Model

Gate Calibration

From measured GFP responses to a calibrated two-input gate.

Reported result

The 24 h reporter data support multiplicative factorisation; the transient responses do not. The interaction estimate is −0.011 ± 0.157 at 24 h. All experimental inputs, transformations and worked substitutions are retained below.

Gate interaction across measurement times
Values reported in the modeling manuscript, replotted for comparison. Complete source data and calculations remain expanded below. View source values and calculations →

Circuit and measured inputs

Figure 1. The two-input AND gate. Hypoxia drives LuxI from pPepT; lactate drives LuxR from the native lldPRD operon promoter; only the LuxR–AHL complex opens pLux on the effector. Chassis is E. coli Nissle 1917, delivery is oral, and the indication is pMMR/MSS colorectal cancer. That combination is not ours: orally dosed EcN selectively colonises adenomas in ApcMin/+ mice and was enriched in tumour over normal tissue in a double-blind trial of patients dosed before resection1, and EcN replicates at the live/necrotic border of tumours while not colonising spleen or liver at all2. The lactate sensor is BBa_M36021, the native E. coli lldPRD operon promoter3, a choice that turns out to carry the whole luminal safety argument§2.3. Two things about that part are worth stating up front: it is a 332 bp basic part derived from BBa_K822000, and the Registry currently marks it deprecated, which is a documentation status rather than a defect but is the kind of thing a reader should hear from us rather than discover.
Figure 1. The two-input AND gate. Hypoxia drives LuxI from pPepT; lactate drives LuxR from the native lldPRD operon promoter; only the LuxR–AHL complex opens pLux on the effector. Chassis is E. coli Nissle 1917, delivery is oral, and the indication is pMMR/MSS colorectal cancer. That combination is not ours: orally dosed EcN selectively colonises adenomas in ApcMin/+ mice and was enriched in tumour over normal tissue in a double-blind trial of patients dosed before resection1, and EcN replicates at the live/necrotic border of tumours while not colonising spleen or liver at all2. The lactate sensor is BBa_M36021, the native E. coli lldPRD operon promoter3, a choice that turns out to carry the whole luminal safety argumentLuminal repression calculation. Two things about that part are worth stating up front: it is a 332 bp basic part derived from BBa_K822000, and the Registry currently marks it deprecated, which is a documentation status rather than a defect but is the kind of thing a reader should hear from us rather than discover.

Experimental data and modeling roles

The analysis is anchored to 391 measurements reported in the modeling manuscript, grouped into the experimental blocks below. These are the team's experimental measurements rather than literature values.

The experimental blocks, and the decision each one settles.
BlockWhat was measuredMeasurementsWhat it decides
1–2OD₆₀₀ growth curves: 2 constructs (GSDMD, GSDMD–SsrA) × 4 conditions (21/1 % O₂ × 0/20 mM lactate) × 8 timepoints × 3 replicates192the carrying capacity K at every siteTissue output calculation and the chassis cost of the SsrA tagSsrA biomass–potency calculation — fitted in Growth fitting and carrying capacity
3reporter fluorescence intensity: 4 corners × 4 timepoints × 3 replicates48the magnitude of the hypoxia contribution, 1.33×Oxygen and lactate contributions
4reporter percent-positive: 4 corners × 4 timepoints × 3 replicates48the AND-gate interaction test itself — the one result the entire safety chapter is factored onGFP positive-rate calibration, and the held-out prediction that validates itHeld-out gate predictions
5co-culture killing, dose series: 7 constructs × 3 doses (6/8/10 OD) × 3 replicates, CT2662the dose–kill power law b=2.651, and through it every dose number in Dose–kill fit and required dose and the whole safety-dose collision in Joint dose and safety constraint
6co-culture killing, cell-line pairing: 7 constructs × 2 lines (CT26, L929) at 10 OD41the construct’s own selectivity index, 3.3×Within-block construct selectivity

Read the last column: block 4 is what lets the gate be written as a product at all, and block 5 is what turns the model’s safety margin into a dose in OD. Neither is replaceable by a literature value, because no published study used this construct.

