Every later measurement depends on the cassette sitting in the genome, so this goal came first and carries most of our data. It produced two results: usable amounts of all eight fragments, and His positive colonies for all three strains. A third result, a PCR that confirms the position of the cassette, has not worked yet (section 1.3).
Each of the eight fragments was amplified by PCR with KAPA Taq, cleaned on a silica column and measured on a NanoDrop. Single readings of the same tube often disagreed, so we took several readings of each sample, using 1 µL for each. Crude reactions read between about 740 and 1100 ng/µL in the first round and between 980 and 1100 ng/µL in the second. These values are not yields, because unused primers and nucleotides also absorb at 260 nm, and we used them only to check that every tube had been handled. The cleaned eluates are the working numbers (Table 1).
Table 1. NanoDrop concentrations of the eight fragments after column cleanup. The working value of the second round is the mean of the largest group of readings that agreed with each other, with a coefficient of variation of at most 15% (population standard deviation).
| Fragment | Length (bp) | Round 1 after cleanup (ng/µL) | Round 1, measured again the next day (ng/µL) | Round 2 working value (ng/µL) | A260/230, round 2 |
|---|---|---|---|---|---|
| 1 | 1473 | 69.65 to 111.35 (one failed reading of 7.1 left out) | 121.8 | 82.35 | about 0.65 |
| 2 | 1062 | 59.6 to 119.85, in two groups near 60 and near 115 | not repeated | 54.27 | 0.9 to 1.25 |
| 3 | 1598 | 109.3 to 117.7 | not repeated | 54.70 | 0.49 to 0.52 |
| 4 | 144 | 10.1 to 11.35 | 2.1 to 8.5 | not repeated, separate stock of 78.2 | not available |
| 5 | 650 | 71.8 to 76.45 | not repeated | 66.52 | 0.36 to 0.52 |
| 6 | 1437 | 30.45 to 72.45 | 102.55 | 71.05 | 1.2 to 1.5 |
| 7 | 1281 | 32.5 to 40.4 | 95.0 | 58.70 | 0.7 to 1.1 |
| 8 | 1735 | 30.8 to 39.2 | 121.3 | 37.7 | 0.2 to 0.4 |
Four points stand out.
Fragment 4, at 144 bp the shortest, came off the column at about 10 ng/µL, against 60 to 120 ng/µL for the long fragments, and it read lower still the next day. Readings this low are close to the limit of what the instrument measures reliably, and we did not establish why the recovery was so poor. Because the eluate was too dilute to use, we amplified Fragment 4 again on its own, in a separate PCR at an annealing temperature of 52.7 °C (55 °C was used for every other PCR), and eluted it in 30 µL. The new stock measured 78.2 ng/µL, taken from five readings of which two were obvious technical errors and were left out, and 25 µL remained after the measurements. This stock was used in both transformations.
Fragments 6, 7 and 8 gave low and scattered values on the evening of the first cleanup, several with distorted A260/280 ratios. When we measured them again the next day they read 102.55, 95.0 and 121.3 ng/µL, with ratios between 1.7 and 1.9, and we took the second set as the real one. Fragment 1 gave one reading of 7.1 ng/µL with a negative A260/280 ratio, which is a failed measurement and not a result, so it was measured again.
Fragment 8 was the hardest to pin down in the second round. Its four readings on the first evening ranged from 36.7 to 102.5 ng/µL, so we measured it three more times the next morning and got 84, 42 and 32 ng/µL. The largest group that agreed was 32, 36.7, 40.1 and 42 ng/µL, with a mean of 37.7 ng/µL and a coefficient of variation of about 10%. The other three readings (64.85, 84 and 102.5 ng/µL) were all higher and did not agree with each other. We used 37.7 ng/µL. That makes Fragment 8 the most dilute fragment and the one that needs the largest volume per reaction, 4.49 µL. Eighteen microliters of eluate remained, which covers one reaction per strain (13.5 µL) and little more.
The A260/230 ratios of the second round lie mostly between 0.2 and 1.5, where a clean sample reads about 2. This points to salt carried over from the binding buffer of the cleanup kit. Together the fragments added about 12 to 13 µL to a reaction of about 1 mL in the second transformation, so we judged the carryover acceptable, but the purity of these preparations should not be overstated. No fragment was run on a gel before use, so these numbers report quantity and not identity.
