Model

Introduction

ICHNOS is a modular synthetic biology platform built to preserve a readable trace of past cellular stress. Developed in Saccharomyces cerevisiae, it is designed to convert transient stress responses into fluorescent signals that support estimation of stress intensity and elapsed time. Our proof of concept focuses on oxidative and endoplasmic reticulum stress, linking stress-responsive promoters to a shared signal-processing and reporting architecture.

In a nutshell

Input
A stress event (H2O2 or DTT, dose and exposure history).
Output
Green, red and red/green fluorescence over time, from which dose and elapsed time are estimated where the data support an estimate.
Key assumptions
Deterministic single-cell model; sensing parameters fitted to literature data; constant stress unless a clearance rate is stated.

To investigate how this architecture records and retains information, we developed an integrated mathematical model connecting three modules: stress sensing, TIP–TetR autoregulation, and a tandem fluorescent timer. Stress-induced TIP binds TetR releasing it from the operator and relieving repression of the reporter, while TetR negative autoregulation is intended to linearise the dose response. The different maturation kinetics of sfGFP and mCherry provide a time-dependent fluorescent readout.

Our modelling framework evaluates how sensor dynamics, binding affinity, feedback regulation, and fluorophore maturation influence circuit performance. Sensitivity and ablation analyses identify design dependencies and experimental priorities, while joint dose–time information analysis examines the limits of reconstructing stress history from fluorescence. Together they guide circuit development and calibration, while identifying conditions under which intensity and timing remain coupled. By retaining a common downstream architecture, ICHNOS aims to provide a reusable framework for recording cellular events through interchangeable sensing modules.

The model connects three modules:

Sensing cellular stress

ICHNOS uses stress-responsive promoters in Saccharomyces cerevisiae to detect oxidative and endoplasmic reticulum stress through the Yap1 and Ire1–Hac1 pathways. These responses drive TIP production, connecting cellular stress to the downstream circuit. Their activation and adaptation determine how the stress event is transmitted over time.

Shaping the dose response

TIP binds and inactivates TetR, relieving repression of the fluorescent reporter. TetR negative autoregulation is intended to make the dose response more nearly linear, supporting discrimination between stress intensities. The behaviour of this module depends on binding affinity, protein production and turnover.

Reading the fluorescent trace

The reporter combines fast-maturing sfGFP with slower-maturing mCherry in a tandem fluorescent timer. Their different maturation kinetics generate a changing red-to-green fluorescence ratio. Interpreting this trace requires accounting for reporter production and loss, as well as the potential coupling between stress dose and elapsed time.

One result shaped the wet lab directly: the information analysis moved the planned readout from three hours to about one, and the H2O2 sampling times were chosen from it.

Objectives

Recording a fluorescent trace is only the first step. To interpret it, we need to know how stress history shapes the signal, which circuit features preserve useful information about it, and whether different combinations of dose and elapsed time can be distinguished.

We organised our modelling around four questions:

  1. Question 01 Which model describes the stress response?
  2. Question 02 Which circuit components carry dose discrimination and temporal information?
  3. Question 03 Under what conditions can stress dose and time since onset be inferred jointly?
  4. Question 04 Which measurements would constrain what remains uncertain, and when should the reporter be read?

These questions connect model construction to circuit evaluation, decoding analysis and experimental design. Each section below answers one of these.

1. Methods

This chapter describes how the model was built and why it took the form it did. It sets out the decision that shaped everything downstream, the move from a static description of stress sensing to one with internal dynamics, together with the comparisons used to test whether that change was justified. The diagram below gives the workflow connecting the individual modules to the integrated model, the analyses that evaluate it and the software tool that applies it to microscopy data.

From static sensing to PULSE

The pivot

A central modelling decision changed how we represented stress entering the circuit. Our initial framework used a static Hill relationship to convert stress dose directly into a TIP production rate, while the downstream regulatory and reporter modules evolved dynamically. This provided a reference for dose–response analysis and reporter maturation, but it could not reproduce transient sensor activation under constant stress: the sensing layer contained no internal state, so its output could not rise and fall while the input was held fixed.

We therefore introduced explicit activation and feedback states in both sensing branches. The oxidative formulation was motivated by Yap1 activation and negative feedback through the thioredoxin system; the ER formulation by Ire1/Hac1 signalling and homeostatic feedback involving Kar2/BiP. These reduced models represent sensor activation and adaptation without reproducing every molecular step of either pathway. The resulting PULSE framework connects each adaptive sensor to the shared TIP–TetR regulatory module and tandem fluorescent reporter.

Sensor adaptation and input history are separate assumptions, and we kept them separate. The canonical oxidative model holds the stress input constant while representing intracellular feedback. Declining effective-input histories are examined on their own in the physics-informed analysis and are not treated as established chemical-clearance mechanisms.

Whether this change improved the circuit was then tested rather than assumed.

What the pivot cost and what it gained

The ablation analysis exposed a trade-off. At matched production gain, the static oxidative sensor produced a larger reporter-output range across doses than PULSE, 4.69-fold versus 2.69-fold, and a lower fitted Hill coefficient, approximately 1.70 versus 1.97. Adaptive sensing therefore did not improve dose-response performance universally.

Dose response is not the criterion that decides the question, however, because the deliverable is a joint estimate of dose and time since onset. Under the ablation study's assumed noise model and a population of 100 cells, the timing-bound advantage of PULSE over the static configuration was approximately 4.9-fold across 0.5–2 h, reducing to approximately 1.3-fold after matching production gain. These are model-based precision bounds, not experimentally demonstrated decoding accuracy.The advantage is time-dependent, and at matched gain the static configuration performed better on other measures, including dose accuracy at every age and timing beyond about 2.5 hours.

Sensor adaptation does not imply a matching TIP pulse. Under sustained input, free TIP can remain elevated even after sensor activation declines. In the tested oxidative ablation, changing partial to perfect adaptation had little effect on the fitted dose-response Hill coefficient, whereas removing adaptation produced a larger change. This result supports examining sensor structure explicitly, while leaving its consequences conditional on the selected parameters, observables and simulation protocol.

We kept the adaptive formulation, for a structural reason before a numerical one: a static Hill cannot produce the transient that Delaunay et al.1 measured, since a sensor with no internal state cannot rise and fall while the input is held fixed. The timing advantage follows from the same property, as rate of change is what carries time information and a plateau says nothing about when it was reached. The cost is dose accuracy and late-window timing, and every kinetic parameter of the adaptive motif is non-identifiable from the available data. The forward model is therefore kept swappable in the software rather than hard-coded, so the choice can be revisited when a longer time course exists.

Chassis adaptation
Investigating TIP–TetR affinity uncertainty
Evaluating model assumptions and information content
Translating modelling into a usable tool

2. Building the individual modules

2.1 TIP–TetR binding

In a nutshell

Input
TIP production from the stress-sensing module.
Output
Promoter activity controlling TetR and tandem reporter expression.
Key assumption
TIP-bound TetR does not contribute to promoter repression.

Structural exploration of the TIP–TetR interaction

We investigated the structural basis of TIP–TetR recognition. This analysis addressed two complementary questions: which binding arrangements were supported by computational predictions, and whether peptide substitutions could suggest candidates for further characterisation.

The work combined structure prediction, docking, exploratory mutational analysis and subsequent inspection of an experimental TIP–TetR complex. The experimental structure provided a reference for reassessing earlier predictions2, while the dynamical model established why uncertainty in binding affinity mattered for circuit behaviour.

Structure prediction, docking and peptide variants
Initial structural models

The early workflow used ColabFold to generate structural models of the TetR construct, the free TIP peptide and the TIP fusion protein (TIP, GB1 and the SV40 NLS)3. These models provided starting configurations for investigating the interaction; they were not treated as experimental structures.

Candidate binding arrangements were explored using HADDOCK and ClusPro45, with additional docking and co-folding approaches examined during the broader affinity investigation. The workflows suggested a binding region but did not establish a unique peptide pose. Subsequent comparisons identified substantial differences in orientation, highlighting the limitations of interpreting docking scores as evidence of a single binding geometry.

Docked poses of the TIP peptide on TetR, showing that different docking workflows place the peptide in the same region but in markedly different orientations.
Figure 2.1. Structural basis of TetR allosteric derepression by the synthetic TIP peptide. Computational prediction rendered in PyMOL.
Exploratory mutational analysis

Using a ClusPro-derived complex as the structural template, we generated the 19 alternative amino-acid substitutions at the peptide’s initial methionine position with the PyMOL Mutagenesis Wizard. Their predicted effects on binding affinity wereassessed using mCSM-PPI26.

The initial screen assigned small favourable predicted changes to tryptophan and tyrosine substitutions and an unfavourable change to proline. These results supplied candidate hypotheses rather than an experimentally validated ranking. Because the calculations depended on the selected docking template, uncertainty in that template also affected interpretation of the mutation scores.

The predictions were compared with published peptide-variant functional data7. However, functional induction and binding affinity are different quantities, and differences in constructs and experimental conditions limit direct comparison. The screen therefore did not establish an optimal TIP variant for the implemented circuit.

Reassessment using the experimental complex

Later analysis used the experimental TIP–TetR structure, PDB 2NS8, to inspect the interaction in its dimeric context2. Contact analysis showed that the peptide interface involved both TetR monomers, prompting reassessment of earlier predictions made with a monomeric receptor.

Affinity calculations on the two crystallographic peptide–dimer assemblies yielded the recorded energy estimates of −11.2 and −11.7 kcal/mol, corresponding to approximately 8.428 and 3.675 nM at 30 °C. These are computational estimates obtained from experimental coordinates, not measured dissociation constants.

Bar charts comparing the binding free energy and Kd of a single TetR monomer against the two 2NS8 dimer assemblies. The monomer is about 2.9 kcal/mol weaker, roughly 110-fold in Kd.
Figure 2.2 — Cost of scoring an incomplete receptor. PRODIGY estimates for TIP against a single TetR monomer and against the two crystallographic dimers of 2NS8.

This distinction separates the contributions of the approaches: docking explored candidate arrangements, mutational analysis generated sequence-level hypotheses, and the crystal structure supplied an experimental reference for the interface. The resulting affinity estimates and their assumed uncertainty were subsequently evaluated through the circuit simulations described in the dedicated binding-affinity analysis.

Connecting stress sensing to reporter expression

The TIP–TetR module translates TIP production into a change in reporter expression. Free TetR represses the pGAL1-D12 promoter, following the regulatory architecture investigated by Nevozhay et al. (2009)8. TIP acts as a peptide inducer of TetR through an allosteric mechanism characterised structurally by Luckner et al. (2007)2. In our model, TIP binding reduces the pool of active repressor and increases promoter activity.

TetR and the reporter are expressed from identical copies of the regulated promoter. Derepression therefore also increases TetR production, establishing a negative autoregulatory loop. This design follows the shared-promoter feedback architecture studied by Nevozhay et al. (2009)8, while replacing the small-molecule inducer with sensing-dependent TIP production.

We represented this feedback explicitly to examine how it shapes the response of the proposed circuit.

Representing binding and feedback

We constructed an ordinary differential equation model that tracks free TIP, active TetR and the inactive TIP–TetR complex. Association and dissociation follow mass-action kinetics, while production and loss processes determine the evolution of each pool. Binding is represented as an effective 1:1 interaction, without explicitly resolving all molecular binding states.

A Hill repression function relates free TetR concentration to promoter activity, P(t). This function includes a basal-expression term, allowing residual activity under strong repression. The same P(t) regulates TetR production and, upon integration, tandem reporter production.

The model distinguishes two parameters with different roles: the TIP–TetR dissociation constant describes peptide–repressor binding, whereas the effective repression threshold describes how free TetR controls promoter activity. The dedicated analysis of binding-affinity uncertainty is presented in Chapter 6.

Full mathematical formulation

We describe TIP–TetR regulation using three concentration variables in a fixed-volume compartment:

Symbol SBML species name Description Unit
x(t) TetR_active Free, DNA-binding TetR nM
y(t) TIP Free TIP nM
w(t) TetR_TIP_complex Inactive TIP–TetR complex nM

Time is expressed in hours. The binding reaction is represented as an effective 1:1 interaction:

TIP + TetRactive b⇌uw TetR·TIP

Its net association flux is:

vbind = b x y − uw w

Here, b is the association-rate constant and uw is the dissociation-rate constant. The SBML defines:

uw = b Kd,TIP–TetR

Thus, varying affinity at fixed b changes the dissociation rate. This binding constant is distinct from the promoter-repression parameter KR.

Promoter activity and TetR autoregulation

Free TetR determines the dimensionless promoter activity:

P(t) = Pmin + (1 − Pmin) 1 1 + (x/KR)n

Here, Pmin is residual promoter activity, n is the repression Hill coefficient and KR is the concentration at which the variable part of promoter activity is half-maximal:

P(KR) = 1 + Pmin 2

The function approaches 1 as free TetR approaches zero, and Pmin at high free TetR. It is an effective regulatory relationship; DNA-bound promoter states are not represented explicitly.

TetR production occurs at rate:

vTetR production = aTetR P(t)

Increasing free TetR therefore reduces its own production, establishing negative autoregulation. The reporter uses the same promoter-activity term after integration.

Binding-module dynamics

The uploaded binding SBML defines:

dxdt = aTetR P(t) − b x y + uw w − (kdeg,TetR + μ) x

dydtbinding = −b x y + uw w

dwdt = b x y − uw w − (δw + μ) w

Association consumes free TIP and TetR; dissociation returns both species. Complex removal eliminates the bound pool without releasing free components. Growth-associated dilution, μ, is included once in each specified loss term.

The binding SBML contains no independent production or loss reaction for free TIP. These processes enter through the sensing module.

TIP dynamics after integration

For sensing branch j, representing either OX or ER, TIP production is:

Cj(t) = βbasal,j + (βmax,j − βbasal,j) Aj(t)

Here, Aj(t) is the adaptive sensor’s activation state. The complete free-TIP equation becomes:

dydt = Cj(t) − b x y + uw w − (kdeg,TIP + μ) y

The integration maps sensing-module TIP onto the existing free TIP pool, so production, loss and binding act on one shared variable.

Balance checks

Adding the free and bound TetR equations cancels the reversible binding terms:

d(x + w)dt = aTetR P(t) − (kdeg,TetR + μ) x − (δw + μ) w

Likewise, in the integrated model:

d(y + w)dt = Cj(t) − (kdeg,TIP + μ) y − (δw + μ) w

These balances show that binding redistributes the free and complexed pools, while production and loss change their totals.

Parameterisation and implementation

We used literature-informed starting values where appropriate and distinguished them from parameters requiring calibration. Nevozhay et al. (2009)8 provided a reference for the TetR regulatory architecture and selected model parameters. However, their inducer was anhydrotetracycline (ATc), so inducer-binding kinetics cannot be treated as direct measurements of the TIP–TetR interaction.

The effective repression threshold and basal promoter activity were revised after reviewing their source assignments. These values define the reference model configuration rather than measurements of the constructed ICHNOS circuit.

Parameters and assumptions

The table below records the baseline values stored in the TIP–TetR binding SBML. These values define the reference implementation; their presence in the model does not imply experimental measurement in the ICHNOS construct.

Parameter Description Baseline Unit Evidence status
b TIP–TetR association-rate constant 4 nM−1 h−1 Literature-informed kinetic assumption adopted from TetR–inducer modelling; not measured for TIP8
Kd,TIP–TetR Dissociation constant of the effective binding reaction 0.25 nM Unmeasured reference affinity, investigated through dedicated sweeps2
uw TIP–TetR dissociation-rate constant 1 h−1 Derived by the assignment rule uw = b × Kd,TIP–TetR
aTetR TetR production rate at maximal promoter activity 50 nM h−1 Literature-informed starting value; requires construct-specific calibration8
KR Effective promoter-repression threshold 0.44 nM Adopted from the Nevozhay et al. (2009) regulatory description8
n Effective repression Hill coefficient 4 – Adopted regulatory-model value; not a direct measurement of binding stoichiometry8
Pmin Residual promoter activity under strong repression 0.0056 – Estimated from promoter-leakage parameters reported by Nevozhay et al. (2009); not measured for the ICHNOS construct8
kdeg,TetR Free-TetR loss coefficient before the explicit dilution term 0.12 h−1 Stored baseline value; source attribution requires reconciliation with the earlier submodel report8
δw Complex-loss coefficient before the explicit dilution term 0.12 h−1 Stored baseline value; not independently measured for the complex
μ Growth-associated dilution rate 0.35 h−1 Assumed growth condition; requires experimental growth-rate assessment
Binding and regulatory assumptions

Effective binding stoichiometry. TIP and active TetR interact through a lumped 1:1 reaction. This describes sequestration at the model level without explicitly resolving TetR oligomerisation or all possible binding states. The experimental structure provides the structural context for this simplification (Luckner et al., 2007)2.

Inactive complex. Only free TetR contributes to promoter repression. The TIP–TetR complex is excluded from the Hill repression function. This assumption is motivated by the peptide-induced allosteric mechanism described by Luckner et al. (2007)2, while complete exclusion of the bound pool is an idealisation of the model.

Effective promoter activity. Promoter regulation is represented algebraically through P(t), rather than through explicit DNA-bound species. Identical regulatory functions are assumed for the promoter copies controlling TetR and reporter production, following the architecture studied by Nevozhay et al. (2009)8.

Residual expression. Pmin represents non-zero promoter activity under strong repression. It is distinct from basal TIP production, which belongs to the sensing module. Its reference value is a derived starting estimate and requires construct-specific validation.

Loss processes and module boundaries

The reported SBML configuration adds an explicit growth-dilution term, μ, to the loss coefficients of free TetR and the TIP–TetR complex. At the stored reference values, both total first-order loss coefficients are:

0.12 + 0.35 = 0.47 h−1

These values describe the implemented configuration. However, the 0.12 h−1 parameter in Nevozhay et al. (2009) represents dilution due to cell growth. It therefore does not independently support its use as an intrinsic degradation coefficient in addition to a separate growth-dilution term.

Complex turnover is also treated as an assumption rather than a measured quantity. This parameterisation remains subject to reconciliation before the final model configuration is fixed.

Production and removal of free TIP are supplied by the selected sensing module during integration. The corresponding parameters are documented with that module.

Parameter Description Baseline Unit Evidence status
kdeg,TetR Free-TetR loss coefficient added to the explicit growth-dilution term 0.12 h−1 Implemented reference value. Its interpretation as intrinsic degradation is not supported by the cited source, which describes 0.12 h−1 as growth dilution.
δw Complex-loss coefficient added to the explicit growth-dilution term 0.12 h−1 Assumed reference value; no independent measurement of TIP–TetR complex turnover is established.
μ Explicit growth-dilution rate 0.35 h−1 Assumed reference growth condition; requires assessment for the experimental chassis and culture conditions.
Baseline values and analysis-specific changes

The binding SBML stores zero initial concentrations for free TetR, free TIP and complex. These source initial conditions are distinct from the states obtained after pre-equilibration in analyses that use an unstressed baseline.

Affinity sweeps and other parameter overrides are documented with their respective analyses. When Kd_TIP_TetR changes at fixed b, the assignment rule updates uw automatically. The baseline affinity is not substituted by a structural prediction unless that change is explicitly specified.

The module was implemented in MATLAB SimBiology and exported to SBML. It contains reversible TIP–TetR binding, TetR production, and loss reactions for free TetR and the complex. Assignment rules determine promoter activity and link the dissociation rate to the binding-affinity parameter.

During PULSE integration, sensing-derived TIP production and removal act on the module’s existing free-TIP pool. The reporter is connected to the same promoter-activity term that regulates TetR production. The assembly procedure, simulation protocols and computational verification are presented in Chapter 3.

Implementation and reproducibility
SBML implementation

The module was developed in MATLAB SimBiology and exported SBML.

It contains three dynamic species: TetR_active, TIP and TetR_TIP_complex. Four reactions represent reversible binding, TetR production, free-TetR loss and complex loss.

Two assignment rules calculate promoter activity, P, and the dissociation rate, u_w = b × Kd_TIP_TetR. Their evaluated values are therefore determined by these rules rather than independently fixed by the values stored in the parameter list.

Initial conditions and module boundaries

All three species have initial concentrations of 0 nM in the source SBML. These source initial conditions are distinct from any pre-equilibrated state used in subsequent analyses.

The binding module contains no independent production or removal reaction for free TIP. Those processes are supplied by the selected sensing module during integration.

Connection to PULSE

The integration workflow uses the binding module as the destination model. Sensing-derived TIP production and removal are connected to its existing free-TIP species, while the tandem reporter receives the same promoter-activity variable that regulates TetR production.

The complete assembly procedure, simulation protocols and computational verification are presented in Chapter 3. Analysis-specific parameter changes and initialisation procedures are documented with the corresponding analyses.

Source-file identification

The source SBML is available in the project repository. The reproducibility record identifies the exact file revision used for integration, allowing its equations, parameter values and initial conditions to be traced to the reported model configuration.

2.2 Oxidative stress sensing

In a nutshell

Input
Hydrogen peroxide exposure.
Output
Time-dependent TIP production feeding the TIP–TetR module.
Key assumption
Yap1 activation and feedback-mediated inactivation can be represented by two effective dynamic states.

Connecting oxidative stress to TIP production

The oxidative sensing module links the yeast stress response to the shared ICHNOS regulatory circuit. We use Yap1-responsive promoter activity to drive TIP production, allowing oxidative stress to influence downstream reporter expression.

We represented the sensor using an adaptive feedback architecture motivated by the Yap1–Trx2 pathway19. Yap1 activation promotes expression of stress-response genes, including TRX210, while thioredoxin-mediated reduction1 (Delaunay fig. 2D) contributes to Yap1 inactivation. This feedback provides a biological basis for a response that rises after stress onset and subsequently subsides11.

Examining the protein–DNA interface

Docking a Yap1 bZIP dimer onto the pSynOS4 promoter gives a geometric picture of how the sensor may sit on its DNA target, measured here with distance thresholds of 3.5 and 5.0 Å. Distance-based contacts alone do not establish binding affinity or experimental promoter activity, and were not used to determine the kinetic parameters of the adaptive model.

Structural modelling protocol

We examined a predicted complex of two Yap1 bZIP chains and a 21 bp double-stranded fragment of the pSynOS4 promoter that carries one TTAGTAA motif (cluster7_1, 2,727 atoms; chains A and B are protein, chain C & D hold the DNA strands). The basic region of the protein was given to HADDOCK as the expected contact surface. In PyMOL we verified the chain identities and listed the residues whose alpha carbons lie within 3.5 Å and 5.0 Å of the DNA. Thr-3, Lys-4, Arg-7, Thr-8, Gln-10, Asn-11 and Lys-22 appear in both chains at 5.0 Å, a pattern consistent with a bZIP homodimer. Because only alpha carbons were counted and the basic region was part of the docking input, these distances describe the geometry of the model. They do not show which residues make specific contacts, and they do not establish binding affinity or promoter activity. They were not used to set any kinetic parameter of the adaptive model.

