Model

Spatial Modeling

Complete diffusion-field, coverage, leakage and micro-lesion calculations.

Reported result

The spatial analysis reports both boundary conditions for intra-nodule coverage and explicitly sums neighbouring AHL fields. Its cluster calculation does not create an additional activation window at realistic micrometastatic spacing under the declared geometry.

Figure 5. Equivalent isolated radius (Eq. (39)) of a cubic cluster of 150 µm lesions, against cluster size, at three spacings. Answers §3.2: at realistic micrometastatic spacing no cluster leaves the OFF end of the band, and reaching the ON band takes 512 touching lesions — a contiguous millimetre-scale mass that the single-lesion model already says switches on. The multi-lesion extension opens no new risk window.
Figure 5. Equivalent isolated radius (Eq. (39)) of a cubic cluster of 150 µm lesions, against cluster size, at three spacings. Answers Micro-lesion field superposition: at realistic micrometastatic spacing no cluster leaves the OFF end of the band, and reaching the ON band takes 512 touching lesions — a contiguous millimetre-scale mass that the single-lesion model already says switches on. The multi-lesion extension opens no new risk window.

Coverage and leakage calculation

Question. Of what is produced inside a nodule, how much is destroyed outside it? Split the degron’s benefit into “makes less” and “spreads less”. And is intra-nodule flatness a consequence of the diffusion lengths, as previously claimed?

Governing equations

The fraction of production that is destroyed outside a lesion of radius R has a closed form, with g the exterior amplitude function of Eq. (37) and α=R/λ:

E(R,λ)=3g(α)(1+α)e−αα3   (31)
Gfield(R,λ)=Ψcentre(R)Ψin(R;R)   (32)
total off-target reduction=ρpool×EuntaggedEtaggedconfinement share=ln(confinement)ln(total)   (33)

where

E(R,λ) is the fraction of production destroyed outside a lesion of radius R.

R is the lesion radius (µm) and λ the screening length of the effector field (µm).

α=R/λ is the radius-to-screening-length ratio.

g(α) is the exterior amplitude function of Eq. (37).

Gfield(R,λ) is the core-to-rim ratio of the effector field inside the lesion.

Ψcentre(R) is the normalised AHL at the lesion centre (Eq. (35)) and Ψin(r;R) the normalised internal field (Eq. (36)).

ρpool is the intracellular effector-pool ratio, untagged over tagged.

Euntagged and Etagged are the outside-destroyed fractions of the two constructs.

The share is taken in logs because the two contributions compose multiplicatively. The closed form agrees with direct numerical integration to 10−4, which our tests check, so this section does not rest on hand algebra.

Calculated results

Two boundary conditions, no decision between them. Intra-nodule flatness differs 1.5–2× between the free-field and washout treatmentsCoverage and leakage calculation. We report both, which means “how flat is the field inside a nodule” is a question this project answers only as an interval.

At R=400 µm:

Speciesλ​λ/R​Destroyed outsideFree-field core:rimλ<R?
Lactate5099 µm12.7599.77 %1.539✗
AHL3000 µm7.5099.36 %1.566✗
GSDMD-N (no SsrA)670.8 µm1.67791.10 %1.784✗
GSDMD-N (+SsrA)300 µm0.75073.16 %2.072✅

Both constructs leak heavily. The 671 → 300 µm change sounds categorical — from larger than the nodule to smaller — but per molecule it moves off-target exposure by only 1.245×:

retention=1−0.73161−0.9110=3.015×,confinement=0.91100.7316=1.245×
total=5.375×1.245=6.693×,confinement share=ln1.245ln6.693=11.5%

About 88.5 % of the degron’s spatial safety benefit comes from making less, and only 11.5 % from confining what is made. The more quotable claim (retention improves 3.0×) is not the one that drives safety. This agrees with SsrA biomass–potency calculation, where the degron’s value also lands on suppressing the accumulated pool.

