On this page

Project Search

0 results

Wet Lab · Results

Results

What do our biological measurements establish?

Abstract

We followed the progression from odor-related fluorescence in the fly brain to construct preparation, reporter expression and stimulus-associated fluorescence in engineered HEK293 cells.

Three light-sheet recordings show regional signals during odor delivery. Colony plates and DNA gels document construct preparation; microscopy fields and two kinetic odor assays show reporter-associated fluorescence alongside their controls.

Results at a glance

  1. 01Fly brain imaging
  2. 02Colony plates
  3. 03DNA electrophoresis
  4. 04Transfection efficiency
  5. 05Odor testing

01 · Biological inspiration

Fly brain imaging

AeroSense approaches odor sensing as a pattern distributed across channels. We examined that principle by following regional fluorescence during odor delivery. TH-GFP reveals labeled structures; GH146-GCaMP6f records regional fluorescence across seven odor presentations. The two GH146 recordings come from the same fly. Figure 1 defines the measured regions; the recordings show their image context, and Figure 2 compares regional time courses with whole-image means.

TH-GFP and both GH146-GCaMP6f imaging fields with measured regions and one shared posterior-to-anterior direction arrow
Figure 1. Measured regions on the original images. All three images run from posterior at left to anterior at right. ROI names describe image positions; the colors match the curves.
First frame: TH-GFP recordingWatch on iGEM Video Universe ↗
Video 1. TH-GFP · isopentyl acetate, 3-octanol and 4-methylcyclohexanol.
First frame: GH146-GCaMP6f recording with three odorsWatch on iGEM Video Universe ↗
Video 2. GH146-GCaMP6f · isopentyl acetate, 3-octanol and 4-methylcyclohexanol.
First frame: GH146-GCaMP6f recording with four odorsWatch on iGEM Video Universe ↗
Video 3. GH146-GCaMP6f · ethyl propionate, benzaldehyde, 2-heptanone and valeric acid.
Complete 132 second ΔF/F₀ comparison of TH-GFP and both GH146-GCaMP6f odor panels
Figure 2. Complete ΔF/F₀ time courses. TH uses bleaching-corrected fluorescence; each curve is normalized to its own 8–16 s mean. Blue bands mark odor delivery. Solid curves are image regions; black dashed curves are whole-image means.

In the shared three-odor sequence, the middle and upper GH146 regions showed mean local ΔF/F₀ changes of +1.73% to +2.67%, while the right region ranged from −0.61% to +0.48%. Across the four additional odor windows, regional means ranged from −1.00% to +1.56%. Figures 3 and 4 align each odor window to stimulus onset and its own pre-odor baseline, allowing the regional patterns to be compared locally.

TH-GFP and GH146-GCaMP6f regional ΔF/F₀ aligned to the same three odor presentations
Figure 3. Shared odors, aligned to stimulus onset. Each panel uses its own pre-odor baseline and vertical scale.
GH146-GCaMP6f regional ΔF/F₀ during ethyl propionate, benzaldehyde, 2-heptanone and valeric acid
Figure 4. Four additional odors in GH146-GCaMP6f. The same local-baseline calculation is used for each odor; the valeric-acid recording ends at stimulus offset.

02 · Colony plates

Colony plates

The engineered-cell experiments required twelve vector constructs. We selected isolated colonies for plasmid preparation and subsequent DNA checks. Figures 5–7 show colony plates from this twelve-vector set; the markings identify the colonies selected for follow-up.

Discrete colonies were available alongside denser growth regions, allowing individual candidates to be selected for plasmid preparation.

Engineered cell experiments

DNA electrophoresis

Before transfection, we checked whether DNA was detectable in the plasmid preparations and whether paired samples showed comparable migration patterns. Figure 8 groups the undigested preparations by construct label beside the Bio-1Kb™ Mass DNA Ladder (PROTECH).

DNA is visible in all 24 sample lanes. The two lanes for each of the twelve construct labels show similar migration patterns within each pair.

Gel A: PROTECH Bio-1Kb Mass DNA Ladder, two ORCO lanes and two Or67b lanes.Gel B: PROTECH Bio-1Kb Mass DNA Ladder, paired Or35a, Or85b and GCaMP6f lanes.Gel C: PROTECH Bio-1Kb Mass DNA Ladder, paired Or22a and Or59b lanes.Gel D: PROTECH Bio-1Kb Mass DNA Ladder at each end, with paired Or7a, Or67a, Or19a, Or42a and Or98a lanes.
Figure 8. Undigested plasmid preparations with paired lanes for each construct. PROTECH Bio-1Kb™ Mass DNA Ladder sizes are marked in kb; the 3 kb reference is bold. Panel A groups the closely spaced 10 and 8 kb bands. Open a panel for full resolution.

Marker labels describe linear DNA fragments; undigested plasmid migration also depends on conformation.

04 · Transfection efficiency

Assessing transfection

The construct design pairs mCherry with the OR cassette and GCaMP6f with the calcium-reporting module. Before testing fluorescence kinetics, we examined the reporter channels alongside cell density and the nuclear reference. Figure 9 shows matched brightfield, DAPI, RED and GREEN images from each field.

