WellPlotted & Glow Getter

We built WellPlotted to record and plot plate-reader measurements and Glow Getter to model fluorescence and growth. We used both tools to analyze our Module 2 sfGFP experiments.

  1. Future tagged targets

    Collect a separate dataset for each sfGFP-tagged protein.

  2. Plate reader

    RFU and optical density at a documented wavelength over time.

  3. WellPlotted

    Inspect time courses and variation. Prepare model inputs separately.

  4. Glow Getter

    Fit and evaluate a response after collecting compatible data.

  5. Harvest experiments

    Test harvest conditions and measure soluble recovery and fusion integrity.

Proposed workflow for sfGFP-tagged proteins. Our current measurements cover J23106 expressing standalone sfGFP, using OD630 because of the plate-reader setting. For each tagged target, we plan to collect measurements, fit and test its model, and compare predictions with recovered protein. We prepare compatible input files separately for WellPlotted and Glow Getter.

What Each Tool Does

WellPlotted organizes optical density (OD) and fluorescence (RFU) readings by well, promoter and AHL condition. It plots individual wells, compares conditions and calculates RFU/OD.

Glow Getter fits models to our measurements and predicts fluorescence for a chosen AHL condition and time. Our J23106 analysis covers six AHL conditions from 0–24 hours. The Results page describes the measured expression and growth.

WellPlotted exports a plate-shaped CSV. Glow Getter reads one record per measurement, so we convert the files while keeping the run, well and time labels. The synthetic tutorial shows this process with generated data.

Our plate reader measured absorbance at 630 nm, so we report OD630 and RFU/OD630. Some older figures and od600 fields use OD600 for the same readings. WellPlotted labels plots with the recorded wavelength. See the Model page for measurement and calibration details.

WellPlotted: Recording a Plate

WellPlotted is a Python/Tkinter desktop app with a 96-well plate layout: rows A–H and columns 1–12. Click a well to enter its promoter, AHL condition, OD and RFU. Starting a new measurement round saves the current readings and clears OD and RFU while keeping the condition labels.

Each imported CSV represents one measurement round. Columns are numbered 1–12, rows are labeled A–H, and each well contains four values: promoter|ahl|od|rfu. Convert plate-reader exports to this format before importing them.

Use the saved-round selector to correct earlier readings. Saving replaces that round’s file. Zero readings are retained, blanks stay missing, and invalid numbers are rejected. Promoter and AHL labels stay fixed after the first round.

WellPlotted source code on iGEM GitLab.

Selecting Wells and Reading the Plots

On the Analysis tab, select individual wells, select all, or choose a group by promoter or AHL condition. Three views are available:

  • Standard OD/RFU: plots individual wells or groups with matching promoter and AHL labels. Grouped curves show mean ± standard deviation. OD and RFU can be viewed together or separately.
  • RFU/OD: divides each entry’s RFU by its paired OD, then summarizes matching conditions. The default is the median, with mean and observed min–max bars also available. Entries with missing or nonfinite readings, or OD at or below zero, are excluded.
  • Six conditions plus media: compares all six J23106 AHL conditions with the media reference on shared axes. This view uses all matching loaded wells.

The bars describe variation in the supplied readings: standard deviation for grouped OD/RFU plots and observed min–max ranges for ratio plots. If technical triplicates are averaged before import, each averaged entry contributes one ratio to the summary.

WellPlotted curves showing median raw RFU per OD630 for each AHL condition, with observed min–max bars. The image uses the older OD600 label for these OD630 readings.
Figure 1. Module 2 Measurements in WellPlotted. Lines show median raw RFU/OD630 by AHL condition; bars show the observed min–max range. Media fluorescence is retained. The image’s OD600 label refers to our OD630 readings. View full size.

Swipe across the panels, or open them at full size.

Figure 2. Conditions Compared with Media. Colored lines show median raw RFU/OD630, dashed gray lines show the media reference, and bars show the observed min–max range. OD600 in the image refers to OD630. View full size.

WellPlotted plots the values supplied in the CSV. Prepare any media correction before import. The figures above use raw fluorescence and show media as a reference; Glow Getter’s experimental analysis below uses media-corrected fluorescence. RFU/OD630 describes fluorescence relative to culture turbidity.

