Project Description

Overview

ICHNOS demonstrates how synthetic biology can create the next generation of biological sensors that don't just react to the present environment, but actively remember their biological past. Our modular tool, Ichnos-Vail, translates a lasting biological footprint into a readable output, helping researchers estimate the magnitude and timeframe of past cellular events.

What is the problem?

Patras Medicine iGEM 2026 aims at a clear biological problem, the unrecorded history of Cellular stress. Cellular stress is a universal phenomenon as cells are constantly exposed to a wide spectrum of environmental and internal stressors. These range from oxidative damage, endoplasmic reticulum (ER) stress and heat shock, to metabolic depletion, hypoxia, genotoxic and mechanical stress. When cells undergo these stress events, it can severely alter their viability, morphology, and overall functionality.

Cells exposed to a wide spectrum of stressors Cells exposed to a wide spectrum of stressors

Once a cell survives a transient stressor, the immediate biological signals fade, and the cell eventually returns to a seemingly normal state. This recovery, while biologically necessary, leaves no accessible record of what the cell experienced, how intensely it suffered, or when the event took place. This missing piece of information means that not only have we lost data but also context, leaving us unable to understand why a cell is behaving in a certain way, why an experiment worked or failed or the reason that a scientist fails while trying to replicate the results of an experiment using the same methods.

This creates a critical, systemic blind spot in modern science. We are fundamentally unable to capture and decode the hidden timeline of cellular stress. Because we cannot track this history, researchers and industries are forced to work with cell cultures that appear healthy in the present, while remaining completely blind to their past. Ultimately, the core problem is not the cellular stress itself, but our scientific inability to detect and decode it, resulting in profound lack of insight into the true biological state of the cells we use.

The actual impact

As cellular stress is deeply intertwined with fundamental cellular mechanisms, the undetected presence of stress events acts as a silent barrier holding back global scientific progress. Cells are often treated as blank slates, but in reality, they carry a hidden history. A cell culture that has previously experienced and survived a stress event may appear perfectly healthy under a microscope, yet its molecular landscape, epigenetic state, and responses to treatments are fundamentally altered.

Because conventional assays capture only a static snapshot of the present, they completely miss this temporal sequence of events. When this hidden cellular history goes unrecorded, it directly fuels a massive, systemic crisis in experimental reproducibility, a crisis where an estimated 53% of all preclinical research cannot be replicated.[1] Continuous exposure to unrecorded microenvironmental stressors in vitro dramatically alters cellular transcriptomes, causing cells from the exact same line to exhibit highly variable drug responses and unpredictable behaviors.[2][3] Researchers unknowingly utilize biological materials with undocumented stress histories, leading to unreliable data and false conclusions. The financial toll of experimental failures is estimated at 90 billion dollars globally each year, including 10-20 billion euros in Europe alone. Ultimately, however, the true cost transcends economics. While cellular stress is not the sole cause of this crisis, the inability to standardise and record the stress history of biological samples remains a huge contributing factor. Ultimately, this unrecorded variability derails clinical trials, introduces months of delay in R&D timelines, and keeps the scientific community from achieving critical breakthroughs.[4][5][6]

The cost of irreproducible research The cost of irreproducible research

Beyond experimental barriers, the inability to track unrecorded cellular stress causes catastrophic malfunctions across both industrial biomanufacturing and personalized medicine. In commercial biopharma, cell lines subjected to metabolic fluctuations inside massive 10,000 to 20,000-liter bioreactors frequently struggle with protein misfolding, leading to a major batch failure on average every 40.6 weeks[7]. Destroying 14 to 21 days of continuous cultivation, a single failed batch costs facilities between $1 million and $2 million in wasted materials, labor, and downtime[8]. The consequences are even more devastating in personalized autologous cell therapies (such as CAR-T), where cumulative ex vivo stress drives batch failure rates exceed 10%[9]. In such scenarios, a batch failure goes beyond financial loss. Depriving patients of a $500,000 personalized treatment demonstrates that our blindness to cellular history costs both millions of dollars and human lives.