The dataset contains 25 fields across 12 conditions: n = 1–3 technical fields per condition, N = 1 independent experiment. Select a condition and field to inspect its four matching channels.

blank (no transfect) · 3 fields acquired · technical observations

Blank control field 1, all four microscopy channels
Figure 9. Blank control, field 1 of 3. Technical field, not a biological replicate; original scale bars retained. Same-field channels. Display windows: brightfield and DAPI 0–255, GREEN 0–120, RED 0–180.

Choose a condition and inspect its acquired fields.

Fluorescence around resolvable DAPI objects

We quantified the fraction of eligible DAPI objects exceeding the blank-derived reporter threshold in each channel. Figure 10 shows individual technical fields and the pooled fraction, calculated as total positive objects divided by total eligible objects. The complete counts and denominators are retained in Supplementary data, Table 1.

Each field's red, green and dual-positive fraction among eligible DAPI objects, with pooled fractions marked separately
Figure 10. Every supplied field is shown. Dots are technical field observations; black marks are positive-object totals divided by eligible-object totals. No biological-replicate confidence intervals or significance tests are inferred.

The blank yielded 1/170 eligible objects above each channel threshold. The mCherry-free Orco-only condition yielded 0/342 RED-positive and 24/342 GREEN-positive objects, separating the two reporter channels within this image set.

05 · Odor testing

Odor testing

We followed fluorescence over time in ten OR + ORCO conditions, ORCO-only cells and the control condition specified for each test. Figures 11–14 show Test 1 and Test 2 time courses, condition comparisons, control-referenced maps and the Test 2 VUAA1-referenced map.

Test 2 contains 72 wells and 1,440 readings across ten OR + ORCO conditions, ORCO-only cells and the blank control. Each construct × stimulus has one well.

VUAA1 is an established Orco agonist used in heterologous receptor assays. [2] [3]

VUAA1 and control time courses in Test 1 and Test 2
Figure 11. Normalized VUAA1 and control time courses in Test 1 and Test 2. Test 1 uses each well’s paired baseline; Test 2 uses the first post-addition reading. Each trace represents one well, and panels have independent vertical scales.

In Test 2, ten of twelve VUAA1 time courses end above their first reading, while eleven conditions have a positive corrected change. Or7a + ORCO and the blank control end lower; a positive corrected score does not necessarily mean that the measured trace rises.

VUAA1 signals and control behavior

Figure 12 compares all twelve conditions. In Test 2, corrected changes are +36.67 pp for Or98a + ORCO, +18.69 pp for ORCO only and −0.11 pp for the blank control.

All twelve conditions in Test 1 and Test 2
Figure 12. All twelve conditions. Test 1 shows peak test excursions (%), while Test 2 shows corrected changes (pp); these test-specific summaries are displayed separately.

Test 1 includes a large positive buffer-control signal, whereas the twelve Test 2 DMSO-control scores range from −1.79 to −0.31 pp. The corrected values are descriptive results from individual wells, rather than activation thresholds.

Responses relative to assay controls

Figure 13 adds the six-stimulus Test 2 screen to the original response maps. Test 2 corrected VUAA1 values range from −0.11 to +39.23 pp. Valeric acid spans −0.77 to +8.17 pp; the other three odor rows range from −2.06 to +1.36 pp. We show vehicle subtraction and the blank adjustment separately so that control-dependent changes remain visible.

Corrected response maps from both odor assaysVehicle and blank control contrasts from both assays
Figure 13. Response maps with Test 1 on the left and Test 2 on the right, receptors in rows and stimuli in columns, on a shared −60 to +60 pp scale. The first ten receptor labels denote OR + ORCO; hatched Test 1 isopentyl-acetate cells remain excluded, and separate-well control subtraction does not establish receptor specificity.

Responses relative to each construct’s VUAA1 reference

Figure 14 compares each Test 2 odor response with the VUAA1 reference for the same construct, after subtracting its DMSO control. Construct-specific VUAA1 referencing has been used in heterologous receptor assays. [3]

Test 2 odor responses normalized to the DMSO-subtracted VUAA1 response of each construct
Figure 14. Test 2 VUAA1-referenced responses, with DMSO set to 0 and VUAA1 to 1 for each construct and one well per condition; The ten tuning OR conditions coexpress ORCO. Orange cells retain negative ratios; †Or7a has a small VUAA1 reference (2.19 pp), making its ratios particularly sensitive to that reference.

post-addition fluorescence dynamics and the DoOR reference

A separate analysis of the retained post-addition fluorescence readings compares four odorant profiles across ten OR + ORCO conditions with the DoOR receptor database. The two views below place measured, vehicle-referenced fluorescence changes beside the receptor patterns used to inform our decoding work. The analysis uses the experimenter-confirmed channel labels and source-cell mapping in the post-addition fluorescence workbook; it reuses the Test 2 post-addition fluorescence records.

Figure 15 shows distinct profiles across the four odorants. Valeric acid has the largest positive contrast, +6.97 percentage points (pp) for the supplied Or22a channel, followed by +3.02 pp for Or67a and +2.98 pp for Or35a. Isopentyl acetate is highest for Or42a (+1.35 pp), while pentyl acetate is highest for Or67a (+1.74 pp). Values retain their signs and are shown on a common fluorescence scale.

