AHL–LuxR Expression Control

We measured standalone sfGFP fluorescence and growth across six AHL conditions to characterize the J23106 LuxR/pLuxR system and identify candidate induction conditions and harvest times for further testing.

System Design

The system uses two plasmids in E. coli DH5α: one carries J23106–luxR, and the other carries pLuxR–sfGFP. The inducer used in the quantitative assays is 3-oxo-C6-HSL, referred to here as AHL.

The view follows the animation. Pause to scroll through the diagram.

LuxR production and AHL-dependent sfGFP expression J23106 on the first circular plasmid drives expression of the luxR gene, producing LuxR protein. AHL binds LuxR. The LuxR–AHL complex binds pLuxR on the second circular plasmid and activates expression of the sfGFP gene, producing fluorescent sfGFP protein. J23106 luxR LuxR plasmid LuxR expression LuxR AHL AHL binding pLuxR binding LuxR–AHL pLuxR sfGFP Reporter plasmid sfGFP expression sfGFP
J23106 drives LuxR expression. AHL-bound LuxR binds pLuxR and activates sfGFP expression.

Expression and Growth

We followed sfGFP fluorescence and culture turbidity over 24 hours across six AHL conditions. After correcting fluorescence for media background, we compared the total fluorescence signal with fluorescence normalized to optical density. This let us examine both the overall reporter signal and the signal relative to culture turbidity. Instrument limitations prevented OD600 measurements, so we used OD630 for normalization.

Our earlier analysis found the highest corrected RFU/OD630 at 10−2, with the strongest normalized response around 21–22 hours. The 10−1 condition had the highest mean total corrected fluorescence at 24 hours. The preferred condition therefore depends on whether we prioritize fluorescence relative to culture turbidity or total fluorescence. Both conditions are candidates for matched harvest experiments to determine which gives the greater recovered sfGFP yield.

J231060–24 hours
Swipe across the plot, or open the full-size figure. Historical assay summary of measured OD630. Left: median media-corrected RFU divided by OD630 rises most strongly for 10 to the minus 2 and 10 to the minus 1. Right: reported final OD630 reductions are 53.5 percent for 10 to the minus 2 and 45.5 percent for 10 to the minus 1.
Figure 1. sfGFP expression and final OD630 reduction from our earlier analysis. Left: median corrected RFU/OD630 across available run groups. Right: mean ± sample SD of matched final OD630 reduction, with seven run labels at 24 h. The values are retained without conversion or recalculation. View full size ↗

Candidates for Harvest Experiments

10−2 · 21–22 h

In that analysis, the median corrected ratio peaked at 69.57 million RFU/OD630 at 22 h. At 21 h it reached 92.3% of that value.

The additional outlier screen moved the peak to 21 h.

24-hour measurements
The table shows the 24-hour measurements before the additional outlier screen. We averaged the technical triplicates within each run, then summarized the runs. We compared final OD630 with uninduced cultures carrying both plasmids.
AHL labelCorrected RFU
mean ± SD, ×10⁶
OD630
mean
RFU/OD630
median, ×10⁶
Final OD630 reduction
mean ± SD, %
Uninduced1.98 ± 2.400.8691.020.0 ± 0.0
10−42.13 ± 2.370.7771.1510.6 ± 2.2
10−316.18 ± 11.120.69822.9920.0 ± 14.4
10−221.10 ± 15.660.40359.5653.5 ± 2.3
10−123.50 ± 14.320.47158.3845.5 ± 10.4
Stock15.66 ± 9.160.66327.7223.3 ± 13.9

Data Analysis and Prediction

We plan to tag each target protein with sfGFP, collect measurements for each construct, and build and test its model using the steps below.

  1. Future tagged targets

    Collect a separate dataset for each sfGFP-tagged protein.

  2. Plate reader

    RFU and optical density at a documented wavelength over time.

  3. WellPlotted

    Inspect time courses and variation. Prepare model inputs separately.

  4. Glow Getter

    Fit and evaluate a response after collecting compatible data.

  5. Harvest experiments

    Test harvest conditions and measure soluble recovery and fusion integrity.