Batch failures in biopharma manufacturing Batch failures in biopharma manufacturing
The financial cost of batch failures The financial cost of batch failures

Furthermore, cellular stress lies at the core of severe human pathologies. Tumors frequently hijack stress pathways to survive and develop chemoresistance[10], while in neurodegenerative disorders, chronic ER stress and misfolded proteins trigger irreversible neuronal death[11]. Finally, the progressive inability to resolve stress over time is a major driver of cellular aging.[12]

Cancer Cancer
Cancer: how cellular stress contributes Cancer: how cellular stress contributes
Neurodegeneration Neurodegeneration
Neurodegeneration: how cellular stress contributes Neurodegeneration: how cellular stress contributes
Cell aging Cell aging
Cell aging: how cellular stress contributes Cell aging: how cellular stress contributes

Current Sensors

While established methods for detecting cellular stress exist, they fundamentally act as static "snapshots," capturing the cellular state only at the exact moment of measurement. These conventional methodologies generally fall into three categories, each severely restricted by its transient nature:

  • Chemical Probes and Fluorescent Dyes (e.g., DCFDA for ROS): Although widely used for rapid detection, chemical dyes are strictly single-use and are unviable for continuous, long-term monitoring.[13]
    Chemical probes and fluorescent dyes Chemical probes and fluorescent dyes
  • Endpoint Assays (Transcriptomics & Western Blots): They require cell lysis, destroying the biological sample, yielding a static dataset strictly representative of the exact moment of extraction.[14]
    Endpoint assays Endpoint assays
  • Genetically Encoded Fluorescent Biosensors (e.g., roGFP, FRET-based sensors): Their mechanisms rely on reversible state changes. Once the stressor is removed, the signal rapidly dissipates. Furthermore, simple promoter-reporter fusions suffer from nonlinear signal saturation, making it impossible to quantify the true magnitude of the stress event.[15]
    Genetically encoded fluorescent biosensors Genetically encoded fluorescent biosensors

Unlike ICHNOS, all of the above approaches fundamentally lack biological memory. By only detecting a signal while the stress is actively present, they leave the scientific community entirely blind to the cell's history, unable to determine if a culture was stressed even a few generations ago. This critical blind spot necessitates a novel approach like ours, which successfully converts a transient stress signal into a durable, measurable, and independent record of the cellular past.[16]

ICHNOS: Introducing "Memory" in biological systems

The name of our project "ICHNOS" derives from the greek word "ΊΧΝΟΣ" meaning "trace". ICHNOS is a protein-based synthetic biology platform designed to enable cells to record traces of previous cellular stress events. Instead of functioning as a conventional biosensor that only detects a signal while it is present, ICHNOS aims to introduce a form of cellular memory, converting transient stress signals into a detectable, measurable and interpretable output.

Our Design

To achieve a reliable biological memory, we utilized Saccharomyces cerevisiae as our chassis. We chose this highly characterized eukaryotic model to ensure that our findings accurately reflect conserved stress pathways, making our platform adaptable to broader and more complex eukaryotic systems in the future.

Our final tool is a comprehensive genetic circuit designed to record the exact type, intensity, and timing of a past stress event. To accomplish this, the mechanism is structured into a cohesive, step-by-step modular architecture:

The Sensing Module

This first layer acts as the environmental interface. In our primary proof-of-concept, we studied two major types of cellular stress: oxidative stress and proteotoxic (ER) stress, utilizing the Yap1–SyNOS4_alt1 and Hac1-KAR2 pathways, respectively[17][18]. Furthermore, to demonstrate the platform's capacity to be induced by entirely distinct environmental conditions, we incorporated the copper-inducible pCUP1 promoter as an orthogonal control[19]. We chose these specific responsive elements to ensure that the system activates reliably, robustly, and with high specificity only when the cell genuinely undergoes the targeted event, preventing false-positive memory generation.

The Sensing Module: Yap1, Hac1 and pCUP1 responsive promoters The Sensing Module: Yap1, Hac1 and pCUP1 responsive promoters

The Signal-Processing Module

Natural biological stress responses are highly non-linear (sigmoidal) acting like on/off switches and saturate quickly, hiding the true magnitude of the event. To solve this, we engineered and modeled a dose-linearization circuit based on a TetR negative feedback loop[20]. When the sensing promoter fires, it drives the production of the TIP peptide. We evaluated the binding affinity between many TIP sequences and after modeling optimization chose the specific TIP/TetR pair because they possess a remarkably high binding affinity. TIP effectively binds and inactivates the TetR repressor. As TetR is inactivated, the system gradually "unlocks" the final reporter pGAL1-D12.