Four odorant profiles across ten receptors: post-addition fluorescence changes minus matched DMSO, alongside DoOR consensus minus receptor spontaneous firing rate
Figure 15. post-addition fluorescence odorant-minus-DMSO contrasts (top, pp) and DoOR consensus minus receptor-specific spontaneous firing rate, SFR (bottom, DoOR units). The scales differ between panels. Each experimental condition has one well; all ten tuning OR conditions coexpress ORCO. The grey cell is the missing Or42a–valeric acid DoOR value. The fluorescence contrast compares early and late three-reading means; Experiments gives the calculation. DoOR-derived material: Münch and Galizia, 2016, CC BY-SA 4.0.

The across-receptor comparisons show weak positive association with DoOR for 2-heptanone (Pearson r = +0.317; Spearman ρ = +0.406), isopentyl acetate (r = +0.325; ρ = +0.442) and valeric acid (r = +0.211; ρ = +0.283). Pentyl acetate is close to zero (r = −0.002; ρ = +0.006). Thus, the experimental profiles share part of the database ordering for three odorants, with agreement depending on the odorant.

Per-odorant scatter plots comparing post-addition fluorescence contrasts with DoOR minus spontaneous firing rate, with Pearson and Spearman correlations
Figure 16. Each point is one receptor–odorant pair. Correlations are calculated separately within each odorant: n = 10 receptors, except valeric acid (n = 9 because Or42a is missing from DoOR). ORCO-only and blank controls are retained in the analysis package and excluded from these tuning-OR correlations. Values use the supplied three-point-window calculation. DoOR-derived material: Münch and Galizia, 2016, CC BY-SA 4.0.

Discussion

The Test 2 VUAA1 time courses show within-acquisition rises in most receptor conditions. After subtracting each well’s F0 change, eleven conditions are positive and the blank value is close to zero. Test 1 and Test 2 use different control designs and calculations, so they provide separate observations rather than interchangeable estimates.

In Test 1, the ORCO-only VUAA1 well showed an 11.86% fluorescence excursion, compared with 0.98% in the untransfected well. The 35.25% excursion in a buffer-only well shows why a rise alone cannot establish ligand-specific activation.

Colony growth and undigested-plasmid migration document preparation, but neither establishes insert sequence or construct identity. Separate RED and GREEN images likewise do not establish receptor localization or channel function.

GCaMP6f is a calcium-sensitive indicator. Its resting fluorescence is not a constitutive, calcium-independent measure of transfection. Low green signal may reflect indicator state, expression, acquisition sensitivity or background, and a single endpoint cannot distinguish these explanations. Functional interpretation requires time-resolved, controlled stimulation. [1]

The fixed-cell screen at 44–48 h and Test 1 at approximately 72 h are separate pre-selection records. Their position in the workflow does not establish that they came from the same cell batch.

The microscopy fractions all come from one experiment. Uneven field coverage, within-field clustering and density exclusions prevent ranking receptor conditions as independently replicated estimates of transfection or expression. Blank and Orco-only controls provide within-study context, but do not supply biological replication.

Test 1 used a laboratory plate reader. These results characterize the biological assay; they do not establish the performance of the assembled AeroSense reader.

Control comparisons use separate single wells and describe fluorescence patterns rather than receptor-specific activation. Test 2 includes a DMSO reference; Test 1 lacks a matched vehicle control. Unrecorded gain, cell-state variation and dilution-only concentration records limit interpretation. Vehicle-matched tests at documented doses in independent cultures are needed to separate these effects.

The post-addition fluorescence comparison provides an exploratory connection between the cell measurements and the DoOR reference used in Model. Its metric is C = Dodor − DDMSO, based on early and late post-addition fluorescence means; it is distinct from the F0-subtracted S values and VUAA1-referenced N ratios above. Positive C can represent a smaller decline than DMSO, rather than a rising trace. The experimenter confirmed matched DMSO fraction and addition volume, while gain consistency and addition-to-first-read delay remain unconfirmed. The experimenter-confirmed post-addition fluorescence channel map supersedes the earlier Test 2 receptor labels; the underlying fluorescence readings are unchanged.

The first three odorants show weak positive cross-platform agreement, while pentyl acetate does not. Leaving one receptor out gives Pearson ranges of +0.080 to +0.502, +0.198 to +0.488, +0.169 to +0.550 and −0.284 to +0.182, respectively. These ranges describe sensitivity to receptor selection, not confidence intervals. One well per condition, shared DMSO references and different measurement platforms limit transfer claims; timepoints do not increase biological n. This reanalysis does not provide an independent experimental validation, receptor-specific activation test or demonstrated fluorescence-to-odor classifier.

Conclusion

The expression screen detected reporter-associated fluorescence above the blank-derived threshold in resolvable DAPI objects. RED-positive fractions across the OR + ORCO conditions ranged from 0.7% to 16.5%; dense overlap prevents interpreting these fractions as whole-culture transfection efficiency.

