Before starting any wet-lab experiments, all team members involved in laboratory work were required to complete a comprehensive lab safety induction. The induction covered essential topics such as the correct handling and disposal of chemicals, safe transfer procedures between labs – including the use of double containment – and designated pathways when moving equipment between floors to maintain containment of organisms and chemicals. The team also reviewed procedures for responding to fire alarms. Upon completion, each participant signed a document to confirm their understanding of the safety protocols.
Proper PPE and organisation
To maintain a high standard of safety in the laboratory, each team member was provided with appropriate Personal Protective Equipment (PPE), including an individual lab coat, safety goggles, nitrile gloves of the correct size, and protective gloves when handling hot glassware (Fig. 1). We strictly adhered to the dress code – all members wore long pants and closed-toe shoes. Team members were also familiarised with the locations of all safety equipment, such as PPE storage areas for restocking and the placement of eye-wash stations. Recognising that safety is closely linked to organisation, we kept workspaces clean and orderly at all times to minimise the risk of chemical spills and promote efficient lab operations (Fig. 2).
Figure 1. Protective gloves for handling hot glassware
Figure 2. Organised and clean bench
Proper waste disposal and clean-up
All laboratory waste was disposed of following strict protocols to ensure safety and compliance. Chemical waste, pipette tips used for chemicals, and used nitrile gloves were placed in orange bins (Fig. 3), while glass pipettes and other sharp objects were discarded in designated sharps bins (Fig. 4). Biowaste – including used Petri dishes with bacterial colonies, tubes used for bacterial cultures, and pipette tips exposed to bacteria – was collected in grey biowaste bins (Fig. 5). Once any waste bin was full, it was securely sealed with a plastic tag and transferred in a blue double-containment box for autoclaving (Fig. 6). To promote sustainability, used pipette boxes were placed in recycling bins (Fig. 7). All bacterial cultures were neutralised with Virkon before disposal (Fig. 8), and contaminated glassware was disinfected, rinsed, and then placed in a grey box for central cleaning (Fig. 9).
Figure 3. Orange bin
Figure 4. Sharps bin
Figure 5. Grey biowaste bin
Figure 6. Blue double-containment box for waste bags
Figure 7. Recycling bin for pipette tip boxes
Figure 8. Virkoning the dirty glassware
Figure 9. Grey box for dirty rinsed glassware collection
Equipment training
All wet-lab members received thorough training on the safe and effective use of laboratory centrifuges, specifically the 18K centrifuge (Fig. 10) for pre-culture tubes and the J6 centrifuge (Fig. 11) for 1 L culture samples. The training emphasised proper balancing techniques: we paired and weighed tubes on precise scales to ensure equal mass. If discrepancies were detected, deionised water was added to achieve accurate balance (Fig. 12). We were also instructed on the correct placement of tubes within the centrifuge and the importance of securely fastening the lid using a T-wrench to maintain operational safety (Fig. 13).
Figure 10. 18K centrifuge for spinning pre-culture tubes
Figure 11. J6 centrifuge for spinning the 1 L cultures
Figure 12. Balancing the tubes
Figure 13. The use of a T-wrench for fastening the lid
Containment
Biological contaminants
We are mainly working with E. coli cells throughout our project, making the disposal and treatment of bacteria contaminated wastes critical for containing the biological wastes. As we are genetically engineering E. coli cells that enable them to produce recombinant proteins, accidental release of these modified organisms into the environment may contaminate the gene pool of wild type organisms.
To prevent contaminating the lab environment and releasing genetically modified E. coli, all experiments involving bacteria were either conducted inside a biosafety cabinet with an air filtration system (Fig. 14), or next to a bunsen burner. After finishing using the biosafety cabinet, the bench would be disinfected with 75% ethanol, followed by UV light (Fig. 15). All of the biologically contaminated wastes are properly disinfected, autoclaved, and disposed properly (see Proper waste disposal and clean-up section)
Biological contaminants text
Figure 14. Opened biosafety cabinet for drying plates
Figure 15. Biosafety cabinet disinfected by UV light
Chemical handling
Fume hood
Our project involves expressing functional prions that aggregate into inclusion bodies in vivo, therefore, denaturing protein purification was used to obtain our proteins of interest. This process uses guanidine hydrochloride - a strong denaturant that unfolds the protein structure to prevent aggregation and allow resin binding. The powerful denaturing property of guanidine hydrochloride causes strong irritation of skin when contacted without gloves, so solid guanidine hydrochloride is weighed inside a fume hood with proper PPE.
Staining and destaining of SDS-PAGE gels are also conducted inside a fume hood as both the staining and the destaining solutions contain acetic acid, in which exposure without protection can cause corrosive damages. Therefore, acetic acid is measured inside the fume hood for preparing these buffers. The stain used for SDS-PAGE visualisation is coomassie blue, which causes irritation of the respiratory tract when inhaled and is measured inside the fume hood as well (Fig. 16, Fig. 17, Fig. 18).
Figure 16. Set-up of the fume hood
Figure 17. Staining SDS-PAGE inside the fume hood
Figure 18. Destaining SDS-PAGE inside the fume hood
Liquid nitrogen
Liquid nitrogen is used extensively in our project for fast freeze of proteins before lyophilisation and preparation of the electron microscope. However, it is associated with the risk of asphyxiation and cold burn if not handled properly. Our team received professional training on transferring liquid nitrogen from the large tanks to bottles for experimental use. Eye protection is used to prevent splashes, and cryogenic gloves are worn for insulation. Basic PPE such as lab coats are also used (Fig. 19 and Fig. 20)
Figure 19. Pouring liquid nitrogen from the tank
Figure 20. Protective equipment for handling liquid nitrogen