The TetR negative feedback loop and the TIP peptide The TetR negative feedback loop and the TIP peptide

By modeling and implementing this negative feedback, we successfully reduced the system's effective Hill coefficient, ensuring a proportional, linearized output[20]. This allows researchers to accurately quantify the intensity of the stress.

Linearization of the dose response by the TetR negative feedback loop Linearization of the dose response by the TetR negative feedback loop

The Temporal Module

To track the time elapsed since the stress event, the final readout of our circuit is a Tandem Fluorescent Timer. This consists of two fused fluorescent proteins: a fast-maturing GFP and a slow-maturing mCherry. We chose these specific fused fluorophores for two primary reasons. First, green and red fluorescence are easily distinguishable and widely supported by standard laboratory microscopy equipment. By relying on these universally familiar fluorophores, we maximize user-friendliness, ensuring that the broader scientific community can easily adopt and integrate our system. Second, and most importantly, they exhibit drastically different maturation times[21]. Because mCherry matures slowly over time, while sfGFP matures almost immediately, their Red / Green (R/G) ratio changes predictably. This ratio functions as an independent biological clock, completely decoupling the intensity of the stress from its timing. By coupling this biological sensor with our custom image-analysis software, researchers can automatically process these fluorescent signals to receive both the exact stress magnitude and the time elapsed as a direct, interpretable output.

Working in Tandem

Ultimately, these modules transform a fleeting biological reaction into a durable, interpretable footprint. The sensing layer captures the "what" (stress type), the TetR feedback loop and the tandem timer reveals the "how much" (intensity) and "when" (then stress happened). Together, they form a unified tool that allows researchers to read a cell's hidden history long after the stressor has dissipated.

Our Platform’s Modularity: From Biological Design to Computational Analysis

ICHNOS was designed as a foundation for investigating cellular stress history across different sensing contexts. Its modular architecture connects a condition-responsive Sensing Module to a shared Signal-Processing Module and Temporal Reporter Module. We applied this design principle to oxidative and ER stress, using different upstream promoters while retaining the downstream TIP–TetR regulatory and tandem fluorescent reporter architecture.

This separation provides a route towards adapting the platform to additional inputs. Future researchers could investigate a promoter responsive to their condition of interest while building on the existing downstream design. Each extension would require characterisation of promoter activity, compatibility with TIP–TetR regulation and reporter behaviour in the chosen host.

The fluorescent reporter connects the biological platform to its computational analysis. Our modelling framework describes how sensing, regulation and reporter maturation shape the signals. ICHNOS-tool provides workflows for processing microscopy images, extracting per-cell fluorescence measurements, comparing observations with model predictions and evaluating dose-and-time inference. ichnos_vail is the local application interface through which researchers can run these workflows and inspect their results.

Together, the biological architecture, modelling framework and analysis software provide a reusable basis for iterative development. The software reports uncertainty and validation limits when the available measurements do not support an estimate. This enables subsequent teams to build on both the circuit design and the computational workflow, testing new sensing inputs while progressively strengthening the interpretation of cellular stress history.

Empty promoter socket
The ICHNOS biosensor body

Making the next step

Throughout our project, we have actively explored the immediate applications of ICHNOS across diverse sectors, including agriculture, cosmetics, biomanufacturing, and food and nutrition. However, because our platform is inherently modular and scalable, this is only the beginning.

Looking ahead, we envision ICHNOS expanding into critical areas such as therapeutics, oncology, diagnostics, infectious diseases, and bioremediation. By providing a reliable system to record cellular history, our goal is to empower researchers in these disciplines to leverage our innovation, overcome current experimental limitations, and profoundly advance their respective fields.

Overall, ICHNOS offers a fundamentally new way to understand not only what a cell looks like at a given moment, but also what it has experienced in the past.

By unlocking this hidden biological history, ICHNOS can serve as a foundational tool to help researchers find answers to questions we have not even thought to ask yet.