Grouping Similar Wells

The clustering option groups selected wells by their total, peak or final OD or RFU readings. Total means the sum of the readings. Choose the features to include; promoter and AHL labels can also be included as integer-encoded values.

The app standardizes the selected features, then uses K-means with a chosen cluster count or DBSCAN in automatic mode. It plots the mean curve for each group and skips wells with incomplete signal histories.

OD and RFU are grouped separately, so matching cluster numbers can contain different wells. Including condition labels also affects how the wells are grouped.

Running WellPlotted

Use Python 3.12 with Tkinter, install requirements.txt, then run python Working.py. To save a session with its wavelength, use python Working.py --output-directory path/to/session --od-wavelength 630. Reopen saved rounds with python Working.py --csv-folder path/to/session.

Record acquisition times in Elapsed hours. When every saved round has a time, graphs use elapsed hours; otherwise they use measurement round numbers. Times must increase between rounds.

The WellPlotted README covers installation, CSV formatting, saved sessions and tests.

Glow Getter: Models and Experimental Predictions

Glow Getter imports measurements, fits models, runs simulations and saves plots. A local SQLite database stores measurements, parameters, model runs and predictions.

Its equation models connect LuxR production, AHL binding, pLuxR activation and fluorescence. The time-course model also includes growth and GFP maturation. These models start with demonstration parameters that can be fitted to experimental data.

For our sfGFP analysis, we averaged technical wells, subtracted matching media fluorescence once and divided by preblanked OD630. We compared equation models with a direct median predictor. This predictor aligns the measured curves, takes the median at each time point and interpolates between those points for a requested condition and time.

The DNA-to-protein prototype translates a coding sequence and scales an sfGFP baseline using protein length, theoretical molecular weight and codon adaptation index. That scaling preserves the sfGFP condition ranking. Our next step is to test its yield predictions with protein-specific calibration and recovery measurements.

Run python main.py --help for the available commands. The Model page explains the models, and the Results page reports our earlier prediction comparison.

Glow Getter source code on iGEM GitLab.

Glow Getter with Our Wet-Lab Measurements

We used our J23106 fluorescence and growth measurements from 0–24 hours to fit curves and test predictions. The figures below compare measured RFU/OD630 with fitted curves and predictions for measurements left out of model fitting.

Swipe across the graph, or open it at full size.

Figure 3. Measured Fluorescence and Fitted Glow Getter Curves. Points show median measured corrected RFU/OD630; shaded bands show the interquartile range across runs. Lines show pooled-median fits with and without the 5× peer screen. Each panel has its own vertical scale. Technical triplicates were averaged before subtracting matching media RFU and dividing by preblanked OD630. View full size.

Testing Predictions

We tested predictions with 50 grouped 80/20 train–test splits. Each split left out 193 measurement groups, kept technical triplicates together and retained hour zero in training. Shared media readings associated with test groups were excluded from training, and the peer screen used training data only.

Swipe across the graph, or open it at full size.

Figure 4. Glow Getter Prediction Checks. Both methods use the same 9,650 test predictions. Color shows the number of predictions in each bin on a shared logarithmic scale. Mean and median absolute percentage error (APE) summarize performance; small measured signals can produce large percentage errors. Measurement groups were tested across multiple splits. These tests evaluate predictions within our existing data; tests in fresh cultures are the next step. View full size.

These figures use a separate fit of our J23106 measurements. The Results page reports our earlier model comparison, and the Model page explains the prediction method.

Run the synthetic tutorial

The tutorial uses generated data to demonstrate the software. The figures above use our wet-lab measurements.

Use Python 3.12 in a virtual environment, install requirements.txt, then run this command from the Glow Getter repository root:

python run_simulated_example.py

The command generates example plates, converts them for Glow Getter, fits the all and clean pooled-median curves, and checks saved predictions against the reference results.

Outputs in outputs/simulated-example/ include inputs, the fitted model, predictions, validation scores, a plot and a verification report.

See the Glow Getter installation instructions and example inputs, expected values and verification details.

Code and Data

Both repositories include source code, installation instructions and tests. WellPlotted retains its MIT application license alongside the iGEM starter repository’s Apache 2.0 license. Glow Getter uses Apache 2.0.

Our experimental data are available upon request from the Missouri-Rolla iGEM team.

The public repositories also include generated example data for trying the software locally.