Hardware

Engineering parallel bioreactor systems that can quantify enzymatic degradation in various conditions.

Past Iterations

Explore two hardware iterations and the evolution of each subsystem.

Version
Hover over (or tap) a part to see what it does, and click it to open that subsystem.

DBTL

01Design02Build03Test04Learn

Choose a stage, or scroll through the notes.

01 Design

We assembled a reference design, the Pioreactor, identifying strengths and areas for improvement. We also discussed the importance of key features, most notably, user friendly controls, with key stakeholders: the CEO of Pioractor and Patricia, one of our wetlab members. We compiled these notes together onto a shared white-board, and used them to inform and justify our first set of requirements (link to requirements V1) and subsystems diagram. This phase also required choosing our initial components from the microcontroller to OD sensor.

overview1
Figure 1: Sticky notes contain team thoughts on Pioreactor design and stakeholder input [Left] and fully assembled Pioreactor [Right]
overview2
Figure 2: First subsystem diagram Arrows show control signal connections between electronic components.

02 Build

In V1, we built subsystems separately to enable independent testing of temperature control, power distribution, peristaltic pumps, optical density (OD) and more. This meant wiring circuits on breadboards for quick prototyping, making separate CAD designs for different subsystem tests (i.e, a separate CAD model for OD vs temperature testing), and using substitutes for plastic where possible (i.e. cardboard to surround the heating plate or a falcon tube for mixing tests). The overall design had two power lines: external power for the power-intensive heater and pumps, and 5V power from the breadboard for sensors, smaller components, and control of pumps and heaters.

overview3
Figure 3: Securing heating plate with temporary cardboard holder during prototyping phase.
overview4
Figure 4: Magnetic stir bar rotates through heating plate using PC fan

03 Test

We tested the temperature control, optical density (OD), peristaltic pump, and stirring systems independently. The temperature control tests showed that the heater can raise the internal temperature to approximately 56.56 °C without insulation and sense temperature within +/- 0.5 °C. The OD sensors were shown to detect both transparent and opaque materials as changes in optical density. The peristaltic pump fluid output (oz) was measured at varying power inputs. The range of possible RPMs for the stir bar was also measured.

overview5

04 Learn

From testing, we learned that the PC fan’s lowest RPM was too high to support bacterial growth, requiring a replacement part, the OD sensor location needed to be raised to a specific height to avoid stir bar interference, and that the peristaltic pump needed a power input of at least 60%. Several circuitry bugs also surfaced, including the need for a transistor for the peristaltic pump circuit. Performing a “post mortem” on our design, we identified designing the user interface as a major next step.

overview6

Stakeholder Information/Interviews

To inform the design of our bioreactor, we decided to consult a few key expert opinions in order to truly understand the design space and audience we are building the bioreactor for. Here is a summary of the V1 stakeholders and how their input impacted V1 of our bioreactors. For more details, please consult the stakeholder section on our Motivation page.


Dr. Artem Babaian, iGEM Toronto PI and Director of RNALab: As the primary stakeholder for the bioreactor project, Dr. Babaian’s input guided many of the bioreactor’s constraints. These included the wattage constraints, concerns from heating and safety, restriction on Wifi as a means of communication between bioreactors. He also defined the key use case of the bioreactors: growing genetically-modified E. coli expressing PETases. He suggested that, when lysed, the PETase activity will correspond to plastic degradation of PET filament or an associated marker.


Dr. Matthew Mackay, Mechanical and Mechatronics Engineering Professor: In our two interviews with Dr. Mackay, we verified that the Raspberry Pi microcontroller was over-powered for the task of powering one single bioreactor. He recommended either using less powerful and expensive microcontrollers for a cheaper price or using one Raspberry Pi to power multiple microcontrollers. He also encouraged us to develop an intentional power-distribution budget and plan (~300 W total for 90 bioreactors), including considering scheduling of heaters and pumps to reduce peak power demands.


Cameron Davidson-Pilon, CEO of Pioreactor: Our interview with Cameron Davidson-Pilon taught us his company prioritizes an open-source and simple design that works for both hobbyists and researchers. He commented on the regrets he had when designing the Pioreactor, including having exposed wiring, using the Raspberry Pi instead of a more user-friendly microcontroller (ESP32), and the 1:1 ratio between microcontroller and Pioreactor. These comments informed testing of our microcontroller options and requirements on parallelizability and shielding of electronics from water.