References

  1. L. P. Freedman et al., "The Economics of Reproducibility in Preclinical Research," PLOS Biology, https://journals.plos.org/plosbiology/article?id=10.1371/journal.pbio.1002165
  2. U. Ben-David et al., "Genetic and transcriptional evolution alters cancer cell line drug response," Nature, https://pmc.ncbi.nlm.nih.gov/articles/PMC6522222/
  3. M. Baker, "1,500 scientists lift the lid on reproducibility," Nature, https://www.nature.com/articles/533452a
  4. K. D. Cobey et al., "Biomedical researchers' perspectives on the reproducibility of research," PLOS Biology, https://journals.plos.org/plosbiology/article?id=10.1371%2Fjournal.pbio.3002870&utm
  5. Bio-Rad, "Are Costly Experimental Failures Causing a Reproducibility Crisis?," Bio-Rad, https://www.bio-rad.com/en-gr/applications-technologies/are-costly-experimental-failures-causing-reproducibility-crisis?ID=4ab22faf-bef3-cf71-fb92-2d603980d393&utm
  6. Y. Liu et al., "Multi-omic measurements of heterogeneity in HeLa cells across laboratories," Nature Biotechnology, https://www.nature.com/articles/s41587-019-0037-y
  7. E. S. Langer, "Biotech Facilities Average a Batch Failure Every 40.6 Weeks," BioProcess International, https://www.bioprocessintl.com/bioanalytical-methods/biotech-facilities-average-a-batch-failure-every-40-6-weeks
  8. B. Kelley, "Industrialization of mAb production today and tomorrow," mAbs, https://pmc.ncbi.nlm.nih.gov/articles/PMC2759494/
  9. L.E.K. Consulting, "Autologous Cell Therapy: Key Challenges and Bioprocessing Innovations," L.E.K. Consulting, https://www.lek.com/insights/diagnostics-tools-and-personalized-medicine/autologous-cell-therapy-key-challenges-and
  10. X. Chen and J. R. Cubillos-Ruiz, "Endoplasmic reticulum stress signals in the tumour and its microenvironment," Nature Reviews Cancer, https://pubmed.ncbi.nlm.nih.gov/33214692/
  11. C. Hetz and S. Saxena, "ER stress and the unfolded protein response in neurodegeneration," Nature Reviews Neurology, https://pubmed.ncbi.nlm.nih.gov/28731040/
  12. C. López-Otín et al., "The hallmarks of aging," Cell, https://www.cell.com/cell/fulltext/S0092-8674(13)00645-4?_returnURL=https%3A%2F%2Flinkinghub.elsevier.com%2Fretrieve%2Fpii%2FS0092867413006454%3Fshowall%3Dtrue
  13. B. Kalyanaraman et al., "Measuring reactive oxygen and nitrogen species with fluorescent probes: challenges and limitations," Free Radical Biology and Medicine, https://pubmed.ncbi.nlm.nih.gov/22027063/
  14. D. Muzzey and A. van Oudenaarden, "Quantitative time-lapse fluorescence microscopy in single cells," Annual Review of Cell and Developmental Biology, https://pmc.ncbi.nlm.nih.gov/articles/PMC3137897/
  15. A. J. Meyer and T. P. Dick, "Fluorescent protein-based redox probes," Antioxidants & Redox Signaling, https://journals.sagepub.com/doi/10.1089/ars.2009.2948?url_ver=Z39.88-2003&rfr_id=ori:rid:crossref.org&rfr_dat=cr_pub%20%200pubmed
  16. D. R. Burrill and P. A. Silver, "Making cellular memories," Cell, https://pmc.ncbi.nlm.nih.gov/articles/PMC2882105/
  17. L. C. Dacquay and D. R. McMillen, "Improving the design of an oxidative stress sensing biosensor in yeast," FEMS Yeast Research, https://pmc.ncbi.nlm.nih.gov/articles/PMC8088429/
  18. D. Pincus et al., "BiP binding to the ER-stress sensor Ire1 tunes the homeostatic behavior of the unfolded protein response," PLoS Biology, https://pmc.ncbi.nlm.nih.gov/articles/PMC2897766/
  19. D. J. Thiele, "ACE1 regulates expression of the Saccharomyces cerevisiae metallothionein gene," Molecular and Cellular Biology, https://pubmed.ncbi.nlm.nih.gov/3043194/
  20. D. Nevozhay et al., "Negative autoregulation linearizes the dose-response and suppresses the heterogeneity of gene expression," Proceedings of the National Academy of Sciences, https://pmc.ncbi.nlm.nih.gov/articles/PMC2654390/
  21. A. Khmelinskii et al., "Tandem fluorescent protein timers for in vivo quantification of protein dynamics," Nature Biotechnology, https://www.nature.com/articles/nbt.2281