Two Yap1 bZIP chains, shown in blue and light orange, wrapped around a 21 bp pSynOS4 DNA fragment shown in orange, with sticks marking the protein atoms within 5 Å of the DNA.
Figure 2.3. Predicted complex of two Yap1 bZIP chains (blue and light orange) with a 21 bp pSynOS4 DNA fragment (orange). Sticks mark protein atoms within 5 Å of the DNA. Computational prediction rendered in PyMOL.

Representing sensor activation and adaptation

The dynamic model contains an activation state, Aox, and a feedback mediator, Xox. The activation state represents effective sensor activity, while the mediator accumulates in response to activation and promotes its subsequent suppression.

Stress-dependent activation is described by a Hill function acting on the available inactive fraction. Feedback-mediated inactivation depends on both activation and mediator levels. TIP production combines basal expression with an activity-dependent contribution; TIP loss is represented through degradation and dilution.

The feedback mediator is a lumped variable rather than an explicit measurement of intracellular Trx2 concentration. Likewise, the activation state does not separately resolve Yap1 oxidation, nuclear localisation and DNA binding. These distinctions guide how experimental observations are interpreted during parameterisation.

Full mathematical formulation

dAoxdt = kon,ox H(Sox) (1 − Aox) − koff,ox Aox Xox

Sources: Delaunay 2000 (Fig. 2B); Kuge et al. 1998 (Crm1 nuclear export); Kuge & Jones 1994 (Fig. 1: YAP1 mRNA unchanged, cycloheximide); Delaunay 2000 (Fig. 2B, lower panel); Delaunay 2000 (Fig. 7D) for reduction by TRX2.

dXoxdt = kx,ox Aox − dx,ox Xox

Source: Kuge & Jones 1994 (AP-1 sites −217/−181).

H(Sox) = (Sox/Kact,ox)nox 1 + (Sox/Kact,ox)nox

TIP production is driven by Aox rather than by the static Hill term:

d[TIP]dt = βbasal,ox + (βmax,ox − βbasal,ox) Aox − (kdeg,TIP + μ) [TIP]

The (1 − Aox) term encodes a conserved Yap1 pool (no de novo synthesis under stress). Aox is dimensionless on [0, 1]; Sox is a constant parameter per simulation. In SBML, Aox and Xox are parameters with Constant = false governed by rate rules, not species (dimensionless is not a valid species unit in SimBiology).

Three stacked panels over six hours at 400 micromolar: active Yap1 fraction, the Trx2 feedback mediator, and TIP concentration, each comparing constant input with two declining-input scenarios. Under constant input the Yap1 peak is followed by a sustained plateau and TIP stays high; under declining input all three decay back to baseline.
Figure 2.4. Internal sensor dynamics at 400 µM H2O2: active Yap1 (Aox), the thioredoxin feedback mediator (Xox) and TIP production (TIPox), under constant vs declining effective input. A transient Aox peak does not produce a matching TIP pulse under sustained input.

Parameterisation and computational implementation

We drew on published observations at different levels of the oxidative response12, including Yap1 redox dynamics, TRX2 transcript measurements and promoter-driven fluorescence. Each dataset was assigned a specific role: upstream measurements informed the sensing description, while downstream expression measurements informed or assessed the mapping to reporter production.

Because these measurements report different biological quantities, they were not treated as interchangeable readouts of sensor activity. Parameters unsupported by direct measurements were retained as assumptions or uncertain inputs. The canonical constant-input formulation reproduces the rise in Yap1 oxidation but not the sustained plateau observed around 30 minutes. That gap motivated the input-dynamics analysis presented in the physics-informed modelling section; parameter identifiability is examined there and in the Fisher information analysis, where dx,ox is shown to be structurally non-identifiable from the available data.

Parameter sources and calibration
Parameter Description Baseline Unit Evidence status
Kact,ox H2O2 concentration giving half-maximal Yap1 activation (midpoint of the dose–response) 208 µM Calibrated from Delaunay 2000 Fig. 2C densitometry at 5 min; method range 198–219
nox Hill coefficient: steepness / cooperativity of the activation curve (dimensionless exponent) 2.75 – Calibrated from the same Fig. 2C fit; method range 2.54–2.97
koff,ox Feedback inactivation rate: how strongly the Trx2 mediator switches active Yap1 off; sets the plateau level 160 h−1 Calibrated on a coarse grid against the t50 of Delaunay Fig. 2B
dx,ox Removal rate of the feedback mediator Xox; sets the timescale over which feedback builds up 0.5 h−1 Calibrated on the same coarse grid against Fig. 2B
kon,ox Rate at which Yap1 becomes active (oxidation + nuclear retention); in practice dominated by nuclear accumulation 50 h−1 Fixed by convention; non-identifiable with koff,ox at steady state
kx,ox Production rate of the feedback mediator Xox per unit active Yap1 1 h−1 Fixed by construction; defines the unit of Xox
βmax,ox Maximal TIP production rate at full Yap1 activation 118 nM h−1 Literature prior; 23.6× ratio from Dacquay 2021 Fig. 3A (alt1)
βbasal,ox Basal TIP production rate with no stress 5 nM h−1 Fixed by construction; absolute scale non-identifiable, absorbed by Kd,TIP–TetR
kdeg,TIP TIP degradation rate; growth dilution added separately through μ 1.0 h−1 Fit later; shown not to determine the time shape
μ Growth-associated dilution rate 0.35 h−1 Measured from the team growth curve; physiological floor for dx,ox, though the identifiability sweeps span a wider range of densitometry-compatible values
Sigmoidal dose-response of oxidised sensor fraction at five minutes against hydrogen peroxide concentration on a logarithmic axis, with the three input scenarios overlapping and the Delaunay densitometry points falling on the curves.
Figure 2.5. Sensor dose–response at 5 min against Delaunay (2000) Fig. 2C (Kact,ox = 208 µM, nox = 2.75). Each curve is scaled by a single free factor; markers are the densitometry points. The three input scenarios overlap at this short readout.

The adaptive module was implemented in MATLAB SimBiology and exported to SBML for integration. Its time-dependent TIP production supplies the input to the TIP–TetR regulatory module, connecting oxidative sensing to the common tandem reporter.

Implementation and reproducibility

The adaptive module was built in MATLAB SimBiology and exported to SBML. Aox and Xox are dimensionless parameters with rate rules; the single edited reaction replaces the static Hill term with Aox in TIP production. Standalone checks passed: zero stress gives TIP = basal (5/1.35 ≈ 3.70 nM with separate μ, or 5 nM when μ is folded into kdeg,TIP); at 400 µM, Apeak ≈ 0.863 at ~4 min and Aplateau ≈ 0.305. A manifest check (manifest_check.py) verifies the SBML path, SHA256 and the 11 parameters before integration.

Active Yap1 fraction over the first hour at 400 micromolar hydrogen peroxide: a sharp rise to a peak near four minutes followed by decay, with the constant-input curve decaying slowest and the two declining-input curves faster, plotted against the Delaunay window and unmix densitometry points.
Figure 2.6. Simulated Yap1 activation Aox(t) at 400 µM H2O2 compared with the Delaunay (2000) Fig. 2B oxidation time course (window and unmix densitometry). The canonical constant-input model (solid) captures the rise but not the ~30-min plateau; declining-input scenarios decay faster.

2.3 ER stress sensing

In a nutshell

Input
ER stress, represented by DTT exposure in the calibration data.
Output
Time-dependent TIP production feeding the TIP–TetR module.
Key assumption
HAC1 splicing and downstream Hac1 activity are represented by a single effective activation state.

Connecting ER stress to TIP production

The ER sensing module connects the unfolded protein response to the shared ICHNOS regulatory circuit. Activation of Ire1 promotes HAC1 mRNA splicing, enabling production of the Hac1 transcription factor. Hac1-responsive promoter activity then drives TIP production.

We represented adaptation through a feedback architecture motivated by the Ire1–Hac1–Kar2 pathway. Hac1 promotes expression of KAR2, encoding the chaperone BiP/Kar2, which contributes to regulation of Ire1 activity. This architecture allows sensor activation and subsequent suppression to be represented within the same dynamic model.

Examining the protein–DNA interface

We developed a structural workflow to examine the interaction between the Hac1 bZIP domain and the UPRE-1 DNA element. A two-chain Hac1 bZIP model was generated using ColabFold, and double-stranded DNA containing the recognition sequence was constructed separately.

The structures were prepared in PyMOL, with distinct chain identifiers and non-overlapping residue numbering, before submission to HADDOCK. Selected protein regions and the DNA recognition core were used to define docking restraints.

This analysis examines candidate binding geometries. It does not directly determine promoter activity or the kinetic parameters used in the adaptive sensing model.

Structural modelling protocol

We examined a predicted complex of two Hac1 bZIP chains bound to the double-stranded UPRE-1 element of the KAR2 promoter (22 bp, GGAACTGGACAGCGTGTCGAAA), built with ColabFold v1.6.1 and docked in HADDOCK v2.4 under restraints on the basic region of each monomer and on the CAGCGTG core. Of the eleven clusters returned we report the best-scoring one (cluster11_1, HADDOCK score −71.9 ± 7.5, Z-score −1.45). In PyMOL we mapped the interface using any protein atom within 3.5 Å (hydrogen-bond and salt-bridge range) and 5.0 Å (including van der Waals contacts) of the DNA, giving fifteen and eighteen residues; both monomers sit in chain A, so residues are numbered from the start of each. Arg-4, Ile-8, Arg-12 and Arg-19 contact DNA from both monomers, the arginine-rich recognition expected of a bZIP homodimer, while the remaining contacts differ between them, so recognition here is only partly symmetric. Two limits follow: contact with the CAGCGTG core is a consequence of the restraints rather than independent evidence of specificity, and the complex contains Hac1 and DNA only, whereas Hac1 bound to UPRE-1 without Gcn4 forms a complex that is not competent to upregulate transcription13.

These distances describe interface geometry, not binding affinity or promoter activity, and none was used to set a parameter value. Their role is structural: the ER activation term is fitted to HAC1 splicing data, so the model assumes the downstream step, spliced Hac1 activating pKAR2, is fast rather than fitting it, and this complex tests whether that assumed step is structurally possible.

Two Hac1 bZIP chains bound to a 22 bp double-stranded UPRE-1 element from the KAR2 promoter, with the basic region of each monomer lying along the DNA.
Figure 2.7. Best-scoring HADDOCK cluster for the Hac1 bZIP homodimer on the UPRE-1 element of the KAR2 promoter (cluster11_1, HADDOCK score −71.9 ± 7.5, Z-score −1.45). Three further clusters score within one standard deviation, so this is a plausible binding geometry rather than a unique pose. Arg-4, Ile-8, Arg-12 and Arg-19 contact the DNA from both monomers; the remaining contacts differ between them. Computational prediction rendered in PyMOL.

Representing sensor activation and adaptation

The dynamic model contains an activation state, Aer, and a feedback mediator, Xer. Stress-dependent activation follows a Hill function and is limited by the remaining inactive fraction. The mediator accumulates in response to activation and contributes to sensor suppression.

The activation state is linked to the fraction of spliced HAC1 mRNA and serves as a proxy for downstream Hac1 activity. This approximation omits an explicit translation step. The feedback mediator represents an effective regulatory influence rather than an absolute BiP/Kar2 concentration.

TIP production combines basal expression with an activation-dependent contribution. Degradation and growth-associated dilution are treated as separate loss processes, using a common TIP-loss convention across the oxidative and ER modules.

Full mathematical formulation

Sensor activation and feedback are two dimensionless states governed by rate rules:

dAerdt = kon,er H(Ser) (1 − Aer) − koff,er Aer Xer

dXerdt = kx,er Aer − dx,er Xer

H(Ser) = Serner Kact,erner + Serner

TIP production follows the activation state rather than the static Hill term, with degradation and growth dilution as separate loss processes:

d[TIPer]dt = βbasal,er + (βmax,er − βbasal,er) Aer − (kdeg,TIP + μ) [TIPer]

A separate two-state reporter is included in the sensing module for calibration against fluorescence data only. It is excluded from the merged PULSE model, where the tandem timer of Section 2.4 takes its place:

dRimmdt = βbasal,er + (βmax,er − βbasal,er) Aer − kmat,er Rimm − μ Rimm

dRmatdt = kmat,er Rimm − μ Rmat

The (1 − Aer) term encodes a conserved sensor pool. Aer is dimensionless on [0, 1]; Ser is a constant parameter per simulation. Aer and Xer are governed by rate rules in both modules, but the exports differ: in the oxidative file they are SBML parameters with constant="false", and in the ER file they are species with substanceUnits="dimensionless".

One consequence of the baseline parameter set is worth stating. With dx,er = 0 the mediator has no removal term, so Xer is the running integral of Aer and the only steady state is Aer = 0. The approach is not exponential: quasi-steady Aer ≈ kon,erH(Ser) / (koff,erXer) gives Xer ∝ √t and therefore Aer ∝ t−1/2. Simulation confirms this at Ser = 2200 µM, where Aer falls 0.0768 → 0.0543 → 0.0168 at 24, 48 and 500 h. Adaptation is therefore fast and then extremely slow: the half-time from the peak is 69 min, but Aer is still above 1% of its peak after 2000 h. The oxidative branch, with dx,ox = 0.5 h−1, instead settles to a plateau near 0.305.

Parameterisation and computational implementation

We used published HAC1 splicing time courses to investigate the sensor dynamics. Data from Pincus et al.14 were digitised using WebPlotDigitizer and used to assess the model across two DTT exposure conditions.

Splicing measurements and fluorescence measurements were treated as distinct observables. To examine how maturation and accumulation transform sensor activity into fluorescence, we included an auxiliary reporter description. This calibration readout is separate from the downstream tandem timer used in the integrated ICHNOS circuit.

Parameter assignments distinguish fitted quantities, fixed normalisation choices and assumed values. Further examination of stress-input dynamics, alternative formulations and parameter identifiability is presented in the physics-informed modelling section.

Parameter sources and calibration
Parameter Description Baseline Unit Evidence status
Kact,er DTT concentration giving half-maximal sensor activation 2345.3 µM Fitted to four peak HAC1-splicing dose points (1500, 2200, 3300, 5000 µM), Pincus et al. 2010. Responses at 1500 and 5000 µM were estimated from the paper text, not digitised
ner Hill coefficient of the activation response 3.97 – Same four-point fit, reported resnorm 0.0103. Two of the four response values were estimated from the paper text rather than digitised; uniqueness and uncertainty are not established
kon,er Rate at which the sensor becomes active 7.2 h−1 Carried over from the source model. Fitting to the Pincus 2010 splicing time course is recorded as pending; this value is not documented as a completed fit
koff,er Feedback inactivation rate 11.09 h−1 Carried over from the source model; not fitted. Structurally non-identifiable with kx,er and dx,er
kx,er Production rate of the feedback mediator Xer 1 h−1 Fixed by construction; defines the unit of Xer. Structurally non-identifiable with koff,er and dx,er, so only their combination is determined
dx,er Removal rate of the feedback mediator 0 h−1 Carried over; not fitted. Zero removes the explicit decay term and sits below the dilution-rate floor argued for the oxidative branch, which is why the resulting adaptation has no non-zero steady state (see formulation). Varied from 0 to 0.5 h−1 in the sensitivity analysis
βmax,er Maximal TIP production at full activation 25 nM h−1 Carried over from the source model; derivation not recorded
βbasal,er Basal TIP production with no stress 0.77 nM h−1 Carried over; derivation not recorded. Ratio βmax/βbasal = 32.5×
kdeg,TIP TIP degradation; dilution added separately 1.0 h−1 Shared with the oxidative module; cross-variant equality is checked
μ Growth-associated dilution 0.35 h−1 Measured from the team growth curve; shared across modules
kmat,er Maturation rate of the calibration reporter 0.8849 h−1 Literature-derived from the reported mCherry maturation half-time of 47 min, Khmelinskii et al. 2012: ln2/(47/60 h)
Ser Stress input held constant per simulation 100 µM Input parameter, not a calibration. At this value the Hill term gives under 0.001% activation, so the shipped default is a near-baseline run

Four of these carry a recorded source; the remainder are carried over from the source model without one. Section 7.1 reports a second, coherently fitted ER set obtained under a declining-input formulation, with Kact = 929.5 µM and n fixed at 4. The two sets are alternatives, not refinements of one another, and the identifiability discussion there applies to both.

The adaptive module was implemented in MATLAB SimBiology and exported to SBML. During PULSE integration, its time-dependent TIP production is connected to the TIP–TetR module, allowing the ER sensing branch to use the same regulatory and tandem reporter core as the oxidative branch.

Implementation and reproducibility

The adaptive ER module was built in MATLAB SimBiology and exported to SBML. TIP production and loss are two reactions. The module declares twelve parameters, verified against the manifest together with the file path and SHA256 before integration.

The calibration reporter states Rimm and Rmat are fitting-only and are excluded from the merge, so the integrated PULSE model carries exactly one reporter description, the tandem timer.

Recorded verification outcomes for the ER branch: the reference simulation completes over the specified horizon; kdeg,TIP matches the oxidative variant at 1.0 h−1; maximum sensor-state magnitude at zero stress is 0; and the sensing-bypass check passes at 0, 2, 5, 10, 20 and 50 nM.

Zero stress gives TIP at its basal level, βbasal,er/(kdeg,TIP + μ) = 0.77/1.35 ≈ 0.57 nM. At Ser = 2200 µM the activation state peaks at Aer ≈ 0.609 at 26 min, against Apeak ≈ 0.863 at ~4 min in the oxidative module of Section 2.2.

2.4 Tandem fluorescent timer

In a nutshell

Input
Time-dependent promoter activity, P(t), supplied by the TIP–TetR module.
Output
Predicted green and red reporter signals and their red-to-green ratio.
Key assumption
The fused fluorophores share a production rate but mature through separate kinetic pathways.

Connecting reporter expression to temporal information

The tandem fluorescent timer converts regulated reporter production into two signals with different maturation dynamics. We modelled an sfGFP–mCherry fusion, using the kinetic description reported by Khmelinskii et al.15. The faster green component responds earlier to reporter production, while the slower red component becomes fluorescent through two maturation steps.

Their different kinetics generate a changing red-to-green ratio. We use this behaviour to investigate the temporal information retained by the reporter. Interpreting that ratio requires accounting for the history of reporter production and loss; its suitability for joint dose–time estimation is assessed in the decoding analysis.

Representing fluorophore maturation and loss

The model tracks five molecular pools. The green pathway contains an immature and a mature state. The red pathway contains an immature state, an intermediate and a fully mature state. These are parallel descriptions of the two components of the fusion, rather than a sequential conversion from green to red fluorescence.

Both pathways receive the same production input, proportional to aReporterP(t). Maturation is represented by first-order transitions. Each pool also undergoes loss through reporter degradation and growth-associated dilution, which are treated separately.

Full mathematical formulation
Left: green and red maturation curves at P = 0.5, with the FRET-corrected observed green shown as a dashed line below the true green. Right: the red-to-green ratio with and without the FRET correction, the corrected ratio settling higher.
Figure 2.4. Tandem timer maturation and FRET-corrected red-to-green ratio at P = 0.5, simulated from reporter_module_v2.sbml.

The reporter tracks five molecular pools: an immature and a mature green state, and an immature, intermediate and mature red state. Both channels are produced at the same rate from promoter activity P(t); maturation and loss are first-order.

d[Gdark]dt = aRepP − (m + kdeg + μ) [Gdark]

d[G]dt = m [Gdark] − (kdeg + μ) [G]

d[Rdark]dt = aRepP − (m1 + kdeg + μ) [Rdark]

d[Rint]dt = m1 [Rdark] − (m2 + kdeg + μ) [Rint]

d[R]dt = m2 [Rint] − (kdeg + μ) [R]

The green channel matures in one step (rate m); the red channel in two (m1 then m2), which is what gives the slower red signal and the time-dependent red-to-green ratio. Every pool is lost through kdeg,Reporter + μ. These are parallel descriptions of the two fluorophores of the fusion, not a sequential green-to-red conversion.

Relating molecular pools to observed fluorescence

We included a FRET observation layer to account for reduced sfGFP emission as mCherry matures within the fusion. The model calculates the mature fraction of the red pool and uses it, together with a FRET-efficiency parameter, to adjust the predicted green signal.

The red-to-green ratio is then calculated using the adjusted green signal. An instrument-scaling factor relates this ratio to the measurement convention used during calibration. A small numerical regularisation term prevents division by zero when reporter pools are initially absent.

This observation layer changes how fluorescence is calculated without altering the underlying maturation reactions.

Fluorescence observation equations

A FRET observation layer accounts for reduced sfGFP emission as neighbouring mCherry matures within the same fusion. It is computed by five repeated assignments:

Rtotal = [Rdark] + [Rint] + [R]

bFRET = [R] Rtotal + ε

Gobs = [G] (1 − bFRET E)

ΓFRET = [R] Gobs + ε

Γmeas = f ΓFRET

Here bFRET is the mature fraction of the red pool, E the FRET efficiency, f an instrument-scaling factor and ε a small regularisation term that prevents division by zero when pools are initially empty. The same sfGFP/mCherry pair is used, so the reported E = 0.173 transfers as a prior rather than an analogy, but the linker and expression context differ and the value still requires confirmation in the constructed fusion. The ratio must be read from Measured_Ratio_RG (with FRET), not from raw red/green: the correction raises the steady-state ratio by about 14% at the baseline dilution rate, and the size of the correction falls as μ rises.

Parameterisation and computational checks

Maturation rates and the initial FRET-efficiency value were taken from the published sfGFP–mCherry timer description. The FRET value is treated as a literature-informed input whose applicability to the constructed fusion requires confirmation. Reporter production, degradation, growth dilution and instrument scaling were assigned provisional values pending experimental calibration.

Parameters and assumptions
Parameter Description Baseline Unit Evidence status
P Promoter activity / occupancy input from the TIP–TetR module 0.5 – Interface variable; placeholder 0.5 until merge, then P(t)
aReporter Shared production rate of both channels 50 nM h−1 Fit later; same estimate as aTetR
m Green (sfGFP) maturation rate 7.39 h−1 Literature prior, Khmelinskii 2012 (half-time 5.63 min)
m1 Red (mCherry) maturation rate, step 1 2.46 h−1 Literature prior, Khmelinskii 2012 (16.91 min)
m2 Red maturation rate, step 2 1.37 h−1 Literature prior, Khmelinskii 2012 (30.30 min)
kdeg,Reporter Reporter degradation rate 0.01 (≈0) h−1 Design target: non-degradable reporter; dilution carried by μ
μ Growth-associated dilution rate 0.35 h−1 Measured (growth curve); shared across modules
E FRET efficiency (sfGFP quenched by mature mCherry) 0.173 – Literature prior, Khmelinskii 2012; same fluorophore pair
f Instrument-scaling factor 1 – Placeholder; becomes a fitted parameter at calibration (Exp. 2)
ε Numerical regularisation (avoids 0/0 at t = 0) 1×10−9 nM Technical, not biological

Key assumptions: the fused fluorophores share one production rate but mature through separate pathways; the reporter is treated as effectively non-degradable, with growth dilution the dominant loss; FRET efficiency is taken directly from the reference pair.

