Engineering Success

Wet Lab


Project architecture

ICHNOS is built as three genome-integrated Saccharomyces cerevisiae strains (CEN.PK2-1C), each sensing a different stress input through one shared reporting logic.

Stress activates the sensing promoter, which drives expression of the peptide TIP. TIP binds and inactivates the repressor TetR. TetR otherwise silences a second promoter, pGAL1-D12, which drives a tandem-timer fluorescent reporter (sfGFP–mCherry). The tandem timer is what converts a binary “stress happened” readout into a record of both intensity and timing, since the two fluorophores mature at different rates and their ratio therefore encodes how long ago the reporter was switched on.

Only the sensing promoter changes between strains. Everything downstream of the TIP–TetR node, terminators, TetR cassette, reporter cassette, is identical across all three constructs, and all three integrate at the HO locus (YDL227C) using HIS3 selection. This was a deliberate architectural choice rather than a convenience: it means that a new input module can be added to ICHNOS by replacing a single promoter fragment, and it means that any difference observed between the three strains can be attributed to the sensing stage rather than to the reporting stage.

The cycles below cover the decisions that took this architecture from a diagram to a set of constructs, and the first experiments on those constructs. Four of them ended in a design being rejected. We have documented those in as much detail as the designs we kept, because the reasons a design fails are the part of this project most likely to be useful to another team.

☛Every cycle below follows the same four stages. Click a segment of its wheel, or the buttons underneath,to read that stage.

01

The Rejected HAC1 Splicing Reporter

Design rejected
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

Our first ER-stress sensor did not use a promoter at all. It was built on the post-transcriptional switch that controls HAC1, the transcription factor at the center of the yeast unfolded protein response. HAC1 mRNA is transcribed constitutively and is always present in the cell, but it is held translationally silent by a non-conventional intron; only when the ER-resident sensor Ire1 oligomerizes in response to accumulated unfolded protein does it excise that intron, allowing the message to be translated. We proposed to borrow this switch directly: place the HAC1 intron inside the mRNA of an mCherry2 reporter, so that the reporter transcript would be produced continuously but translated only once Ire1 fired.

The attraction was that this bypasses the single biggest weakness of promoter-based sensing, which is basal leakiness. A promoter always produces some transcript in the absence of stress; a translational block produces none of the protein until it is released. We also expected the readout to be fast, since mCherry2 matures in roughly twenty minutes, and to persist after the stimulus had passed, giving the stress-memory behavior that the whole project is organized around.

Build

We designed the chimeric reporter sequence with the HAC1 intron embedded in the mCherry2 message and, in parallel, set up the dry lab validation pipeline. Establishing that pipeline before ordering synthesis was itself a deliberate decision: the team had a limited synthesis budget, and we wanted every construct screened computationally for structure and regulatory integrity before any of that budget was committed.

Test

The in silico validation, run before any wet-lab work had begun, showed the design could not work. Translational silencing of HAC1 does not depend on the intron sequence being present somewhere in the message. It depends on a specific long-range base-pairing interaction between the intron and the 5′ UTR of the transcript, and on the secondary structure that this interaction forms across the ribosome-binding region. Inserting the mCherry2 coding sequence into that context changed the spacing and the folding of the surrounding RNA, and the predicted structure no longer reproduced the block. In other words, we had copied the sequence of the switch but not the geometry that makes it a switch, and the two are not separable.

Learn

The lesson was about modularity, not about ER stress. We had treated a regulatory mechanism as a part because it is described in the literature as a discrete element, when in fact it is a structural, context-dependent mechanism that does not survive relocation into a new sequence environment. This is exactly the failure mode that a parts registry is supposed to protect against, and it is why we now annotate every ICHNOS part with the sequence context it was validated in.

We abandoned intron-based sensing and moved to the promoter-driven architecture the project now uses: an ER-stress-responsive promoter drives TIP, TIP sequesters TetR, and de-repression of pGAL1-D12 drives the reporter. Accepting a promoter also meant accepting basal leakiness as a problem we would have to engineer around downstream rather than design away upstream, which is the reason the TIP–TetR inversion stage exists at all.

Lastly, the practical lesson from this cycle is to validate in silico before starting any experimental process.

02

Choosing the ER Homeostasis Sensor: pPDI1 versus pKAR2

Adopted — pKAR2
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

The ER module was not specified as a UPR-activation reporter. What ICHNOS needs is a sensor of ER homeostasis, a continuous readout of the folding environment, reporting chaperone demand across its range rather than flagging the moment an acute stress threshold is crossed. That distinction set the candidate list and the criteria.

Two direct Hac1 targets were considered: PDI1 (YCL043C), encoding protein disulfide isomerase, and KAR2 (YJL034W), encoding the ER-lumenal Hsp70 chaperone BiP. Three requirements applied: the promoter must report the homeostatic state continuously, not only under acute induction; its regulatory elements must be mapped well enough to annotate a reusable part; and its activity must not be governed by a feedback loop that the applied stressor closes.

Build

We assembled the promoter architecture of both candidates from the primary literature and mapped each against those three requirements.

