BioBricks, Expression Tools and Protein Design
Our contributions include three registered composite BioBricks for a LuxR/pLuxR–sfGFP reporter system, our software WellPlotted for exploring plate-reader data, the Glow Getter expression-modeling source and J23106 standalone-sfGFP analysis methods, and a record of the Ag43–SmtA fusion design developed in Module 3. We plan to extend expression prediction to sfGFP-tagged targets by collecting measurements and validating predictions for each construct. Teams can build on these parts, methods and design records when planning their own experiments.
BioBricks: LuxR Drivers and an AHL-Responsive Reporter
We registered three composite parts that document the cassette designs for our dual-plasmid reporter system. Two constitutive expression cassettes use different Anderson promoters to drive LuxR, and a separate pLuxR–sfGFP cassette provides the fluorescent readout. The Registry entries share annotated DNA sequences, design rationale and the available experimental observations.
| Registry part | Design and intended reuse |
|---|---|
| BBa_26ULQ051 | pLuxR–sfGFP reporter. A LuxR-responsive promoter controls sfGFP expression, providing a fluorescent readout for testing AHL-dependent regulation with a separate LuxR driver. |
| BBa_26UGQEAI | J23106–LuxR driver. The J23106 promoter drives LuxR expression, providing one promoter choice for investigating how regulator expression affects the reporter system. |
| BBa_264LPKY6 | J23100–LuxR driver. The J23100 promoter drives LuxR expression, providing an alternative cassette design for evaluating the effect of promoter choice. |
All three designs include the RiboJ insulator (BBa_K1679038), ribosome binding site BBa_B0030 and double terminator BBa_B0015. Teams can use the annotated designs to plan their own AHL-responsive circuits and comparisons of LuxR driver promoters, with characterization in their chosen host, vector and culture conditions.
The Registry records preliminary visible fluorescence, providing qualitative evidence of reporter activity in the dual-plasmid system under the described conditions. The next characterization steps are to compare the two LuxR drivers quantitatively, measure a dose-response curve, EC50 and dynamic range, and calibrate protein yield. These measurements and their supporting figures are still outstanding.
Read the Module 2 experimental and analysis account and the Lab Notebook protocols alongside the part-specific Registry documentation.
-
Future tagged targets
Collect a separate dataset for each sfGFP-tagged protein.
-
Plate reader
RFU and optical density at a documented wavelength over time.
-
WellPlotted
Inspect time courses and variation. Prepare model inputs separately.
-
Glow Getter
Fit and evaluate a response after collecting compatible data.
-
Harvest experiments
Test harvest conditions and measure soluble recovery and fusion integrity.
WellPlotted: Exploring the Measurements
We built WellPlotted to compare plate-reader measurements across wells, conditions and time points. It plots fluorescence, optical density and their ratio over time. Our assay measured OD630, so the ratio is RFU/OD630. Ratio plots show means or medians, with optional bars spanning the observed minimum and maximum. Standard RFU and optical-density plots show individual wells or condition means with standard-deviation bars. These bars describe the spread of the input measurements. Confidence intervals and prediction errors would require separate calculations.
WellPlotted reads plate-shaped CSVs whose cells contain promoter|ahl|od|rfu. Users select wells by promoter and AHL labels. Current plots use elapsed hours when every saved round has an acquisition time, and measurement round numbers otherwise. The historical ratio figures used hourly readings starting at zero. The application plots the values supplied in each cell. Before import, users must perform any technical-replicate averaging or background correction appropriate to their analysis and document those steps.
We used these plots to inspect unusual readings, compare variation across runs and choose conditions for harvest experiments. Other teams can use them to check whether a pattern is consistent across runs or driven by a few readings. We have not yet calibrated this fluorescence-to-turbidity signal against recovered protein mass. Calibration and recovery measurements would let us test that relationship.
Glow Getter: A Baseline for Expression Prediction
Glow Getter provides command-line tools for simulation, fitting, database storage, plotting and assay comparisons. Its direct median ratio predictor puts the retained corrected RFU/OD630 curves from each run on a shared time grid, takes the median at each point, and saves that curve. It uses linear interpolation to predict for J23106 expressing standalone sfGFP, at one of six measured 3-oxo-C6-HSL labels and a time from 0–24 hours.