The module was implemented in MATLAB SimBiology and exported to SBML. Standalone checks examined the absence of reporter production at zero promoter activity, maturation under constant input and the effect of including or removing the FRET observation layer. SimBiology and Tellurium simulations were compared to assess consistency across implementations.

Implementation and reproducibility

The module was built in MATLAB SimBiology and exported to SBML (reporter_module_v2). The FRET layer is implemented as five repeated assignments; all five quantities are declared with Constant = false and explicit units (nM or dimensionless) to avoid dimensional-analysis errors. Standalone checks passed: at P = 0 all five states stay 0; at P = 0.5 SimBiology and Tellurium agree to <1%; the ratio without FRET matches the closed-form value; with FRET it rises as expected.

Note: the SBML export prefixes species IDs with the compartment name (cell_), handled by name-matching in the merge script. During integration the placeholder P is replaced by the TIP–TetR module's rule-governed P(t).

During PULSE integration, the standalone promoter-activity placeholder is replaced by the dynamic P(t) calculated by the TIP–TetR module. The reporter therefore receives the same regulatory activity that controls TetR production, completing the connection from stress sensing to the two fluorescence observables.

3. Building and integrating the PULSE model

In a nutshell

Input
A stress condition applied to the oxidative or ER sensing variant.
Output
Integrated trajectories of sensor activity, TIP–TetR regulation and tandem reporter fluorescence.
Architecture
One adaptive sensing module connected to a shared regulatory and reporter core.

Assembling a connected dynamic system

We integrated the individual SBML modules to represent the complete pathway from stress sensing to fluorescence. The oxidative and ER variants are assembled separately, each combining its adaptive sensor with the shared TIP–TetR regulatory module and tandem fluorescent reporter.

Two interfaces connect the modules. Sensor-dependent TIP production supplies the free TIP pool that participates in TetR binding. Free TetR determines promoter activity, P(t), which controls both TetR and reporter production, linking the regulatory feedback loop to the fluorescent readout.

Module mapping and SBML assembly

The Python integration workflow uses libSBML to build each variant from its source files. The TIP–TetR module forms the destination model, into which the sensing and reporter components are incorporated.

The TIP interface and shared parameters are resolved by name, and the corresponding SBML references are remapped during assembly. The sensing and regulatory modules describe the same TIP molecule under different names. Mapping these references to a single free TIP pool ensures that sensor-driven production supplies the molecule participating in TetR binding.

The reporter’s promoter-activity input is similarly mapped to the existing rule-governed promoter activity, P(t), preserving the shared regulation of TetR and reporter production.

Integration carries over reactions and mathematical rules, including the rate rules governing sensor activation and feedback. This is essential because copying a variable without its governing rule would not preserve its intended dynamics.

The workflow accommodates both SBML representations used by the sensors: dynamic parameters in the oxidative module and dynamic species in the ER module.

The auxiliary ER reporter states, Rimm and Rmat, are excluded together with their governing rules. These states support standalone calibration; the integrated circuit uses the tandem fluorescent timer as its reporter.

Maintaining a consistent integrated model

Integration connects shared quantities while retaining the distinct processes represented by each module. Both assembled variants use a common cellular compartment and growth-dilution parameter, while the regulatory module supplies the promoter activity used for TetR and reporter production.

Inspection of the exported models confirmed the intended species initialisation and retention of the sensor rate rules. Both integrated variants were successfully loaded and simulated under the reference configuration. Computational checks and their outcomes are presented in the verification section below.

Units, shared parameters and initialisation
Compartments and unit references

The assembly workflow resolves compartment references by identifier or name and maps unit identifiers when components are transferred between modules. Both exported variants contain a single compartment named cell, with a stored volume of 1 L. This is the model’s compartment-volume convention rather than a measured single-cell volume.

Unit definitions are copied or reused during assembly, and identifier mappings are applied within reaction and rule expressions.

Shared and process-specific parameters

The parameters P and μ are explicitly designated as shared quantities. Reporter production references the regulatory module’s rule-governed promoter activity, P(t), rather than retaining the reporter module’s standalone constant input.

Both integrated variants use μ = 0.35 h−1. When fixed shared parameter values differ between source modules, the workflow retains the destination model’s value and reports the discrepancy.

Parameters outside the shared set remain separate when their names coincide. This preserves distinctions such as the sensing Hill coefficient and the promoter-repression Hill coefficient.

The cross-variant check confirmed kdeg,TIP = 1.0 h−1 in both assembled models. Inspection of the source reactions additionally confirmed that both sensing branches represent free-TIP removal through kdeg,TIP + μ.

Initialisation

For copied species, initial amounts and concentrations are retained in the form specified by their source definitions. In both exported variants, free TIP, active TetR, the TIP–TetR complex and the five reporter states have initial concentrations of zero.

The ER activation and feedback states retain their dimensionless species representation, with initial amounts of zero. The oxidative sensor retains its rate-rule-governed parameter representation.

The oxidative sensing module’s initial assignment for TIP is excluded during assembly. The unified free-TIP pool therefore retains the destination regulatory model’s initial condition rather than receiving the isolated oxidative sensor’s basal-state assignment. Neither exported variant contains initial assignments.

These source initial conditions describe the model configuration used here; any pre-equilibration used in subsequent analyses is specified with the corresponding simulation protocol.

Following the pulse through the circuit

We simulated the assembled variants using Tellurium/RoadRunner, following sensor activation and feedback, free TIP, active TetR, the TIP–TetR complex and the tandem reporter states. Tracking these quantities connects the internal regulatory response to the reporter output while retaining information that would be lost from final values alone.

Both reference simulations completed over 200 h. The oxidative sensor showed a rapid activation peak followed by a lower sustained activity. At 400 μM oxidative input, a densely sampled run resolved an activation peak of approximately 0.863 at 4.1 min, compared with an activity of approximately 0.305 at 200 h. The downstream free-TIP concentration remained elevated, reaching 19.104 nM at 200 h. Thus, the transient sensor activation did not imply a return of free TIP to zero under sustained input.

For the ER reference input of 100 μM, the sampled activation maximum occurred much later, at approximately 22.85 h, while free TIP reached 0.2608 nM at 200 h. These examples illustrate the temporal behaviour of the two reference configurations; their different input levels do not constitute a matched comparison of sensor performance.

Three stacked panels over the first four hours at 400 micromolar oxidative input: sensor activation and feedback, free TIP with the TetR regulatory states, and the five tandem reporter states. Activation peaks sharply near four minutes and declines, while free TIP overshoots modestly and stays elevated.
Figure 3.1. Early response of the integrated oxidative PULSE model under sustained input. Sensor activation and feedback (top), free TIP and TetR regulatory states (middle), and the five tandem reporter states (bottom) during the first four hours at a constant oxidative input of 400 μM. Sensor activation peaks at approximately 0.863 around four minutes and subsequently declines. Free TIP shows a modest overshoot and remains elevated, demonstrating that the activation transient is not reproduced as an equivalent free-TIP pulse. Reporter curves represent molecular states rather than FRET-corrected fluorescence. The annotated TIP peak-to-final ratio refers to the four-hour endpoint.
Two stacked panels over 200 hours at 100 micromolar ER input: free TIP, active TetR and the TIP–TetR complex above, and the five tandem reporter states below. Free TIP remains elevated across the whole window.
Figure 3.2. Integrated ER circuit response under sustained input. Free TIP, active TetR and the TIP–TetR complex (top), and the five tandem reporter states (bottom), over 200 h at a constant ER input of 100 μM. Simulations start from the model’s reset state without pre-equilibration. Free TIP remains elevated, with a sampled peak-to-endpoint ratio of approximately 1.011. Reporter curves represent molecular-state concentrations rather than FRET-corrected fluorescence. Sensor activation and feedback states are not shown.
Simulation protocols and output sampling
Reference simulations

The entry-point script, run_ichnos.py, assembles each variant from its source SBML files and loads the integrated model through Tellurium/RoadRunner. Output identifiers are relabelled with biological names.

The reference runs used constant inputs of Sox = 400 μM and Ser = 100 μM. Each variant was simulated from 0 to 200 h with 500 output points, starting from the model’s reset state without a separate pre-equilibration stage.

Transient summaries

The entry-point workflow reports sampled peak values, peak times and final sampled values for the activation state, feedback state and free TIP. Final sampled values are treated as endpoint measurements rather than independent evidence of equilibrium.

An undersampling warning flags peaks occurring within the first five output intervals when the sampled peak exceeds the endpoint value. This is a screening rule for potentially unresolved early peaks rather than a general test of sampling adequacy.

Resolution of the oxidative transient

The reference output interval was approximately 0.401 h, which was insufficient to resolve the rapid oxidative activation peak. The entry-point estimate of 0.5342 at 0.401 h was therefore excluded from quantitative interpretation of that peak.

The existing plotting workflow was subsequently run over 0–4 h with 2,000 output points at 400 μM oxidative input. Independently, the existing dose-response workflow used 4,000 output points over 0–10 h and reported an activation peak of 0.8627 at approximately 4.1 min for the same dose. The latter values were retained for the quantitative description of the early oxidative response.

The ER plotting run used the reference input of 100 μM over 0–200 h with 2,000 output points. The reported ER activation peak time of approximately 22.85 h comes from the 500-point reference run and is therefore a sampled estimate.

Reporter states and observables

The basic simulations and plotting workflow track the five reporter states, including immature and mature forms. These state concentrations are distinguished from the fluorescence observation variables calculated by assignment rules.

Analyses requiring observed fluorescence or the red-to-green ratio explicitly select the corresponding observation variables. Dose-response sweeps, ratio analyses, pre-equilibration and modified input histories are documented with their respective analyses.

Checking the integrated implementation

We assessed the integrated models through assembly diagnostics, reference simulations and functional checks. Both variants completed the 200 h reference simulations, and the cross-variant check confirmed a common TIP degradation parameter.

The zero-stress and sensing-bypass checks also passed. Repeating the functional checks with denser output sampling preserved their outcomes.

Check Criterion Recorded outcome
Reference simulation Both integrated variants complete the specified 0–200 h simulation Completed for OX and ER
Cross-variant parameter consistency Equal kdeg,TIP values within an absolute tolerance of 10−9 PASS: 1.0 h−1 in both variants
Zero-stress reporter response Basal-to-saturating peak reporter-total ratio below 0.30 PASS: OX 0.189; ER 0.259
Zero-stress sensor states Maximum absolute activation and feedback state values below 10−9 PASS: reported maximum 0 in both variants
Sensing bypass Reporter total at 200 h is non-decreasing across the tested fixed TIP concentrations PASS at 0, 2, 5, 10, 20 and 50 nM

These results support the intended computational behaviour under the tested conditions. They do not constitute experimental validation. Unit-related warnings from a separate libSBML consistency audit are retained in the reproducibility record; complete unit consistency was not established by these checks.

Computational checks and their criteria
Assembly diagnostics

The integration workflow inspects variable parameters without governing rules, missing parameter-unit declarations and shared-parameter values. These diagnostics help identify quantities that could remain unintentionally fixed, lack unit annotations or acquire inconsistent values during assembly.

A separate cross-variant check compares kdeg,TIP between the assembled oxidative and ER models. Both contained a value of 1.0 h−1 and passed the specified absolute tolerance of 10−9.

Zero-stress response

Each integrated variant was simulated under two constant-input conditions: zero stress and a numerical saturation reference set to 1,000 times its activation-threshold parameter. The saturation reference serves as a computational control rather than an experimentally prescribed exposure.

For this check, reporter total is defined as the sum of the five Reporter_* state concentrations, including immature forms. It is distinct from observed fluorescence and from the red-to-green ratio.

The criterion compares the maximum reporter total over the zero-stress trajectory with the maximum over the saturating-input trajectory:

maxt Rtotal, S=0(t) maxt Rtotal, S=Ssat(t) < 0.30

The peak-based comparison avoids treating a late decline in an adapting response as reduced activation capacity. With 20,001 output points over 0–200 h, the ratios were 0.189 for OX and 0.259 for ER; both passed.

The activation and feedback states were additionally inspected under zero stress. Their reported maximum absolute values were zero in both variants, satisfying the 10−9 tolerance. This criterion applies to the sensor states, not to downstream TIP or reporter concentrations, which may remain nonzero because of basal production.

Sensing-bypass response

The bypass configuration combines the TIP–TetR and reporter modules without a sensing module. Free TIP is clamped at each tested concentration: 0, 2, 5, 10, 20 and 50 nM.

Each condition was simulated over 0–200 h. The criterion requires reporter total at 200 h to be non-decreasing across the tested TIP levels, allowing a numerical tolerance.

Reporter total increased from 3.8132 at zero TIP to 151.0751 at 50 nM TIP, while active TetR decreased from 1.4604 to 0.4222 nM. The monotonicity criterion passed.

This test assesses downstream regulation under a maintained free-TIP concentration. It does not represent a finite TIP bolus or test the sensing layer.

Output-sampling check

The default functional checks used 200 output points over 200 h. They were repeated with 20,001 output points over the same interval.

The ER basal-to-saturating peak ratio changed from 0.260 to 0.259, while the OX ratio remained 0.189 at the displayed precision. Bypass endpoint values were unchanged at the displayed precision. All check outcomes were preserved.

Model configuration and scope

The reported checks used the reference oxidative and ER configurations described above. Integrated SBML exports and execution logs were retained internally to associate the reported results with the model configuration used.

The reference simulations and functional checks were performed using Tellurium/RoadRunner. Analysis-specific changes to parameters, inputs, initialisation or model structure are documented in the corresponding sections.

These checks assess computational implementation and expected behaviour under defined conditions. They do not establish experimental validity or complete unit consistency.

4. Assessing chassis transferability

Extending the modular architecture

We investigated whether the ICHNOS architecture could support dose discrimination when connected to a bacterial oxidative stress sensor. We constructed an in silico implementation for Escherichia coli, replacing the yeast sensing layer while retaining the organisation of the TIP–TetR regulatory module and tandem fluorescent reporter.

The central question was whether bacterial sensing could supply TIP within a range compatible with downstream regulation, and whether TetR autoregulation could shape the resulting transient dose response. This analysis evaluates a proposed bacterial implementation; it does not establish experimental transferability.

Connecting bacterial sensing to the downstream circuit

We represented bacterial oxidative sensing through a mechanistic OxyR model incorporating redox regulation, GrxA-mediated reduction and intracellular hydrogen peroxide removal through KatG and AhpC16. TIP was introduced as an additional OxyR-regulated product under pKatG, providing a direct molecular connection to the regulatory module.

The coupled system follows stress-dependent TIP production through TetR binding, autoregulation and reporter maturation. A common growth-dilution rate of 0.72 h−1 was applied throughout16. The interface uses explicit TIP production and binding rather than normalising an upstream output into an unrelated downstream input.

Model equations, parameter sources and transfer assumptions

Bacterial sensing

The upstream formulation was adapted from the OxyR model of Choudhary and colleagues1617. It represents reduced and oxidised OxyR, GrxA, KatG, AhpC and intracellular hydrogen peroxide.

Let Or and Oo denote reduced and oxidised OxyR, and H and Hext denote intracellular and external hydrogen peroxide. OxyR interconversion follows:

vox = Kox Or H,     vred = Kred G Oo Oo + hO

dOrdt = −vox + vred,     dOodt = vox − vred

Here, G denotes GrxA. Total OxyR is conserved by these reactions.

For GrxA and AhpC, production depends on oxidised OxyR through a saturating activation term:

dGdt = RG + KG Oo Oo + hG − μG

dAdt = RA + KA Oo Oo + hA − μA

Here, A denotes AhpC. KatG, denoted by K, follows:

dKdt = RK + KK (Oo/hK)n 1 + (Oo/hK)n − μK

In the source formulation1617 this term is Michaelis–Menten; introducing the exponent n modifies the published model structure rather than selecting a parameter value.

Intracellular peroxide changes through influx, basal production and scavenging:

dHdt = RinfluxHext + RH,basal − kAA H H + hA,H − kKK H H + hK,H

TIP interface and downstream regulation

TIP production uses the same pKatG activation function:

qT(Oo) = RT + KT (Oo/hT)n 1 + (Oo/hT)n

The reference configuration sets KT = KK = 9000 nM h−1, hT = hK = 180 nM and RT = RK = 0.

Assigning identical promoter-response parameters provides a defined interface. It does not account explicitly for differences in translation efficiency, transcript stability or coding sequence.

For free TIP T, active TetR R and complex C:

dTdt = qT − (kdeg,TIP + μ)T − bTR + uwC

dRdt = aTetRP(R) − (kdeg,TetR + μ)R − bTR + uwC

dCdt = bTR − (uw + δw + μ)C

with

uw = bKd,TIP,     P(R) = Pmin + 1 − Pmin 1 + (R/KR)nTetR

The tandem reporter retains the maturation structure described in its module section. Both colour branches receive the production term aReporterP, and all reporter states undergo loss at kdeg,Rep + μ.

Reference parameters and evidence status

The implementation uses hours and nM. Its principal parameter settings are:

Component Reference settings Interpretation
OxyR redox Kox = 0.36 nM−1 h−1; Kred = 28800 h−1; hO = 2 583 000 nM; total OxyR = 1000 nM Literature-derived settings18, with an explicit dimensional assumption for Kred
GrxA production Maximum 6000 nM h−1; threshold 100 nM; basal production 0 Fitted to single-cell data1619
KatG and TIP production Maximum 9000 nM h−1; threshold 180 nM; basal production 0 KatG settings fitted to single-cell data1619, and extended to TIP as a design assumption
AhpC production Maximum 12 000 nM h−1; threshold 100 nM; basal production 600 nM h−1 Fitted to single-cell data1619
Peroxide input Influx coefficient 60 h−1; basal production 1200 nM h−1 Prescribed external input1619; intracellular production2021
AhpC scavenging 2 376 000 h−1; peroxide threshold 1200 nM Upstream scavenging term21
KatG scavenging 1.764×109 h−1; peroxide threshold 5 900 000 nM Upstream scavenging term21
Growth dilution μ = 0.72 h−1 Fixed bacterial growth condition16
pKatG cooperativity Reference n = 3.5 Transferred assumption22; alternative values explored
TetR regulation aTetR = 50 nM h−1; KR = 0.44 nM; nTetR = 4; Pmin = 0.0056 Retained downstream reference settings8, not bacterial circuit measurements
TIP–TetR binding b = 4 nM−1 h−1; Kd = 0.001 nM Provisional binding assumptions; b from simulation-unit code23, Kd unsourced
Protein losses kdeg,TIP = 1 h−1; kdeg,TetR = δw = 0.12 h−1 Retained model assumptions; kdeg,TetR and δw from8
Reporter Production 50 nM h−1; maturation rates 7.39, 2.46, 1.37 h−1; degradation 0.01 h−1 Transferred reporter parameterisation

The source record associates the upstream backbone with Choudhary and colleagues1617, the gene-regulatory parameters with data fitted in16 and19, the alternative pKatG cooperativity with Kim and colleagues22, and downstream regulation with the Nevozhay modelling context8. Rogers and colleagues24 provide independent bacterial measurements of TetR cooperativity (n = 3.1–4.2) that bracket the retained value. These assignments do not make every retained value a direct measurement of the proposed bacterial circuit.

In particular, Kred is interpreted as a first-order coefficient in the implemented reduction term. The source defines it as a catalytic rate constant16, which requires units of inverse time, while its parameter list annotates it in µM s−1. The numerical conversion check tests consistency under the first-order interpretation.

The TIP–TetR affinity is not treated as experimentally measured. Its reference value is assessed through a dedicated affinity sweep. Retaining regulatory and reporter parameters also does not establish that their values are chassis-independent.

Scope of the transfer

The model uses fixed growth dilution and excludes growth-dependent feedback, spatial gradients and cell–cell interactions. The pKatG cooperativity and activation threshold originate from different experimental contexts — n = 3.5 from in vitro gel-shift measurements with purified protein22, the threshold from an in vivo fit performed at n = 11619 — motivating their joint exploration rather than assuming that the reference pair is uniquely established.

Evaluating the proposed transfer

Across eight simulated external peroxide concentrations from 12.5 to 100 µM, following the experimental dose grid of16, the reference feedback configuration produced a nearly linear relationship between dose and peak mature-green reporter concentration: R2 = 0.98452. Peak output increased from 2.816 to 35.114 nM, giving a 12.47-fold range, with peak times of approximately 67–95 min.

A control replacing TetR autoregulation with constant production reproduced the unstressed baseline at the reported precision. It reduced dose-response linearity to R2 = 0.77798 and dynamic range to 1.88-fold. At the two highest doses, the maximum occurred at the 30 h endpoint rather than at an internal peak.

Metric TetR autoregulation Constant TetR production
R2, maximum mature-green output versus dose 0.98452 0.77798
Maximum-output range 12.47× 1.88×
Mature-green maxima 2.816–35.114 nM 32.773–61.759 nM
Time of maximum 1.110–1.579 h 1.888–30 h

Parameter sweeps identified both tolerance and limits. Of 40 one-at-a-time settings, 33 satisfied all three performance criteria. All five tested TIP–TetR affinity values passed. In the joint cooperativity–threshold grid, eight of 25 combinations met the linearity criterion.

Together, these results support the computational feasibility of the proposed bacterial configuration and the contribution of autoregulation within that configuration. They also show that performance depends on parameter selection, particularly growth dilution, OxyR oxidation kinetics and TetR production. Experimental chassis transfer remains a separate validation step.

Two panels for the bacterial ICHNOS model across hydrogen peroxide doses of 12.5 to 100 micromolar. Panel A: maximum mature-green reporter concentration with TetR autoregulation versus constant TetR production, the autoregulated curve rising far more steeply. Panel B: time of maximum output during the 30 hour exposure, with open triangles marking control maxima that fall at the simulation endpoint.
Figure 4.1. Contribution of TetR autoregulation in the bacterial ICHNOS model. (A) Maximum mature-green reporter concentration across external H2O2 doses of 12.5–100 µM, with TetR autoregulation or constant TetR production. The respective dose-response R2 values were 0.98452 and 0.77798, with dynamic ranges of 12.47-fold and 1.88-fold. (B) Time of maximum output during the 30 h exposure. Open triangles identify control maxima occurring at the simulation endpoint; no interior peak was resolved for these conditions. Each circuit was initialised through zero-stress pre-equilibration. Green output denotes the mature reporter pool before FRET correction. Plotted points use rounded values from the MATLAB execution logs.
Simulation protocols, computational checks and scope

Unit-conversion verification

An independent Python check compared the five-state OxyR upstream formulation in min/µM and h/nM at corresponding physical times. At 100 µM external peroxide, the largest relative trajectory discrepancy was 1.488×10−9, below the specified 10−6 criterion.