The three strains are built from eight fragments that recombine with each other inside the yeast cell. Fragments 1, 6, 7 and 8 are shared by all three strains, and the sensing module differs: Fragment 2 for pCUP1, Fragment 3 for pKAR2, and Fragments 4 and 5 for pSynOS4(alt1). A reaction therefore contains five fragments for pCUP1 and pKAR2 and six for pSynOS4(alt1). We aimed for 150 fmol of each fragment. The HIS3 marker sits on Fragment 1, and the recipient strain CEN.PK2-1C carries the his3Δ1 mutation, so only cells that have taken up the DNA can grow on medium without histidine.
Table 2. Fragment amounts for the second transformation. The mass for 150 fmol is calculated as 150 fmol × length in bp × 650 g/mol per bp, which is 0.0975 ng per bp.
| Fragment | Used in | Mass for 150 fmol (ng) | Concentration used (ng/µL) | Volume per reaction (µL) |
|---|---|---|---|---|
| 1 | all three strains | 143.6 | 82.35 | 1.74 |
| 2 | pCUP1 | 103.5 | 54.27 | 1.91 |
| 3 | pKAR2 | 155.8 | 54.70 | 2.85 |
| 4 | pSynOS4(alt1) | 14.0 | 78.2 | planned 1.8 of a 1:10 dilution; 1.8 of the undiluted stock was added |
| 5 | pSynOS4(alt1) | 63.4 | 66.52 | 0.95 |
| 6 | all three strains | 140.1 | 71.05 | 1.97 |
| 7 | all three strains | 124.9 | 58.70 | 2.13 |
| 8 | all three strains | 169.2 | 37.7 | 4.49 |
The first transformation carried four reactions: the three sensing strains and a control that received no DNA. Colonies appeared on the SD−His plates of all three sensing strains, more than ten per strain, although no exact count was kept. The control did not grow on SD−His, as expected for a his3Δ1 strain, and it grew normally on YPD, which shows that neither the lithium acetate and PEG treatment nor the heat shock had killed the cells.
Table 3. Outcome of the first transformation.
| Reaction | Plate | Outcome |
|---|---|---|
| pCUP1 | SD−His | more than 10 colonies |
| pKAR2 | SD−His | more than 10 colonies |
| pSynOS4(alt1) | SD−His | more than 10 colonies |
| Control, no DNA | SD−His | no growth |
| Control, no DNA | YPD | normal growth |
One deviation from the plan is worth recording. Fragment 4 should have been added from a 1:10 dilution of its stock, which would give about 14 ng. The dilution was skipped and 1.8 µL of the undiluted stock went into the reaction, which is about 141 ng, ten times the intended amount. Transformants still appeared for pSynOS4(alt1), so a ten fold excess of one short fragment did not prevent colonies from growing. For the second transformation we again added 1.8 µL of the undiluted stock, this time on purpose, which puts the total DNA of the pSynOS4(alt1) reaction at about 782 ng instead of the 655 ng that equal amounts of 150 fmol would give.
Plates were labeled by strain from the day of the transformation. That label is the only record that distinguishes the three strains at this stage, for the reason explained in section 1.3.
The second transformation repeated the integration independently, with the fragments of the second round (Table 2) and with competent cells that had been frozen after the first transformation in 100 mM lithium acetate with glycerol at minus 20 °C. Competent yeast is normally frozen at minus 80 °C, so the fraction of cells that survived was unknown. The thawed pool of about 1.8 mL was divided into five reactions of 360 µL: one for each strain and two controls that received no DNA. This attempt also gave more than ten colonies for each strain on SD−His.
To test whether the cassette sits at the HO locus, we designed a colony PCR across the left junction. The forward primer, Colony_OUT_FWD (GTAGACGTGTGTGTCTCATGG), anneals in the native genome 180 bp upstream of the insertion site, on sequence that is not part of any synthetic fragment. The reverse primer, Colony_IN_REV (TTTAAGAGCTTGGTGAGCGC), anneals at the 3′ end of Fragment 1. Neither primer can give a product alone: a free fragment has no forward primer site, and an unmodified genome has no reverse primer site. A correct integration therefore gives a single product of 1.65 kb. To release genomic DNA, a small amount of colony was heated in 20 mM NaOH at 95 °C for 10 minutes, the tube was centrifuged at 10,000 × g for 1 minute, and 2 µL of the cleared lysate was used as template in a 20 µL KAPA Taq reaction with an annealing temperature of 55 °C. An unmodified WT colony was run as a negative control.
