different copper concentrations.
result3
Figure 4. Select spots of growth were placed under blue light to check for fluorescence.

One negative control is growing BL21(DE3) transformed with AS-msGFP2 on a plate with 0mM CuSO₄ to check if fluorescence is due to other factors than the copper-induced expression of msGFP2. Figure 4a shows the negative control under blue light, verifying that fluorescence is dependent on copper.

Another negative control is growing BL21(DE3) that is transformed with the empty AS plasmid with no msGFP2 on a plate with CuSO₄ to check if fluorescence can be induced by copper or other factors without the expression of a fluorescent gene. Figure 4b shows the negative control under blue light, verifying that fluorescence is due to expression of msGFP2.

Figure 4c (4mM of CuSO₄) shows that when copper is present to induce expression msGFP2, the cells fluoresce under blue light. This verifies for the biosensor assay that copper can induce msGFP2 expression. The next steps are to test whether msGFP2 can be sufficiently expressed with the copper amounts that can be realistically released from the mesh

result4a
Figure 5. The growth of BL21(DE3) transformed with sul1 on MHA plates with kanamycin and varying copper concentrations.

Copper toxicity testing was done with 36ug/mL kan and dilutions of (10¹², 10⁶, 10⁴, 10²) with sul1 showing growth on all plates except on the 8mM copper concentration plate (Figure 5).

Testing Assays with Characterized PETases

Lastly, we wanted to conduct a positive control to see if the biosensor would perform as expected with a working PETase. Thus, we transformed our cells with a PD-V2 plasmid containing a known PETase (LCC, Fast-PETase, IsPETase, M4-Q IsPETase, Dead-IsPETase) and the reporting plasmid. Empty PD-V2 was also transformed and tested as a control. We then placed the copper mesh onto our agar and let it grow overnight to see if the colonies would fluoresce. For the Biosensor assay, only the plate containing M4-Q IsPETase grew in our initial test. However, these colonies exhibited fluorescence, providing evidence that the Biosensor assay is functional (Figure 6).

result4
Figure 6. Transformed BL21(DE3) with AS-msGFP2 and PD-V2 plasmid incubated with copper mesh for 84 hours. The bottom right plate being a M4-Q IsPETase control plated without mesh. The plate to the left of this control is M4-Q IsPETase. Mesh was partially or fully removed from all test plates before this image was taken.

For the Selection assay, all test plates except for Dead-IsPETase showed growth with colonies morphologically similar to those observed on sul1 copper toxicity test plates in (Figure 7).

result5
Figure 7. Transformed BL21(DE3) with AS-sul1 and PD-V2 plasmid incubated with copper mesh for 84 hours. The top left plate is Dead-IsPETase, and mesh is still present in all six plate images.

Continuing Work

In the coming weeks, PETase display will be verified using fluorescent FLAG antibodies, control tests for both assays will continue to be run to confirm functionality, and Dry Lab PETase sequences will be tested with both the Biosensor and Selection assay.