The odor assays provide time-resolved evidence of VUAA1-associated fluorescence. In Test 2, F0-subtracted VUAA1 changes are +36.67 pp for Or98a + ORCO, +17.52 pp for Or85b + ORCO, +29.46 pp for Or35a + ORCO, and +18.69 pp for ORCO only, compared with −0.11 pp in the blank control. The control maps and retained raw records make these observations inspectable.

The post-addition fluorescence reanalysis adds odorant-dependent comparisons with DoOR: weak positive across-receptor associations for three odorants and near-zero association for pentyl acetate. The shared reference makes the measured profiles and their correspondence to the decoding database directly inspectable.

Data availability

Research archive: Zenodo · DOI: 10.5281/zenodo.23469212. Public release pending.

Code, analysis scripts and reusable documentation are published in the official iGEM GitLab repository. Archive availability: Research archive availability.

Source data and documents

Test 2 odor-assay archive

The complete Test 2 raw-data package is prepared locally for Zenodo; no public deposit has been verified. The package contains twelve unchanged XLSX exports, checksums, 1,440 observations with source-cell references, 72 corrected summaries, matched-window sensitivity values and reproducible analysis scripts. The earlier mean-ratio calculation is retained only as a secondary audit metric. All corrected values are available in the supplementary tables.

Test 2 correction and VUAA1-reference source Corrected Test 2 changes · CSV Corrected Test 2 observations · CSV Corrected Test 2 summary · JSON Corrected Test 2 VUAA1-referenced scores · CSV Corrected Test 2 well summary · CSV

Complete odor-assay curves

The complete-curve analysis preserves the original acquisition boundaries and checks every plotted reading against the canonical exports. The scalable figure, chart-data tables and endpoint audit accompany the single reproducible builder.

Full-size vector figure · SVG · All 5,280 raw curve readings · CSV · Test 2 referenced time courses · CSV · Figure 14 endpoint checks · CSV · Test 1 peak-metric checks · CSV · Original acquisition source checksums · JSON · Original complete-curve analysis source · Original complete-curve reproduction guide

Test 1 kinetic assay

Test 1 source and archive — Test 1 analysis source — GitLab · Full raw-data archive availability — the complete archive preserves 32 exact instrument exports, filename map, source analysis, tidy data, independent calculations, English figures and executed methods. The numerical analysis uses only Python’s standard library. Original inputs are preserved, including the source report whose claims are audited.

3,840-row tidy time series — archive availability · 96-well summaries · Analysis script — GitLab · Metadata and provenance · Test 1 executed methods · PDF · Reproduction guide — GitLab

Numerical audit · Transparent QC table · QC label audit

Endpoint microscopy

The dataset contains 100 individual-channel images across 25 fields, 12 pre-existing merges and the experimental workbook. Individual channels are 2592 × 1944 pixels; fluorescence images are 8-bit pseudocolored exports. Measurements use the individual channels and the condition and field identifiers in the supplied source folders. The WL-MIC-01 reanalysis retains the original acquisition and single-experiment scope. Acquisition metadata, processing parameters and source-file checksums accompany the analysis.

Download pixel-identical WebP image channels by condition and field

Original TIFF files and metadata: see the Original TIFF archive availability. The iGEM links below provide pixel-identical WebP images.

Table 6. Downloadable microscopy-analysis files and provenance records, including object measurements, field and condition summaries, image diagnostics, source hashes and reproducibility packages. Cloning photographs and the source plate workbook are listed separately from measured assay outcomes.
RecordContentsAccess
Reproducible control auditFisher/Holm diagnostics, nominal Wilson limits, three blank holdouts, area/object agreement, exact input hashes and source scriptFiles — Microscopy analysis source — GitLab · Microscopy analysis source — GitLab · Python — GitLab · CSV
Analysis packageScripts, parameters, source hashes, CSV tables and the analysis report; pixel-identical WebP images are linked separatelyBrowse files — Microscopy analysis source — GitLab · Microscopy analysis source — GitLab
Object measurementsEvery segmented object ≥200 pixels, inclusion/exclusion reason, scores and threshold callsCSV — archive availability
Per-field resultsAll 25 field denominators, positive counts and retained areaCSV
Per-condition resultsPooled fractions and threshold sensitivityCSV
Image-export diagnostics100 channel records, blank-relative area, clipping, medians and large blue regionsCSV
Source manifestOriginal filenames, bit depth, TIFF tags and SHA-256 hashesJSON
Analysis reportMethods, tables, threshold sensitivity and interpretation in a standalone appendixMicroscopy analysis report · PDF
DNA electrophoresisAnnotated panels, pixel-identical WebP gel images, lane maps and reproducible processing settingsAnnotated panels · Source gels and lane maps · Processing record · Source script — GitLab
Cloning photographsThree unchanged source photographs; filenames and SHA-256 hashesJSON
Source workbookOriginal plate-layout and reagent-calculation records; not proof of execution or assay outcomesXLSX — archive availability
Light-sheet imagingSource measurements, ROI archives, movies, physical timestamps and reproducible plotsGH146 numerical dataset — archive availability · TH numerical dataset — archive availability

Figure files

post-addition fluorescence dynamic comparison

The complete archive includes the 1,080-reading source workbook with cell references, all 72 dynamic summaries, 48 vehicle contrasts, DoOR provenance, missing-value records and leave-one-receptor-out checks. Analysis code, validation code and reproduction guide — GitLab. The complete data package is retained in the prepared research archive; public deposit status is described in the archive availability record. The existing reference-pattern backend Pearson function independently reproduced the four reported coefficients.