Endpoint KatG comparisons at 12.5, 25, 50, 75 and 100 µM produced a maximum relative discrepancy of 6.636×10−11.

This verifies numerical agreement between two unit representations of the specified equations. It is not a Python–SBML comparison or an experimental validation.

Isolated downstream check

The isolated TIP–TetR module was simulated for 400 h under constant TIP-production inputs. The computed TetR and promoter-activity values reproduced the script's reference values at the displayed precision.

A 20-point sweep over 0–50 nM/h gave R2 = 0.99701 for promoter activity versus TIP-production rate. The imposed input is a production rate, not a clamped TIP concentration.

Coupled-model protocol

The MATLAB/SimBiology implementation used ode15s, relative tolerance 10−8 and absolute tolerance 10−10. Automatic unit conversion was disabled.

Before exposure, each circuit was simulated for 600 h at zero external peroxide. The resulting species values were assigned as the initial conditions for subsequent exposures. This is a prescribed pre-equilibration protocol rather than an independent steady-state convergence test.

Each exposure lasted 30 h, using constant external peroxide at 12.5, 25, 37.5, 50, 62.5, 75, 87.5 or 100 µM. Every dose started from the corresponding unstressed initial state.

Maxima and their times were extracted from the solver-returned trajectories. Values printed by the script as Green_ss are 30 h endpoints; they were not independently verified as steady states.

Readouts

The primary output was Rep_green, the mature-green molecular pool before the FRET correction. Linearity was calculated as the squared Pearson correlation between dose and the maximum of this output over the simulation window, equivalent to the R2 of a simple linear fit with an intercept.

Dynamic range was the largest dose-specific maximum divided by the smallest. It was not a fold change relative to the unstressed baseline.

The observation model separately calculated:

Rpool = Rdark + Rintermediate + Rmature

bFRET = Rmature Rpool + ε ,    Gobs = Gmature(1 − EFRET bFRET)

RatioRG = fcal Rmature Gobs + ε

The implementation used EFRET = 0.173, fcal = 1 and ε = 10−9 nM. Minimum ratio values were recorded during each exposure but were not the criterion used to establish peak-output linearity.

Autoregulation control

The control replaced aTetRP with constant TetR production of 1.045265 nM h−1. Other model settings were retained, and each circuit underwent its own zero-stress pre-equilibration.

The reported basal TetR, mature-green, mature-red and ratio values agreed at the displayed precision. This controls for the unstressed operating point while testing the response to removal of TetR autoregulation.

Parameter sweeps

Sensitivity analysis used five doses: 12.5, 25, 50, 75 and 100 µM. Its five-dose baseline R2 = 0.9858 is therefore distinct from the eight-dose value of 0.98452.

Each setting was assessed against three implemented criteria: R2 ≥ 0.95; dynamic range ≥ 3; and range of dose-specific times of maximum ≤ 3 h.

The one-at-a-time analysis varied b, kdeg,TIP, aTetR, μ, KR, δw, Kox and KKatG by factors of 0.1, 0.5, 1, 2 and 10. Thirty-three of 40 settings passed all three criteria. This count includes the repeated baseline setting for each parameter.

Failures occurred at aTetR ×0.1; μ ×0.1, ×2 and ×10; and Kox ×0.1, ×2 and ×10. The reported sensitivity coefficient describes the relative change in dynamic range between the baseline and a twofold parameter increase, rather than an infinitesimal derivative.

The affinity sweep tested Kd = 0.001, 0.01, 0.1, 1, 10 nM. All five settings passed the three criteria.

The two-dimensional sweep combined n = 1, 2, 3, 3.5, 4 with activation thresholds of 45, 90, 180, 360 and 720 nM. KatG and TIP thresholds were changed together. Eight of 25 combinations achieved R2 ≥ 0.95; this count concerns linearity alone.

The sweeps describe performance over selected parameter values. They do not provide a probability of successful experimental transfer or establish robustness to all simultaneous parameter changes.

5. Circuit characterisation

We characterised the integrated PULSE model to ask how reporter output varies with stress dose, how sensitive that response is to uncertain parameters, and what TetR negative autoregulation contributes. The simulations support a broader dose-response range with autoregulation, while identifying sensor calibration, TIP–TetR affinity and exposure history as priorities for further testing.

Each result belongs to a specified dose window, readout time and input protocol. Here we use the frozen sensitivity-analysis configuration, with constant stress as the reference and 3 h as the primary comparison time. These are computational predictions, not experimental validation of the complete circuit.

5.1 Dose response characterisation using Hill fitting

We extracted Observed_Green at fixed times from dynamic simulations and fitted a four-parameter Hill curve. Its effective exponent, neff, summarises the shape of the integrated output across the tested doses. It is distinct from the sensor Hill coefficient and the exponent governing TetR repression; it should not be interpreted as molecular binding stoichiometry.

We assessed response shape with three complementary quantities: neff for steepness, linear-fit R2 for agreement with a straight line, and fold change for the output range. A smaller neff alone does not demonstrate linearity, and a flat response can have little useful dose contrast. These metrics describe deterministic curves; they do not quantify discrimination in the presence of measurement noise.

Full circuit at 3 h neff Linear R2 Fold change
OX 20–300 µM H2O2 1.796 0.947 4.244
ER 700–3200 µM DTT 2.572 0.960 2.977

The OX baseline has a lower effective exponent than the ER baseline, yet both are approximately linear over their selected windows. The comparison figure in Section 5.3 shows why the output range and saturation pattern must be considered alongside neff.

Hill fitting method

We fit G(S) = base + amp × Sn / (Kn + Sn), with n = neff, directly to the simulated output. Initial guesses are min(G), max(G) − min(G), median(S) and 1.5. SciPy curve_fit constrains K and n to at least 10−12, leaves base and amp unconstrained, and uses maxfev = 400000. K is a fitted response scale, not the TIP–TetR dissociation constant.

Linear R2 is calculated independently by ordinary least squares with an intercept; fold change is max(G)/min(G) over the dose grid. The workflow exports point estimates, not confidence intervals for neff. Fits to eight doses can be weakly constrained when the response is flat or saturated, so we interpret the fitted exponent together with the plotted response and the other metrics.

5.2 Sensitivity analysis

We varied one parameter at a time to separate three questions: how the output changes near a reference value, how far it moves across a declared uncertainty sweep, and how it changes when stress decays instead of remaining constant. This distinction makes the analysis useful for deciding what to measure next without presenting scenario ranges as statistical confidence.

Among the selected OX parameters evaluated locally, sensor cooperativity nox has the largest response coefficients. Its coefficient for output neff is +0.874, compared with −0.271 for Kact,ox and about +0.02 for the downstream repression parameters. Sensor calibration therefore strongly affects the predicted output shape. This is a ranking of the analysed metrics near this baseline, not a ranking of linear R2 or a proof that downstream feedback is unimportant.

Horizontal bar chart of local response coefficients for the oxidative branch. n_ox has the largest bars across all four metrics; K_act_ox is smaller and mixed in sign; the TetR repression exponent and K_R are near zero for most metrics.
Figure 5.1. OX local response coefficients from the original sensitivity plotting script. Positive values indicate that increasing a parameter increases the metric. n denotes TetR repression; its estimate is one-sided because the baseline lies at the sweep boundary. tpeak refers to sensor activity, not reporter fluorescence.

The parameter groups reflect the evidence used to select nominal values. A literature-derived or previously fitted value is not, by itself, proof of identifiability in the integrated model. Local coefficients remain conditional on the chosen baseline and on all other parameters being held fixed.

Uncertainty affects different outputs differently

A stable Hill exponent does not imply a robust timer. Across the OX buffer-loss sweep, neff changes little (max/min ≈ 1.01), while ratio spread changes by a factor of 5.86. Across the TIP–TetR affinity sweep, fold change spans a factor of 2.98 and ratio spread a factor of 3.74. These results motivate measurements of affinity and adaptation dynamics, rather than relying only on a good-looking dose-response curve.

Ranges of each oxidative metric across the declared one-at-a-time parameter sweeps, each endpoint divided by its baseline value.
Figure 5.2. OX metric ranges over the declared one-at-a-time sweeps. Endpoints are divided by the baseline; labels give maximum/minimum over each sweep. The intervals are deterministic response ranges.

The ER branch is more dependent on its uncertain sensor parameterisation. Sweeping Kact,er changes the maximum sensor peak time by a factor of 6.11; sweeping ner changes output neff by a factor of 2.32. The ER calibration should therefore remain provisional when interpreting downstream circuit behaviour.

Ranges of each ER metric across the declared one-at-a-time parameter sweeps.
Figure 5.3. ER response ranges. Sweep widths represent different assumptions; range size is not an intrinsic ranking of parameter importance.
Scope of the ranking

Local coefficients approximate d ln(M)/d ln(p) using the two available sweep points neighbouring the baseline, or a one-sided estimate at a boundary. Broad sweeps report max(M)/min(M).

A gradient-boosted surrogate was also fitted to the sweep and its SHAP ranges compared with the directly computed output ranges. On a one-at-a-time design these are the same quantity by construction, and the surrogate reproduced it with a 1–11% shrinkage while failing to report three of eight analysis units that the direct statistic answers. The direct range is therefore the adopted statistic.

One-at-a-time sweeps cannot identify interactions, so we measured them directly: every pair of swept parameters in both branches was crossed, 56 pairs in total, with each interaction normalised by the combined one-at-a-time effects. Non-additivity is pervasive rather than localised: at the 1 h readout only 2 of 49 scoreable pairs are additive. Variance-based global analysis remains a future extension for interactions above second order.

Exposure history changes the interpretation

We compared constant stress with exponential clearance, dS/dt = −kclearS. These scenarios change the input history while retaining the same circuit. The tested rates are 0, 0.693 and 1.777 h−1. They explore dependence on the exposure assumption; they are not measured clearance constants for the complete biological setting, and they are distinct from the fitted rates reported in the physics-informed section.

Four panels comparing the oxidative branch under constant and decaying stress: output fold change and fitted n_eff at 1, 3 and 6 hours above, sensor peak-time ranges and residual activity below.
Figure 5.4. OX response under constant and decaying stress. Upper panels show output fold change and fitted neff at 1, 3 and 6 h. Lower panels describe sensor activity A: peak-time ranges and residual activity relative to its peak. They do not measure fluorescent reporter memory.

At 3 h, OX fold change falls from 4.244 under constant stress to 2.863 and 1.842 in the clearance scenarios, while ratio spread rises from 0.040 to 0.214 and 0.279. A lower neff therefore coincides with less output contrast and greater dose dependence of the ratio. Exposure history must be specified before interpreting the ratio as a timer.

Three hours is a common reference for this comparison, not an optimised readout time. The corresponding ER scenario figure is supplied as a supplementary PNG; applying the same clearance rates to ER is a sensitivity scenario, not an independently calibrated DTT-clearance model.

5.3 Comparison circuit

We constructed a matched control to isolate TetR negative autoregulation. In the full circuit, promoter activity regulates TetR production as well as reporter production. In the control, TetR production uses a fixed promoter-activity value; reporter repression by TetR is retained. The sensor, binding module and reporter are otherwise shared.

Left panel: absolute dose-response curves for the full circuit and the no-autoregulation control. Right panel: the same curves normalised to their own minimum and maximum, with TIP production and a linear reference for comparison.
Figure 5.5. Full circuit and matched control at 3 h. Left: absolute model output. Right: each curve normalised to its own sampled minimum and maximum, with TIP production and a linear reference. Points are simulated dose responses joined by lines; the displayed neff values come from Hill fits.

Removing autoregulation produces early saturation, especially in OX. Restoring it raises OX fold change from 1.756 to 4.244 and linear R2 from 0.370 to 0.947. These values come from the frozen sensitivity-analysis configuration and compare the full circuit with the no-autoregulation control; they are not comparable with the static-versus-adaptive sensor figures reported in the ablation study, which use a different protocol. In the model, relief of TetR repression also increases TetR replenishment, which is consistent with delaying reporter saturation and retaining differences between intermediate doses.

The ER branch also gains output range and linearity, but its ratio spread increases from 0.061 to 0.082; OX ratio spread decreases from 0.079 to 0.040. Feedback therefore improves selected response properties rather than every metric. This targeted comparison supports a mechanistic role for autoregulation under the declared conditions; the later ablation study addresses broader circuit components and decoding.

Control construction and comparison metrics

The control is generated from the same merged SBML by finding the TetR-producing reaction whose kinetic law contains promoter activity P. Only that occurrence is replaced by P_open_control. The reporter retains its original dependence on P, so TetR continues to repress reporter expression but no longer regulates its own synthesis.

P_open_control is obtained from the full circuit after a zero-stress simulation to 200 h: 0.055190 for OX and 0.020212 for ER. This matches the nominal basal operating point. It does not pre-equilibrate each dose simulation: both circuits are reset to their source initial state before every dose.

Branch and circuit neff Linear R2 Fold Ratio spread
OX control 3.749 0.370 1.756 0.079
OX full 1.796 0.947 4.244 0.040
ER control 5.134 0.412 1.857 0.061
ER full 2.572 0.960 2.977 0.082
Sensitivity protocol and metrics

Each branch is simulated independently for 0–6 h with 4000 output points. Readouts at 1, 3 and 6 h use the nearest sampled time. OX doses are 20, 40, 70, 110, 150, 208, 260 and 300 µM H2O2; ER doses are 700, 1000, 1300, 1500, 1800, 2200, 2700 and 3200 µM DTT. No final state is carried between doses.

Parameter Declared grid
Kact,ox or Kact,er×0.5, 0.75, 1, 1.5, 2
nox or ner×0.5, 0.75, 1, 1.25, 1.5
kon or koff for the sensor×0.25, 0.5, 1, 2, 4
dx,ox0, 0.1, 0.5, 1, 2, 4 h−1
dx,er0, 0.01, 0.05, 0.2, 0.5 h−1
KR×0.05, 0.5, 1, 3, 5
n for TetR repression×0.5, 0.75, 1
Kd,TIP–TetR×0.01, 0.1, 1, 10, 100; baseline 0.25 nM

Multipliers apply to nominal model parameters; buffer-loss grids are absolute. Ratio spread is (maximum − minimum)/mean of Measured_Ratio_RG across doses at a fixed time. For each dose, sensor peak time is the time of maximum A; the scalar tpeak used in the sensitivity plots is the largest of those peak times over the dose grid. The scenario plots also display the minimum peak time.

Implementation and reproducibility

Software and model configuration

The sensitivity and comparison analyses use an integrated SBML model combining the oxidative or ER stress sensor, the TIP–TetR regulatory module and the tandem reporter. Simulations were performed using Tellurium/RoadRunner, with python-libSBML for model handling and SciPy for nonlinear Hill fitting. Source-model checks confirmed that the oxidative SBML matched the recorded reference configuration, including its parameter values and constant-stress input formulation.

Numerical settings

Simulations cover 0–6 h with 4,000 output points, using absolute and relative solver tolerances of 10−12 and 10−10, respectively. Each dose is simulated independently from the model's reset state, without carrying the final state of one simulation into the next. Outputs are evaluated at 1, 3 and 6 h, with 3 h used as the primary comparison time. Hill fitting constrains the activation scale and effective exponent to positive values, while allowing the fitted baseline and amplitude to vary freely.

Computational checks

The analysis workflows were rerun following code reorganisation and the introduction of positive bounds in Hill fitting. Comparisons with saved outputs showed small numerical changes in the fitted effective Hill coefficient, without changing the reported conclusions. The fitting update did not modify the source SBML or the recorded oxidative baseline of Kact,ox = 208 µM and nox = 2.75. These checks support consistency of the computational implementation; they do not establish experimental validity of the complete biological circuit.

Connection to the affinity analysis

The affinity sweep changes output range and ratio stability much more than it changes the fitted Hill exponent. This motivates the next analysis of TIP–TetR binding affinity: which affinity range preserves useful signal contrast, and how robust is that conclusion to uncertain sensor dynamics? That is the reason why a Kd-specific analysis follows.

6. Kd-specific analysis

Following the initial sensitivity analysis, we examine TIP–TetR binding affinity in greater detail. We describe the affinity-estimation and uncertainty workflows used to investigate how variation in Kd affects circuit performance and to identify requirements for experimental calibration.

Connecting binding uncertainty to circuit performance

TIP–TetR binding connects stress-dependent TIP production to promoter regulation. Its dissociation constant, Kd, therefore sets how strongly a change in sensing is transmitted to the reporter.

We treated Kd as an uncertain model parameter rather than an experimentally measured property of the constructed circuit. The analysis combined structure-derived affinity predictions, deterministic circuit simulations and uncertainty propagation to ask whether plausible binding affinities satisfy defined response criteria.

The frozen model, meaning the locked reference parameterisation used throughout this section, stores a value of 0.25 nM, retained for traceability. It was not interpreted as a measured affinity or as the centre of the structural uncertainty distribution.

Defining a response window

We varied Kd over 0.0025–5000 nM while retaining the remaining frozen-model settings. Increasing Kd, corresponding to weaker binding, progressively reduced dose-dependent reporter contrast in both sensing variants.

At the primary readout of 3 h, we applied two operational criteria: an observed-green fold-change of at least 1.5 across the tested doses and a relative red-to-green ratio spread no greater than 0.20. Both are operational assumptions rather than measured instrument limits, and the effect of the ratio threshold on which criterion binds is recorded in the dropdown.

Frozen variant Approximate upper Kd boundary
OX30.2 nM
ER5.74 nM
Joint OX and ER5.74 nM

The ER branch imposed the tighter joint requirement. The ratio-spread criterion was satisfied throughout the simulated grid, so reporter contrast determined the upper boundary under these conditions.

These boundaries describe the selected dose grids, readout time and operational thresholds. They are not universal affinity requirements or experimentally measured detection limits.

Observed-green fold-change at 3 hours plotted against TIP–TetR dissociation constant on a logarithmic axis, for the frozen OX and ER models. Both curves fall as Kd increases and cross a dashed 1.5-fold threshold, OX at about 30 nM and ER at about 5.7 nM, with a shaded band spanning the two structure-derived estimates.
Figure 6.1. Effect of TIP–TetR binding affinity on predicted reporter contrast. Observed-green fold-change at 3 h across the specified dose grids for the frozen OX and ER models. Increasing Kd reduces reporter contrast. The dashed line marks the assumed 1.5-fold acceptance threshold, with approximate crossings at 30.2 nM for OX and 5.74 nM for ER. The shaded band spans the two structure-derived point estimates, 3.675–8.428 nM; it is not an uncertainty interval. The fold threshold is an operational assumption rather than a measured instrument detection limit.
Binding formulation, simulation protocol and response criteria

Affinity parameterisation

The model represents reversible association of free TIP and active TetR:

TIP + TetR ⇌ TIP:TetR

The association coefficient b was held fixed, while dissociation followed:

uw = bKd

Consequently, this sweep changes affinity through the dissociation coefficient. It does not explore all possible association and dissociation kinetics that could produce the same Kd.

Simulation protocol

The deterministic analysis used 28 absolute Kd values between 0.0025 and 5000 nM, including denser coverage around the few-nM region.

The frozen OX dose grid was 20, 40, 70, 110, 150, 208, 260 and 300 µM. The frozen ER grid was 700, 1000, 1300, 1500, 1800, 2200, 2700 and 3200 µM.

Each dose was simulated from the source model's initial state after resetting the model, without a separate pre-equilibration stage. Stress remained constant during each frozen-model exposure. Simulations covered 0–6 h with 4,000 output points, using absolute and relative integration tolerances of 10−12 and 10−10, respectively.

Outputs were sampled at the grid points nearest 1, 3 and 6 h. The primary assessment used the 3 h readout.

Response metrics

Let Gi denote Observed_Green at the selected readout for dose i. Reporter contrast was defined as:

F = maxi Gi mini Gi

This compares the highest and lowest observed-green outputs across the specified dose grid. It is not a comparison against a zero-stress control.

For the corresponding Measured_Ratio_RG values, ri, relative spread was:

Dr = maxi ri − mini ri meani(ri)

The operational acceptance criteria were:

F ≥ 1.5,     Dr ≤ 0.20

The fold threshold remains an assumption until instrument-specific background and detection measurements are available. The ratio threshold of 0.20 was applied here rather than the stricter 0.05 set as the configuration default. The choice determines which criterion binds: because ratio spread increases as binding tightens, a threshold of 0.05 imposes a lower boundary on the ER branch at approximately 3.16 nM, giving a two-sided window of 3.16–5.74 nM, whereas at 0.20 the ratio criterion is satisfied across the grid and reporter contrast alone sets the boundary. The ratio threshold assesses limited dose dependence at the selected readout; it does not independently establish accurate time decoding.

Boundary estimation

Response curves were interpolated between simulated Kd values to estimate threshold crossings. The window analysis returned approximately 30.217 nM for OX and 5.743 nM for ER.

The Monte Carlo propagation used its own interpolation procedure and returned closely matching boundaries of 30.196 and 5.742 nM. We therefore report rounded boundaries of 30.2 and 5.74 nM rather than implying greater precision.

No lower boundary from the ratio criterion was detected within the simulated domain at the 0.20 threshold. This does not establish behaviour below the minimum tested Kd of 0.0025 nM.

Comparing structural predictions with circuit requirements

The structural analysis supplied two binding-energy predictions for TIP interacting with TetR dimers in the experimental 2NS8 structure. At 30 °C, the recorded values of −11.2 and −11.7 kcal/mol corresponded to Kd estimates of 8.428 and 3.675 nM.

These point estimates lie on opposite sides of the joint frozen-model boundary: 3.675 nM satisfies the selected criteria, whereas 8.428 nM does not. Their geometric centre, 5.565 nM, is close to the ER boundary.

The comparison therefore does not support a definitive classification from a single structural estimate. We propagated an explicit prediction-uncertainty model through the circuit-response curves.

Structural estimates and uncertainty propagation

Structural inputs

The recorded energy predictions correspond to the A+B+H and C+D+F assemblies of 2NS8. They represent two interfaces within the same experimental structure, not two independent affinity measurements.

The current executions used these stored energy estimates as inputs. They did not rerun the structural affinity-prediction calculation.

Using a 1 M standard-state convention, the conversion was:

Kd [nM] = 109 exp ΔG RT

with T = 303.15 K and R = 1.987204×10−3 kcal mol−1 K−1.

Assumed uncertainty distribution

We assigned equal weight to the two structural energy estimates and used a Gaussian energy uncertainty of 1.5 kcal/mol around each estimate. This uncertainty is an analysis assumption rather than a measurement of TIP–TetR variability.