The PCR products were run on an agarose gel, and no bands were visible. The most likely explanation is that the cells were never lysed properly, so that little or no genomic DNA reached the lysate,because they have rigid β-glucan and mannoprotein in their cell walls that can be perturbed only by mechanical grinding. Incomplete lysis, the PCR conditions, and the absence of the expected junction would each give this result, and without a control that shows the lysate can be amplified the failure cannot be assigned to one of them. Although after separate discussion with our instructor Prof. Hélène MARTIN-YKEN , with expertise in yeast morphology and cell wall synthesis and with the PhD candidate Sylvia Mangani we ended up in the same conclusion. Yeast cells are far too stable to have their walls disintegrated by vortex and shift temperature changes.
The strongest evidence we have is genetic. The HIS3 marker is on Fragment 1, the recipient strain cannot grow without histidine, and the control that received no DNA stayed blank on SD−His while growing normally on YPD. Growth of colonies on SD−His in all three strains therefore points to uptake and maintenance of Fragment 1.
Selection cannot show where in the genome the DNA sits, or whether Fragments 2 to 8 are attached behind Fragment 1. Two features of the design make a correct assembly the favored outcome. Each junction is an overlap of 25 to 60 bp shared by exactly one pair of neighboring fragments, so recombination has a single productive partner at every step. The two outer fragments carry 500 bp of homology to the HO locus, TS1 on Fragment 1 and TS2 at the end of Fragment 8, which gives the finished cassette one place to recombine. This is the principle of the multi-fragment assembly strategy of Kuijpers and colleagues (2013). It is an argument from the design and not a measurement. A colony in which Fragment 1 integrated alone, carrying the marker and the left homology arm but none of the circuit, would also grow on SD−His, and so would an insertion somewhere else in the genome.
The colony PCR is the direct test of the left junction, and it has not yet worked. Even when it does, it will not tell the strains apart, so strain identity rests on the plate labels from the day of the transformation and, later, on which stressor each strain responds to. Until a band of 1.65 kb is obtained and a response to the stressor is measured, we describe the strains as selected and consistent with correct integration, not as confirmed.
An integrated cassette that is not switched on records nothing, so this goal asks under which conditions the circuit can work at all. So far it has two results: the promoter audit, which changed the protocol of every dose response run, and a first RT-qPCR attempt, which recorded late signals for two of the three transcripts and set the conditions for the repeat.
While the dose response protocol was being finalized, we went back to the sequences of the finished constructs and checked which promoter drives which gene. In every strain TetR sits directly behind pGAL1 D12, a hybrid of the GAL1 promoter with tetO2 operators, and TIP sits directly behind the sensing promoter. Like the natural GAL1 promoter, pGAL1 D12 is switched on by galactose and held off by glucose. The same promoter also drives the reporter. Our routine SD−His medium contained glucose and no galactose. Cells grown in it would make little or no TetR and little or no reporter, and a dose response measured in that state would tell us nothing about the circuit, whatever the stressor did.
We therefore added a galactose switch before any stressor. Cells are grown in SD−His with glucose, collected by centrifugation, resuspended in SD−His with galactose and kept there for 3 hours, so that TetR can accumulate and hold the reporter down before the stress arrives. The 3 hour window comes from typical GAL1 induction times and the µM culture of each run is the internal check on it..
RNA was prepared from five experimental samples: pSynOS4(alt1) without and with 600 µM H2O2, pKAR2 without and with 2000 µM DTT, and pCUP1 with 100 µM CuSO4.
NanoDrop spectrophotometry confirmed that our extraction protocol successfully yielded RNA of adequate purity, with absorbance ratios falling within the optimal expected range. However, due to the mechanical lysis constraints in yeast, the resulting eluates were highly dilute.
To ensure statistical rigor, our experimental design mandated that every sample be measured in technical triplicates across all four target genes (UBC6, sfGFP, GB1, and TetR). To accommodate these extensive technical replicates, the limited total RNA mass had to be heavily rationed across multiple wells. This logistical bottleneck forced us to reduce the RNA input to just 20 ng per 20 µL reaction, only a fifth of the 100 ng capacity recommended for the 1-step RT-qPCR kit.