Supplementary data

Microscopy counts and fields

Pooled reporter-positive fractions

Table 1. Reporter-positive fraction among resolvable DAPI objects. Counts are pooled across technical fields. These are not whole-population transfection efficiencies.
Image labelFieldsRED+ / eligibleGREEN+ / eligibleBoth / eligibleDAPI foreground retained
blank (no transfect)31/170 (0.6%)1/170 (0.6%)1/170 (0.6%)9.1%
ORCO only30/342 (0.0%)24/342 (7.0%)0/342 (0.0%)19.6%
Or7a+ORCO221/192 (10.9%)3/192 (1.6%)1/192 (0.5%)16.2%
Or19a+ORCO225/242 (10.3%)1/242 (0.4%)0/242 (0.0%)16.2%
Or22a+ORCO28/189 (4.2%)1/189 (0.5%)1/189 (0.5%)9.9%
Or35a+ORCO228/200 (14.0%)11/200 (5.5%)8/200 (4.0%)10.2%
Or42a+ORCO218/263 (6.8%)4/263 (1.5%)1/263 (0.4%)22.8%
Or59b+ORCO238/230 (16.5%)3/230 (1.3%)2/230 (0.9%)21.1%
Or67a+ORCO217/161 (10.6%)6/161 (3.7%)4/161 (2.5%)10.6%
Or67b+ORCO214/193 (7.3%)2/193 (1.0%)2/193 (1.0%)9.5%
Or85b+ORCO125/156 (16.0%)8/156 (5.1%)7/156 (4.5%)18.9%
Or98a+ORCO22/286 (0.7%)2/286 (0.7%)2/286 (0.7%)20.2%

Shared record WL-MIC-01 · acquisition provenance · measurement pipeline and calibration audit.

Images were acquired 44–48 h after transfection, before G418 selection, with the same exposure within each fluorescence channel across conditions and blank calibration. All 25 fields come from one supplied transfection study, without independent biological repeats. The control comparison below is an exploratory calculation on the selected objects; it cannot establish a reproducible difference between cultures.

Open every field directly

We excluded ambiguous connected regions instead of forcing a cell count through the dense aggregates. The condition table gives the number of positive objects and the denominator explicitly. “DAPI foreground retained” is the eligible objects’ share of segmented blue area, not the fraction of all cells or nuclei retained. The low retained area warns that these estimates sample the easier-to-segment portion of each field.

Density and thresholds matter

The images contain broad connected DAPI regions and clipping at the maximum exported value. Even a sharp edge around a fluorescent patch can contain several overlapping nuclei. Retaining a small, isolated subset avoids inventing divisions within those clusters, but introduces a selection bias. The excluded regions remain visible in every overlay.

Threshold choice also matters. For Or98a + Orco, the RED-positive fraction changes from 30.8% at the less stringent blank P95 threshold to 0.7% at P99. We use the conservative P99 rule as the primary analysis and report the full sensitivity table.

All per-field object counts and fractions

Table 2. Per-field endpoint microscopy results for all 25 images, retained separately by condition. RED+ and GREEN+ counts and percentages use the eligible DAPI-object denominator in each field; retained DAPI foreground indicates how much area survived the segmentation filter. Fields are not independent biological replicates.
ConditionFieldEligible DAPI objectsRED+GREEN+DAPI foreground retained
blank (no transfect)1361 (2.8%)1 (2.8%)5.3%
blank (no transfect)2720 (0.0%)0 (0.0%)12.4%
blank (no transfect)3620 (0.0%)0 (0.0%)11.4%
Or19a+ORCO11149 (7.9%)1 (0.9%)15.7%
Or19a+ORCO212816 (12.5%)0 (0.0%)16.7%
Or22a+ORCO11377 (5.1%)0 (0.0%)14.8%
Or22a+ORCO2521 (1.9%)1 (1.9%)5.8%
Or35a+ORCO110014 (14.0%)7 (7.0%)7.1%
Or35a+ORCO210014 (14.0%)4 (4.0%)17.1%
Or42a+ORCO11055 (4.8%)1 (1.0%)27.7%
Or42a+ORCO215813 (8.2%)3 (1.9%)20.2%
Or59b+ORCO115112 (7.9%)0 (0.0%)20.9%
Or59b+ORCO27926 (32.9%)3 (3.8%)21.4%
Or67a+ORCO113213 (9.8%)6 (4.5%)12.1%
Or67a+ORCO2294 (13.8%)0 (0.0%)7.6%
Or67b+ORCO17813 (16.7%)2 (2.6%)9.6%
Or67b+ORCO21151 (0.9%)0 (0.0%)9.5%
Or7a+ORCO18815 (17.0%)2 (2.3%)15.1%
Or7a+ORCO21046 (5.8%)1 (1.0%)17.4%
Or85b+ORCO115625 (16.0%)8 (5.1%)18.9%
Or98a+ORCO11402 (1.4%)2 (1.4%)30.5%
Or98a+ORCO21460 (0.0%)0 (0.0%)15.2%
ORCO only11200 (0.0%)8 (6.7%)23.2%
ORCO only21410 (0.0%)11 (7.8%)22.5%
ORCO only3810 (0.0%)5 (6.2%)14.2%