Proposed workflow for sfGFP-tagged proteins. Our current measurements cover J23106 expressing standalone sfGFP, using OD630 because of the plate-reader setting. For each tagged target, we plan to collect measurements, fit and test its model, and compare predictions with recovered protein. We prepare compatible input files separately for WellPlotted and Glow Getter.

WellPlotted

WellPlotted helps us compare fluorescence, OD630 and RFU/OD630 across individual wells or experimental conditions. Our CSV files follow the plate layout, with each cell recording promoter|ahl|od|rfu. We prepare any background correction and technical-replicate averages before import, and keep track of biological replicates in separate records.

Grouped fluorescence and OD plots show the mean with standard-deviation bars. For our pooled data, WellPlotted divides each run’s triplicate mean RFU by its triplicate mean OD, then shows the mean or median of those ratios across runs. Optional min–max bars show the range of readings at each time point.

WellPlotted software and plots

Glow Getter

Glow Getter uses our measurements to estimate corrected fluorescence relative to OD630 at a chosen AHL condition and time. The current model covers J23106 expressing standalone sfGFP, the six AHL conditions we measured, and the first 24 hours. One approach combines the runs into a curve showing the median response over time, then uses straight lines to estimate values between measurement times. We also compared this approach with equation-based models of expression.

We tested the model by asking it to predict readings held back from our existing data. The version using the additional outlier screen had a median absolute percentage error of 38.61% and an average of 126.85%. For the 10−2 condition, these were 40.29% and 207.19%. The larger averages reflect some large prediction errors. Testing the model in fresh cultures is a next step.

The public repository includes the code and a complete example using synthetic data. The fitted models and finished prediction pages for the original experiments are to be uploaded after wiki thaw and presented during judging because of time constraints. Our available data is presented on the wiki.

We are also exploring predictions for other proteins using their DNA sequences. The current prototype adjusts the sfGFP prediction by a factor calculated from the sequence. This changes the predicted amount, but gives every protein the same ranking of AHL conditions. We need calibration and measured protein yields to test whether this approach works, including whether fluorescence predictions match the amount of protein we can recover.

Glow Getter methods and validation

Next Steps

We will test Glow Getter with new cultures and measure how much sfGFP we can recover from the cells. Before starting, we will check the earlier results and save predictions from both versions of the model: with and without the additional outlier screen. We will keep the models and experiment records so the analysis can be repeated.

  1. Repeat the measurements

    We will test all six AHL conditions again using cultures started separately, measuring fluorescence and OD630 every hour for 24 hours. We will start with similar cell densities, keep the timing of AHL addition and reader settings consistent, and confirm the final AHL concentration in each culture.

  2. Compare harvest times

    We will collect separate, matched samples from the 10−2 and 10−1 cultures at 20, 22 and 24 hours. For comparison, we will include cultures without AHL, media alone, and cells carrying empty plasmids.

  3. Measure how much sfGFP we recover

    We will break open the cells and measure the sfGFP that remains dissolved in the extract. We will use known amounts of sfGFP for calibration, include blank samples, and check protein recovery during processing. Recording volumes and dilutions will let us calculate the amount recovered per milliliter of culture and compare it with the fluorescence results.

  4. Try the workflow with other proteins

    We will attach sfGFP to each target protein and repeat the fluorescence and OD630 measurements. WellPlotted will help us inspect the data, and we will train and test a Glow Getter model for each protein. We will then compare fluorescence with direct measurements of the recovered target protein to see how well the tag predicts yield.

Methods

Data preparation and normalization

Our assay record lists seven run labels with hourly measurements from 0–24 h, six cell conditions and media controls, and three technical wells per group. The scripts average the technical wells, subtract matching media fluorescence once, and use instrument-preblanked OD630 without blanking it again.

Normalized output = (mean sample RFU − mean matching media RFU) / mean sample OD630

RFU/OD630 measures fluorescence relative to culture turbidity. Per-cell protein estimates have not been calibrated. The earlier record lists 1,008 eligible run–condition–time groups including hour-zero anchors, five pre-existing run–hour exclusions, and 101 whole triplicate groups flagged by the additional exploratory five-fold screen, equivalent to 303 wells. RFU triggered all of those flags. To check these counts, use the original experimental inputs and screening records, which are outside the public repository. The analysis retains negative corrected RFU and the source readings. See the data-availability statement below.