The assay workflow uses fluorescence, instrument-preblanked OD630, time, condition labels and records of each run and well. It averages technical triplicates within each run group and subtracts matching media fluorescence once. Run and well identifiers let us keep measurement groups together during validation. For experimental data, we prepare Glow Getter-compatible records outside WellPlotted, preserving run, well and time information. The supported synthetic example includes a verified JSON handoff. To request a prediction from the fitted model, users supply a supported condition label and time.
Only the 630 nm absorbance setting was available for this assay. Legacy software fields named od600 and plots labelled OD600 use the measured OD630 readings unchanged. We have not established an OD630-to-OD600 calibration. The instrument limitation and supporting reference explains what this means for comparisons with OD600-based studies.
We use the measured-curve method as a baseline for comparison with equation-based models. The earlier screened-default analysis reported 38.61% median and 126.85% mean absolute percentage error in repeated held-out splits of the existing dataset. To verify the report, recalculate the scores with the public code and original experimental inputs, and check the V1–V4 dataset-branch labels against the original outputs. Fresh-culture validation has not yet been completed.
The public repository contains the code and a complete synthetic example with a reference fitted model. To repeat the experimental analysis, use the original assay data, saved exclusions, experimental fitted models, prediction tables, generated predictor pages and reports. Those experimental records are outside the public code release.
This wiki publishes derived figures. The underlying measurement data, fitted experimental models and complete prediction records remain private and local; they are not part of the public release.
A separate DNA-to-protein prototype translates coding DNA and uses protein length, codon adaptation index and molecular weight to scale an sfGFP baseline. It applies the same factor across conditions, leaving their ranking and the best condition unchanged for each target. The reported sfGFP fluorescence errors evaluate the baseline. The transfer has not yet been tested against absolute protein amounts. Calibrate the predictions and compare them with directly measured target yields to evaluate it.
Read the Glow Getter method, model comparisons and validation procedure.
Module 3: A Record of Fusion Design and Revision
We documented two design cycles for a proposed Ag43–SmtA fusion intended to present a zinc-binding domain at the bacterial surface. The first Ag43 prediction showed an apparent overlap between the alpha domain and beta-barrel. This finding prompted a review of the sequence arrangement and closer inspection of individual components alongside the full fusion.
Following feedback from a MilliporeSigma representative, we changed the component order from Ag43 → SmtA → FLAG → OmpA to OmpA → Ag43 → SmtA → FLAG. We established a local RoseTTAFold All-Atom workflow, inspected models in ChimeraX and revisited the sequence with AlphaFold alongside work on the linkers. The procedure records a completed ubiquitin test and a project structure output; the two-cycle image comparison remains qualitative. Expression, surface localization and zinc binding have not yet been tested experimentally.
The contribution includes the design rationale, the two Ag43 model figures and a modeling workflow and troubleshooting record. Teams can use this record to:
- Compare domain arrangements. Examine component and whole-fusion predictions for apparent overlaps and linker placement, and record modeling settings and quantitative structural comparisons.
- Test the revised construct. Build and verify the fusion, then measure expression, surface localization and zinc binding with appropriate controls.
- Explore other binding domains. Use this modular architecture as a design starting point, with separate modeling and experimental evaluation for each replacement.
Compare the two protein model figures, read the design–build–test–learn account, or review the Module 3 modeling findings.
Agar Art
We developed a guide outlining how to host an agar art event, combining scientific outreach with creative engagement. Organizing public engagement activities can be challenging, particularly for teams with limited time or experience planning events, so we documented the complete workflow from preparation through post-event imaging. By sharing the protocol directly, we hope future iGEM teams can adapt the activity to their own facilities, materials, and audiences.
Prior to the Event
Media
Prepare Luria broth agar using:
- 10 g tryptone
- 5 g yeast extract
- 5 g NaCl
- 15 g agar
- 1000 mL distilled water
Combine the components and autoclave for 30 minutes. After the agar has cooled to approximately 50 °C, add chloramphenicol to a final concentration of 50 mg/L. For public events, 150 mm sterile Petri dishes are recommended, although 100 mm and 60 mm plates are also suitable. Prepare plates approximately one week before the event so they are not excessively wet.
Bacterial Strains
Use E. coli MG1655 strains containing chromoprotein plasmids developed by the Forster lab and obtained from Addgene. Maintain the strains on Luria broth agar with 50 mg/L chloramphenicol; the chloramphenicol stock is 50 mg/mL in 100% ethanol. Frozen stocks are kept at −80 °C in 20% glycerol.