Threshold sensitivity for every condition

Table 3. Threshold sensitivity: maximum blank-field score percentile. Percentages have the same eligible-object denominators.
ConditionRED P95RED P99RED P99.5GREEN P95GREEN P99GREEN P99.5
blank (no transfect)1.8%0.6%0.6%1.8%0.6%0.6%
ORCO only13.7%0.0%0.0%14.6%7.0%5.6%
Or7a+ORCO23.4%10.9%10.4%9.4%1.6%1.6%
Or19a+ORCO20.2%10.3%10.3%2.9%0.4%0.4%
Or22a+ORCO12.7%4.2%4.2%1.6%0.5%0.5%
Or35a+ORCO35.0%14.0%11.5%13.5%5.5%3.5%
Or42a+ORCO33.5%6.8%5.7%7.2%1.5%0.4%
Or59b+ORCO38.7%16.5%15.7%5.7%1.3%0.4%
Or67a+ORCO37.3%10.6%9.9%7.5%3.7%3.7%
Or67b+ORCO23.8%7.3%6.7%5.7%1.0%1.0%
Or85b+ORCO30.8%16.0%15.4%9.0%5.1%4.5%
Or98a+ORCO30.8%0.7%0.0%3.8%0.7%0.7%
Measurement audit

What the controls show

The control comparison asks whether the object-calling procedure separates reporter-associated signal from the blank within this image set. We recomputed the primary counts from the object-level CSV, retaining the positive-object numerator and eligible-object denominator before comparing each nonblank condition with the untransfected control. Eight of ten OR-labelled conditions have nominal RED Holm-adjusted values below 0.05 under an independent-object model. Or22a (0.080) and Or98a (1.000) do not cross that diagnostic cutoff. These values describe the selected image objects under the stated statistical model.

Interpretation boundary. These are post-hoc, exploratory object-level calculations. Objects share fields and a single experiment, so the independence assumption is not satisfied; the blank also fitted the positivity threshold. Neither Fisher testing nor Holm correction repairs pseudoreplication or that calibration reuse. We report the values to make the comparison inspectable, without biological-significance stars or population claims. The full statistical specification is on Measurement.

Table 4. RED comparison with blank (1/170); one-sided Fisher model, Holm over 11 comparisons within this channel.
ConditionRED+ / eligibleRED fractionDifference from blank (percentage points)Nominal Fisher pNominal Holm p
Or19a+ORCO25/24210.33%+9.741.2e-058.8e-05
Or22a+ORCO8/1894.23%+3.640.0270.080
Or35a+ORCO28/20014.00%+13.411.9e-071.7e-06
Or42a+ORCO18/2636.84%+6.260.000840.004
Or59b+ORCO38/23016.52%+15.933.3e-093.7e-08
Or67a+ORCO17/16110.56%+9.973.1e-050.00019
Or67b+ORCO14/1937.25%+6.670.00090.004
Or7a+ORCO21/19210.94%+10.351.1e-058.8e-05
Or85b+ORCO25/15616.03%+15.445.1e-085.1e-07
Or98a+ORCO2/2860.70%+0.110.6871.000
ORCO only0/3420.00%-0.591.0001.000

In GREEN, only Orco-only (24/342; nominal Holm p = 0.00485) crosses the same descriptive cutoff. Or35a has 11/200 positive objects (5.5%; nominal Holm p = 0.063) across two technical fields and does not cross that cutoff. The discussion separates indicator abundance, calcium state and receptor function. Control comparison files.

The nominal 95% Wilson limits in the download quantify binomial counting uncertainty only under independent-object sampling. They exclude field clustering, threshold fitting, staining incompleteness and segmentation bias; they are not confidence intervals for a culture’s transfection efficiency.

Bright area is not localized signal

An image can look broadly fluorescent even when little signal is locally distinguishable around a resolved object. To examine that difference, Figure 17 compares the median field-level fluorescent-area percentage with the pooled positive-object fraction. The area denominator is the analyzed image pixels outside the fixed annotation exclusion; the object denominator is the eligible DAPI objects across the acquired fields. This asks whether broad area and localized object contrast vary together, rather than assuming they measure the same property.

Across 12 conditions, median fluorescent area and pooled object fractions have RED Spearman ρ = 0.23 (descriptive p = 0.47) and GREEN ρ = −0.02 (p = 0.95). Within the ten receptor labels, the corresponding ρ values are −0.32 and 0.006. Small samples, shared acquisition and different denominators prevent a precise agreement claim.

RED and GREEN scatter plots comparing median field-area positivity against pooled DAPI-object positivity, with Or98a showing high area and low object fraction
Figure 17. Each point is one condition, not a biological replicate. Pixel area uses a global blank-derived threshold; object calls use local-background-subtracted scores. Or98a is marked by a diamond. Full values and all-field clipping diagnostics are in the downloadable audit.