Validation procedure

The comparison scripts use 50 grouped 80/20 splits. They keep technical triplicates together and hour zero in training. They block shared media measurements associated with hidden targets and apply screening to training data only. Both branches are scored on the same hidden targets. The reported scores have not yet been reproduced against the original experimental data and individual prediction records.

Absolute percentage errors can become large when the observed signal is near zero. Establish biological independence from the culture records before significance testing. Investigate possible contamination in flagged groups with documented experimental observations.

The assay predictor covers J23106 at the six measured AHL labels and 0–24 h. Final culture concentrations have not yet been confirmed from the stock preparation and addition-volume records behind each dilution label.

WellPlotted plots: raw RFU/OD630 Different normalization from Figure 1

The figure notes describe each imported cell as one run’s technical-triplicate mean, prepared before import. WellPlotted divides the supplied raw RFU by OD630 to make these plots, without media subtraction. Technical averaging and background correction are preparation steps outside the app. Figure 1 and the assay-specific Glow Getter analysis use media-corrected fluorescence. The bars span the observed minimum and maximum, a descriptive range with no confidence level attached.

Existing WellPlotted raw RFU per measured OD630 display comparing AHL conditions and media, with median curves and observed run ranges; embedded OD600 labels are legacy text.
Supporting Figure S1. WellPlotted condition comparison. Points show medians of imported cell RFU/OD630 ratios, and bars span the observed minimum and maximum. The older OD600 label denotes measured OD630, with values retained without conversion or recalculation. The figure notes describe technical triplicates averaged before import. The legend identifies dilution preparations. Final culture concentrations have not yet been confirmed from the stock and addition-volume records. Open image to enlarge.
Existing six-panel WellPlotted display of raw RFU per measured OD630, each comparing an AHL condition with media and observed range bars; embedded OD600 labels are legacy text.
Supporting Figure S2. WellPlotted condition panels. Colored lines show median raw RFU/OD630, and dashed gray lines show the media reference alongside each condition without subtraction. The older OD600 label denotes measured OD630, with the original values retained without conversion.
Analysis record

Our analysis record is dated 20 October 2026. It lists outputs/competition_summary_2026_10_20 and OD600_rebuilt_versions/summary.csv as output locations. These original filenames refer to readings taken at 630 nm. The V1–V4 dataset branches and model-search rankings have not yet been verified against those original outputs. These experimental datasets, results, fitted models and generated predictor pages are outside the public release. The included synthetic example has its own reference fit and expected outputs.

This wiki publishes derived figures. The underlying measurement data, fitted experimental models and complete prediction records remain private and local; they are not part of the public release.

We used the 630 nm setting because it was the only one available. The software’s OD600 names retain the measured OD630 values unchanged. Paired calibration and checks of the thresholds used at 600 nm have not yet been completed. See the instrument limitation and notebook setting.

Measurement-method references: Balleza et al. (2018), Ceroni et al. (2015), Csibra and Stan (2022), Lord et al. (2020), and Stevenson et al. (2016).

References

  • Balleza, E., Kim, J. M., & Cluzel, P. (2018). Systematic characterization of maturation time of fluorescent proteins in living cells. Nature Methods, 15(1), 47–51. https://doi.org/10.1038/nmeth.4509
  • Ceroni, F., Algar, R., Stan, G.-B., & Ellis, T. (2015). Quantifying cellular capacity identifies gene expression designs with reduced burden. Nature Methods, 12(5), 415–418. https://doi.org/10.1038/nmeth.3339
  • Csibra, E., & Stan, G.-B. (2022). Absolute protein quantification using fluorescence measurements with FPCountR. Nature Communications, 13, Article 6600. https://doi.org/10.1038/s41467-022-34232-6
  • Lord, S. J., Velle, K. B., Mullins, R. D., & Fritz-Laylin, L. K. (2020). SuperPlots: Communicating reproducibility and variability in cell biology. Journal of Cell Biology, 219(6), Article e202001064. https://doi.org/10.1083/jcb.202001064
  • Stevenson, K., McVey, A. F., Clark, I. B. N., Swain, P. S., & Pilizota, T. (2016). General calibration of microbial growth in microplate readers. Scientific Reports, 6, Article 38828. https://doi.org/10.1038/srep38828