Test

pKAR2 met all three; pPDI1 failed all three.

pPDI1 versus pKAR2 against the ICHNOS design requirements
CriterionpPDI1pKAR2
Fit to a homeostasis readout A UPR-induced foldase promoter: largely off at baseline, switch-like on induction. Reports that a threshold was crossed, not the state of the folding environment Constitutively active from a GC-rich basal region, with a UPRE adding graded induction on top. Output varies continuously with chaperone demand across the whole homeostatic range
Architecture and portability Not dissected to element-level resolution in S. cerevisiae; no minimal region defined, so a construct carries a long uncharacterized stretch Full regulatory region within ~230 bp (−245 to −9), with three independently acting elements mapped: GC-rich basal, heat shock element, 22 bp UPRE. The UPRE alone is necessary and sufficient when fused to a heterologous CYC1 TATA box
Feedback from the stressor Pdi1, with Ero1, catalyzes the disulfide bonds DTT reduces, so the promoter sits inside the loop resolving the stress and reports how far the cell has recovered Kar2 is an Hsp70 chaperone with no catalytic role in redox chemistry; the promoter tracks folding load without being governed by the reducing agent

Kar2 is also the right reporter on mechanistic grounds. SGD records that Kar2 regulates the unfolded protein response through its interaction with Ire1: the cell measures its own ER homeostasis by how much Kar2 is free rather than engaged with unfolded substrate. A promoter whose output follows chaperone demand is therefore reading the same variable the cell itself uses.

Learn

We selected pKAR2 as the ER homeostasis sensing module.

Reframing the module from UPR detection to homeostasis monitoring changed how we read the promoter’s high basal rate. In a switch-like reporter it reads as leakiness; in a homeostasis sensor it is what makes the low end of the range measurable at all, since a sensor that is silent until a threshold cannot report a gradient. The cellular states ICHNOS records are gradients, not binary events. We therefore treat the basal rate as a property of the sensor rather than a drawback, and demonstrating the architecture on a promoter that is never fully off is part of showing that it is not restricted to ON–OFF inputs.

One genuine limitation is documented on the part entry: the promoter carries a functional heat shock element alongside its UPRE, so ICHNOS ER experiments must run at constant temperature. Because the elements act independently, the HSE can in principle be mutated without touching the UPRE, and a team reusing the part can choose how much of the native promoter to keep. The fragment we ordered keeps the full 1000 bp native upstream region, so the mapped region of about 230 bp tells a reusing team where the regulation sits and how far the part can be trimmed, and does not describe our construct.

The transferable point: define what your sensor is for before comparing candidates, because the same property is a defect or a requirement depending on the answer. A high basal rate disqualifies a threshold detector and is exactly what a homeostasis monitor needs.

03

The Rejected Oxidative-Stress Sensing Module

Design rejected
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

The oxidative module initially used pTRX2, the obvious first choice: TRX2 is a direct Yap1/Skn7 target, responds strongly to peroxide, and is the standard promoter for peroxide-responsive readouts in yeast.

Build

We drafted the pTRX2 sensing fragment and, applying the criterion developed in Cycle 2, asked what regulates the promoter rather than only what it responds to.

Test

TRX2 encodes a thioredoxin, an active component of the redox buffering system that reduces peroxide. Its promoter is therefore inside the Yap1-driven loop that clears the analyte: as the cell restores its redox balance, the promoter shuts off. A reporter built on it tracks how far recovery has progressed rather than how much stress occurred, which is the opposite of what a memory device needs. As in Cycle 2, the issue is feedback on promoter activity and not added chemistry; driving TIP from pTRX2 does not produce thioredoxin.

We therefore turned to the synthetic promoter series developed for yeast oxidative-stress biosensors, in which several variants were built and compared head to head, and evaluated them against our own requirement. That requirement comes from the architecture rather than the stressor: because the TIP–TetR inversion stage loses gain, the sensing stage must deliver both low basal output and high sensitivity. A promoter that is merely strong when induced is insufficient if it leaks, since the leak is amplified through the same cascade as the signal.

Learn

We adopted pSynOS4(alt1), 171 bp. It has lower basal expression than the native alternatives, provides the sensitivity the cascade needs, and, being synthetic, carries no native regulatory context tying it to the pathway that clears peroxide.

The low basal rate also made this module the deliberate counterpart to the ER module. pKAR2 is never fully off and reports a gradient from a high baseline; pSynOS4(alt1) sits near zero until induced. Running both through the same TIP–TetR cascade and the same reporter lets us ask whether the recording architecture behaves consistently across two sensors with opposite baseline characteristics, which is a stronger test of a plug-and-play platform than two inputs of the same type would be. Each also exercises a different part of the design: the high-baseline sensor shows the device can resolve a gradient, and the low-baseline one shows it can detect a change against a near-silent background, where any leakiness in the cascade would dominate the signal.

The reasoning that removed pTRX2 was reached independently of the reasoning in Cycle 2 and gave the same answer, which is what convinced us it was a real design rule rather than a rationalization: where a native promoter is embedded in the loop that resolves your stressor, a characterized synthetic promoter is the better engineering answer.

04

The Rejected Single-Plasmid Design

Design rejected
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

With all three sensing modules chosen, we looked for savings. Synthesis was the largest single line in the project budget, and consolidating two of the sensing modules — pCUP1 and pSynOS4(alt1) — onto one plasmid would have cut it meaningfully. The arrangement would have been pCUP1 driving TIP and pSyn driving TIP, both feeding one shared TetR–reporter cascade, with the two inputs converging on a single reporter.

Build

We drafted the consolidated sequence in full and submitted it for review to the Thermo Fisher GeneArt scientific team, alongside our own analysis of the risks.

Test

We compared the consolidated design against three independent plasmids on two functional criteria, chosen because each corresponds to a way the circuit could fail silently rather than obviously.