Or98a makes the difference concrete: median GREEN-positive area is 97.55%, but only 2/286 eligible objects (0.70%) exceed the local GREEN threshold; RED area is 23.61% versus 2/286 objects (0.70%). RED object positivity changes from 30.77% at P95 to 0.70% at P99. Broad fluorescence and local object-to-background contrast are measuring different properties.

Area coverage and detector clipping quantify different properties. Only 0.0002% of Or98a GREEN export pixels reach 255 DN in each field, while median GREEN intensity is 39–41 DN. RED clipping is 0.0002–0.0003%. DAPI has substantial clipping and merged regions, but the reporter exports do not support calling Or98a “near-saturated.” Elevated local background is a possible contributor to lower object contrast.

The measurement audit details the difference between export clipping, broad background and segmentation.

Supplementary evidence

The fluorescence-area diagnostics retain every supplied field, flag clipping at the exported value of 255, and show sensitivity to blank-derived pixel thresholds. They characterize the image exports; their percentages are neither cell percentages nor transfection efficiency. Open the full diagnostic plot.

Experimental methods · Sample records

Further reading: [7]

Kinetic assay audit

Single-well kinetic summaries

Table 5. Single-well summaries; excursions are percentages and their corrected difference is in percentage points.
Well / conditionTest excursionEarlier buffer excursionCorrected difference
A11 · ORCO / VUAA1+11.86%−9.62%+21.48 pp
A12 · untransfected / VUAA1+0.98%+0.57%+0.41 pp
A10 · Or35a + ORCO / VUAA1+17.76%+4.03%+13.73 pp
H03 · Or42a + ORCO / buffer+1.42%−30.08%+31.50 pp
H10 · Or35a + ORCO / buffer+35.25%−9.61%+44.86 pp
H11 · ORCO / buffer−0.35%+1.32%−1.67 pp

Raw traces and numerical audit

Raw RFU test time courses for ORCO-only, untransfected and Or35a plus ORCO wells across all eight stimuli.
Figure 18. Raw instrument traces for the three comparison conditions. The panels use independent y-scales to retain their measured RFUs. Amplitudes must not be compared across rows because numeric gain is unavailable. The B test pair remains excluded and C remains excluded from the corrected metric. Every condition and all four stages are included in the tidy time-series CSV.

All 420 supplied numeric baseline and excursion entries that could be compared match the independent reconstruction to the source’s four-decimal rounding. The audit also identifies two interpretation hazards: the supplied QC column labeled as a median contains first readings, and the supplied VUAA1 normalization uses a negative Or7a denominator, reversing signs. Transparent QC diagnostics replace undocumented ratios; VUAA1 normalization is omitted from the new figures.

The source’s six retained untransfected corrected values reproduce SD = 0.04483 and 3 SD = 0.13448. These are heterogeneous single wells exposed to different additions, not a calibrated blank distribution. We do not use this value as a detection limit, a significance test or a positive/negative cutoff.

Audit data and analysis files →

Complete odor-assay time courses

Open the vector figure at full size to inspect every cell condition and acquisition. The four Test 1 panels and two Test 2 panels retain all 5,280 raw readings; the right column contains 990 Test 2 normalized points.

All twelve cell conditions with four Test 1 raw acquisitions, two Test 2 raw acquisitions and Test 2 VUAA1-referenced time courses
Figure 19. Complete raw time courses for Test 1 and Test 2, with all stimuli and controls. Dashed Test 1 curves remain visible despite their exclusion from corrected metrics for reported gain mismatch. Acquisition times restart at zero; raw panels share a vertical scale within each test and cell condition. Test 2 N(t) uses a fixed endpoint VUAA1 reference, so only its final VUAA1 point is set to 1. All 66 eligible final points match Figure 14. Starting offsets, negative values and values above 1 are retained. Each trace is one well; the Test 2 blank has raw curves but no construct-referenced ratio.

The measured 48 s F0 endpoint change is subtracted as a constant from each post-addition trajectory; no F0 trace is extended to 168 s. Or7a has the smallest VUAA1-minus-DMSO reference (2.19 pp), making its ratios sensitive to that denominator. Trajectory definition and measurement scope.

Curve tables, endpoint checks and reproduction source

Test 2 odor assay: all 72 corrected values

Each table follows the Test 2 plate order. S uses post-addition 0–168 s minus F0 0–48 s. S48 uses both acquisitions over 0–48 s. Values are percentage points; one well contributes to each condition. Negative values and all controls are retained.