A fivefold difference in starting template mass costs approximately 2.3 PCR cycles, but more importantly, it placed the entire run below the effective sensitivity range of the assay. Because the target mRNA constitutes only a tiny fraction of the 20 ng total RNA input, there was insufficient template for the reverse transcriptase to synthesize a robust cDNA pool.
Consequently, no reaction produced a true exponential amplification curve, and the melt curves lacked the specific high-temperature peaks expected for our products. The reference gene UBC6 amplified in the unmodified WT RNA (two of three reactions, one melt peak at 78 °C) but in only one of the fifteen reactions of the experimental samples. sfGFP and GB1 gave late signals (Ct 32 to 37 in most reactions) with scattered technical replicates and melt peaks below the expected values, and TetR gave no valid peak. With so little template, the primers had almost nothing to anneal to in the early cycles, which favors self-annealing.
To empirically verify that the late Cts and noisy melt curves were artifacts of insufficient template mass rather than an enzymatic or thermal cycling failure, we analyzed 6 µL of the reaction products on a 2% agarose gel.
While the DNA ladder resolved and stained perfectly, the sample lanes were entirely blank, no specific product bands accumulated at the expected 100-120 base pair sizes. This gel electrophoresis result definitively confirmed our hypothesis: the initial 20 ng RNA input simply could not support adequate cDNA synthesis. Without a sufficient cDNA pool, no specific amplicons could accumulate to a detectable level to be stained on the gel, allowing short, non-specific structures (which run off the front of the gel) to generate the false fluorescence signals recorded by the cycler.
The first RT-qPCR attempt did not definitively answer our transcript quantification question, but it provided a crucial methodological lesson for yeast synthetic biology. The assay demonstrated that while we can achieve highly pure RNA extracts, the combination of dilute samples and the strict requirement for technical triplicates severely crippled the sensitivity of the 1-step kit.
The physical absence of bands on the agarose gel, coupled with the reported melt curves, points to a 20 ng total RNA input being too small for a dynamically expressed circuit in yeast. We therefore read the late threshold crossings as the limit of the assay and not as transcript measurements, and the UBC6 and TetR primer sets will be redesigned for the repeat.
Moving forward, securing higher RNA yields, potentially by transitioning to enzymatic spheroplasting prior to lysis, so that the maximum 100 ng of template, or as we suggest, at least 80ng of template, can be loaded per reaction is the absolute prerequisite for quantifying circuit induction. This conclusion transitions our assay limitation into a concrete, validated protocol improvement for future iterations.
This is the goal on which ICHNOS is finally judged.
Each strain is tested against its own stressor: pSynOS4(alt1) against hydrogen peroxide, pKAR2 against DTT and pCUP1 against copper sulfate. Each stressor was added as a spike 100 times more concentrated than its final dose, 2 µL to 198 µL of culture, so that the spike was 1% of the volume and did not change the medium or the cell density. The hydrogen peroxide spikes were made from a 30% stock taken as 9.8 M, which puts the true doses about 2% below the nominal values. After each reading time, a small drop of the same culture was placed on a slide. Six dose response runs of the sensing strains were carried out, and every slide was imaged in brightfield, in the sfGFP channel and in the mCherry channel, in two fields of view. The H2O2 and DTT images were analyzed by the dry lab (Model, Chapter 9) and the first results are in section 3.4. What this section records is which runs exist and under what conditions, because the numbers will have to be read against them.
Table 4. Dose response runs of the sensing strains.
| Strain | Stressor and final doses | Imaging times after dosing (min), time points | Status |
|---|---|---|---|
| pSynOS4(alt1) | H2O2: 0, 20, 75, 300 and 600 µM | 51 to 221 (5 time points) | imaged, analyzed |
| pSynOS4(alt1) | H2O2: 0, 20, 75, 300 and 600 µM, with 1 mL of culture in a 15 mL tube and 10 µL of spike | 357 to 430 (2 time points, 6 h and 7 h) | imaged, analyzed |
| pSynOS4(alt1) | H2O2: 0, 20, 75, 300 and 600 µM | 55 to 457 (4 time points) | imaged, analyzed |
| pKAR2 | DTT: 0, 100, 250, 500, 1000 and 2000 µM | 17 to 395 (6 time points) | imaged, analyzed |
| pKAR2 | DTT: 0, 100, 250, 500, 1000 and 2000 µM | 56 to 319 (3 time points) | imaged, analyzed |
| pCUP1 | CuSO4: 0, 10, 25, 50 and 100 µM | 10 to 258 (5 time points) | imaged |
The second H2O2 run used a larger volume of culture in a bigger tube because over a long incubation a small tube has too little air, and the fluorescent proteins need oxygen to mature.