Transforming the energy samples produced a broad distribution of Kd. With 200,000 Monte Carlo samples, its median was 5.597 nM and its central 90% interval was 0.087–355.947 nM.

Coverage of the deterministic grid

Of the structural samples, 0.1195% fell below the deterministic grid and 0.3475% above it. The remaining 199,066 samples, representing 99.533% of the total, were propagated through the response curves.

Samples outside the grid were left unresolved rather than assigned the response at the nearest simulated boundary.

The same sampled Kd was used for OX and ER when assessing joint satisfaction of the criteria.

Interpreting the propagated uncertainty

Under the assumed structural uncertainty and operational criteria, 74.99% of in-grid samples satisfied both criteria for OX. For ER, and consequently for joint OX–ER satisfaction, the corresponding fraction was 50.52%.

Assessment Fraction satisfying both criteria, conditional on grid coverage
Frozen OX74.99%
Frozen ER50.52%
Joint frozen OX and ER50.52%

Relative to all 200,000 samples, the resolved jointly passing mass was 50.29%; 0.467% remained unresolved outside the simulated grid.

The ratio-spread criterion passed for every propagated in-grid sample. The fold criterion therefore determined the reported passing fractions.

These fractions quantify compatibility between the assumed affinity distribution and the selected model-response criteria. They are not experimentally measured probabilities that the circuit will function.

Probability density of the structure-derived Kd prior on a logarithmic axis, with a shaded region marking affinities that satisfy both the OX and ER circuit criteria and dotted lines at the two structural point estimates.
Figure 6.2. Structural affinity uncertainty relative to the joint circuit-response window. The structure-derived prior combines two binding-energy predictions with equal weights and an assumed Gaussian uncertainty of 1.5 kcal/mol per prediction. The curve shows probability density per unit ln(Kd/1 nM), displayed on a logarithmic Kd axis without renormalisation to the plotted domain. The shaded area identifies affinities satisfying both frozen OX and ER criteria at 3 h: observed-green fold-change ≥ 1.5 and relative red-to-green ratio spread ≤ 0.20. Dotted lines mark the two structural point estimates. No experimental observations were used to update this prior.
Bayesian interpretation and scope

The Bayesian workflow was executed without experimental observations. It therefore summarised a structure-derived prior only; no experimentally updated posterior was obtained.

On its finite logarithmic grid of 0.0025–5000 nM, the prior-only calculation reported a median of approximately 5.5 nM and a central 90% interval of approximately 0.1–326.6 nM. This differs slightly from the Monte Carlo summary because the finite-grid calculation normalises the distribution within its specified domain.

The prior-only result does not provide independent confirmation of the structural estimates or circuit predictions. Future experimental updating would require measured reporter responses, their uncertainty and a compatible observation model.

The present analysis identifies binding affinity as a consequential uncertainty: the structural distribution spans both passing and failing response regions, with its centre close to the ER constraint. Direct affinity measurements and instrument-specific response thresholds would therefore materially improve the assessment.

Physics-informed changes to sensing parameters and input histories are evaluated separately, so that their effects are distinguished from affinity uncertainty in the frozen reference models.

7. Model evaluation and dose–time decoding

7.1 Physics-informed modelling

Examining how stress-input dynamics shape circuit behaviour.

The adaptive sensing modules describe activation and feedback following stress onset. However, the observed response also depends on the history of the stress input. A declining response can therefore reflect intracellular adaptation, a reduction in the effective input, or a combination of both.

We compared the reference constant-input models with scenarios incorporating a declining effective stress input. We then propagated these scenarios through the integrated circuit to examine their consequences for TIP production, fluorescence and the inferred functional binding-affinity range. For the oxidative branch this changed the engineering conclusion qualitatively rather than marginally: the frozen model has a functional binding-affinity region, and neither declining-input scenario has one under the same three-hour criteria.

Effective-input dynamics and scenario definitions

The reference, or frozen-input, configurations maintain a constant stress input throughout the simulation. The alternative scenarios introduce first-order effective-input decay:

dSdt = −kclearS,     S(t) = S0e−kcleart

Here, S0 is the initial effective stress input and kclear determines its rate of decline. The corresponding half-life is:

t1/2 = ln 2 kclear

This formulation describes the effective input experienced by the sensing module. It does not establish that extracellular stress concentration follows the same decay law.

For ER sensing, the M2 scenario combines a coherent fitted sensor parameter set with effective-input decay. Cooperativity is fixed at n = 4, and kclear = 0.5032 h−1, corresponding to a half-life of approximately 1.38 h. The fitted activation and feedback parameters are applied together.

For oxidative sensing, the canonical sensor kinetic parameters are retained while the effective-input history is varied. The reference scenario uses kclear = 1.95 h−1, and the systematic alternative uses 3.30 h−1, corresponding to half-lives of approximately 21.3 and 12.6 min, respectively.

Sensing branch Scenario Effective-input decay Sensor kinetics
OXFrozenNoneCanonical
OXPI reference1.95 h−1Canonical
OXPI systematic3.30 h−1Canonical
ERFrozenNoneCanonical
ERM2, n = 40.5032 h−1Coherent M2 fitted set

The oxidative alternatives represent scenarios derived from different data-quantification approaches. They are not confidence-interval endpoints and are not assigned probabilities. The ER alternative changes both sensor parameterisation and input dynamics; its comparison with the frozen configuration therefore assesses their combined effect.

Distinguishing fit quality from parameter identifiability

A model can reproduce an observed response without uniquely determining the parameters or mechanisms responsible for it. We therefore examined whether improved fits supported a unique sensor parameterisation or instead remained compatible with alternative explanations.

This distinction guided the scenario strategy. For oxidative sensing, we retained the canonical kinetics and varied the effective-input history. For ER sensing, we implemented the coherent M2 fitted parameter set as a separate scenario, without replacing the canonical model.

Evidence supporting the scenario choices

Oxidative sensing

The oxidative calibration dataset combines a time course at one stress dose with a dose-response measurement at one observation time. This provides limited information for separating intracellular adaptation from a decline in effective stress input.

Allowing effective-input decay improved the fit across the examined quantification and weighting approaches. The residual sum of squares decreased by approximately 90–92%, with AICc differences favouring the declining-input formulation by approximately 23–27 units. These comparisons support examining a declining-input alternative, but do not establish its biological mechanism.

Fitted internal kinetic parameters also varied with the data-quantification approach. We therefore did not adopt a single refitted kinetic vector as a replacement for the canonical model. Instead, we retained the canonical kinetics and introduced the reference and systematic effective-input scenarios described above.

This choice allows the downstream consequences of input uncertainty to be examined without presenting one fitted parameter set as uniquely identified.

ER sensing

The ER runtime scenario uses the complete M2 parameter set with cooperativity fixed at n = 4. The activation, feedback and effective-input parameters are transferred together, preserving the configuration used during calibration.

Parameter ER M2 value Unit
Kact929.5µM
n4, fixedDimensionless
kon3.474h−1
koff13.674h−1
kx1, fixedh−1
dx1.755h−1
kclear0.5032h−1

Here, kon and koff describe sensor activation and feedback-mediated inactivation; they are distinct from the TIP–TetR association and dissociation parameters.

The M2 scenario provides a defined configuration for propagation through the circuit. Its use does not establish that effective-input decay and intracellular adaptation have been uniquely separated by the calibration data.

Verifying runtime implementation

We implemented the scenarios in memory while preserving the source SBML files. Before examining circuit behaviour, we verified that the frozen configurations reproduced the reference dynamics and that the declining inputs followed the prescribed exponential trajectories.

For ER, we additionally compared the runtime SBML with the calibration ODE at both calibration doses. These checks established numerical consistency between implementations; they did not establish a unique biological explanation for the fitted response.

Runtime validation and model preservation

Reference-model preservation

Frozen regression checks confirmed that the scenario workflow retained the reference behaviour when no physics-informed changes were applied. The OX checks additionally verified that the declining-input scenarios preserved the canonical sensor kinetic parameters.

For ER, the fitted parameters were applied as a complete set and reapplied after simulator resets. This ensured that resetting the simulator did not silently restore the canonical values during a scenario-specific analysis.

Effective-input trajectories

The simulated stress inputs were compared with the analytical solution:

S(t) = S0e−kcleart

Both sensing branches passed their documented input-trajectory checks. This verifies that the runtime implementation follows the specified input history.

ER calibration-to-runtime agreement

The ER comparison used matched parameters, initial conditions, time units and initial stress doses of 1500 and 2200 µM. Sensor activation, feedback and effective-input trajectories were compared between the calibration ODE and the runtime SBML.

Across the two doses, the maximum absolute discrepancies were approximately 1.44×10−6 for the dimensionless activation state, 4.22×10−7 for the dimensionless feedback state and 1.84×10−5 µM for the effective input. The comparison passed the specified numerical checks.

Agreement at these doses supports faithful transfer of the calibration equations into the runtime model. Predictions at other doses remain model extrapolations and are distinguished from this implementation check.

Propagating uncertainty to circuit outputs

We propagated the scenarios through the integrated sensing, TIP–TetR and tandem reporter modules. This allowed us to examine whether changes in sensor dynamics persisted in downstream observables.

The consequences depended on the sensing branch, operating conditions and observable. The oxidative scenarios changed absolute reporter outputs substantially, whereas the ER comparison showed that a nearly unchanged reporter ratio can coexist with large changes in internal sensor states.

Six panels over six hours: free TIP, observed green fluorescence and measured red-to-green ratio for the oxidative branch on the top row and the ER branch on the bottom row, comparing frozen and declining-input scenarios. The oxidative curves separate clearly; the ER curves nearly overlap.
Figure 7.1. Propagation of effective-input scenarios through the integrated circuit. Free TIP, observed green fluorescence and measured red-to-green ratio over six hours for the oxidative (top row; initial input 400 µM) and ER (bottom row; initial input 100 µM) variants. Simulations start from the model's reset state without pre-equilibration. Oxidative declining-input scenarios retain canonical sensor kinetics, whereas ER M2 combines fitted sensor parameters with declining input. ER trajectories nearly overlap at this operating point, which lies outside the 1500–2200 µM calibration range. Concentrations are shown in native model units.
Full-circuit propagation

Comparison protocol

Each scenario was applied to the corresponding merged circuit, starting from the model's reset initial conditions. Within each branch, the frozen and physics-informed simulations used the same initial stress input and downstream configuration. Scenario-specific changes were applied before simulation.

Sensor activation, feedback, free TIP and reporter outputs were examined separately. Absolute reporter quantities and the red-to-green ratio were treated as distinct observables: agreement in a ratio does not imply agreement in its component signals.

Oxidative sensing

Both declining-input scenarios reduced downstream output relative to the frozen configuration. At the reported two-hour checkpoint, free TIP decreased by approximately 82% in the reference scenario and 86% in the systematic alternative. Observed green output decreased by approximately 49% and 60%, respectively, while the total red pool decreased by approximately 50% and 61%.

The reporter response therefore retained substantial consequences of the altered input history. Changes in the ratio were time-dependent and could differ in direction from changes in absolute output.

ER sensing

At the native merged-model input of S0 = 100 µM, the M2 scenario produced large relative changes in the effective input and sensor states. At three hours, the effective input was approximately 78% lower than in the frozen configuration, while sensor activation was approximately 193% higher.

At the same checkpoint, the measured red-to-green ratio changed by only approximately −0.03%. At this input both configurations remain far below their activation thresholds, so the unchanged ratio reflects an operating point where the sensor is not responding rather than insensitivity of the observable itself. A propagation inside the 1500–2200 µM calibration range remains to be run.

This comparison is therefore an operating-point exploration, distinct from the calibration-to-runtime agreement checks.

Implications for circuit assessment

These comparisons show why internal states, absolute fluorescence and fluorescence ratios must be inspected together. A stable ratio can conceal changes elsewhere in the circuit, while reporter maturation can preserve the effects of an earlier input after the effective stress has declined.

We therefore assessed binding-affinity robustness separately across the specified dose grids, rather than inferring it from a single operating-point comparison.

Testing whether binding-affinity conclusions depend on stress-input dynamics

We examined whether the functional binding-affinity ranges identified under constant stress were preserved in the physics-informed scenarios. At a three-hour readout, we required a fluorescence fold-change of at least 1.5 across the tested doses and a relative reporter-ratio spread of no more than 0.05.

The frozen configurations shared a functional interval of approximately 3.16–5.74 nM. No overlapping interval satisfied both criteria in the ER M2 configuration or either oxidative declining-input scenario.

These results show that the inferred affinity requirements depend on the sensor configuration and effective-input history. The absence of overlap applies to the specified readout, dose ranges and operational criteria; it does not establish experimental failure of the circuit.

Green fluorescence fold-change and relative red-to-green ratio spread at three hours plotted against TIP–TetR binding affinity, with dashed operational thresholds, and right-hand panels showing where the two criteria overlap for each scenario.
Figure 7.2. Dependence of binding-affinity robustness on sensor and input assumptions. Green fluorescence fold-change across doses (left) and relative red-to-green ratio spread (centre) at three hours, plotted against TIP–TetR binding affinity. Dashed lines indicate the operational thresholds of fold-change ≥ 1.5 and ratio spread ≤ 0.05. Right-hand panels show their overlap within the simulated range of 0.0025–5000 nM; dark bands indicate joint satisfaction and grey indicates the remaining sampled domain. Boundaries use interpolation in log-transformed Kd. The frozen configurations retain feasible intervals, whereas ER M2 and both oxidative declining-input scenarios show no overlap under these criteria.
Binding-affinity assessment and interpretation

Affinity sweep and output criteria

The TIP–TetR association coefficient b was held fixed, while the dissociation rate followed:

uw = bKd

For each sensing branch and scenario, outputs were evaluated across the corresponding stress-dose grid at three hours. The fluorescence fold-change was defined as:

F = maxi Gi mini Gi

where Gi is the observed green output at dose i. This compares the highest and lowest outputs across the tested doses, rather than stimulated output against a zero-stress baseline.

The relative spread of the red-to-green ratio was:

ΔR = maxi Ri − mini Ri meani Ri

The joint operational criteria were:

F ≥ 1.5,     ΔR ≤ 0.05

The ratio-spread threshold is stricter than the 0.20 criterion used in the preceding structural-affinity analysis. Results under these two thresholds are reported separately.

Scenario-specific functional ranges

Scenario Fold-change criterion Ratio-spread criterion Joint outcome
OX frozen Kd ≲ 30.22 nM Satisfied throughout the simulated grid Feasible up to approximately 30.22 nM
ER frozen Kd ≲ 5.74 nM Kd ≳ 3.16 nM Approximately 3.16–5.74 nM
ER M2 Kd ≲ 4.43 nM Kd ≳ 8.71 nM No overlap
OX PI reference Kd ≲ 1.72 nM Kd ≳ 51.67 nM No overlap
OX PI systematic Kd ≲ 0.354 nM Kd ≳ 38.12 nM No overlap

Boundaries are approximate threshold crossings inferred from the simulated sweeps. The OX frozen feasible range extends down to the lowest simulated value, 0.0025 nM; behaviour below that bound was not assessed.

Interpretation

In the physics-informed scenarios, the affinity ranges supporting sufficient fluorescence contrast did not overlap with those satisfying the stricter ratio-spread criterion. The ER comparison includes changes in both fitted sensor parameters and input dynamics, whereas the oxidative comparisons retain the canonical sensor kinetics and vary the input history.

A small ratio spread alone does not establish a useful timer: ratio similarity across doses can persist even when fluorescence contrast approaches unity. Likewise, satisfying both criteria does not independently demonstrate accurate elapsed-time estimation. The joint assessment identifies conditional model-performance ranges for subsequent experimental evaluation.

7.2 Ablation study

Testing the contribution of circuit components

ICHNOS links stress sensing to TIP production, TetR regulation and a tandem fluorescent reporter. Which features help distinguish stress doses, and which preserve information about when exposure began? We addressed these questions by removing or modifying one mechanism at a time in the integrated model and comparing each variant with the intact circuit under the same simulation protocol.

The analysis separated two contributions: feedback helped maintain a discriminating dose response, while different reporter maturation times supported temporal information. It also exposed limits: a favourable response shape did not guarantee a useful signal, and theoretical inference precision depended on event age and measurement noise.

These are dependencies within the model. They support design reasoning and identify priorities for experimental testing; they do not establish that the corresponding mechanisms are biologically necessary in vivo.

Functional map of the integrated model showing sensing, TIP production, TetR regulation and the tandem reporter, with the points at which each ablation intervenes.
Figure 7.3. Functional map of the model and the intervention targets. FRET correction belongs to the observation model; it is not a biological circuit component.
Intervention Function examined
Remove TetR autoregulationContribution of regulatory feedback
Remove sensor feedbackContribution of adaptation
Set adaptation-mediator decay to zero in OXEffect of adaptation depth
Match mean red and green maturation timesContribution of different maturation dynamics
Remove basal TIP productionContribution of sensing-module leakiness
Remove FRET correctionContribution of the observation model

The oxidative module (OX) is the main quantitative example below. ER results remain descriptive because its sensing parameters are provisional. Setting adaptation-mediator decay to zero is not a separate ER intervention: that parameter is already zero in the reference ER model.

Measuring changes in function

We assessed response linearity, signal range and joint dose–time information. These metrics answer different questions. A lower fitted Hill coefficient does not by itself demonstrate linearity, and a dose-independent red/green ratio is not useful if the fluorescence barely responds.

Three panels comparing oxidative interventions: straight-line R-squared, high-over-low green signal ratio against a twofold threshold, and timing Cramér–Rao bound relative to the intact model on a logarithmic axis.
Figure 7.4. Complementary effects of OX interventions. A: straight-line R2 on characterisation-grid doses within the 20–600 µM window. B: green signal at 600 µM divided by that at 50 µM, with the provisional twofold threshold shown. Both use the 3 h readout. C: timing CRLB relative to the intact model at 200 µM and 3 h, with independent 25% per-channel noise and N = 1. All variants are pre-equilibrated for 50 h. Values are from the repository CSV outputs; C uses a logarithmic axis.
Feedback preserves a more discriminating dose response

Removing TetR autoregulation reduced the OX dose-response range from 2.69-fold to 1.22-fold and reduced linearity R2 from 0.907 to 0.414. The high-dose response remained 12.16-fold above the zero-stress control. The circuit therefore still responded strongly, but its output changed little across the tested nonzero doses. This is consistent with saturation under this protocol.

Removing sensor feedback produced a similar loss of range (1.25-fold; R2 = 0.420). In contrast, setting adaptation-mediator decay to zero retained a 2.59-fold range and R2 = 0.918. The presence of feedback mattered more for these particular dose-response metrics than this change in adaptation depth; this is not a general parameter-robustness result.

Reporter maturation supports a different function

Matching the mean red maturation time to the green maturation time left the dose-response metrics almost unchanged (2.67-fold; R2 = 0.907), but raised the timing CRLB approximately 89-fold. This intervention therefore separated temporal information from dose-response shape. It equalises mean maturation times, not the complete one-step and two-step maturation dynamics.

Removing basal TIP production and removing the FRET correction changed the primary output by −11.7% and +12.0% respectively, against +207.5% for removing TetR autoregulation and +116.0% for removing sensor feedback. The two feedback loops therefore dominate, while promoter leakiness and the observation correction are tolerant at roughly the ten per cent level.

The ER response illustrates why these findings must remain module-specific: removing TetR autoregulation reduced linearity from 0.936 to 0.602, but retained a 20.29-fold dose range. The saturation pattern observed in OX did not reproduce in ER.

Connecting information limits to measurement

The Cramér–Rao analysis describes local information about dose and time in the two fluorescence channels. Its standard-deviation bounds are conditional on the forward model and noise assumptions. A large bound exposes a limitation; a small bound does not establish that a practical decoder achieves that precision.

Timing Cramér–Rao bound against number of cells for three shared-noise scenarios, showing the zero-shared curve continuing to fall while the 2% and 5% curves flatten towards a floor, with a 30-minute benchmark line.
Figure 7.5. Averaging cannot remove a shared measurement component. OX, 200 µM, event age 3 h, per-cell channel CV 25%. Curves use v(N) = 0.252/N + cshared2 independently in each channel. The dashed line is a 30-minute CRLB benchmark, not demonstrated decoder accuracy. Points are the stored population CSV results.

At 3 h, increasing the population to 100 cells reduced the timing bound from 3.04 h to 18.2 min when the shared noise component was zero. With a 2% shared component, it was 23.4 min; with 5%, it was 40.8 min. In the 5% scenario, the bound approached approximately 36.5 min even as cell number increased without limit.

This makes calibration a concrete measurement priority: increasing cell count alone cannot overcome the assumed shared error floor. The numerical thresholds are scenario-dependent, so the next step is to estimate channel noise and covariance from imaging controls before treating them as instrument specifications.

Information changes with the age of the event

In the 100-cell, zero-shared-noise OX scenario, the timing bound was 3.7 min at 1 h, 18.2 min at 3 h and 49.2 min at 4 h. The corresponding log-dose standard-deviation bounds were 0.200, 0.091 and 0.096. Thus, a single measurement does not provide the same information throughout the response.

These results motivate testing the decoder across event ages and doses rather than reporting one overall accuracy. They do not establish a validated memory window. Population averaging also assumes that the cells share the dose and event age being estimated; heterogeneous exposure histories require a different inference model.

Separating functional comparisons from support in data

Ablation asks what changes when a mechanism is altered. We separately compared the static sensing model (FINAL) and the adaptive sensing model (PULSE) to ask how alternative sensing descriptions affect the readout, and whether published observations support their dynamics.

No sensing model performs best on every metric

The downstream reporter and TIP–TetR modules are identical in the source snapshots. However, the OX sensing models differ in both structure and parameters. We therefore included a static-model control with the adaptive model's maximum TIP production rate (βmax = 118 nM h−1). This controls that production-rate difference, but does not match every sensing parameter.

Two panels comparing the static and adaptive oxidative sensing models: timing Cramér–Rao bound against event age, and the standard-deviation bound for log dose, including the production-matched static control.
Figure 7.6. Conditional information trade-offs between the OX sensing models. Both panels use 200 µM, N = 100, 25% per-cell channel CV and zero shared noise. A: timing CRLB. B: standard-deviation bound for log dose, retained in log units to avoid interpreting large values as percentage errors. The matched-production control changes βmax only. Data: stored B3 CSV.

At matched maximum production, the static model had a larger dose-response range at 3 h (4.69-fold versus 2.69-fold). The adaptive model had a lower timing bound at the sampled ages from 0.5 to 2 h, but the advantage was much smaller after this control: at 1 h, the comparison was 3.7 versus 5.0 min. By 3 h, the matched static model had the lower bound (15.5 versus 18.2 min).

This comparison identifies a trade-off rather than a universal winner. It supports evaluating candidate forward models against the intended dose and time range, while keeping model choice open to further biological evidence. Better local information under a model does not establish that the model describes the cell correctly.