Patricia Rea, iGEM Toronto Wetlab Lead: In our interview with Patricia, we learned the importance of an interface and design that appears friendly not only to engineers but also to wet lab researchers who are less familiar with setting up microcontrollers and other electronics. Her input encouraged us to design “friend-shaped” features where possible, including in connecting to and setting up the bioreactor.

Patricia's presentation to hardware teamOpen PDF ↗

Main objective


We wanted to first define a successful architecture for our bioreactor, prototype, and test the subsystems individually as part of our V1, so that we could focus on their integration in later iterations. These initial requirements were a foundation for all future versions of the bioreactor.

Overarching requirements


Listed below were our key requirements for each subsystem during our first DBTL cycle.


SubsystemRequirements SummaryLink for More Details
CADThe arrangement of electronics and components should be optimized to prevent heat loss from the heater, spillage of media on electronic components, and ensure overall ergonomics and structural strength.View Details
Temperature ControlTemperature requirements aim to maximize temperature range, minimize time to reach a target temperature, and increase temperature stability.View Details
Power ManagementThe power supply shall be able to power all components reliably when needed and shut down in case of failure.View Details
PumpsEach pump adds a different solvent to the bioreactor solution. Pumps must provide highly controlled dosages for precise media control.View Details
ODOD600 readings can be normalized, indicate bacterial growth, and be compared with other instruments.View Details
Data & ControlsThe bioreactors shall transfer data to a central hub with a user-friendly control system capable of controlling 96 bioreactors in parallel.View Details
StirringStirring speed is limited to a range of 150–300 RPM for optimal bacterial growth.View Details

BoM


ComponentPrice (CAD)
FIT0845 heater$5.16
DFR0198 temperature probe$15.20
SRSZ-05VDC-SH relay$6.92
Adafruit 1467 thermal interface$2.14
Aluminum foil$0.08
Heater mount (Onyx, 3D printed)$2.04
USB-C PD/USB-A QC trigger board$2.79
8-port 200W multi-charger (1/8 share)$3.82
USB C-C cable$1.78
Peristaltic pump with tubing$35.18
Transistor (TIP142)$6.98
Diode (1N5819)Included in kit
Resistor (2.2 kΩ)Included in kit
Power supply (5V)Free (reused charger)
Arduino Nano$8.00
USB hub$15.55
USB-C to USB-C mini cableIncluded in kit
Photodiode (AS7343) ×2$56.26
LED$0.09
Jumper wires$0.67
Fan (Sunon MF40201V1)$17.64
Neodymium magnets$4.50
Magnetic stir bar$16.00
OD / vial holder print (V1.1)$1.07
Pump / protoboard holder print (V1.1)$0.96
Total$202.83

Equipment


ComponentPurposeCost (CAD)Sourcing Link
Super glueAdhesive for attaching neodymium magnets to the fan.$14.00View Product
USB Cable MultipackUSB connections for programming and reading from microcontrollers, as well as powering components.$19.88View Product
Circuitry KitSupplies wires, resistors, and breadboards for prototyping circuit features.$38.00 (for 2)View Product
Cable KitProvides connections between components for easy wiring, specifically STEMMA QT connectors.$12.00View Product

Subsystems

Select a subsystem to learn more about our development on it for this iteration

Main Function(s) + Requirements

Found below are general objectives for our CAD model.

RequirementPriorityWhy (are we considering this)?
Light as possible

Metrics & Criteria: <500g
HighTo be portable and easy to use, the ideal weight of the CAD model should be below what a human can comfortably pick up and hold with one hand, which is approximately 1–5kg. To account for the extra weight from other components (such as the protoboard and vial), the CAD should be half of the lowest weight.
Minimize exposed electronics

Metrics & Criteria: <75% of electronic surface
HighFor safety reasons, all housing for electronic components (sensors, LEDs, protoboards, etc.) should be enclosed as best as possible. As some electronics have wiring connecting to other places (such as the protoboard connecting to the user’s computer), some electronic exposure is required; it cannot be a completely isolated box. Additionally, all sensors and electronic components are safe to touch when powered; it is only when shorted with liquid that they become a safety hazard.
Minimize tolerance

Metrics & Criteria: <0.3mm
MediumTo ensure components do not slide or shake when using the bioreactor, the general tolerance should be low.