Prepare fresh plate cultures approximately three days before the event. Because some plasmids may be unstable, begin with an initial plate from each frozen stock, streak for isolation, and select a pigmented colony to restreak onto a fresh plate approximately three days before the event.
Painting Materials
Use reusable synthetic sable fine-detail brushes, size #0 medium, with wooden handles. Autoclave the brushes in bulk before the event.
Day of the Event
Before Participants Arrive
Suspend fresh pigmented colonies in 0.8% NaCl to an optical density of approximately 0.5–1.0 at 595 nm. Distribute approximately 2 mL of each suspension into sterile 15 mL centrifuge tubes. A typical event uses approximately 11 differently pigmented strains; label each tube by strain or color and give it its own sterile brush. Together, the tubes form a bacterial color palette. Depending on the facility and event arrangement, approximately 2–4 participants can share a palette, with additional palettes prepared for larger groups.
During the Event
Participants trace the outline of their Petri dish on paper, sketch a design inside the circle, and plan their colors before painting. They can place the dish over the drawing to use it as a guide. Participants wear gloves when handling cultures and dishes. Use a separate brush for each color, return each brush to its matching tube, and avoid mixing suspensions on the agar plate to reduce cross-contamination.
Spill Response
If a spill occurs, cover it with a paper towel to limit spreading, apply a suitable disinfectant such as 70% ethanol or 10% bleach, and dispose of contaminated towels and materials in an autoclave waste container.
After the Event
Cleanup
Autoclave the test tubes and paint brushes after the event. Brushes and tubes may be reused after appropriate sterilization.
Incubation
Collect the painted plates and incubate them at 37 °C for approximately 24 hours, with the agar side on top to reduce condensation dripping onto the artwork. Many chromoprotein pigments become visible after approximately 24 hours, but some need an additional 4–5 days to fully develop before photography.
Photography
Place the plates on black felt and use a ring light for illumination. Removing the Petri dish lid during photography can reduce glare and improve image quality.
By documenting the complete workflow—from media and strain preparation to participant safety, incubation, and photography—we aim to provide future iGEM teams with a practical starting point for their own agar art outreach. Teams can adapt the number of bacterial colors, plate sizes, materials, and participant setup to fit their own resources while preserving the core workflow. See the Missouri S&T agar art event examples.
Wet Lab Training
We developed a wet-lab training curriculum to help new iGEM members build the foundational laboratory skills needed to participate confidently in synthetic biology research. Our training progresses from basic media preparation, pipetting, and aseptic technique to bacterial transformation, plasmid purification, and DNA verification.
By documenting these protocols, we hope to provide future iGEM teams with a reusable framework for onboarding members with different levels of laboratory experience. The curriculum can be adapted to each team's available equipment, strains, kits, and established laboratory procedures.
Wet Lab Training Curriculum
Training 1 — Agar Preparation & Pipetting
Goal
Introduce students to agar preparation, plate pouring, pipetting techniques, and the laboratory spaces used by the team.
Materials / Preparation
For 700 mL of agar:
- 7 g tryptone
- 3.5 g yeast extract
- 7 g sodium chloride
- 10.5 g agar
- 700 mL distilled or purified water
Procedure
- Add approximately 700 mL purified water to a 1 L Erlenmeyer flask.
- Weigh and add the tryptone, yeast extract, sodium chloride, and agar.
- Prepare the agar for autoclaving using the liquid cycle.
- Allow the agar to cool after autoclaving.
- Add 700 µL of 50 mg/mL chloramphenicol after autoclaving.
- Mix thoroughly and pour the agar into plates.
While the autoclave cycle is running, students practice using different micropipette sizes with colored water so they can visually confirm the volumes transferred. Students are also introduced to the laboratory spaces and equipment used by the iGEM team.
What Students Learn
Basic media preparation, agar plate pouring, antibiotic addition after autoclaving, micropipette handling, and familiarity with the laboratory environment.
Training 2–3 — Streak Plating & Colony Isolation
Goal
Teach students aseptic streak-plating techniques and how to isolate a single bacterial strain from a mixed pigmented E. coli culture.
Materials / Preparation
Use sterile nutrient agar or LB agar plates, a mixed pigmented E. coli culture, inoculating loops, appropriate loop-sterilization equipment, 70% ethanol and paper towels, a marker or lab tape, a biohazard waste container, and gloves. Prepare a fresh overnight bacterial culture mixture, label plates with media type and date, prepare workstations, and review aseptic technique and laboratory safety.