Two measurements do more work than their cost suggests, and both are worth saying out loud:

Running both constructs in the same growth block is what makes the first-hour burst interpretableGrowth fitting and carrying capacity. The tagged strain is the control for the medium, so “lactate slows growth” is ruled out by the data rather than argued away.

Running block 5’s seven constructs at the same three doses is what lets the killing be taken net of the gfp carrierDose–kill fit and required dose, instead of crediting the effector with the chassis’s own effect.

Experimental inputs and readout handling are documented below. Wet-lab figures are linked above; no missing replicate values are reconstructed.

Experimental data and readout handling

The reporter intensity block records undetected measurements as 0, and there are 19 of them. Sixteen are contradicted by the percent-positive block measured on the same samples, which reports 2–32 % positive cells where the intensity read zero. Those zeros are the instrument’s floor, not darkness. We keep them in the means and we refuse to let them be denominators. One group — 1 % oxygen with lactate at 24 h — reads 40433, 32134 and 0; we print all three, because a mean with an SD would imply a noise model that is not there.

Two oxygen levels and two lactate levels do not identify a sensor midpoint or slope. No sensor parameter is fitted to our reporter dataset. The parameter census distinguishes transferred literature priors for nQ and KO2 from declared scenario values.

One more of this kind. The fold changes from the probit inversion — 17× for oxygen and 642× for lactate — are proportional to the cell-to-cell spread of expression, and a group mean plus a positive fraction cannot resolve that spread. We report them as conditional on it and build nothing on them. The multiplicativity test itself does not use it, which is why that is the claim we lead with.

GFP positive-rate calibration

Question. Read as raw fluorescence the two inputs together give 227× where a multiplicative gate predicts 2768×. Is that 12× shortfall real sub-multiplicativity, or an artefact of a saturated readout? And once the artefact is removed, what does the data actually support?

This matters because every safety result below writes the gate as a product of three arms (Eq. (11)). This section is the measured basis for that factorisation.

Corners: A = 21 % O₂ · B = 1 % O₂ · C = 21 % + 20 mM lactate · D = 1 % + 20 mM.

Governing equations

If per-cell log-expression is normal with condition-dependent mean μ and a common spread σ, and the cytometry gate is a fixed threshold θ, the positive fraction is the standard probit model4:

p=Φ(μ−θσ)⇒z≡Φ−1(p)=μ−θσ   (1)

A fold change between two corners is then

fold=exp(σΔz)   (2)

θ cancels from any difference; σ does not, and Eq. (2) depends on it exponentially.

A multiplicative gate means the two inputs are additive on μ, hence additive in probit units, hence the two-way interaction vanishes:

I=zD−zC−zB+zA=!0   (3)
SE(I)=∑c∈{A,B,C,D}sc2/nc   (4)

where

μ is the condition-dependent mean of per-cell log-expression.

σ is the common spread of per-cell log-expression.

θ is the fixed cytometry threshold for gating positive cells.

p is the positive fraction of cells above the cytometry gate.

Φ(⋅) is the cumulative distribution function of the standard normal distribution, and Φ−1(⋅) its inverse (the probit function).

z is the probit-transformed positive fraction.

fold is the fold change between two experimental corners.

I is the two-way interaction term, zero for a multiplicative gate.

SE(I) is the standard error of I.

zA, zB, zC, zD are the probit values of the four corners A, B, C, D.

sc2 and nc are the sample variance and sample size of corner c.

σ scales every term in Eq. (3) equally, so it cancels from the test. That is why the interaction test is the load-bearing result and the fold magnitudes are decoration.