One consolidated plasmid versus three independent constructs
CriterionConsolidated (one plasmid)Three independent plasmids
Genetic stability Two identical 51 bp TIP repeats in direct orientation, separated by a short interval, a substrate for single-strand annealing, which would loop out and delete the intervening pSyn promoter, producing a construct that still passes selection but has silently lost one of its inputs No repeated sequence within or between constructs; nothing available to loop out
Induction specificity Cu2+ drives Fenton-type chemistry and generates ROS, which can cross-activate the oxidative-stress promoter sitting on the same plasmid; a reporter signal could not be attributed to either input Each sensing promoter is induced and read out in a separate strain, so every measurement has one unambiguous input

Both risks were confirmed on review. The first is a construction-stability problem that would appear as irreproducibility between colonies rather than as an outright failure, which is the worst kind to inherit. The second is more damaging still, because a copper-driven ROS burst cross-activating pSynOS4 would produce data that look like a working dual sensor and are in fact uninterpretable.

Learn

We dropped the consolidated design and kept every sensing module on its own construct. The cost was a modest increase in synthesis spend; what we bought was a circuit whose output can be attributed to a single input, and a set of constructs that cannot quietly delete part of themselves. This is also the answer to the question reviewers most often ask about ICHNOS — why three strains rather than one multiplexed strain — and we would rather it sat here, in the reasoning, than in the architecture summary.

More generally: identical repeated sequence in direct orientation is a liability in any yeast construct, and any two sensing modules sharing a chassis need their inducers checked for chemical cross-talk before the layout is fixed.

05

Making the Fragments Synthesizable

Redesigned — 5 → 8 unique fragments
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

The three finalized constructs had to be split into a minimal set of linear DNA fragments for in vivo assembly. Because the architecture keeps everything downstream of TIP identical, we designed the split so that the shared regions (the TetR cassette and the reporting cassette) became shared fragments, ordered once and used in all three assemblies, with only the first fragment varying. This is the point where the modular architecture stopped being an aesthetic preference and started paying for itself in ordering cost.

Build

We submitted an initial three-pieces-per-construct split to IDT: one variable fragment (HO Left Flank, HIS3 and the sensing module) plus two shared downstream fragments (the TetR cassette and the reporting cassette). That makes nine pieces to assemble across the three strains, but only five unique sequences to synthesize.

Test

IDT’s sequence-complexity screening flagged three synthesis-blocking problems, all arising from sequence features we had introduced for functional reasons and had never evaluated for manufacturability. The promoter regions were repetitive enough to break single-piece synthesis of the sensing fragments. The GGGGS flexible linker ahead of mCherry, a standard choice for keeping two fluorophores in a tandem timer independently folded, is by construction a tandem repeat at the nucleotide level, and it was repetitive enough to break synthesis of the reporting fragment as well. On top of that, the pSynOS4(alt1) sensing fragment carried a long internal repeat that splitting alone could not resolve, because any split still left one piece containing the repeat.

Learn

We redesigned the set as eight unique fragments, seven linear gBlocks and one gene in a custom plasmid, in place of the five sequences first submitted. Four remedies were matched to the three problems: a further split of the first fragment (which also showed that its 5′ end, the HO Left Flank and HIS3, is identical in all three constructs and needs to be made only once), a further split of the reporting cassette, codon optimization of the repetitive ORFs for S. cerevisiae so that the linker region encodes the same peptide from non-identical codons, and, for the one fragment that splitting could not rescue, delivery as a PCR-recoverable insert inside a carrier plasmid instead of a pure linear gBlock.

The final eight-fragment set
FragmentContentShared
1HO Left Flank + HIS3All constructs
2pCUP1 sensing modulepCUP1 only
3pKAR2 sensing modulepKAR2 only
4–5pSynOS4(alt1) sensing module, split for internal repeats; fragment 5 recovered by PCR from a carrier plasmidpSynOS4(alt1) only
6TetR expression cassetteAll constructs
7–8Reporting cassette (terminators, sfGFP, linker, mCherry, pGAL1-D12, HO Right Flank), split for size and repeat contentAll constructs

Each strain assembles from a subset of these eight fragments, five for pCUP1 or pKAR2, six for pSynOS4(alt1), with only the sensing module changing between them.

The lesson we would pass on is that manufacturability is a design constraint and not a downstream formality: a sequence that cannot be synthesized is not a design, and the features most likely to break synthesis are often the standard ones. Flexible linkers, tandem promoter elements and repeated tags are all common, all sensible at the protein level, and all repeat-rich at the DNA level. We now run complexity screening at the design stage rather than at the ordering stage.

06

Choosing the RT-qPCR Reference Gene

Adopted — UBC6
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

The RT-qPCR panel needed a stable internal reference gene to normalize against. This looks like a routine choice and is not, because the standard answer in yeast work is ACT1, and ACT1 is known to fall as cultures move from exponential to stationary growth (Teste et al., 2009). A stressed culture is exactly where that kind of drift can hide. Choosing it by default could have introduced a systematic error into every expression measurement in the project, in a direction that is difficult to detect after the fact.

Build

We used the candidate pool established by Teste et al. (2009), who screened thirteen S. cerevisiae reference genes, the field-standard ACT1 among them, for expression stability across growth phases on glucose and galactose using the geNorm algorithm. Working from a published, systematically screened panel rather than from a shortlist of our own gave us a ranking we did not have to build ourselves. Its conditions are not ours, though: it covers growth phases and carbon sources, not chemical stress.

Test

We applied a single functional criterion: does expression hold steady when the state of the culture changes (growth phase, carbon source), as opposed to under standard exponential growth on glucose? Our cultures grow in galactose, so the galactose data matter most to us.