For specific components like the vial cap or OD sensor holders—where light contamination will drastically alter results—the tolerance must be low. As printer accuracy is 0.1–0.5mm, 0.3mm is perfectly between the tolerance threshold.
Minimize printing time

Metrics & Criteria: <6hr
LowThe average 3D print time for a small to medium CAD model ranges from 2–10 hours. As the bioreactor CAD leans towards the larger side of this range, being below 6hr is a reasonable goal. This is dependent on the infill and print speed [Note: goal is 20% infill and 110% print speed].

Found below are specific requirements for each component in the bioreactor. For stability and safety purposes, all component housings should be able to support the component weight without any hint of buckling.


ComponentRequirement/FunctionalityWhy?
Vial
Bioreactor configuration
Refer to below relationshipsDetermines where other subsystems must lie.
Reference sensor + LED
OD
Must be located across the collecting sensor and on the side of the vial.The angle between the collecting sensor and the LED needs to be 180 degrees, while the reference sensor needs to sit directly on the LED to account for environmental factors (such as LED drift).
Collecting sensor
OD
Must be located across the LED and on the side of the vial.180 degree required. See above.
Breadboard/protoboard
All subsystems
Can be located anywhereShould be a minimal distance away from electrical sensors/components so that wires do not need to extend a long distance. Other than that, there are no location constraints.
Heater
Temp control
Must maximise surface area contact with the vial but should be isolated from other components less tolerant to high temperatures.In order to minimise the power and time required to heat the vial, the surface area contact with it should be maximised.
We do not want the high temperature of the heater (up to 40C - 60C) to interfere with the performance of other components by coming into direct contact with it.
Fan
Stirring
Must be located below the vialThe stir bar sits on the vial floor, thus the fan stirring it must be able to affect the vial floor.
3 x peristaltic pumps and tubing
Pumps
Can be located anywhere, with a separate compartment for each peristaltic pump preferred.No locational relationship between the pumps and the rest of the bioreactor, however should be minimal distance from the vial to prevent long tubing.
Cap
Bioreactor configuration
On top of vialMinimal cap tolerance with the vial holder for maximum darkness, which equals minimal light contamination with OD.

BoM

V0

CAD for…SubsystemFilament (g) → Cost ($)Visual
Reference sensorOD

43.03g PLA



$1.08

Vial holder with reference sensor, LED, and collecting sensor
Collecting sensor
LED
Vial holderBioreactor
FanStirringN/AN/A
HeaterTemp control

7.34g



$1.45



*Printed using Markforged Onyx

Heater mount CAD model

V1.0

CAD for…SubsystemFilament (g) → Cost ($)Visual
Reference sensorOD

~2hr



55.7g PLA



$1.39

Vial holder and OD sensor compartments
Collecting sensor
LED
VialBioreactor

V1.1

CAD for…SubsystemFilament (g) → Cost ($)Visual
Reference sensorOD

~1.5hr



45.5g PLA



$1.07

Vial holder and OD sensor compartments
Collecting sensor
LED
VialBioreactor
3 x peristalticPumps

~1hr



37.9g PLA



$0.96

Peristaltic pump and protoboard housing
ProtoboardBioreactor

Equipment Used

  1. Prusa MK4
  2. Prusa slicer (online website)
  3. Tweezers
  4. PLA filament

Build, Assembly, Code

V#NotesPhoto
V0

Simple holder for only the vial, no dedicated compartment for OD yet (taped inside), allowing high amount of light contamination. No dedicated compartment for any subsystem either. The vial cap does not perfectly sink into the vial holder, resulting in light contamination at the top.

cad6
V1.0

Vial holder with dedicated OD compartment. However, without full encasing there is still a high amount of light contamination. The set-up however allows placing the OD sensors at different heights, avoiding interference caused by stirring.

cad7
cada
cadb
V1.1

Dedicated OD sensors with full enclosure to mitigate light contamination.

cad8
Peristaltic pump and protoboard housing