The pCUP1 run matters more than its place at the bottom of the table suggests. Copper acts through a pathway entirely separate from oxidative stress and ER homeostasis, so a pCUP1 response would show that the cascade of TIP, TetR and reporter works at all, independently of the upstream biology of the other two strains.
The images were taken on an Olympus CKX41 inverted microscope with a cooled color camera (QImaging MicroPublisher 3.3 RTV, 8 bit capture), with the sfGFP signal read through the blue cube and the mCherry signal through the green cube. We have no flow cytometer, which is why the readout is microscopy.
The dry lab reviewed the acquisition records alongside the campaign and put questions back to the wet lab, which were answered. Those answers pinned down the camera offset, made the log authoritative wherever file names and clocks disagreed, and are what the analyses now read their imaging times from.
Yeast fluoresces a little on its own, and stress can change that, so without a matched measurement part of the signal of the sensing strains cannot be assigned to the reporter. We therefore exposed the unmodified strain to the same stressors as the sensing strains: H2O2 and DTT at their doses and reading times, and copper sulfate at the doses and reading times of the pCUP1 run. All three stressor runs have been imaged. H2O2 and DTT have been through the analysis pipeline; the copper run was taken as a control for the downstream cascade and sits outside the model’s scope until a copper input module exists. The unmodified cells were growing in YPD, which fluoresces itself, so they were moved into the same synthetic galactose medium used for the sensing strains.
The unmodified strain carries his3Δ1 and needs histidine, which the sensing strains do not. The medium was therefore prepared as one 20 mL base and split into two portions of 10 mL, identical apart from one addition. One portion received 100 µL of a 2 mg/mL L histidine stock, which gives 20 mg/L, the amount a complete supplement mixture contains, and the other received 100 µL of sterile water so that the dilution was the same. With no filter available, all bottles were autoclaved at 121 °C for 15 minutes with the caps loosened and combined after cooling. The cells were brought to the same OD600 range as the sensing strains, 0.5 to 0.8, and kept in galactose for 3 hours before the stressors were added. The synthetic medium is not optically dark either, since the yeast nitrogen base contains riboflavin, but this part of the background is the same in every sample.
Figure 5 shows example fields of unmodified cells without and with a stressor. The cells give a weak, scattered signal in both fluorescence channels, which is the autofluorescence the reference is meant to capture. Exposure and gain were not the same between the two rows, so the panels show morphology and the distribution of the signal within a field and cannot be used to compare brightness.
The dry lab analyzed the H2O2 and DTT images with a pipeline whose parameters were fixed before the first image was taken (Model, Chapter 9). Cells were segmented on the brightfield frames, intensities were expressed per unit of exposure time, the autofluorescence of the unmodified strain was subtracted per stressor, and every dose was compared with the 0 µM culture of the same day. On 7 October the red (mCherry) signal rose above the control by 2.0, 2.5 and 3.0 gray levels per second at 75, 300 and 600 µM H2O2 (q = 0.007 at each dose), and the share of reporter positive cells rose by 14 percentage points at 600 µM (q = 0.007). On 5 and 6 October no effect was detected, and the smallest effect those data could have shown was 0.4 to 1.0 gray levels per second. For DTT no response was detected between 100 and 2000 µM, which reaches the lower part of the modeled ER range. The 7 October signal is the clearest in our data set, and the next round is designed to confirm it (Model, Section 9.6). The copper run was imaged as a control for the downstream cascade and will be analyzed once the model has a copper input module.
The imaging record is what makes the images comparable. The camera settings were kept constant and logged (gain 3, gamma 1, offset 10 and 50), the exposure of the red and green channels was recorded for every image, and every dose is read against the 0 µM culture of the same day. Eight bit capture and widefield microscopy limit how finely intensities can be quantified, so a calibration of the imaging setup is part of the next round.
The copper run is the control that separates two kinds of problem. If the pSynOS4(alt1) and pKAR2 strains turn out flat while the pCUP1 strain responds, the sensing promoters are the more likely cause. If all three are flat, the cascade of TIP, TetR and reporter is the first thing to examine. Copper-exposure images are assessed relative to their corresponding image background. Additional images of the unmodified strain under copper sulfate exposure have been collected for control comparison.