Intra-nodule flatness is a boundary condition, not a length scale. Last cycle attributed core:rim ratios of 1.011–1.021 to the diffusion lengths dwarfing the nodule. That attribution does not hold: under free diffusion into surrounding tissue with the same decay rate, the same parameters give graded fields of 1.54–2.07×. Even lactate, with λ/R=12.75, shows a 1.54× gradient. And the tagged effector’s 300 µm range is shorter than the 400 µm nodule radius in any case, so its field should not be called a long-range average under any boundary condition.

What actually flattens the field is a bounded domain with rim washout. Both treatments are defensible — free field assumes equal decay inside and out, washout assumes a well-perfused rim carries effector away — and the truth sits between them, so we report both and do not pick. The therapeutic conclusion (flat coverage spares nothing, including the proliferating rim) survives; its justification changes from a scale argument to a boundary-condition argument.

Micro-lesion field superposition

Question. The AHL diffusion length is ~3000 µm, far larger than any single lesion. Does a cluster of micro-lesions 1–2 mm apart share one signal pool and switch itself on? If so, how large must the cluster be — and is that still micrometastasis?

Governing equations

The steady-state AHL equation is the screened (modified Helmholtz) form of the reaction–diffusion equation, whose spherically symmetric solutions are standard25:

D∇2C−δC+q(x)=0,λ=D/δ,α=R/λ,s=r/λ   (34)

Because LuxI sits under pPepT rather than under pLux, AHL production does not depend on AHL concentration. There is no autoinduction loop, so Eq. (34) is linear, superposition is exact, and an arbitrary three-dimensional arrangement of spherical sources is solved by summing closed-form single-sphere fields. We had planned a 2-D axisymmetric finite-difference solver; it is not needed, and the analytic result is more accurate, cheaper and easier to defend.

The same fact yields an architectural conclusion that was not previously stated: the quorum module is a colonised-volume integrator, not a bistable switch — no hysteresis, no sharp threshold, a graded response. This agrees with Lesion-size calculation, where AHL integration carried 6.5× the weight of the hypoxia term.

Normalised to q/δ, for a single uniformly producing sphere:

Ψcentre(R)=1−(1+α)e−α   (35)
Ψin(r)=1−(1+α)e−αsinhss,r≤R   (36)
Ψout(r)=λg(α)e−r/λr,g(α)=αeα−(1+α)sinhα,r≥R   (37)

The two expressions match at r=R, and for small α the exterior field reduces to the screened (Yukawa) point-source kernel. Our tests verify by finite difference that both branches satisfy the PDE.

Cluster centre concentration and cooperation factor:

Ψcluster(i)=Ψcentre(R)+∑j≠iΨout(dij),coop=Ψcluster(i)Ψcentre(R)   (38)

Absolute AHL depends on βQ/KQ, on which last cycle’s two calibrations differ 27-fold, so we report no absolute concentration and issue no ON/OFF verdict. Instead we invert Eq. (35):

Req:Ψcentre(Req)=Ψcluster   (39)

the equivalent isolated radius — the single lesion that would produce the same signal at its own centre. The threshold cancels, letting us compare directly against last cycle’s 150 µm (OFF) → 1000 µm (ON) interval.

Finally, the small-α scaling that decides the dispersion question:

(Ψcentre∼α22)own,∝R2vs(Ψout∼R33λ2d)neighbour,∝R3/d   (40)

where

C is the AHL concentration, D its diffusion coefficient and δ its decay rate.

q(x) is the volumetric AHL production rate at position x.

λ=D/δ is the screening length.

α=R/λ and s=r/λ are the radius and the radial position in screening-length units.

Ψcentre(R) is the normalised AHL at a single lesion’s centre (Eq. (35)), Ψin(r) the normalised internal field (Eq. (36)) and Ψout(r) the normalised exterior field (Eq. (37)).

g(α) is the exterior amplitude function of Eq. (37).