Reference-gene stability across growth phases and carbon sources
GenesBehavior across growth phases and carbon sources
ACT1, PDA1, RDN18, TDH3Not recommended. ACT1 and PDA1 fall in stationary phase, TDH3 scatters widely and ranked among the worst candidates, and RDN18 is not an mRNA and is expressed far above the other genes
ALG9, TAF10, TFC1, UBC6Ranked most stable by geNorm across the growth phases, carbon sources and strain backgrounds tested
Learn

We chose UBC6. It is not a lone standout, and we do not present it as one: the geNorm top tier is a small cluster of comparable candidates rather than a single winner, and ALG9, TAF10 and TFC1 would all have been defensible. What made UBC6 the choice is that it stayed stable across the growth phases, carbon sources and strain backgrounds in the screen (Teste et al., 2009), galactose included, which ACT1 did not. That is not the same as stable under H2O2, DTT or CuSO4, which the screen did not test, so we state it at that strength. Cycle 10 shows how this choice held up in our hands.

The transferable lesson is that the default reference gene of a field is validated for that field’s typical conditions, not for yours, and that normalization is a place where an unexamined default quietly corrupts every downstream number.

07

Testing Integration and Cassette Expression

Both cassette ends read out
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

The constructs are assembled in vivo from five to six fragments and integrated at the HO locus. We chose two readouts at opposite ends of the cassette. HIS3 sits at the 5′ end, and CEN.PK2-1C is his3, so growth on SD−His shows that end is present and expressed. The sfGFP–mCherry reporter sits at the other end, so fluorescence, once the culture is in galactose, shows that end is present and expressed. Each junction has a unique homology overlap, which limits the order of assembly.

Build

We transformed CEN.PK2-1C by LiAc/PEG with the matching fragments (five for pCUP1 and pKAR2, six for pSynOS4(alt1)) and plated on SD−His at 30 °C. A no-DNA control went through the same protocol.

Test

Colonies grew for all three transformations and the no-DNA plates stayed clear. The reporter end was examined in liquid culture after the switch to galactose (Cycle 8), because pGAL1-D12 is held off on glucose. Fluorescence without induction would be basal pGAL1-D12 activity, and it would not show that TetR represses.

Learn

Growth on selective medium is consistent with integration and expression of the 5′ end of the cassette in all three strains, and the reporter signal is the matching readout for the other end. The two readouts sit at opposite ends of an assembly whose junctions are individually unique, so with assembly order constrained by design, the two signals would bound the whole construct.

08

Inducing the Circuit and Handing the Data to the Dry Lab

First dataset collected
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

We wanted to know whether each strain responds to its stressor. Each stressor was applied to its strain, cultures were followed by fluorescence microscopy, and the images went to the dry lab for quantitative analysis. Same day's unstressed cultures were induced with the following doses: H2O2 at 0, 20, 75, 300 and 600 µM, DTT at 0, 100, 250, 500, 1000 and 2000 µM.

Build

The pSynOS4(alt1) strain was induced with H2O2, the pKAR2 strain with DTT and the pCUP1 strain with CuSO4. The cells were moved to galactose medium at least three hours before the dose, because pGAL1-D12 is switched off in glucose. Samples were imaged over time: H2O2 from 0 min to 7 h, DTT from 0 min to 6 h and CuSO4 from 0 to 4 h. Each sample was imaged in brightfield, sfGFP and mCherry channels, with unmodified CEN.PK2-1C cultures exposed to the same stressors as the autofluorescence baseline.

Test

Fluorescence was recorded in both channels across the series. Every field was saved with its sample, dose and time since stress. The dry lab analyzed the images with ICHNOS VAIL, which segments cells on the brightfield images, applies the masks to the fluorescence channels, subtracts autofluorescence and returns a per-cell sfGFP and mCherry signal. H2O2 raised the red signal on one of three days, no DTT response was detected, and the red/green ratio did not change with time.

Learn

Each stressor produced fluorescence that could be captured and quantified, and the images became the dry lab’s first real dataset.

Fields from one culture are not biological replicates, so independent replication exists only across days. Where the camera clock, folder names and log disagree, the log is the authority. Next time we would continue with fluorescent imaging, so more data could be collected and the uncertainty could be minimized. We would also agree on dose ranges with the dry lab, and add a reporter-positive control every day.

09

Colony PCR: Diagnosing a Blank Gel

Protocol changed
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

This cycle was optional. Integration and cassette function were already supported by growth under selection, the constrained assembly order and reporter fluorescence, so we ran colony PCR as independent cross-validation, to add position to presence and function. The primer pair was designed before transformation: Colony_OUT_FWD anneals about 180 bp upstream of the insertion site, on native genomic sequence that is not part of any synthesized fragment, and Colony_IN_REV anneals at the 3′ end of Fragment 1, inside the synthetic cassette. Neither primer gives a product alone, so a 1.65 kb band can only come from a Fragment 1 that has joined the genome at the HO locus. It would not show that Fragments 2 to 8 follow it. The plan was a yeast colony PCR with bead-based lysis, since S. cerevisiae has a rigid β-glucan and mannoprotein cell wall that resists gentle lysis and requires mechanical grinding.

Build

The beads arrived late, so we attempted the assay with the lab’s existing equipment and recorded the limitation in advance. Colonies were picked from the SD−His plates, resuspended in 20 mM NaOH and heated at 95 °C for 10 minutes (the rapid alkaline method of Lõoke et al., 2011). After a 1 minute spin at 10,000 × g, 2 µL of the cleared supernatant went into a 20 µL KAPA Taq reaction with the two primers, annealed at 55 °C. A WT colony served as the negative control.