Recording when a stress happened, and not only how strong it was, is what makes ICHNOS a dual biosensor and not only a reporter. This goal has a design and an image set behind it.
Every slide was imaged in both the sfGFP and the mCherry channel, so the raw material for the timing readout has already been collected. The two fluorescent proteins in the timer mature at different rates, so their ratio reports the age of the reporter population while the absolute intensities report its amount. Two conditions have to be met before the ratio can be read as a clock, and neither is met yet. The optical calibration that the tandem timer model of Khmelinskii and colleagues (2012) requires, for example with mother and bud cells, has not been done, so the ratio is for now a relative number without a time axis. And because the two fluorescent proteins sit in the same fusion protein, energy transfer between them lowers the sfGFP signal by an amount that we cannot correct without strains that carry the two proteins separately, which we do not have.
The timer is the part of ICHNOS with the furthest to go. Nothing collected so far is wasted, because both channels were recorded in every sample, and a calibration made later can be applied to images that already exist. What we created is a reference frame, in the form of a decoder, that turns a ratio into an elapsed time. Two things are needed and both can be built: a calibration of the optical system, and a pair of control strains that express the two fluorescent proteins separately, so that the energy transfer can be measured and not assumed. The dose response runs vary the intensity of the stress at a fixed time of exposure, and they do not vary when the exposure happens. Supporting the timing claim properly needs an experiment where the exposure itself varies, a pulse of stress followed by removal of the stressor, read out at several points after the pulse ends, with the stressed culture held alongside an unstressed one imaged on the same day. That experiment was not run, and time was the reason. The timing mechanism is sound by design and the reporter was built to deliver it, so what the claim is short of is evidence rather than a working principle: even more runs, and the controls that make them comparable.
The evidence so far is mostly genetic and selective. The first RT-qPCR recorded late signals for sfGFP and GB1, but its reference gene amplified in only one of five samples, so it does not yet say whether the circuit responds. Growth on SD−His in all three strains, with a negative control that stayed blank, shows that the HIS3 marker on Fragment 1 was taken up and maintained. Transformants were obtained with the 150 fmol design, and the one accidental ten fold excess of Fragment 4 did not prevent them. What selection cannot show is where the cassette sits or how much of it is present.
Table 5. Claims, the evidence we have, and what would settle each one.
| Goal | Claim | Evidence now | What would settle it |
|---|---|---|---|
| 1 | HIS3 was taken up and is maintained | growth on SD−His in three strains, control negative | established by the plates |
| 1 | The cassette sits at the HO locus | none, the colony PCR gave no bands | a successful junction PCR |
| 1 | Fragments 2 to 8 are joined behind Fragment 1 | design constraints only: unique overlaps and 500 bp homology arms | transcript measurements, a dose dependent response and sequencing |
| 2 | The three transcriptional units are expressed | late signals for sfGFP and GB1 (Ct 32 to 37 in most reactions); no valid TetR signal; the reference gene UBC6 amplified in only one of five samples | a working reference gene on the same RNA, or a standard curve, and a TetR assay that gives one product |
| 2 | The reporter is repressed before the stressor arrives | galactose switch applied, hold time not verified | the zero dose signal, once the images are quantified |
| 3 | The reporter responds to its stressor by dose | six runs imaged; H2O2 and DTT runs analyzed: dose ordered red signal under H2O2 on 7 October (q = 0.007), no DTT response up to 2000 µM; copper run imaged | a repeat of the H2O2 ladder with a time course, and DTT doses above 2000 µM |
| 4 | The ratio of the two channels reports elapsed time | both channels recorded, no time axis | optical calibration, separate fluorophore strains, a pulse and release experiment |
Four further limits apply to anything built on these strains. The fragments were amplified with KAPA Taq, which has no proofreading activity, and the integrated cassette has not been sequenced, so point mutations cannot be excluded. No fragment was run on a gel before use, so fragment identity rests on the primer design, the yield after cleanup and the fact that transformants were obtained. The binding affinity between TIP and TetR was estimated computationally (3.675 and 8.428 nM, from PRODIGY on the experimental structure 2NS8) and has not been measured, so the fitted curves will be read with that in mind. And fluorescence is read by widefield microscopy and not by flow cytometry, so cell numbers are small and cell to cell variation is estimated more noisily than cytometry would allow. The ratio of the two channels is used as a relative quantity only, because the optical calibration of the timer model has not been done.