What the available data can support

We fitted static and adaptive descriptions to seven digitised observations of Yap1 oxidation after 400 µM H2O2 exposure from Delaunay et al.1 This comparison concerns sensor activation, not fluorescence from the complete ICHNOS construct. The observations are distinct from the dose-calibration series, but had previously informed kinetic choices; they are not fully independent validation data.

Seven digitised Yap1 oxidation observations with the fitted static and adaptive sensing curves overlaid; the adaptive curve rises and then declines, leaving visible residuals at later times.
Figure 7.7. Published time-course observations and the fitted sensing descriptions. Points are the repository's window-densitometry values. Curves are reconstructed using the stored fit parameters and the repository prediction function. The adaptive fit captures the early rise and subsequent decline, but leaves visible residuals, particularly at later times. This is a fit to development data, not a held-out test.

The adaptive model reduced the residual sum of squares from 0.6973 to 0.1043. Nevertheless, ordinary AIC favoured the adaptive fit while AICc favoured the static fit (ΔAICc = 7.70 against the adaptive model). The conclusion is sensitive to the complexity penalty with this small dataset; a better fit alone does not settle model selection.

Parameter constraints were also uneven. The archived profile-likelihood plot shows a lower-side constraint on kon, a broad two-sided region for the combined parameter g = koff·kx, and weak constraint on dx over the scanned range. Separately, koff and kx cannot be recovered individually from the fitted activation observable in this formulation because only their product enters the rescaled model.

What this analysis contributes to ICHNOS

Together, the results explain why feedback and reporter maturation deserve separate experimental checks, identify measurement noise as a limit on inference, and make the static–adaptive trade-off explicit. They also define what remains to be tested: complete-circuit fluorescence dynamics, decoder performance on known exposures, imaging-derived noise assumptions and ER calibration.

The ablations establish mechanistic dependencies at the selected parameter sets. The most useful follow-up is to test whether these dependencies and information limits persist across plausible parameters and experimental measurements.

The regulatory and timer mechanisms use the modelling foundations described in815 and the preceding model sections. Full parameter provenance is documented in the repository.

Ablation definitions and simulation protocol

Each intervention changes a defined part of the integrated model. For the TetR-feedback intervention, promoter activity P is frozen only in the TetR-production reaction at its zero-stress reference value; the reporter regulation is retained. Sensor feedback is removed by setting koff = 0. The OX adaptation-depth intervention sets dx = 0. The maturation intervention sets m1 = m2 = 2m, equating mean red and green maturation times. Basal TIP production and the observation correction are tested separately by setting βbasal = 0 and E = 0, respectively.

Simulations pre-equilibrate the model for 50 h at zero stress before applying a constant dose. The primary comparison is at 3 h, aligned with the accumulated-reporter calibration context25. OX operating doses are 50, 100, 200, 300, 400 and 600 µM. The ER grid spans 500–6000 µM. The ER sensing parameters are provisional, so this range is not independently calibrated against measured DTT response in the way the oxidative grid is. The OX upper range is motivated by the reported high-dose signal loss in25, not a toxicity threshold established for ER.

A wider 14-point OX characterisation grid spans 5–5000 µM to describe the simulated response shape. Doses outside the operating range are numerical probes, not claims of biological usability. The code calculates linearity from characterisation-grid points inside 20–600 µM; the high/low fold range uses 600 and 50 µM. Pre-equilibration checks compare 20, 50 and 200 h, and assess the effect of a zero-state start.

Performance metrics and observation model

Dose-response steepness is described by a bounded four-parameter fit:

G(d) = b + (a − b) dn Kn + dn

The fitted n and its covariance-based standard error summarise simulated curve shape; they are not biological replicate uncertainty. A separate straight-line fit gives R2 within the operating window. This replaces an earlier logit-slope estimator that failed synthetic checks.

The signal checks use G(dhigh)/G(dlow) and G(dhigh)/G(0). At the provisional threshold θ = 2, a response passing both is labelled viable; a response passing only the zero-stress comparison is labelled saturated; a response failing both is labelled dead. These are operational model labels, not cell-viability measurements. Thresholds 1.5, 2 and 3 are tested; θ = 3 rejects even intact OX. Ratio spread is interpreted only with these signal checks.

For joint inference, y = (ln G, ln R), q = (t, ln d), J = ∂y/∂q and F = JTΣ−1J. The reported bounds are √((F−1)11) for time and √((F−1)22) for log dose, where the inverse is numerically defined. The dose derivative uses a central step of 0.05 in ln d; the time derivative uses the simulated trajectory. These are local bounds for the stipulated model and regular unbiased-estimation setting, not empirical errors or global identifiability tests.

The implementation takes Σ = diag(cG2, cR2), with baseline channel CV 0.25 and additional 0.10/0.40 scenarios. This is a CV-based log-space variance approximation: exact lognormal log variance would be ln(1 + CV2). Population scenarios use v(N) = ccell2/N + cshared2 independently per channel. Shared across cells does not mean correlated across channels in this calculation. Measured channel covariance, calibration uncertainty and model mismatch are not propagated here. The separate Fisher analysis in Section 7.3 uses a Poisson observation model; its numerical bounds are not directly interchangeable with these.

Structural comparisons and model selection methods

The functional comparison uses source snapshots with identical downstream modules and includes the OX βmax-matched static control. Other sensing differences remain, including the Hill exponent. ER comparisons are descriptive because multiple sensing properties differ and the production-rate control is a no-op.

The data-fitting comparison uses the window-densitometry series for Delaunay Figure 2B, with Kact = 208 µM and n = 2.75 fixed. The static fit estimates a constant activation level; the adaptive fit estimates kon, g and dx from a two-state ODE. Both use unweighted residual sums of squares and a constant-variance Gaussian error model. The AIC/AICc parameter counts include the fitted noise variance: k = 2 and 4 respectively.

AICc = nobs ln RSS nobs + 2k + 2k(k + 1) nobs − k − 1

up to a common constant.

The adaptive optimiser uses 32 seeded starts. Profile likelihood re-optimises the other parameters at each fixed parameter value on a 17-point grid. Additional-point projections assume unchanged residual behaviour; they do not guarantee a minimum sample size. Independent time courses are needed to test the model and its parameter constraints.

Numerical checks and reproducibility

The study builds model snapshots from pinned repository commits and records source hashes and solver versions in a manifest. Runners verify snapshot integrity before executing the analysis.

Checks examine downstream-model identity, pre-equilibration convergence, estimator behaviour on synthetic curves and whether intended parameter overrides change the model. Outputs retain their source-version identifiers.

The ablation protocol is documented independently of the sensitivity and physics-informed protocols. Numerical results are compared across workstreams only after accounting for differences in initialisation, dose grids, noise models and readout definitions.

7.3 Fisher information

Quantifying the information carried by fluorescence.

We used Fisher information to examine how precisely stress dose and time since onset could be inferred jointly from the two fluorescence channels. The analysis evaluates the information available in the intact circuit under a specified observation model.

Dose and time are treated as unknown simultaneously. This avoids assuming that the fluorescence ratio provides an independent clock or that dose is already known when timing precision is assessed.

The resulting Cramér–Rao bounds describe local limits for unbiased estimation under the stated assumptions. They do not represent experimentally measured precision or the achieved accuracy of the final software decoder.

The two channels are not separable: dose and elapsed time are confounded, with a correlation near −0.9. This is the most robust result of the analysis, reproduced to within 2% by the ablation study's independent implementation under matched conditions.

A narrow tilted ellipse labelled 95 percent joint region, correlation minus 0.93, drawn on axes of error in log dose against error in elapsed time, each in units of its own standard deviation. A dashed circle marks the region the same bound would give if the two were independent; the ellipse leans steeply across it from upper left to lower right.
Observation model and mathematical formulation

The observation model represents green and red measurements as independent Poisson photon counts with means determined by the integrated circuit. This describes photon shot noise; additional measurement and biological noise sources are not included in the baseline calculation.

The inferred parameter vector contains dose and time since stress onset, with dose uncertainty reported relative to the reference dose. The attainment test parameterises dose logarithmically, so its dose bound is relative by construction.

We calculate a joint 2 × 2 Fisher information matrix from the dependence of both channel means on both parameters. Its inverse provides the local covariance bound where the matrix is non-singular.

The off-diagonal covariance describes coupling between dose and time estimation errors. Strong correlation indicates that changes in the two quantities produce similar effects on the observations, making them difficult to distinguish locally.

Absolute uncertainty depends on the assumed photon conversion and forward-model parameters. These dependencies are retained explicitly when interpreting the bounds.

Each channel k ∈ {green, red} is modelled as an independent Poisson count with mean λk(θ) given by the merged model, where θ = (dose, time since onset):

yk ~ Poisson(λk(θ))

For Poisson observations the Fisher information is exact and sums over the independent channels:

F(θ) = Σk 1λk ∇λk ∇λkT

giving the 2 × 2 matrix

F11 = Σk (∂λk/∂dose)2 λk

F12 = F21 = Σk (∂λk/∂dose)(∂λk/∂t) λk

F22 = Σk (∂λk/∂t)2 λk

The Cramér–Rao bound is the inverse, Cov(θ̂) ⪰ F−1, from which we read the marginal bounds and their coupling:

σ2dose ≥ [F−1]11,    σ2t ≥ [F−1]22

corr(dose, t) = [F−1]12 √([F−1]11 [F−1]22)

Two scalings follow directly and are used throughout. Pooling N cells with the same dose, elapsed time and modelled response gives FN = N·F, so every bound falls as 1/√N. And because F is linear in λ, and λ is the model fluorescence multiplied by an unmeasured photon-conversion constant, every absolute bound scales as 1/√(photons per unit). This is why absolute precisions are reported as formulas rather than values.

Dose derivatives are centred finite differences from three runs at neighbouring doses; time derivatives are taken on the centre run. Where the matrix is near-singular (determinant ≤ 10−30) no inversion is performed and the bound is left undefined, rather than reporting a spuriously small variance from an unstable inverse. A detection mask is applied before any readout time is called optimal, so a sharp CRLB minimum at a point where the signal is not yet detectable cannot be reported as an operating point.

Defining the simulation and measurement conditions

The analysis reads fluorescence observables from the existing merged SBML model rather than implementing a separate circuit. Before stress application, the model is pre-equilibrated at zero stress to establish its baseline reporter pools.

A common, explicit photon-conversion scale is used across branches. Detectability is assessed from the signal increase above each channel's own baseline, preventing pre-existing fluorescence from being mistaken for a detectable stress response.

We examined information across observation times and pooled cell counts. These assessments identify informative operating conditions within the model, while retaining the need for experimental calibration of brightness and detection thresholds.

The informative readout window is early, well under three hours. This result changed the experimental plan: the H2O2 sampling times were chosen from it.

Initialisation, parameter packages and measurement settings

Pre-equilibration runs for 50 hours at zero stress and zero effective-input decay. Stress and the selected post-onset dynamics are applied afterwards. The pre-equilibration duration was checked against a longer reference simulation.

Fitted kinetic settings are applied as named parameter packages. This prevents a fitted input-decay rate from being combined silently with unrelated kinetic values. These packages are distinguished from the PI scenarios in Section 7.1, which follow their own declared construction.

Photon conversion is held fixed rather than normalised to the peak of each simulated trajectory. Peak-dependent or branch-specific conversion would change the assumed measurement noise when the protocol or sensing branch changes.

Detection thresholds are applied to channel increases above baseline. The conversion scale and thresholds remain provisional until independently calibrated.

Pooling is modelled as the sum of independent observations from cells sharing the same dose, elapsed time and modelled response. Under this assumption, information increases with cell count. This scaling does not account for heterogeneous cellular responses or correlated errors.

Settings for the reported runs, as recorded in each run's provenance header:

Parameter package
None applied; the model runs with the values committed in the SBML, so no fitted override is mixed into the reported numbers. Named packages exist for comparison runs and are applied whole, never parameter by parameter.
Reference dose
208 µM for the oxidative branch, 2,200 µM for the ER branch, each at or near the half-activation point of its own sensing module.
Dose derivative
Centred finite difference at ±2% of the reference dose.
Simulation window
24 h at 2,000 points, after 50 h of pre-equilibration at zero stress over 200 points.
Photon conversion
Fixed at 2.33642 photons per model unit. Provisional, awaiting a Photon Transfer Curve measurement; every absolute bound scales as the inverse square root of this constant.
Detection
Threshold of 10 photons, enforced on both channels, applied to the increase above each channel's own baseline rather than to the absolute level.
Saturation
255, the 8-bit per-channel ceiling of the images analysed.

Checking the calculation and bound attainment

Four panels. Three scatter plots of dose error against timing error, each normalised to the bound, for one, ten and one hundred pooled cells; the single-cell cloud is compressed and partly pinned at the dose search limit, while the hundred-cell cloud fills the ninety-five percent ellipse. The fourth panel plots empirical standard deviation divided by the bound against pooled cell count for dose and timing, both converging to one as cells are pooled.
Figure 7.8. Empirical estimator performance against the Cramér–Rao bound, oxidative branch at 208 µM, one hour after onset, 600 synthetic measurements per pooled cell count under a fixed seed. The ratio to the bound falls from 4.58 at a single cell toward 1 as cells are pooled; the single-cell estimator is also biased by about +30 minutes on a 60-minute truth.

We evaluated both the numerical Fisher calculation and the conditions under which its bound approximates estimator performance.

Two differentiation routes provided a consistency check on the information matrix. A separate comparison with the ablation implementation examined agreement under matched conditions despite different noise models.

We also generated synthetic measurements at known dose and time, estimated both quantities by maximum likelihood and compared the empirical errors with the theoretical bound. This is a controlled attainment test, distinct from validation of the deployed software decoder.

The two differentiation routes agree to 0.64%. The attainment test shows the bound is not reachable from a single cell, where the estimator is biased and misses the bound several-fold; timing approaches it from about ten pooled cells and dose only from several hundred. The bound therefore describes a population measurement, not a single-cell decoder.

Numerical verification and synthetic attainment tests

The first differentiation route uses simulated ODE outputs; the second uses an interpolated dose–time surface. Their Fisher matrices are compared at a common operating point, with an acceptance criterion preventing interpolation error from being interpreted as estimator behaviour.

The Poisson calculation is also compared with the independently implemented lognormal analysis used in the ablation study. Comparisons specify the trajectory, operating point, parameterisation and noise assumptions.

For the attainment test, synthetic Poisson measurements are generated at a known dose and a one-hour observation time. Maximum-likelihood estimation is repeated across pooled cell counts using a fixed random seed and optimization.

Assessment includes empirical standard deviations relative to the CRLB, estimation bias, dose–time error correlation and the fraction of estimates reaching the search boundaries. Compressed scatter from a biased or boundary-constrained estimator is not interpreted as exceeding the information bound.

The two differentiation routes are compared at a common operating point and the test aborts rather than reporting a ratio if they disagree by more than 5%. The attainment test runs 600 synthetic measurements at each pooled cell count, from a single cell up to one thousand, at a known dose and a one-hour observation time, under a fixed random seed with multi-start optimization. The maximum-likelihood search is bounded to a factor of four around the reference dose. That range acts as an implicit prior, as a real decoder also knows roughly what dose range is physiological, and it does substantial work in the single-cell result: a wider range would reduce the pile-up of estimates at the boundary and widen the scatter. It is stated here because the single-cell numbers are not interpretable without it.

Testing dependence on uncertain kinetics

We examined whether information-based conclusions remain stable when poorly constrained sensor kinetics change. The robustness analysis distinguishes parameter combinations compatible with the calibration from a control perturbation that changes the constrained combination.

This allows the stability of dose–time coupling and readout timing to be assessed separately from absolute precision. Measurement calibration and kinetic uncertainty are treated as distinct contributions to the interpretation of the bounds.

The correlation survives: it moves by about 6% across a 370-fold change in a parameter the data cannot constrain. The readout window survives qualitatively but not to the minute. Absolute timing precision does not survive, moving 2.3-fold along the unconstrained direction, which is why this section reports no absolute σt.

Kinetic robustness, assumptions and reproducibility

The oxidative robustness test varies buffer-loss and feedback parameters together along a family that preserves a calibration-constrained combination, while holding the other specified parameters fixed. A control varies buffer loss with feedback held fixed.

For each setting, we evaluate dose–time correlation, the informative readout point and marginal uncertainty bounds. The test examines the selected uncertainty direction; it is not a complete propagation of every uncertain parameter.

The baseline observation model assumes independent shot noise and corrected channel crosstalk. Camera read noise, autofluorescence and biological heterogeneity are not explicitly represented. Accordingly, the bounds describe an idealised measurement model.

Every run records the parameter package, pre-equilibration duration, photon scale and detection convention. Legacy configurations are identified explicitly, and the circuit is imported from the modelling repository to preserve provenance.

The ridge is the one-parameter family dx → a·dx, koff → a·koff, which leaves the combination

r = kon·dx koff·kx

unchanged and is therefore invisible to the quantifications that determined r. The control sweeps dx over the same range with koff held fixed, which changes r and moves in a direction the data do constrain, so a null result would indicate an insensitive test rather than a robust model. Both sweeps run dx from 0.03 to 11.11, a 370-fold range. The family is not an invention of the test: scaling the committed pair (dx = 0.5, koff = 160) to the ends of that range gives koff = 9.6 and 3,555, against quoted values of roughly 5.3 and 1,900 at the corresponding densitometry quantifications, the same order at both ends.

8. Software tool

8.1 Connecting the model to microscopy measurements

We developed ICHNOS-tool to connect microscopy measurements with the integrated model and its central question: can a fluorescent snapshot reveal how much stress a culture experienced and how long ago? The tandem reporter provides the proposed cellular memory: its fluorescence depends on the history of reporter production and maturation. The tool tests when that history contains enough information to recover dose and elapsed time.

The workflow converts images into per-cell fluorescence measurements, compares experimental responses with model predictions and applies decoders with explicit uncertainty and validation records. The accompanying local application, ichnos_vail, makes these workflows accessible through a graphical interface.

The model–measurement loop: the ICHNOS model in SBML on one side and the ICHNOS-tool image pipeline on the other, meeting on a shared fold-change scale that feeds a test-and-decode stage, which loops back into the model.
Figure 8.1. The model–measurement loop. Model predictions and image-derived measurements meet on a shared fold-change scale, and evaluation feeds back into model development and experimental design. The shared-scale comparison avoids a concentration-to-intensity conversion; model-based decoding still requires the calibration described below.

In a nutshell

Inputs
Bright-field, green and red TIFF frames; a manifest recording exposure, objective, session and sample identity. Reference experiments also require known dose and elapsed time.
Required references
A same-day 0 µM culture for paired comparisons; non-transfected controls for autofluorescence and reporter-positive thresholds. Model-based decoding requires its own explicit calibration and noise references.
Outputs
Per-cell measurements and QC; field and sample summaries; induction and model-comparison results; dose-class and time-window probabilities with separate verdicts.

8.2 From images to fluorescence measurements

Cells are segmented on bright-field images and the masks are aligned to the fluorescence frames. This avoids selecting cells because they are bright in the reporter channel. Against 212 manually marked cells on seven crops, Cellpose achieved recall 0.91 and precision 0.90, compared with 0.44 and 0.31 for the initial fluorescence-based masks. These scores assess cell detection and separation, rather than the accuracy of cell outlines.

The pipeline extracts green and red fluorescence, subtracts local background and records measurement quality. Intensities are normalised by exposure duration; non-transfected cultures provide the autofluorescence baseline. Same-day unstressed cultures anchor the experimental comparisons, while fields from one culture remain grouped rather than counted as independent biological replicates.

Image processing and measurement assumptions

Acquisition logs link each image to its condition and elapsed time. Bright-field frames were matched for 288 of 294 fields; six without a matching frame were excluded. Saturation and image-edge checks determine cell retention. Focus is recorded but was not enforced for this dataset. Reporter-positive cells exceed the 90th percentile of the non-transfected reference in both fluorescence channels.

For the October analysis, bleed-through was set to an indicative 0.05 because single-colour controls were unavailable. Red-channel exposure linearity remains an assumption, and no flat-field correction was applied. These conditions accompany the results and must be considered when transferring the workflow to another imaging setup.

8.3 Comparing observations with model predictions

Model concentrations and camera intensities use different units. We compared fold changes relative to the same day’s unstressed culture, avoiding an uncalibrated conversion from concentration to image intensity. Simulations used the experimental doses and imaging times, with the existing model parameters retained rather than refitted to these measurements.

The default model overpredicted the H2O2 response by approximately 1.7–5-fold at doses of at least 75 µM. Assumed stress clearance improved agreement, identifying exposure history as a priority for measurement. At the tested DTT doses, both model and data showed little response; agreement near baseline does not validate the model’s response at higher doses.

Model and measurement comparison

Within-day induction tests report effect sizes, 95% bootstrap intervals, minimum detectable effects and multiple-testing-adjusted q-values. Model comparison uses fold changes in reporter-positive cells. For H2O2, predictions fell within measured 95% intervals in 0/18 comparisons under constant stress, 5/18 with clearance at 1 h−1 and 11/18 at 3 h−1. These rates are scenarios, not experimentally estimated clearance rates. DTT predictions fell within the intervals in 16/20 comparisons, largely because both responses remained near baseline.

8.4 Model-based and empirical decoding

A decoder works backwards from fluorescence to candidate stress histories. We implemented two families because recovery from an idealised model and recovery from a new experimental culture require different evidence.

Model-based decoders simulate candidate doses and elapsed times and compare their predicted fluorescence with an observation. The two-observable snapshot decoder combines red/green with reference-normalised green. Their joint response can distinguish histories that remain compatible with the ratio alone. A conditional grid posterior assigns probabilities to the candidate dose–time pairs and returns a credible set: a group of plausible histories under the chosen model, calibration and noise assumptions.

Empirical decoders learn directly from labelled reference images. The default paired dose decoder compares each field with the same day’s 0 µM culture; an absolute decoder is available when no paired control exists. A separate timer decoder uses red/green and green fluorescence to classify elapsed time into windows. The default windows are 0–2, 2–4, 4–6 and 6–8 hours.

Decoder Question it answers Current use
Dose at known times Which tested dose is compatible with the measured ratio? A separate checked interpolation supports intermediate doses. Model-based research workflow
Joint dose and time Which dose–time pairs fit observations with known relative spacing? Model-based research workflow
Two-observable snapshot and posterior Which histories fit one ratio-plus-green observation, and how uncertain is the result? Synthetic verification and experiment design
Empirical dose and time windows What can a labelled reference experiment predict for a new field? ichnos_vail and the field decoder, with validation verdicts
How the decoders are constructed

The model-based snapshot and posterior operate on a discrete dose–time grid. A unique grid match does not establish continuous identifiability. Dose interpolation is a separate method and does not make every decoder continuous.