Test

No bands were visible on the gel, in any strain. Random errors such as a missed pipetting step would hit some tubes and spare others, so a failure everywhere points to a systematic cause. We went through the possible causes:

  • Failed integration. The colonies grew without histidine (HIS3 expressed at the 5′ end) and the cultures showed reporter fluorescence (reporter present at the 3′ end), which a missing or grossly truncated cassette cannot do. Neither shows where the DNA sits, so this cause is less likely, not excluded.
  • Primer design. The pair was screened in silico at the design stage for specificity, amplicon length and dimers, and nothing was flagged.
  • Mis-assembly. Unlikely, since each junction has a unique homology overlap.
  • Template. NaOH and 10 minutes at 95 °C is a gentle lysis compared with bead grinding, and the amount of colony picked was not controlled, so DNA release may have been partial or variable.

We concluded that incomplete lysis was the most probable cause, and discussed this with our instructor Dr. Hélène Martin-Yken, a specialist in fungal morphogenesis and cell wall synthesis, and separately with Sylvia Mangani, a PhD candidate in the laboratory, who agreed.

Learn

The conclusion is a reasoned elimination, not a measurement. We could not test every alternative, so incomplete lysis is the most probable cause, not a demonstrated one. The gel carried a WT negative control but no positive control, so a lysate that cannot be amplified and a primer pair that does not work would look the same on it.

Yeast needs a lysis step that has been shown to work: its cell wall resists gentle treatment, so a quick lysis does not always release enough template, and bead beating is the more thorough method. This carried directly into Cycle 10, where we used beads. Reagents that cannot be substituted should be secured before the experiment date.

Because this cycle was cross-validation, its failure cost us a line of evidence and not a result. The strains remain supported by selection, fragment design and fluorescence. The locus is still owed, and the experiment that provides it is this same assay run with bead-based lysis, a quantified lysate and a positive-control primer pair on an unrelated genomic locus.

10

RT-qPCR: Clean RNA but Low Yield

Inconclusive - low template concentration
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

We wanted to quantify TIP. Fluorescence shows only the last step of the circuit, and an RT-qPCR panel tracking TIP alongside TetR and sfGFP, normalized to UBC6 (from Cycle 6). The second purpose was to address the question Cycle 9 left open: transcripts from both ends of the construct would show that the downstream fragments are in the cell and expressed, although not where in the genome they sit. We carried the Cycle 9 lesson into the protocol, replacing alkaline lysis with mechanical disruption in glass-bead tubes.

Build

Cultures were dosed and harvested after 60 minutes, for every strain with and without the inducer. Cells were transferred to MN Bead Tubes Type B for mechanical lysis. Because the laboratory did not have the dedicated horizontal bead-beater adapter for the Macherey-Nagel tubes, disruption was carried out on a standard benchtop vortex at maximum speed. Without the adapter, energy transfer to the beads is less efficient and cell wall breakage is incomplete, releasing less RNA into the lysate.

The cleared lysates were purified on silica columns using Clean-up kit. NanoDrop readings showed that the eluted RNA was clean, but excessively dilute. We needed to run three separate one-step RT-qPCR runs and technical replicates for each sample. After evaluating the NanoDrop results, budgeting for twelve reactions capped our input at 20 ng of template RNA per 20 µL reactions, while the protocol supports up to 100 ng of template RNA per reaction. Keeping triplicates forced us to run at one-fifth of the manufacturer’s upper input recommendation, leaving very little margin for cDNA synthesis during the 30-minute reverse transcription hold at 48 °C. Every gene included a no-template control, and unmodified WT RNA went into the UBC6 run as a positive control.

Test

The controls behaved. Reactions without RNA stayed flat for UBC6, sfGFP, and GB1, and WT RNA amplified UBC6 in two of three reactions with a single melt peak at 78 °C. On the experimental samples S1 to S5, however, the 20 ng input did not yield enough cDNA to carry the reference gene: UBC6 gave a signal in only one of the fifteen reactions, so there is no ΔΔCt in this cycle and we do not report one. The circuit genes, driven by stronger promoters, gave late signals (Ct 32 to 37 for sfGFP and GB1 in most reactions) with scattered replicates, and TetR gave no valid peak, so these signals could not be evaluated as expression. After obtaining this data, it became important for us to test the “insufficient template DNA theory”. That’s why we proceeded with gel electrophoresis, which ran and showed only the ladder and no band in any sample lane.

Learn

The extraction and amplification route works, but one-step RT-qPCR sensitivity is gated by the mass of the template entering reverse transcription and subsequently the lysis efficiency. While the use of glass beads is fundamental for yeast disruption, mechanical lysis efficiency relies heavily on strict adherence to the protocol utilizing a proper automated homogenizer rather than manual vortexing. Furthermore, mandatory NanoDrop consumed a fraction of our already sparse yield. Had time permitted additional extraction rounds to secure an adequate template mass, the assay would have likely yielded conclusive quantitative results.

Lastly, according to our Trouble Shooting Manual we would also include a no-RT control to locate a failure instead of inferring it.

Dry Lab


Model architecture

The ICHNOS model describes the same device as the wet lab’s project architecture. A stress input activates a sensing promoter, which drives the peptide TIP. TIP binds and inactivates the repressor TetR, which otherwise silences pGAL1-D12, which drives a tandem-timer reporter (sfGFP–mCherry). The two fluorophores mature at different rates, so their red/green ratio is designed to encode how long ago the reporter was switched on.

We built the model in five modules: the stress sensor, TIP production and degradation, TIP–TetR binding, de-repression of pGAL1-D12, and the tandem-timer reporter. Only the sensor changes between strains. The binding and reporter modules stay the same, which is what let us test the sensor on its own in the ablation below.

We use the model for dose response and linearisation, for the timer and memory window, for a prior on the TIP–TetR affinity, and for a decoder that estimates dose and time from microscope images.

