What the predictions recover
Each mutant was predicted as a trimer, five models per design, covering the five N-terminal candidates as single mutants and the five double-cysteine designs. A trimer is the smallest assembly containing a genuinely interior subunit: the middle chain is buried on both faces, as a monomer in the shaft of a mature fibril is, while the two outer chains model the fibril termini.
Across nine of the ten designs the rise is 4.70–4.79 Å per rung, approximately 9.5 Å per monomer. That is the spacing expected of a parallel in-register β-sheet, and it is indistinguishable from the 4.70 Å of the wild-type control. The architecture is therefore recovered from sequence alone, which supports both the fold and the mutations being tolerated within it.
A natural second test is the i ↔ i+36 pseudo-repeat register described by Wasmer et al. (2008), asking, for each residue, whether its nearest neighbour in the adjacent chain lies 36 residues away. We computed it and do not quote it, because it does not discriminate. In every correctly stacked prediction, wild type included, roughly half the residues report an offset of 0 and roughly half ±36, and which of the two wins the count is decided by two or three residues out of 72. Worse, the one job that failed scores highest on the measure, because its collapsed monomers sit trivially at offset 0. The rise is the measure to read.
The exception is V239C/T260C, which gives a rise of 2.4 Å per rung and a core pLDDT of 63. Its monomers did not stack in the native architecture, so that job is excluded from all subsequent analysis rather than interpreted.