Procedure
- Gently mix the liquid culture.
- Sterilize and cool the inoculating loop.
- Collect a small amount of the mixed culture.
- Streak the first region of the agar plate.
- Sterilize and cool the loop again.
- Draw a small amount of cells from the first streaked region into the second region.
- Repeat the dilution-by-streaking process for the final region.
- Incubate the plate agar-side up under conditions appropriate for the bacterial strain.
- Examine the plate after approximately 16–24 hours for isolated colonies.
- Select an isolated colony displaying the desired pigment/color.
- Transfer that colony onto a fresh plate.
- Repeat the streak-isolation process.
- Incubate again and examine the resulting colonies for consistent pigmentation.
What Students Learn
Aseptic technique, streak plating, progressive dilution across an agar surface, bacterial colony isolation, and selecting a single strain from a mixed culture.
Training 4 — Plasmid Miniprep
Goal
Teach students how to isolate plasmid DNA from overnight E. coli cultures for downstream cloning, sequencing, or assembly.
Materials / Preparation
Use overnight transformed E. coli cultures, a commercial plasmid miniprep kit, resuspension, lysis, neutralization, wash, and elution buffers (or nuclease-free water for elution), 1.5 mL microcentrifuge tubes, a tabletop microcentrifuge, micropipettes and sterile tips, gloves, 70% ethanol, and appropriate biological and liquid waste containers. Kits such as Qiagen, Zymo, or NEB Monarch may be used; follow the manufacturer's instructions for kit-specific volumes and conditions.
Procedure
- Harvest cells. Label a clean tube, transfer approximately 1.5–3 mL of overnight culture depending on the kit, centrifuge at high speed for approximately 3 minutes, and remove the supernatant appropriately.
- Resuspend. Add the kit's resuspension buffer and fully resuspend the pellet until no visible clumps remain.
- Lyse. Add lysis buffer according to the kit, mix gently by inversion without vortexing, and follow the manufacturer's recommended lysis time.
- Neutralize. Add neutralization buffer, invert until precipitate forms, and centrifuge to pellet cellular debris.
- Bind DNA. Transfer the cleared supernatant to the appropriate spin column, centrifuge, and discard the flow-through.
- Wash. Add wash buffer, centrifuge, and discard the flow-through. Repeat and perform a dry spin if the kit recommends them.
- Elute. Transfer the column to a clean tube and add approximately 30–50 µL of elution buffer or nuclease-free water where compatible with the kit. Allow a brief incubation, then centrifuge to collect the purified plasmid DNA.
After miniprep, store the DNA appropriately, measure its concentration with NanoDrop or Qubit if available, and evaluate samples by agarose gel electrophoresis when appropriate. The purified DNA can be used for cloning, PCR, assembly, sequencing, or other molecular biology workflows.
What Students Learn
Principles of alkaline lysis, differences between plasmid and genomic DNA, spin-column purification, DNA handling, and preparation for downstream molecular biology workflows.
Training 5 — Heat-Shock Transformation
Goal
Teach students how to introduce plasmid DNA into chemically competent E. coli using heat-shock transformation.
Materials / Preparation
Use chemically competent E. coli such as DH5α or TOP10, plasmid DNA, a 42 °C water bath, ice, 1.5 mL microcentrifuge tubes, SOC or LB recovery medium, sterile micropipette tips, micropipettes, sterile spreaders or glass beads, selective LB agar plates, gloves, 70% ethanol, and a biohazard waste container. Thaw competent cells on ice immediately before use; prepare DNA, recovery medium, and selective plates, and review aseptic technique and safety.
Procedure
- Label a cold microcentrifuge tube and keep it on ice.
- Add 50 µL of competent cells.
- Add plasmid DNA.
- Mix gently without vigorous pipetting.
- Incubate the cells on ice.
- Heat shock at 42 °C.
- Immediately return the cells to ice for approximately 2 minutes.
- Add recovery medium.
- Allow the cells to recover under appropriate conditions so antibiotic-resistance genes can be expressed.
- Plate up to 100 µL of transformed culture onto selective agar.
- Spread the culture evenly using sterile technique.
- Allow the liquid to absorb.
- Incubate plates agar-side up under conditions appropriate for the strain.
- Examine the plates for bacterial colonies.