Most results in Tracks 1 and 2 are predictions or calibrations to literature data. Track 3 is our first test against our own imaging data, and it came back negative.

☛Every cycle below follows the same four stages. Click a segment of its wheel, or the buttons underneath, to read that stage.

Track 1: building the PULSE oxidative sensor

Track 2: the binding affinity (Kd)

Track 3: the software and decoders

00

Static Versus Adaptive Sensing

Design revised
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

The static model used a Hill function to turn stress dose directly into a TIP production rate. A static input sends an ODE system to a fixed point, so that model could address dose response and linearisation, which live in the steady state, but not the tandem-timer claim, which lives in the transient. The experiment samples that transient.

Build

We rebuilt the sensor around an explicit activation state and a feedback mediator (Yap1 → Trx2 → Yap1) and called it PULSE. The reporter and binding modules were kept identical, so only the sensor differs.

Test

We compared the two sensors on the precision of a joint dose-and-time estimate (Cramér–Rao bound).

  • The static sensor is the better dose meter: dose range 4.69 against 2.69, Hill coefficient 1.70 against 1.97.
  • In the window where timing matters, the adaptive sensor is 4.9× better, and 1.3× better once the gain difference is removed.
  • The transience is intracellular: Gasch et al. held peroxide at 0.32 ± 0.03 mM, so S_ox stays a constant parameter.
  • A perfect adaptor moves the Hill coefficient only from 1.97 to 1.98, while removing adaptation changes the regime.
Learn

A sensor that adapts changes quickly, and a rate of change carries time information, whereas a plateau says nothing about when it was reached. So the structure matters more than the tuning.

The 4.9× is a bound computed inside our own model, not a measurement. Cycle 5 shows the model gets the time shape wrong, and Cycle 12 shows the decoder failed on real data with a flat timer. These data cannot say whether the shape error contributed, so we treat the advantage as a prediction to test.

An ablation is only informative if everything except the ablated module is held identical, which is why the binding and reporter modules were left untouched.

Track 1: Building the PULSE oxidative sensor

01

Two Checks Defined Before Calibration

The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

Before calibrating anything, we specified two closed-form checks.

Check 1 — basal TIP at zero stress stress = 0  ⇒  TIPbasal = beta_basal_ox / k_deg_TIP = 5 nM

Check 2: a dose of 400 µM must produce a pulse.

Build

SimBiology, with A_ox and X_ox as parameters with rate rules. Literature start values:

k_off_ox
5
d_x_ox
1.75
k_on_ox
50
K_act_ox
271
n_ox
1.7
Test

Check 1 returned exactly 5 nM, so volume scaling is not double-counted. Check 2 failed: A_ox rose to 0.93 and stayed. The drive (33 /h) outweighed the feedback (2.86) twelvefold, and the quadratic gives A = 0.93 exactly.

After changing k_off_ox from 5 to 100, a pulse appeared (peak ~0.85 at 5 min, plateau ~0.35). It was still quantitatively wrong: decay in ~18 min against 45, and the plateau is not extinction.

Learn

The feedback term was an order of magnitude too weak, so we kept the structure. k_off_ox alone moved both timing and depth, which Cycle 2 addresses.

02

Reparameterising to Follow the Algebra

The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

Fix k_off_ox (depth) and d_x_ox (speed), targeting half-extinction at ~0.75 h with deep extinction.

Build

A grid search at 400 µM:

First grid k_off_ox ∈ {20, 50, 100, 200, 500}  ×  d_x_ox ∈ {0.3, 0.6, 1, 1.75}

After the first results we reparameterised:

Reparameterised grid R = k_off · k_x / d_x R ∈ {30, 60, 120, 250, 500, 1000}  ×  d_x ∈ {0.4, 0.6, 1.0, 1.75} Stop time 10 h.
Test

No combination in the first grid hit both targets. d_x = 0.3 is below growth dilution (~0.35 /h), and the 2 h stop was too short (τ = 3.3 h), so equal k_off / d_x ratios gave different plateaus, which is algebraically impossible.

A rerun returned plateau = 0.000 everywhere, because S_ox had been left at 0 and createSimFunction reads the model’s current value for anything not passed. In the R grid, the plateau was constant across d_x for fixed R to three decimals. Our hypothesis that large d_x kills the pulse was refuted: all 24 rows pulse, and the earlier “NaN” meant “never falls below 50 % of peak”.

Learn

Every script declares every parameter it depends on, and a zero-signal check runs first. The non-identifiability became a measurement.

03

A Prediction the Sweep Refuted

Prediction refuted
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

We predicted that raising k_on_ox would not move the equilibrium, since the drive already dominates.

Build

A sweep over k_on_ox alone, then an analytic solution of the steady state.

Test

The prediction was wrong: the TIP plateau went from 39.5 to 80.5 nM.

Analytic steady state u = k_on_ox · Hill(S) / (k_off_ox · k_x_ox / d_x_ox) A_ss = (−u + √(u² + 4u)) / 2 Gives 0.3051 against 0.305 in SimBiology.

Scaling k_on_ox and k_off_ox together leaves both plateaus identical.

Learn

Four parameters share one steady-state degree of freedom, so k_on_ox is identifiable only through its ratio to k_off_ox.

04

The Right Number at the Wrong Level

Parameters revised
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

The module spans several measurement levels (Yap1 oxidation, native transcription, synthetic-promoter reporter). A number valid at one level can be invalid at another.

Build

We traced each parameter back to its primary measurement.

Test

We found three errors of this kind.