Empirical dose features are green intensity, red intensity and the reporter-positive fraction, with the same-day control subtracted in paired mode. Time features are log(red/green) and log(green) in reporter-positive cells. The ratio reduces dependence on reporter abundance; green retains amplitude information. Class probabilities use a Gaussian likelihood and a uniform class prior, with between-day and within-day variation represented separately. Multiple fields from a sample are averaged rather than treated as independent cultures.

8.5 Testing dose and time recovery in silico

We first asked whether the model’s fluorescence readout could retain enough information to recover a stress history. In the dense oxidative benchmark, adding reference-normalised green to the ratio reduced the reported dose error from 257 to 111 µM and time error from 1.18 to 0.84 h. The 95% credible set contained the true dose–time pair in 96% of matched-model trials, while its average size fell from 30% to 10% of the candidate grid.

The same benchmark also tested an incorrect exposure assumption. When stress cleared at 0.2 h−1 but decoding assumed constant exposure, truth inclusion for ratio plus green fell to 50%, even though the credible set narrowed to 6% of the grid. More precise-looking predictions can therefore be wrong when exposure history is misspecified.

Synthetic benchmark design and scope

The benchmark used 3,366 synthetic summary draws across two exposure scenarios: a 17 × 33 grid spanning 0–800 µM and 0–8 h, with three draws per node per scenario. Noise covariance was fitted using 36 separate synthetic culture labels. The two methods received the same observation and prior within each comparison.

Noise was generated in observable space, so this benchmark does not test segmentation or realistic image noise. A separate noise-free image-to-decoder workflow checks the processing chain. The dense benchmark uses on-grid truths and fixed calibration; model-parameter, calibration and covariance-estimation uncertainty are not propagated. Equal sampling at grid nodes also means aggregate truth inclusion is not prior-predictive coverage. These results establish conditional computational performance.

8.6 Testing the decoders on experimental images

To test transfer to a new imaging day, we trained the empirical decoders on the remaining days and evaluated the held-out day. This leave-one-day-out design keeps fields from the same day together. The reference dataset contained three H2O2 days and two DTT days, with one culture per dose and day.

Six heatmaps of mean posterior probability per true dose on held-out days, for DTT and hydrogen peroxide with the absolute, paired and model-guided decoders. Most rows are nearly uniform; the hydrogen peroxide model-guided decoder concentrates probability at the lowest doses.
Figure 8.2. Mean posterior per true dose on held-out days, reproduced unchanged from Figure 4 of ICHNOS_model_software. Outlined cells mark the true doses. Nearly uniform rows indicate little dose information; the H2O2 model-guided decoder concentrates probability at low doses. The numerical summary below reports day-averaged dose accuracy.

Paired dose accuracy was 0.10 against chance 0.20 for H2O2, and 0.17 against 0.17 for DTT. Time-window accuracy was 0.19 against 0.31 and 0.20 against 0.28, respectively. Information gain was negative in all four cases. These data therefore do not establish reliable dose or elapsed-time inference for a new day.

The red/green ratio showed no consistent temporal trend, and no stress-induced burst of reporter synthesis was detected. This dataset consequently does not establish a readable timer under the tested conditions. Basal expression and day-dependent transformation remain alternative explanations that the available measurements cannot separate.

This distinction defines the scope of our cellular-memory claim. The model and synthetic recovery tests show how fluorescence can encode dose and elapsed time under specified conditions. The experimental analysis tests whether that information is accessible in the measured cultures. Further measurements under informative induction conditions will help extend the evaluation of biological memory readout.

Experimental evaluation details

Performance is assessed through accuracy, information gain, posterior entropy and 80% credible-set inclusion. Time windows absent from the training days are counted as unscorable: 42 H2O2 fields were scored and 5 unscorable; 66 DTT fields were scored and 4 unscorable. Sparse independent days limit estimation of between-day variation. The model-guided evaluation also failed to generalise: for H2O2 it favoured low doses with high confidence. Model-based inference is therefore not offered for real images in the released field-decoding interface.

8.7 Returning an estimate only when supported

Dose and time have separate verdicts. Before reporting either, the tool checks cell availability, required references, similarity to the reference data, posterior informativeness and the decoder’s held-out-day record. Otherwise, it reports a specific outcome such as no dose information, no time information, unlike reference or not validated.

Decision criteria

An informative empirical posterior has entropy below 90% of the prior’s entropy. Reference compatibility is checked with a chi-square distance threshold at the 99th percentile. A positive held-out information gain is required before an estimate is accepted; a high posterior probability alone is insufficient. The time workflow additionally identifies unstressed controls, inadequate reporter-positive cell counts and references that cannot train a time decoder. These rules are implemented decision criteria, not a guarantee of accuracy on every future sample.

8.8 Making the workflow accessible and reproducible

The ichnos_vail application exposes the same scripts used for image processing, experiment analysis and decoding. Users can check manifests, process images in resumable batches and review dose and time probabilities alongside their verdicts and validation records. Each page displays the command it executes.

Automated tests check model execution, image processing, statistical analysis, decoder behaviour and application integration. The documented release check recorded 740 passing tests. Synthetic cases test recovery when a signal exists and refusal when it does not; measurement quality and experimental generalisation are assessed separately using manual annotations and held-out days.

Implementation and reproducibility

Run manifests record configuration, code version and input/output checksums. Existing results are protected from overwrite, and run logs retain both completed and failed steps. The application runs locally and delegates calculations to the underlying scripts. The released reference cell table supports rerunning the experimental analysis without repeating image segmentation. Full installation instructions, file contracts, calibration requirements and measurement limitations are provided in the documentation.

ICHNOS-tool makes the cellular-memory question testable: it connects the predicted dose–time response to measurable fluorescence, quantifies recovery under controlled assumptions and identifies when experimental observations cannot yet support an estimate.

For full user and technical documentation, including installation, input formats, workflow instructions and interpretation of outputs, see the Software documentation in our Contributions page. The source code is available in the ICHNOS-tool repository.

9. Wet lab integration

How the model and the experiments shaped each other.

The dry lab and the wet lab worked from a shared plan in which each side set requirements for the other. Before any strain was built, the modeling had fixed the circuit architecture, the quantity to be measured and the window in which to measure it. In return, the wet lab supplied what the model could not derive: the promoter architecture of the finished constructs, the properties of the instrument that was available, and later the images, acquisition records and a first RT-qPCR attempt against which the model could be tested. This section sets out what passed in each direction, which model quantity each measurement corresponds to, and what the comparison showed.

In brief

Design
Negative autoregulation and the FRET-corrected sfGFP dose readout were fixed in silico before the strains were built, and the early reading window before the dose-response runs.
Two-way specification
The wet lab’s sequence check of the finished constructs showed that TetR and the reporter share a galactose-dependent promoter, and a galactose step entered the protocol before the first dose-response run. The available instrument defined the readout as per-cell microscopy with bright-field segmentation, and its 8-bit depth fixed the saturation ceiling used in the information analysis.
An independent test
The model’s parameters were fixed before the first image existed and were not adjusted afterwards. The held-out day split of the decoders was declared before any real data were decoded.
Outcome
The measurement chain, from slide to per-cell values compared with the model, worked end to end. On one of the three H2O2 imaging days the red signal rose with dose, which is the lead to confirm next. The comparison points to two quantities that can be measured directly, the exposure history of the cultures and the calibration between model and camera units, and both lead the next round.

Design

Before the experiments

During the experiments

Analysis and comparison

Dry lab
Wet lab

Click a card to flip it

Figure 9.1. What passed between the dry lab and the wet lab at each stage, from circuit design to image analysis.

9.1 What the modeling fixed before the build

Architecture

The negative-autoregulation topology, in which TIP inactivates TetR and TetR represses its own promoter, was selected in silico to flatten the steep response of native stress promoters. It was tested against a matched comparison circuit with the autoregulation removed. In the frozen oxidative configuration, restoring autoregulation raised the fold change from 1.756 to 4.244 and the linear R2 from 0.370 to 0.947 (Section 5.3). Running this comparison in silico allowed the autoregulated design to be chosen before any strain was built. The open-loop circuit was not built, so the comparison exists in silico alone.

Readout

A steady-state analysis of the tandem timer showed that the red-to-green ratio follows reporter age and not promoter activity. The dose readout was therefore defined as FRET-corrected sfGFP intensity, and the ratio was kept as the timing signal. At the bench this became a concrete acquisition requirement: two fluorescence channels and a bright-field frame for every field.

Binding affinity

Sensitivity analysis showed that the amplitude of the response depends strongly on the TIP–TetR dissociation constant, so the design value of 0.25 nM was examined against structural information. An earlier docking-based estimate of about 62 nM, which reduced the modeled fold change to about 1.1 in the model as it stood then, was superseded when the analysis was repeated on the experimental TIP–TetR structure (PDB 2NS8). That gave 3.675 and 8.428 nM, from two interfaces of the same structure. These are computed estimates, not measurements. The model’s own criterion, an observed-green fold change of at least 1.5, sets upper limits of 30.2 nM for the oxidative variant and 5.74 nM for the ER variant, so both estimates lie inside the oxidative limit and the lower one inside the ER limit. A direct binding measurement is the single measurement that would most reduce the remaining uncertainty, and it heads the list in Section 9.6.

Sensor choice

The wet lab chose each sensing promoter by asking what regulates it, and set aside pTRX2 and pPDI1 largely because both sit inside the loop that clears the stressor. The architecture added a second requirement: because the TIP–TetR stage loses gain, the sensing stage has to give low basal output and high sensitivity. pSynOS4(alt1) was adopted on that basis, and the oxidative TIP production range used in the model (23.6-fold) is the ratio published for the same promoter variant. The ER range (32.5-fold) was carried over from an earlier version of the model and is listed for derivation and for checking against pKAR2 in the next round.

Measurement design

The RT-qPCR panel was built to return the model’s internal quantities rather than generic expression data. GB1, co-transcribed with the 51 bp TIP sequence, stands in for TIP production because the peptide itself is too short to amplify; sfGFP follows the reporter and TetR the repressor; UBC6 was taken as the reference from a published stability screen. The colony PCR across the left junction was designed to show that the left end of the cassette sits at the HO locus.

A fact from the bench: the galactose gate

On 2 October, while the dose-response protocol was being finalized, the wet lab went back to the construct sequences to confirm which promoter drives which gene. TetR and the reporter both sit behind pGAL1-D12, which galactose switches on and glucose holds off, so the routine glucose medium would have left both silent. A galactose step of 3 hours was added before every stressor, and it was in place before the first dose-response run. The model has no galactose state: promoter activity depends on free TetR alone, and the information analysis starts from 50 h of zero-stress equilibration. Every dose is compared with the same-day 0 µM culture, which went through the same galactose step, and a galactose time course is on the next-round list so that the starting state can be added to the model.

A fact from the bench: the instrument

There was no flow cytometer. The Fisher analysis assumes single-cell signals, which is why the dry lab had asked for cytometry, so the readout became widefield microscopy with per-cell segmentation, and the analysis was built to match the instrument. Cells are segmented on bright-field frames and not on the channel being measured, and the segmentation was scored against 212 hand-marked cells with the tuning and test split declared in advance. Cellpose reached recall 0.91 and precision 0.90, against at most 0.71 and 0.67 for the tuned classical methods tested. Two properties of the setup enter the analyses directly: single-cell values obtained this way do not have the noise properties of cytometry, so the information bounds are read as specific to this instrument, and the 8-bit images fix the saturation ceiling of 255 used in that analysis.

9.2 Dose ranges, reading times and acquisition

The dry lab sent written guidance for the dose-response design and, separately, an acquisition sheet for the microscope. The wet lab adapted both to the equipment and the time available. Table 9.1 sets what was asked against what was run, with a note on each choice. Concentrations are final concentrations in the culture, in µM, and times are minutes from dosing.

Aspect Dry lab specification Run by the wet lab Note
Readout Single-cell data; flow cytometry preferred Widefield epifluorescence on an Olympus CKX41 with a QImaging MicroPublisher 3.3 RTV color camera, 24-bit color TIFF (8 bits per channel); cells segmented from bright-field Instrument availability. The analysis was rebuilt around the available readout, with segmentation scored against hand-marked cells
Doses, H2O2 0 to 800 µM (0, 100, 300, 400, 500, 800) 0, 20, 75, 300, 600 µM The top dose was kept below the requested 800 µM out of concern for toxicity to the cells, and lower doses were included to test the sensitivity of the system
Doses, DTT 0 to 5,000 µM (0, 660, 1,500, 2,200, 3,300, 5,000) 0, 100, 250, 500, 1,000, 2,000 µM Doses above 2,000 µM were not used out of concern for toxicity to the cells, and lower doses were included to test the sensitivity of the system. The top dose reaches the lower part of the modeled ER range (see below)
Doses, CuSO4 None specified (the model has no copper module) 0, 10, 25, 50, 100 µM Wet lab addition from published characterizations of the CUP1 promoter, as a positive control for the downstream cascade
Number of doses 6 to 8 5 for H2O2 and CuSO4, 6 for DTT, each including the 0 dose Each dose has its own slide at every time point
Replication 3 independent cultures per dose One culture per dose per run; one or two fields per sample on 5, 6 and 10 Oct and three neighboring fields (R1 to R3) per sample on 7 to 9 Oct. Independent replication across days (three H2O2 days, two DTT days, one CuSO4 day) The three fields of a sample are neighboring views of one slide and not independent samples, so days are the unit of replication and the analyses never pool days
Reading times, H2O2 Several per run; most informative window about 46 to 75 min 5 Oct: five time points, 51 to 221 min; 6 Oct: two, 357 to 430 min; 7 Oct: four, 55 to 457 min Two of the three days start at or near the predicted window (first imaging block at 51 to 78 min on 5 Oct and 55 to 70 min on 7 Oct); 6 Oct covers the late window
Reading times, DTT Three per run 6 Oct: six time points, 17 to 395 min; 7 Oct: three, 56 to 319 min More time points than the three requested on 6 Oct
Background Unmodified strain under the same stressors Unmodified CEN.PK2-1C through every stressor at the same doses, in galactose medium with histidine (H2O2 on 8 Oct, DTT on 9 Oct, CuSO4 on 16 Oct) Required by the analysis: yeast fluoresces on its own and stress can change that
Camera settings Offset 10 to 50; brightness-stretching macro off; saturation warning on; 40× objective with the correction collar set Gain 3, gamma 1, 24-bit capture and offset 10 and 50 in all sessions; exposure of the red and green channels set per sample and the same for both channels; bright-field exposure fixed Shared instrument. The settings are recorded in the acquisition log, and the tool expresses intensity per unit of exposure time
Records Daily sheet (lamp time and setting, objective, collar, container, time of dosing, offset); per image the dose, time, file name, exposure and gain; original TIFFs kept Image manifest for the tool: dose, time from dosing to imaging, exposure per channel, objective. Where camera clock, folder names and log disagree, the log is authoritative The log records for each image the dose, the capture time of each channel and the exposure; this is what made the logged-time analysis possible
Extra captures Medium without cells; a strain without fluorescent proteins; 10 to 20 consecutive shots of one field Medium without cells imaged on 5 and 8 Oct; unmodified strain captured through every stressor; the consecutive-shot and photon transfer series are planned for the next round The photon scale in the information analysis is therefore stated as provisional

Table 9.1. Dose-response design: requested by the dry lab and run by the wet lab.

Times in this section are minutes from dosing to the capture of the red-channel image of each field, taken from the acquisition log. The slides of each time point were prepared first and imaged in one visit afterwards, so the imaging times run later than the slide times.

Dose ladders and the modeled sensors. The oxidative ladder spans the activation curve of the model, from almost no activation at 20 µM to near saturation at 600 µM. The DTT ladder reaches 2,000 µM, which is in the lower part of the ER range: the model’s ER reference dose is 2,200 µM, the frozen parameters place half-activation at about 2,345 µM, and the alternative fit places it at about 930 µM. Against the frozen parameters the series therefore samples the rising foot of the curve and not its plateau. The ladders are set against the modeled activation in the box below.

Dose ladders against the modeled sensor activation

Activation is the Hill term of each sensor, H(S) = Sn / (Kn + Sn), before feedback and adaptation act. The activation state that drives TIP production also depends on feedback and adaptation, which are not included here.

Sensor and parameters Dose run (µM) Activation (% of maximum)
Oxidative, Kact 208 µM, n 2.75 20 / 75 / 300 / 600 0.2 / 5.7 / 73 / 95
ER frozen, Kact 2,345 µM, n 3.97 100 / 250 / 500 / 1,000 / 2,000 < 0.01 / 0.01 / 0.2 / 3.3 / 35
ER alternative fit (Section 7.1), Kact 929.5 µM, n 4 100 / 250 / 500 / 1,000 / 2,000 0.01 / 0.5 / 7.7 / 57 / 96
Either ER fit, at the doses planned for the next round 2,200 / 3,300 / 5,000 Frozen 44 / 80 / 95; alternative 97 / 99 / 100

The two ER parameter sets predict very different activation at 500 to 2,000 µM, a range the DTT series covers, so this series is the data set that could separate them once a reporter response is resolved.

The early reading window

The information analysis located the most informative H2O2 reading at roughly 46 to 75 min after onset, where the timing bound has its interior minimum, and the dry lab pointed to it when asking for several time points per run, since the oxidative response cannot be fitted reliably from one or two. The analyses work from the logged imaging times, and on those times the first imaging block of 5 October fell at 51 to 78 min and that of 7 October at 55 to 70 min, at or near the predicted window on two independent days. The 6 October run was read at 357 to 430 min, so the data set covers both the predicted early window and a late comparison. A denser series across the window, which would let the early peak be fitted and not only sampled, is in Section 9.6.

9.3 What was exchanged during the experiments

Images and records

After each session the images, the dose and time labels and the acquisition record went to the dry lab. The microscope is shared and the imaging was done by an operator from a neighboring laboratory, so the camera settings were kept constant across sessions and recorded in the acquisition log: gain 3, gamma 1, 24-bit color capture and offset 10 and 50, with only the exposure of the red and green channels changing from sample to sample. The dry lab reviewed sample images and sent back three acquisition requests: raise the black level so that the dark background is not cut to zero, turn on the saturation warning because the images are saved at 8 bits per channel, and turn off the brightness-stretching macro. These are the camera-setting requests in Table 9.1. For every image the log records the dose, the capture time of the red, green and bright-field frames and the exposure. The tool expresses intensities per unit of exposure time and compares every dose with the 0 µM culture of the same day.

Early warnings

The acquisition sheet named one observation for the wet lab to report to the dry lab at once: a 0 µM sample that already shows a strong signal would point to a galactose step too short for TetR to accumulate. A 0 µM culture was imaged on every imaging day, so this check could be made on each day’s images.

Background reference

The dry lab asked for the unmodified strain because yeast fluoresces on its own and stress can change that. The wet lab ran it through every stressor at the same doses, in the same galactose medium with histidine added. The tool subtracts this baseline per stressor and uses it to set the reporter-positive threshold, so every per-cell result in Section 9.5 depends on it.

What the analysis received. The manifest listed each field with its dose, its time since the stressor and its exposure: 294 fields from seven imaging runs, of which 288 were matched to a bright-field frame. Each imaging day began with a fresh culture started from colonies, so days and not fields are the unit of replication, and the tool never pools days. The runs are listed below.

Imaging runs supplied to the analysis
Notebook Date Strain Stressor and final doses (µM) Imaging times after dosing (min)
Day 95 OctpSynOS4(alt1)H2O2 0, 20, 75, 300, 60051 to 221 (5 time points)
Day 106 OctpSynOS4(alt1)H2O2, same doses357 to 430 (2 time points)
Day 106 OctpKAR2DTT 0, 100, 250, 500, 1,000, 2,00017 to 395 (6 time points)
Day 117 OctpSynOS4(alt1)H2O2, same doses55 to 457 (4 time points)
Day 117 OctpKAR2DTT, same doses56 to 319 (3 time points)
Day 128 OctUnmodifiedH2O2, same doses13 to 153 (3 time points)
Day 129 OctUnmodifiedDTT, same doses26 to 303 (4 time points)
Day 1310 OctpCUP1CuSO4 0, 10, 25, 50, 10010 to 258 (5 time points)
Day 1616 OctUnmodifiedCuSO4, same dosesAbout 0 to 240, hourly (5 time points; nominal, capture times not in the log)

The analyses cover the two modeled stressors, H2O2 and DTT. The pCUP1 strain was imaged as a positive control for the downstream cascade. It has no module in the model yet, and adding one is a next-round item (Section 9.6) that would turn these images into a sensor-independent test of TIP, TetR and the reporter.

9.4 Where the model meets the data

Table 9.2 pairs each element of the model and the tool with the wet-lab measurement that bears on it, and states what that measurement establishes and what it leaves open. Chapter 4 (transferability to E. coli) has no wet-lab counterpart, because the experiments were carried out in S. cerevisiae only.