Parameter values and sources

SymbolMeaningValueGrade
p​positive fractionmeasured, 4 corners × 3 replicates × 4 timepointscalibration
θ​cytometry thresholdcancels — never needed—
σ​cell-to-cell spreadnot identifiable from this dataset—
σ9.23​spread reproducing last cycle’s published folds2.53not a measurement
—multiplicativity criterionI within 2SE of zeroprotocol

Worked substitutions

At 3 h corner A reads 0 % positive, where Φ−1 diverges, so that timepoint cannot be inverted at all; our code raises rather than silently clipping, because clipping would fabricate a finite z.

24 h corner means (probit of each replicate, then averaged):

CornerPositive (3 replicates)z¯​s​
A 21 %5.5 / 5.6 / 5.2 %−1.60440.0190
B 1 %31.9 / 31.3 / 31.9 %−0.47610.0097
C 21 % + lactate81.3 / 85.9 / 81.4 %+0.95250.1068
D 1 % + lactate98.3 / 98.9 / 96.4 %+2.06990.2494
I24h=2.0699−0.9525−(−0.4761)+(−1.6044)=−0.0110
SE=0.01902+0.00972+0.10682+0.249423=0.02469=0.1571

Reconstructing last cycle’s published folds from Eq. (2) at σ=2.53: e2.53×1.1283=17.37× for oxygen against its published 17.4×, and 644.87× for lactate against 642× — the method was a probit inversion, and it implicitly chose that spread.

Calculated results

TimeOxygen B−AOxygen D−CLactate C−ALactate D−BInteractiont​
6 h0.7261.0100.8231.107+0.284 ± 0.2401.18
9 h0.5921.7271.1702.306+1.135 ± 0.3503.24
24 h1.1281.1172.5572.546−0.011 ± 0.157−0.07

At 24 h the two oxygen estimates agree to 0.98 % and the two lactate estimates to 0.43 %, and the interaction is zero within error. The oxygen effect is the same with and without lactate, and the lactate effect the same under normoxia and hypoxia — which is what additivity, and so multiplicativity, means. These are two independent internal checks rather than one fit.

At 9 h the interaction is significantly positive (t=3.24, 8 df, p≈0.01): the gate is super-multiplicative while it is still turning on. This is consistent with hypoxia acting on rate rather than level — three readouts put the 24 h hypoxia increment at only 1.18–1.33×, where mid-course it is 3.4×. A pure rate effect shows up as apparent synergy in the transient and disappears once both corners saturate.

So the AND claim belongs to the endpoint. Mid-course ON/OFF ratios must not be extrapolated with a multiplicative model. Held-out gate predictions turns this from a test into an out-of-sample prediction.

The interaction test is the load-bearing result here; the fold magnitudes are decoration. σ cancels from the test (Eq. (3)) but not from a fold, so we report the folds as σ-conditional and build nothing on them:

σ​Oxygen foldLactate foldImplied population CV
1.03.1×12.9×131 %
2.5317.4×645×2,452 %
4.091.2×27,660×298,000 %

The last column is worth a line, because σ and the coefficient of variation are the same statement for log-normal expression (CV=eσ2−1). The σ that reproduces last cycle’s published 17× and 642× implies a population spread of about 2,450 % — four decades of fluorescence. Possible for a strongly bimodal reporter, but it was never stated as a claim: it was fixed implicitly by inverting to the answer. We quote those two numbers only to say where they came from.

Oxygen and lactate contributions

Three readouts agree on how much the hypoxia input contributes at 24 h: positive fraction rises 1.18× (82.9 → 97.9 %), intensity 1.33× (253,571 → 337,332), and the untagged strain’s endpoint OD₆₀₀ not at all (1.380 → 1.380). Mid-course, at 6 h and 9 h, hypoxia multiplies the positive fraction by 3.4×.

Lactate is necessary and close to sufficient; hypoxia sets how fast the gate opens, not whether it opens. This is why Luminal repression calculation’s luminal lactate load is close to the whole safety story.