  • Production ratio. beta_max / beta_basal at 25 / 5 capped induction at 5×, but the data show 6.5×. The “5” belonged to the bare native promoter. The circuit’s synthetic promoter has range 23.6, so beta_max_ox = 118 nM/h.
  • Hill coefficient. n_ox moved from 1.7 to 2.75. The 1.7 describes the promoter output and had been misplaced at Yap1 activation.
  • Buffer node. We had argued it was unnecessary from 60-min mRNA, but that mRNA integrates the preceding 30 to 40 min. Retracted.
Learn

Every parameter has to be traced back to the measurement it came from, and that level recorded.

A number at the wrong level passes every check that looks at magnitude, because the number itself is correct.

05

The Time Shape the Structure Cannot Produce

Limitation documented
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

The module reproduced dose response and adaptation, but the time shape had never been checked.

Build

Densitometry of the seven oxidation time-course lanes, with a reducing-gel loading control and a second crop (maximum deviation 0.052). The oxidised fraction is near-complete at 2.5 min, stays above 0.60 until 30 min, then collapses between 30 and 60 min. We then built four structural variants at 400 µM: linear buffer, saturated K_M = 0.05, saturated K_M = 0.5, and slow X.

Test

Our calibrated curve peaked at 0.865 at ~2 min and decayed smoothly with no plateau. All four variants converged to 0.43–0.48 at 60 min, where the data are 0.12. The Michaelis constant K_M moves amplitude, never shape.

The fall comes from the conservation term 1 − A_ox, not the feedback, because A_ox has no lifetime of its own. GFP-Yap1 is nuclear at 12 and 30 min and diffuse at 45 and 60 min, which points to a missing nuclear-retention step.

Learn

The model misses the 30-minute hold and sudden drop because it has no nuclear-retention step. Adding one would cost up to a day and make parameters unidentifiable, so we kept the model and documented the limitation.

We judged that the timer needs the sharp rise, which the model gives, but this is untested: the flat timer in Cycle 12 cannot confirm it.

Track 2: The binding affinity (Kd)

06

Predicting Kd by Docking

The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

The model used Kd = 0.25 nM, borrowed from ATc, an unrelated molecule, and TIP has no measured affinity. We needed a TIP-specific Kd, so we ran two lines in parallel.

Build

Structural: ClusPro, HPEPDOCK and AlphaFold3, with PRODIGY affinity predictions. Modelling: a frozen Kd sweep from 0.0025 to 5000 nM, fold-change inverted against affinity, and uncertainty propagated by Monte Carlo and Bayesian updating.

Test

The tools agreed on where TIP binds and disagreed on how: pose deviations 3.4 to 28.3 Å, four of ten poses reversed, docking-score against energy correlation −0.20. The consensus Kd of ≈313 nM gave a 2.4 % probability of function, which implied TIP binds too weakly.

Learn

Agreement on the site is not agreement on the pose, and a consensus over scores that disagree is not evidence of accuracy. We looked for data to validate the weak-binding conclusion before accepting it.

07

The Crystal Structure and the Missing Monomer

Prior revised
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

Validate the weak-binding conclusion against experimental data.

Build

We searched for an experimental structure and found 2NS8. Contact analysis showed each peptide touches two TetR monomers, whereas every docking run had used one. We recomputed the binding energy on the crystal, changing only which chains were included.

Test
Binding energy by receptor definition
Receptor Contacts ΔG (kcal/mol) Kd
Dimer A+B84−11.28.1 nM
Dimer C+D83−11.73.7 nM
Monomer A alone35−8.3950 nM

Omitting the second monomer costs 2.9 kcal/mol (117-fold). The new prior is ≈5.5 nM, and the median Kd moved from 360 nM to 6 nM, raising P(functional) from 2.4 % to 9.5 %.

Learn

Check for an experimental structure before predicting one. The two crystallographic copies agree to 0.5 kcal/mol, which shows the calculation is reproducible, not that it is accurate. Empirical affinity scores carry errors of several-fold or more, and the interval is still wide (0.1 to 327 nM at 90 %). The missing monomer also does not explain why the docking tools disagreed by up to 28 Å.

08

The Threshold That Was Read Wrongly

Threshold corrected
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

After the correction, the timer still looked like the limiting factor (9.5 % probability of function). We checked how the 0.05 ratio-spread threshold had been defined in its source.

Build

We re-read the source and re-ran the sweep with its three zones in place of a single pass/fail line:

Ratio-spread zones as the source defines them < 5 %   |   5 – 20 %   |   > 20 %
Test

The maximum spread anywhere in the swept range is 0.0815, so the timer is not binding at any realistic affinity.

How the limiting factor moved
Stage Median Kd P(functional) Limiting factor
Monomer docking, threshold 0.05360 nM2.4 %Peptide binds too weakly
After dimer correction6 nM9.5 %The timer
After threshold correction6 nM~50 %The instrument
Learn

A numeric threshold needs a recorded source, since a 4× misreading moved a probability by about 20 points. The limiting factor is now the microscope’s detection limit, not the binding or the timer, so the next measurement is that limit from a negative control.

Track 3: The software and decoders

09

Binding Images to the Acquisition Log

The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

Every image must be tied to its condition: strain, stressor, dose and time since stress. A wrong dose is visible and recoverable, but a wrong timestamp fabricates the quantity the device estimates.

Build

One clock offset per session, with each image paired to the nearest log row.