Ψcluster(i) is the normalised AHL at the centre of lesion i within a cluster.

coop=Ψcluster(i)/Ψcentre(R) is the cooperation factor.

dij is the centre-to-centre distance between lesions i and j.

Req is the equivalent isolated radius: the single-lesion radius producing the same centre signal.

Worked substitutions

R=150 µm, α=0.05: Ψcentre=1−1.05e−0.05=1.2091×10−3. R=1000 µm, α=1/3: 4.4625×10−2.

Numerical note. Eq. (35) and g(α) cancel to second and third order respectively, so below α<0.01 we switch to series expansions. The threshold must not be set higher: at α=0.05 the closed form still carries ~12 significant digits while a four-term series carries 5.

Calculated results

SpacingLesionsCooperationEquivalent radiusReaches ON?
300 µm (touching)134.74×333.3 µm✗
276.75×400.6 µm✗
12516.91×651.7 µm✗
1000 µm131.89×207.5 µm✗
1253.95×303.0 µm✗
2000 µm1251.77×200.8 µm✗

No cluster reaches the 1000 µm equivalent. Cooperation is real but weak: at realistic micrometastatic spacing (≥ 1 mm), 125 lesions reach only 201–303 µm.

How large would it have to be?

Touching clusterCooperationEquivalent radiusCentre-to-centre span
53=125​16.91×651.7 µm1.2 mm
73=343​30.37×897.0 µm1.8 mm
83=51237.55×1009.8 µm ← first ON2.1 mm

512 touching 150 µm lesions is a contiguous mass 2.1 mm across (2.4 mm including the outer radii). That is no longer micrometastasis — it is a tumour, and the single-lesion model already says a tumour of that size switches on. The multi-lesion extension opens no new risk window.

That conclusion does not depend on the screening length

λ=3000 µm is inherited from last cycle’s run manifest and is the least defensible number in this section: it is D/δ built from an AHL diffusion coefficient and an AHL decay rate, neither of which we could source to a direct measurement (Luminal repression calculation says the same about the decay half). Published tumour-tissue diffusion coefficients for a small metabolite are of order 10−5 cm² s⁻¹26, which with an 8 h half-life puts λ in the low millimetres — consistent with 3000 µm, but as a plausibility check, not a citation for the value.

So the honest move is to show the conclusion over a range rather than defend the point estimate. Across a ten-fold span of λ:

λ​Req at 125 lesionsReq at 512Lesions needed to reach 1000 µm
1000 µm608.4 µm888.7 µm1000
3000 µm (ours)651.7 µm1009.8 µm512
10000 µm665.9 µm1049.4 µm512

No value of λ in that range lets a cluster reach the ON band at fewer than 512 lesions, and a shorter screening length makes it harder, not easier. The quantity the conclusion rests on is the count, and the count is bounded below across the whole span. That is why this section survives having its worst parameter undetermined, and it is the reason we report λ as scenario rather than quietly treating 3000 µm as known.

And dispersion is strictly worse than compaction, confirming Eq. (40):

LesionsEquivalent radius (dispersed)Volume-matched singleRatio
4200.4 µm238.1 µm0.842
8251.0 µm300.0 µm0.837
27400.6 µm450.0 µm0.890
125651.7 µm750.0 µm0.869

Dispersing a given burden always produces less centre signal than compacting it (0.84–0.95×), because a lesion’s own contribution scales as R2 while a neighbour’s scales as R3/d.

Every modelling choice here is conservative in the same direction: steady state (transients fall below steady values), equal colonisation density across lesions (real micrometastases are probably colonised worse), no commensal lactonase degradation of AHL, and a lattice arrangement (which favours cooperation more than a random one).

For safety this strengthens the micro-lesion argument. For efficacy it says the circuit cannot clear true micrometastases, and distant disease has to be addressed immunologically rather than by colonisation — which Immune cascade: scenario calculations takes up.