Model or tool element Prediction or requirement Wet-lab data Status
Cassette at the HO locus (5 or 6 fragments, shared downstream part) Single-copy integration; downstream part identical in the three strains His+ colonies for all three strains with a clear no-DNA control; reporter-positive cells detected by imaging Presence supported by selection and imaging; the left-junction PCR needs a more effective lysis step before the locus itself is confirmed
Oxidative sensor (Kact 208 µM, n 2.75) Hill activation of 0.2, 5.7, 73 and 95% at 20, 75, 300 and 600 µM H2O2 ladder 0, 20, 75, 300, 600 µM on three imaging days Doses span the modeled curve; sensor activity itself not yet measured
ER sensor (frozen Kact 2,345 µM, n 3.97; alternative fit 929.5 µM, n 4) Frozen: 0.2, 3.3 and 35% at 500, 1,000 and 2,000 µM. Alternative: 8, 57 and 96% DTT ladder 100 to 2,000 µM on two imaging days; no DTT response detected Ladder reaches the lower part of the ER range; the two fits could not be separated
TIP production range (23.6-fold oxidative, 32.5-fold ER) Fold rise in TIP production at the time of sampling GB1 RT-qPCR 60 min after dosing, one sample per condition, 20 ng of RNA per reaction. Late signals (Ct 32 to 37 in most reactions); the reference gene amplified in only one of five samples, so no normalization was possible. Panel designed and run. The late signals are not read as expression levels. Repeat planned with at least 80 ng of RNA (Section 9.6).(Section 9.6)
TetR production (aTetR × P(t)) TetR transcript under stress No valid peak; the reverse primer is to be replaced. Awaiting the repeat with a new reverse primer.
Reporter production (aRep × P(t), same promoter as TetR) sfGFP transcript rises with stress sfGFP: late signals (Ct 32 to 37 in most reactions) with scattered replicates. Without a working reference gene, no change with stress can be assessed. Awaits the repeat
TIP–TetR dissociation constant (design 0.25 nM; structural 3.675 and 8.428 nM) Amplitude falls as Kd rises; limits 30.2 nM (oxidative), 5.74 nM (ER) No binding assay in this round Estimates inside the oxidative limit, and the lower one inside the ER limit; a direct measurement heads Section 9.6
Growth-associated dilution (μ 0.35 h−1) One value shared by all modules OD600 readings every 45 to 60 min during culture preparation Estimate, consistent with those readings (about 0.3 to 0.4 h−1) and tagged for measurement in the parameter manifest
Tandem timer (maturation half-times 5.63, 16.91, 30.30 min; FRET efficiency 0.173; scaling factor f = 1) Ratio as the clock; FRET-corrected green as the dose readout Both channels and bright-field recorded in every field; bleed-through held at an illustrative 0.05 in the absence of single-fluorophore controls Literature values; the timer calibration images are a next-round item
Observation model (shot noise, 10-photon detection, photon scale 2.33642 per model unit, saturation 255) Precision bounds for dose and time 24-bit color TIFF files (8 bits per channel), ceiling 255 Ceiling taken from the setup; photon scale stated as provisional throughout
Zero-stress state Information analysis: 50 h at zero stress. Affinity sweeps: source initial state Same-day 0 µM culture after 3 h in galactose Starting states differ; the same-day 0 µM culture is both the denominator and the check, and is a required input to the tool
Stress input history (constant, or decaying at 1 or 3 h−1) Predicted fold depends on the assumed history H2O2 concentration over time not measured Identified in Section 9.5 as the first unknown to measure; directly measurable
Dose windows of the analyses Oxidative 20 to 300 µM; ER 700 to 3,200 µM; read at 3 h Oxidative: 20, 75, 300 µM inside, 600 µM above. ER: 1,000 and 2,000 µM inside; 100, 250, 500 µM below; none above 2,000 µM Covered for the oxidative branch; partly covered for ER
Early reading window (timing bound minimum at about 46 to 75 min) Most informative H2O2 reading Logged first imaging blocks at 51 to 78 min (5 Oct) and 55 to 70 min (7 Oct) Window sampled on two independent days
Autofluorescence (not in the Fisher observation model) Subtracted per stressor in the tool Unmodified strain through each stressor at the same doses Collected and applied to every per-cell result
Cell segmentation (Cellpose on bright-field; recall 0.91, precision 0.90 on 212 hand-marked cells) Per-cell values independent of reporter brightness Bright-field frame in every field 288 of 294 fields matched; benchmark scored in advance of use
Within-day induction test Each dose against the same day’s 0 µM culture, with minimum detectable effect and false-discovery control over 66 comparisons Same-day 0 µM tube in every run Dose-ordered increase under H2O2 on 7 October; not seen on the other two days
Model-versus-data fold Fold against the same-day 0 µM culture at the experimental doses and times. The fold figures in Chapters 5 and 6 are maximum over minimum across a dose grid, not against zero Per-field fold on reporter-positive cells Oxidative: model inside the measured interval in 0 of 18 conditions at constant stress, 5 of 18 at 1 h−1, 11 of 18 at 3 h−1
Empirical decoders (leave-one-day-out) Several independent days Three H2O2 and two DTT imaging days Checked on synthetic signal (Chapter 8); on these images they returned no dose or time estimate, as designed
Model-based decoder A calibration between model and camera units None available in this round Refused for real images by design; synthetic benchmarks only
Hill fit and dynamic range (effective Hill 1.796 and 4.244-fold oxidative; 2.572 and 2.977-fold ER) Fit of FRET-corrected sfGFP against dose 4 or 5 stressed doses per run, one culture per dose Awaits the calibrated, dose-responsive series in Section 9.6

Table 9.2. Correspondence between model or tool elements and wet-lab data.

9.5 What the comparison showed

The comparison was kept as a test. Two rules were set in advance and held: the model’s parameters were fixed before the first image existed and were not adjusted afterwards, and the held-out day split of the decoders was declared before any real data were decoded. Each result comes from a scripted run that records its configuration, the checksums of its inputs and outputs and the code version (Chapter 8).

What worked

The experiments were designed and labeled so that the tool could use them. Every field carries its dose, its time since the stressor and a same-day 0 µM control, 288 of 294 fields were matched to a bright-field frame, and the autofluorescence baseline was subtracted per stressor. The clearest signal came on 7 October under H2O2. The red channel rose above the day’s control by 2.0, 2.5 and 3.0 grey s−1 at 75, 300 and 600 µM (q = 0.007 at each dose), the share of reporter-positive cells rose by 14 percentage points at 600 µM (q = 0.007), and the dose trend was positive in all three readouts. That is a dose-ordered response, on the day with the largest reporter-positive population of the three. It rests on one day and on a positivity threshold taken from unmodified cells imaged in a separate session, so we present it as the strongest signal in the data set and the result the next round should confirm, not as an established dose response. Where no effect was detected, each comparison is reported with its minimum detectable effect (0.4 to 1.0 grey s−1 for the two channels on 5 and 6 October), so each null carries the size of effect these data could have shown.

Where model and data differ

Model and data were compared on the fold over the same day’s 0 µM culture, a scale they share. With the H2O2 input held constant, the model falls inside the measured 95% interval in 0 of 18 conditions. Allowing the effective input to decay, with assumed first-order rates and not fitted ones, raises this to 5 of 18 at 1 h−1 and 11 of 18 at 3 h−1. The H2O2 concentration in the cultures over time was not measured, so this shows how strongly the prediction depends on the exposure history and is not evidence for a clearance mechanism. The exposure history is therefore the first quantity to measure directly, and the calibration between model and camera units, which the model-based decoder needs, is the second. For DTT, no response was detected over 100 to 2,000 µM. The top doses reach the lower part of the modeled ER range.

What the timer still awaits

The red-to-green ratio reports time since a burst of new reporter synthesis. No stress-induced burst was detected in this round, so the ratio in these images reflects basal expression and the timer is untested, not contradicted. The measurement that would test it is specified in Section 9.6: a dose that produces a resolved induction, sampled densely from the first hour.

What the tool did with these images

ICHNOS provides an implemented decoding workflow, benchmarked on synthetic data with known dose or timing signals (Chapter 8). A worked example with hidden doses and times demonstrates the complete workflow from input to inference. Applied to the October images, its reliability checks identified insufficient support for dose or time estimation and withheld unsupported estimates. Model-based decoding of real images additionally requires calibration between measured fluorescence and model outputs.

Together, these components establish a computational framework for testing the dose and timing precision predicted by the information analysis. Experimental confirmation is the next step, requiring a calibrated dataset with distinguishable dose responses and temporal signals.

9.6 What the next round needs from the bench

Each open item above corresponds to a measurement that the wet lab can make and the model can use. Three are the priorities: a direct TIP–TetR binding measurement, an imaging calibration, and a DTT series that extends beyond 2,000 µM. Table 9.3 gives the full list with the model quantity each would constrain. These extend the measurements listed under Measurements the modelling identifies as decisive.

What the model needs What the wet lab would do What it constrains
A direct measure of TIP–TetR affinity Binding assay on purified TetR and the TIP fusion, for example SPR or MST Kd, against the amplitude window of 30.2 nM (oxidative) and 5.74 nM (ER)
Imaging calibration below about 2% shared error Offset 10 to 50, macro off, saturation warning on, 40× with the collar set, a flat-field slide, 10 to 20 consecutive shots of one field, a photon transfer series, an exposure series on one field to check that intensity scales linearly with exposure time, medium-only frames, lamp setting and time logged each session Photon scale, detection thresholds, and the model-to-camera calibration the model-based decoder needs
Doses that reach the model’s operating ranges DTT at 2,200, 3,300 and 5,000 µM; H2O2 at 100 and 400 µM, with a growth or viability check at the top doses The ER half-activation point and the choice between the two ER fits
A time course with at least nine points Sample the response at nine or more times per dose, beginning inside the first hour Static versus adaptive sensing; the early peak the information analysis predicts
Normalized transcript data UBC6 on the same RNA with redesigned primers, a second reference gene, an efficiency curve, no-RT controls, a new TetR reverse primer, at least 80 ng of RNA per reaction and three independent cultures per condition TIP production range, aTetR, aRep
Confirmation that the cassette is intact and at the HO locus Repeat the left-junction colony PCR with a more effective lysis step, starting with pSynOS4(alt1) Whether imaging and transcript results can be read as a test of the circuit as built
Single-fluorophore controls One strain per fluorophore imaged on the same setup The bleed-through coefficient, currently held at an illustrative value
The starting state of the cells at dosing Time course of the 0 µM signal in galactose (for example 0, 1, 2, 3, 4 h) before any stressor TetR accumulation, and a galactose state for the forward model
The stress input history H2O2 concentration over time in cultures at the OD used The exposure scenarios identified in Section 9.5 as the first unknown to measure
Growth rate in the experimental medium OD600 growth curve of each strain in SD−His with galactose at 30 °C μ, currently an estimate tagged for measurement
A quantified positive control for the cascade pCUP1 dose response on the calibrated setup, with a copper input module added to the model Integrity of TIP, TetR and the reporter, independently of the sensor
Single-cell data in large numbers Access to flow cytometry for the same cultures The information bounds and the empirical decoders

Table 9.3. Measurements for the next round.

For the next round, the predicted fold at each planned dose and time should be written down before the data are collected, so that the comparison remains a test and not a fit.

10. Future steps

Measurements the modelling identifies as decisive

The analyses on this page do not only describe the circuit. Several of them return specific requirements on the experiments that would test it, and these form the first set of next steps.

  1. 9

    time points

    A nine-point activation time course

    Model selection between the static and adaptive sensing descriptions could not be decided on the seven digitised points available, because the small-sample penalty at n = 7 exceeds the difference in fit. At the same residual variance, nine time points would separate the two structures by ΔAICc = 5.1 in favour of the adaptive description. The requirement is therefore a specific one: a validation time course needs at least nine points before model selection can report anything, and fewer points will not be resolved by better fitting.

    From 7.2 Ablation study

  2. < 2%

    shared imaging error

    Imaging calibration below roughly 2% shared error

    Averaging over cells removes per-cell noise but not error shared across a field, such as illumination drift, exposure variation or background subtraction. With a per-cell channel CV of 25%, imaging more cells stops helping beyond roughly 150 of them, and at 5% shared error the 30-minute timing target is not reachable at any cell count. The actionable requirement is therefore calibration rather than throughput, and the next step is to estimate channel noise and covariance from imaging controls instead of assuming them.

    From 7.2 Ablation study

  3. ~50%

    of structural mass passes

    A direct TIP–TetR affinity measurement

    The structure-derived affinity distribution spans both passing and failing regions of the circuit-response window, with its centre near the ER boundary. Under the stated criteria, roughly half the structural probability mass satisfies the joint requirement. No further computation narrows this, because the uncertainty is in the prediction rather than in the propagation. A direct binding measurement is the single measurement that would most reduce the uncertainty in the current assessment.

    From 5. Kd-specific analysis

  4. PTC

    photon transfer curve

    Instrument calibration of the detection thresholds and the photon scale

    The fold-change and ratio-spread thresholds used throughout the affinity analysis are operational assumptions, and the value chosen for the ratio threshold determines which criterion sets the boundary. Negative-control measurements on the imaging setup would replace both with measured values and make the resulting window an instrument specification rather than a stipulation. The same applies to the photon conversion used in the information analysis, which is provisional: every absolute precision scales as its inverse square root, so a photon transfer curve is what would turn the reported formulas into values.

    From 5. Kd-specific analysis and 7.3 Fisher information

  5. 0

    exposures decoded blind

    Decoder evaluation on known exposures

    The decoding analysis reports bounds conditional on the forward model, and held-out evaluation on the present dataset did not demonstrate recovery of dose or time. Testing the decoder against exposures of known dose and known age, with the analysis specified before the data are decoded, is what would establish whether the predicted precision is attainable. Two parameters of the adaptive motif enter the activation observable only as a product, so a longer time course is also what would make them separately identifiable. The software keeps the forward model swappable rather than hard-coded so that this choice can be revisited when such a time course exists. The ER branch additionally needs its own dose response measured before it can be compared with the oxidative one rather than reported separately.

    From 7.3 Fisher information

  6. 2nd

    chassis to validate

    Experimental transfer to a bacterial chassis

    The requirements above concern the system as it stands. A second group of next steps concerns whether the architecture transfers to another chassis at all. The bacterial implementation provides a computational starting point for testing ICHNOS in Escherichia coli, and the first question is whether the sensing, regulatory and reporter modules operate together under bacterial expression and growth conditions. These extensions remain prospective: the present simulations assess the oxidative implementation and do not establish ER-stress sensing in bacteria or functionality in mammalian cells, and each additional chassis would require its own computational assessment and experimental validation.

    What the transfer would require

    Characterising the bacterial sensing interface. pKatG-driven expression should be characterised across peroxide doses and timepoints alongside growth measurements, to test the assumed promoter response and guide the choice of TIP production levels. The effective cooperativity and activation threshold should be estimated together rather than transferred independently from different experimental contexts.

    Testing downstream regulation. The TIP–TetR interface should then be characterised in the bacterial chassis, with controlled TIP expression and reporter measurements constraining the regulatory response. A matched comparison between TetR autoregulation and constant TetR production, across the same doses and observation windows, would test the predicted improvement in dose-response linearity and dynamic range. Reporter maturation and ratio trajectories should be calibrated under the selected growth conditions, and sustained and transient exposures would test whether the measured signals distinguish different stress histories.

    Extending to other hosts. Beyond E. coli, the modular sensing, regulation and reporter design could be adapted to other hosts, including mammalian cells, with host-compatible promoters, expression systems and localisation strategies. The ER branch would need particular attention to host-specific unfolded protein response signalling: regulatory elements associated with ER chaperones, such as the HSPA5 promoter, could be investigated as candidate inputs to TIP production, with their basal activity, activation threshold and recovery characterised separately. Such experiments would need to distinguish ER-stress-dependent activation from broader changes in growth, viability and protein synthesis that also alter fluorescence.

    From 4. Assessing chassis transferability

11. Conclusions

Modelling brought the components of ICHNOS into a connected account of how stress sensing, TIP–TetR regulation and reporter maturation shape fluorescence. The transition from static sensing to PULSE made activation and adaptation explicit in both the oxidative and ER branches. It also revealed an important distinction: a transient sensor response does not necessarily become an equivalent pulse in free TIP or fluorescence. Understanding the device required following information through the complete circuit.

Each analysis sharpened that understanding. Controlled comparisons supported the contribution of TetR autoregulation to dose-response linearity and dynamic range, including in the proposed bacterial implementation. Structural and affinity analyses showed where uncertainty in TIP–TetR binding changes predicted performance. Physics-informed scenarios demonstrated that those requirements also depend on sensor parameters and exposure history. Information analysis then examined what the resulting signals could reveal, identifying conditions in which dose and elapsed time remain difficult to distinguish.

The comparison with experimental images completed this progression from mechanism to measurement. The workflow extracted per-cell signals and identified a dose-ordered oxidative response on one imaging day, but the available dataset did not support reliable dose or time estimation across independent days. Rather than forcing those observations into the model, we preserved the disagreement and quantified its consequences. Synthetic benchmarks established that the computational methods could recover informative signals under controlled assumptions; experimental evaluation established where those assumptions still require testing.

This work therefore delivers both findings and a practical foundation for the next iteration. The software connects model assembly, simulation, uncertainty analysis and image-based evaluation through documented configurations and automated checks. It allows new measurements, sensing modules and host-specific parameters to enter an existing workflow, while retaining a traceable relationship between assumptions and conclusions.

The next experimental priorities follow directly: resolve activation dynamics, calibrate fluorescence measurements, constrain TIP–TetR affinity and test inference against known exposures on independent days. These steps provide a concrete route from the present framework towards a validated sensing system.

ICHNOS began with the ambition to make cellular stress history readable. Our modelling established what that ambition requires, which predictions are supported and which measurements are still decisive. Its lasting contribution is a framework through which every new experiment can strengthen, or even challenge, the interpretation, bringing the system closer to a readout that researchers can trust.

References

  1. Delaunay, A., Isnard, A.-D., & Toledano, M. B. (2000). H2O2 sensing through oxidation of the Yap1 transcription factor. EMBO Journal, 19(19), 5157–5166. https://doi.org/10.1093/emboj/19.19.5157
  2. Luckner, S. R., Klotzsche, M., Berens, C., Hillen, W., & Muller, Y. A. (2007). How an agonist peptide mimics the antibiotic tetracycline to induce Tet-repressor. Journal of Molecular Biology, 368(3), 780–790. https://doi.org/10.1016/j.jmb.2007.02.030 (PDB 2NS8: https://doi.org/10.2210/pdb2ns8/pdb)
  3. Mirdita, M., Schütze, K., Moriwaki, Y., Heo, L., Ovchinnikov, S., & Steinegger, M. (2022). ColabFold: making protein folding accessible to all. Nature Methods, 19, 679–682. https://pubmed.ncbi.nlm.nih.gov/35637307/
  4. van Zundert, G. C. P., et al. (2016). The HADDOCK2.2 web server: user-friendly integrative modeling of biomolecular complexes. Journal of Molecular Biology, 428(4), 720–725. https://doi.org/10.1016/j.jmb.2015.09.014
  5. Kozakov, D., Hall, D. R., Xia, B., Porter, K. A., Padhorny, D., Yueh, C., Beglov, D., & Vajda, S. (2017). The ClusPro web server for protein–protein docking. Nature Protocols, 12(2), 255–278. https://doi.org/10.1038/nprot.2016.169
  6. Rodrigues, C. H. M., Myung, Y., Pires, D. E. V., & Ascher, D. B. (2019). mCSM-PPI2: predicting the effects of mutations on protein–protein interactions. Nucleic Acids Research, 47(W1), W338–W344. https://doi.org/10.1093/nar/gkz383
  7. Klotzsche, M., Goeke, D., Berens, C., & Hillen, W. (2007). Efficient and exclusive induction of Tet repressor by the oligopeptide Tip results from co-variation of their interaction site. Nucleic Acids Research. https://pubmed.ncbi.nlm.nih.gov/17545198/
  8. Nevozhay, D., Adams, R. M., Murphy, K. F., Josić, K., & Balázsi, G. (2009). Negative autoregulation linearizes the dose–response and suppresses the heterogeneity of gene expression. PNAS, 106(13), 5123–5128. https://pubmed.ncbi.nlm.nih.gov/19279212/
  9. Ma, W., Trusina, A., El-Samad, H., Lim, W. A., & Tang, C. (2009). Defining network topologies that can achieve biochemical adaptation. Cell, 138(4), 760–773. https://doi.org/10.1016/j.cell.2009.06.013
  10. Kuge, S., & Jones, N. (1994). YAP1-dependent activation of TRX2 is essential for the response of Saccharomyces cerevisiae to oxidative stress by hydroperoxides. EMBO Journal, 13(3), 655–664. https://doi.org/10.1002/j.1460-2075.1994.tb06304.x
  11. Kuge, S., Toda, T., Iizuka, N., & Nomoto, A. (1998). Crm1 (XpoI) dependent nuclear export of the budding yeast transcription factor yAP-1 is sensitive to oxidative stress. Genes to Cells, 3(8), 521–532. https://pubmed.ncbi.nlm.nih.gov/9797454/
  12. Gasch, A. P., Spellman, P. T., Kao, C. M., Carmel-Harel, O., Eisen, M. B., Storz, G., Botstein, D., & Brown, P. O. (2000). Genomic expression programs in the response of yeast cells to environmental changes. Molecular Biology of the Cell, 11(12), 4241–4257. https://doi.org/10.1091/mbc.11.12.4241
  13. Patil, C. K., Li, H., & Walter, P. (2004). Gcn4p and novel upstream activating sequences regulate targets of the unfolded protein response. PLoS Biology, 2(8), e246. https://doi.org/10.1371/journal.pbio.0020246
  14. Pincus, D., Chevalier, M. W., Aragón, T., van Anken, E., Vidal, S. E., El-Samad, H., & Walter, P. (2010). BiP binding to the ER-stress sensor Ire1 tunes the homeostatic behavior of the unfolded protein response. PLoS Biology, 8(7), e1000415. https://doi.org/10.1371/journal.pbio.1000415
  15. Khmelinskii, A., Keller, P. J., Bartosik, A., et al. (2012). Tandem fluorescent protein timers for in vivo analysis of protein dynamics. Nature Biotechnology, 30(7), 708–714. https://doi.org/10.1038/nbt.2281
  16. Choudhary, D., Foster, K. R., & Uphoff, S. (2023). Chaos in a bacterial stress response. Current Biology, 33, 5404–5414. https://pubmed.ncbi.nlm.nih.gov/38029757/
  17. Choudhary, D., Foster, K. R., & Uphoff, S. (2024). The master regulator OxyR orchestrates bacterial oxidative stress response genes in space and time. Cell Systems, 15, 1033–1045. https://pubmed.ncbi.nlm.nih.gov/39541985/
  18. Pillay, C. S., Eagling, B. D., Driscoll, S. R. E., & Rohwer, J. M. (2016). Quantitative measures for redox signaling. Free Radical Biology and Medicine, 96, 290–303. https://pubmed.ncbi.nlm.nih.gov/27151506/
  19. Choudhary, D., Lagage, V., Foster, K. R., & Uphoff, S. (2023). Phenotypic heterogeneity in the bacterial oxidative stress response is driven by cell–cell interactions. Cell Reports, 42, 112168. https://pubmed.ncbi.nlm.nih.gov/36848288/
  20. Seaver, L. C., & Imlay, J. A. (2001). Hydrogen peroxide fluxes and compartmentalization inside growing Escherichia coli. Journal of Bacteriology, 183, 7182–7189. https://pubmed.ncbi.nlm.nih.gov/11717277/
  21. Uhl, L., & Dukan, S. (2016). Hydrogen peroxide induced cell death: the major defences relative roles and consequences in E. coli. PLoS ONE, 11, e0159706. https://doi.org/10.1371/journal.pone.0159706
  22. Kim, S. O., Merchant, K., Nudelman, R., Beyer, W. F., Keng, T., DeAngelo, J., Hausladen, A., & Stamler, J. S. (2002). OxyR: a molecular code for redox-related signaling. Cell, 109(3), 383–396. https://pubmed.ncbi.nlm.nih.gov/12015987/
  23. Nevozhay, D., Adams, R. M., & Balázsi, G. Linearizer gene circuits with negative feedback regulation. Methods in Molecular Biology, Chapter 5. https://pubmed.ncbi.nlm.nih.gov/21468986/
  24. Rogers, J. K., Guzman, C. D., Taylor, N. D., Raman, S., Anderson, K., & Church, G. M. (2015). Synthetic biosensors for precise gene control and real-time monitoring of metabolites. Nucleic Acids Research, 43(15), 7648–7660. https://pubmed.ncbi.nlm.nih.gov/26152303/
  25. Dacquay, L. C., & McMillen, D. R. (2021). Improving the design of an oxidative stress sensing biosensor in yeast. FEMS Yeast Research, 21(4), foab025. https://doi.org/10.1093/femsyr/foab025