Test
  • Iteration 1. 271 of 344 pairs matched and 60 landed in the wrong folder. The offset was estimated from the very pairing it was meant to enable, so replicate fields ~2 min apart shifted whole blocks by one row. It settled at ~47 min against a true ~49.4.
  • Iteration 2 (offset estimated from within-folder ordering, then matched within folders first). 294 of 297 log rows matched, 292 in their own folder, residual median 0.44 min. The five session offsets agreed within about 40 s.
Learn

An alignment estimated from its own matching converges on a biased answer that looks consistent, so anchor it to structure that does not depend on it. Where the log and folder names disagree, the log wins. We set this rule when the 9 Oct DTT 100/200 µM folders proved swapped.

10

A Mask Cannot Come From the Signal It Measures

Results withdrawn
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

We needed one mask per cell. It had to work on non-transfected cultures, which are the autofluorescence reference, and it could not use either fluorescence channel, because the red/green ratio is the timer.

Build

Masks from the summed fluorescence channels, with a watershed split and object sizes set in pixels.

Test

Over 90,388 objects, the masks were mostly noise on non-transfected sessions. On transfected sessions they split cells in two and missed every cell that was not bright. The size settings were in pixels chosen for another magnification:

Why the pixel sizes were wrong at 40×  →  0.1725 µm/px min_size = 30 px  ⇒  ~0.9 µm²

Against the wet lab’s marked cells (Cycle 11), recall was 0.44 and precision 0.31.

Learn

A mask taken from the signal it measures is biased in the direction of the hypothesis: it selects the brightest cells in exactly the comparison meant to detect brightness. We withdrew every per-object number from this run and moved segmentation to the bright-field frame, with min_size set in µm.

11

Choosing a Segmentation Method

The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

We needed to know which bright-field method was best, and eyeballing a few crops could not settle it. The wet lab marked the centre of every cell on seven crops (212 cells, plus 15 unsure), and we scored each method against that reference at 0.5 µm tolerance.

Build

Two classical methods (transmitted, brightfield_rim), first at default settings and then tuned, and Cellpose 4 (cpsam) at defaults. Tuning used four sessions, with three held out.

Test
Pooled over all seven crops
Masks Recall Precision
transmitted, default0.640.53
transmitted, best of 18 tuned0.700.67
brightfield_rim, best of 48 tuned0.500.67
Cellpose, nothing tuned0.910.90

Cellpose recall ranged from 0.74 to 1.00 per crop. Because the split was declared in advance, the classical figures are not the best of a search; because Cellpose was never tuned, all seven crops are test data for it. The choice between methods was still made on these scores, so the headline figure is the best of three candidates rather than a fresh held-out estimate. Only the classical methods were tuned on any of these crops, so the remaining bias runs in their favour and the comparison, if anything, understates the gap.

A second problem came with the fix. The masks now come from a different frame than the measurements, so we registered them to fluorescence: 288 of 294 rows matched (median shift 3.2 px, 20 rows above 20 px, one at 233 px). Four fields with no bright-field frame are refused and not segmented from fluorescence.

Learn

Tuning the wrong method (66 settings, ~0.1 F1) was worth less than changing it (+0.2 to 0.3). The cost is ~141 s per field. We segment with Cellpose on bright-field.

The reference has limits: one annotator, seven crops, and point marking only, so it scores detection and not outline accuracy.

12

Testing the Decoder on Data It Had Never Seen

No decoder beat chance
The design-build-test-learn cycle The design-build-test-learn cycle DESIGN
Design

Leave-one-day-out, per stressor, fixed before any real data were decoded. There are three independent H2O2 days and two DTT days, and three decoders: absolute, paired and model.

Build

Synthetic competence tests first: recover a real signal at ≥0.9 accuracy with ≥80 % coverage, return the prior when none exists, remove a day offset only in the paired decoder, and come out confidently wrong with a biased model.

Test
Leave-one-day-out results
Decoder Accuracy Chance Info gain
H2O2 absolute0.060.20−0.51 bits
H2O2 paired0.100.20−0.60 bits
DTT absolute0.190.17−0.57 bits
DTT paired0.170.17−0.44 bits
H2O2 model0.250.20−21.9 bits
DTT modeln/an/a0.00 bits

The empirical and model-guided decoders did not demonstrate reliable dose inference across imaging days. Although some accuracy scores exceeded chance, information gain remained negative, showing that these scores alone did not establish useful predictions. The H2O2 model decoder assigned fields to 0–75 µM with high confidence, while its out-of-distribution check did not reliably identify the incorrect predictions. The uncalibrated model overpredicted the H2O2 response by approximately 1.7–5× at ≥75 µM, while the tested DTT doses lay below the model’s main activation range.

Within-day analysis, using bootstrap tests with Benjamini–Hochberg correction across 66 comparisons, identified a dose-ordered reporter response on one of the three H2O2 days. Population red fluorescence increased by 2.0, 2.5 and 3.0 grey·s⁻¹ at 75, 300 and 600 µM, respectively (q = 0.007 each). The timer ratio showed no consistent temporal trend, with slopes from −0.08 to +0.02 h⁻¹. In the worked example, the time-decoding workflow returned validation verdicts.

Learn

Testing on held-out imaging days clarified what is needed to translate fluorescence into reliable dose and time estimates. With three H2O2 days and two DTT days, the reference dataset offered limited information about day-to-day variability, while the flat timer response left its temporal readout unresolved under these conditions. The H2O2 model decoder also showed why accuracy alone is insufficient: an above-chance score could coexist with overconfident predictions. We therefore added validation verdicts that explain whether each observation supports an estimate and identify when more information is needed.

NextThese findings define the priorities for the next cycle: reassessing H2O2 calibration against the measured induction, expanding the reference across independent days, and including a reporter-positive control and doses spanning the model’s informative range. The same leave-one-day-out evaluation provides a consistent way to assess progress.