- Select isolated colonies for downstream work.
If colonies are absent, students should consider DNA concentration, competent-cell handling, antibiotic selection, heat-shock conditions, and recovery conditions.
What Students Learn
Handling competent cells, heat-shock transformation, antibiotic selection, aseptic technique, and preparing transformed colonies for downstream experimentation.
Training 6 — Agarose Gel Electrophoresis
Goal
Teach students how to use agarose gel electrophoresis to evaluate DNA samples and support plasmid or insert verification.
Materials / Preparation
Use DNA samples, a DNA ladder, an agarose gel, 1× electrophoresis buffer such as TAE, an electrophoresis chamber, power supply, micropipettes and sterile tips, microcentrifuge tubes, loading dye, appropriate gel-imaging equipment, and designated gel and buffer waste containers. Identify each sample, determine expected fragment sizes, prepare the imaging system, and confirm that the selected stain is compatible with it.
Procedure
- Prepare the gel. Put on required PPE, record sample identities and expected band sizes, place the gel in the chamber, cover it with the appropriate running buffer, and carefully expose the wells.
- Prepare and load samples. Mix each DNA sample with loading dye, load a DNA ladder and the samples in separate lanes, record lane assignments, and use a fresh pipette tip for every sample.
- Run the gel. Confirm buffer level, electrode orientation, and voltage. Run at 90 V for approximately 35 minutes; DNA should migrate from the negative toward the positive electrode. Stop before the tracking dye reaches the end, then switch off and disconnect the power supply before handling the chamber or gel.
- Visualize the gel. Transfer it to the imaging system using the laboratory's approved procedure, capture an image with settings appropriate for the DNA stain, and save or label it with the date, sample identities, and lane assignments.
- Interpret results. Identify the ladder, estimate sample band sizes, compare observed and expected bands, and document absent, additional, or unexpected bands. Gel electrophoresis supports DNA verification but does not necessarily confirm an entire plasmid sequence.
What Students Learn
How DNA fragments separate by size, use of DNA ladders, sample preparation and loading, electrophoresis equipment operation, comparison of observed and expected bands, and the limits of gel-based verification.
By sharing this curriculum, we hope to provide future iGEM teams with a practical starting point for developing new wet-lab members. The individual modules can be used as a sequence or adapted independently based on a team's experience, available equipment, and project needs.
Reusing the Expression Workflow
Other teams can use the same sequence of measurements, plots, predictions and follow-up experiments for their own reporter system:
- Keep the experimental groups identifiable. Record paired fluorescence and optical-density time courses, the measurement wavelength, media controls, condition labels and run identities. Document technical-replicate averaging and the unit represented by each imported cell before summarizing across runs.
- Inspect the measurements before fitting. Prepare compatible WellPlotted CSVs, then compare fluorescence, optical density and their ratio at the documented wavelength. Examine individual runs and their spread, and record the reasons for any exclusions. Prepare Glow Getter's inputs separately and keep a record of where each measurement came from.
- Define and test the prediction task. State how background correction and normalization are calculated. Compare a simple baseline with other methods, keep technical replicates together in validation, and report errors on held-out measurements.
- Test the predicted harvest conditions. Save predictions before collecting fresh data. Compare predicted and measured responses, then use protein-specific calibration and recovery measurements to connect fluorescence with recovered protein mass.
Our Lab Notebook records the experimental procedures. The Results page shows why the earlier analysis pointed to different harvest conditions for fluorescence relative to culture turbidity and total fluorescence.
Next Steps
The repositories linked above contain the code, setup instructions, dependencies and licenses. This wiki shows example plots and the earlier model evaluation. The next verification steps are to check the comparison labels against the original analysis records and test saved predictions on fresh cultures. Fitted experimental models and preparation records are part of the material for repeating that analysis.
We plan to tag additional target proteins with sfGFP, collect measurements for each fusion, and build and validate its model. The current assay predictor estimates normalized fluorescence for J23106 expressing standalone sfGFP. To test protein-yield predictions for other proteins, calibrate the signal, check that each fusion stays intact, and measure protein recovery.
For Module 3, record the full sequence versions, structure files, modeling settings and software versions so others can reproduce the predictions. The linked pages provide the design history, model figures and documented workflow. The sequence and coordinate files still need to be packaged together. Completing model evaluation and collecting expression, localization and zinc-binding measurements will give teams a stronger basis for extending the fusion.