F0-subtracted change S (pp)
ConstructVUAA1Isopentyl acetate2-HeptanoneValeric acidPentyl acetateDMSO control
Or7a + ORCO+0.40-1.10-1.37+0.34-1.04-1.79
Or19a + ORCO+8.94-0.01+0.14+0.99-0.23-0.49
Or42a + ORCO+13.44+0.46-0.91+0.63-0.27-1.66
Or98a + ORCO+36.67-0.61+0.05+1.81-0.93-1.39
Or22a + ORCO+39.23-0.72-0.92+8.17-0.34-0.31
Or67a + ORCO+17.42-0.66-0.69+2.46+1.36-1.29
Or67b + ORCO+21.42-1.75-0.19-0.27-0.13-1.08
Or59b + ORCO+13.39-1.25-0.67-0.77-1.02-0.81
Or85b + ORCO+17.52-1.11-0.41+0.29-0.96-1.47
Or35a + ORCO+29.46-1.00-0.74+1.81-0.36-1.37
ORCO only+18.69-2.06-0.59-0.56-0.66-0.92
Blank-0.11-1.25-1.31+0.27-0.87-1.20
DMSO-subtracted change (pp)
ConstructVUAA1Isopentyl acetate2-HeptanoneValeric acidPentyl acetateDMSO control
Or7a + ORCO+2.19+0.69+0.42+2.13+0.75+0.00
Or19a + ORCO+9.43+0.48+0.63+1.48+0.26+0.00
Or42a + ORCO+15.10+2.11+0.74+2.29+1.38+0.00
Or98a + ORCO+38.06+0.78+1.44+3.20+0.46+0.00
Or22a + ORCO+39.54-0.41-0.61+8.47-0.03+0.00
Or67a + ORCO+18.71+0.63+0.60+3.75+2.65+0.00
Or67b + ORCO+22.50-0.67+0.89+0.81+0.95+0.00
Or59b + ORCO+14.20-0.43+0.15+0.04-0.21+0.00
Or85b + ORCO+18.99+0.36+1.07+1.77+0.52+0.00
Or35a + ORCO+30.83+0.37+0.63+3.18+1.00+0.00
ORCO only+19.61-1.14+0.33+0.36+0.25+0.00
Blank+1.08-0.06-0.11+1.47+0.33+0.00
DMSO and blank double difference (pp)
ConstructVUAA1Isopentyl acetate2-HeptanoneValeric acidPentyl acetateDMSO control
Or7a + ORCO+1.11+0.75+0.53+0.67+0.42+0.00
Or19a + ORCO+8.34+0.53+0.74+0.01-0.07+0.00
Or42a + ORCO+14.02+2.17+0.85+0.82+1.05+0.00
Or98a + ORCO+36.97+0.83+1.55+1.73+0.13+0.00
Or22a + ORCO+38.45-0.36-0.50+7.01-0.36+0.00
Or67a + ORCO+17.63+0.69+0.71+2.29+2.32+0.00
Or67b + ORCO+21.42-0.61+1.01-0.65+0.62+0.00
Or59b + ORCO+13.11-0.38+0.26-1.42-0.54+0.00
Or85b + ORCO+17.91+0.42+1.18+0.30+0.19+0.00
Or35a + ORCO+29.74+0.43+0.74+1.71+0.68+0.00
ORCO only+18.53-1.08+0.44-1.11-0.07+0.00
Blank+0.00+0.00+0.00+0.00+0.00+0.00
Matched 0–48 s change S48 (pp)
ConstructVUAA1Isopentyl acetate2-HeptanoneValeric acidPentyl acetateDMSO control
Or7a + ORCO+1.13+0.05-0.02+1.06+0.36-0.70
Or19a + ORCO+6.13+1.26+0.95+1.64+0.90+1.39
Or42a + ORCO+9.25+1.20+0.52+1.42+0.51-0.16
Or98a + ORCO+19.67+0.60+1.58+1.14+0.75-0.11
Or22a + ORCO+23.53+0.91+0.67+5.40+1.14+0.92
Or67a + ORCO+12.19+0.30+0.53+1.98+1.08+0.38
Or67b + ORCO+9.11+0.14+1.29+0.95+0.75+0.31
Or59b + ORCO+3.72+0.77+0.78+0.36+0.22+0.85
Or85b + ORCO+13.84+0.52+0.66+0.72+0.25+0.06
Or35a + ORCO+9.82+0.28+0.41+1.08+0.66+0.31
ORCO only+8.85-0.20+0.58+0.17+0.64+0.37
Blank-7.83+0.09+0.05+0.96+0.81+0.32

VUAA1-reference normalization

For Test 2, S is the F0-subtracted change defined above. For each construct c and stimulus s, N(s,c) = [S(s,c) − S(DMSO,c)] / [S(VUAA1,c) − S(DMSO,c)]. This sets the measured DMSO and VUAA1 reference wells to 0 and 1; it does not impose a biological response bound. Negative ratios and ratios above 1 remain valid numerical outcomes and are not clipped.

All eleven Test 2 receptor-containing denominators are positive (2.19–39.54 pp). Seven of the 44 odor ratios are negative, and none exceeds 1. Or7a’s denominator is only 2.19 pp, compared with at least 9.43 pp for the other constructs; its valeric-acid ratio of 0.972 comes from a 2.13 pp vehicle-subtracted response. The blank control is omitted from the construct-referenced ratio.

Test 1 is not shown in this normalized map: eight of its eleven buffer-referenced VUAA1 denominators are nonpositive, and its buffer row is not a matched DMSO vehicle. Direct and control-referenced ratios for both tests are retained in the research audit. These single-well ratios cannot remove well-to-well transfection differences or supply uncertainty estimates.

Test 2 VUAA1-referenced ratios
ConstructVUAA1Isopentyl acetate2-HeptanoneValeric acidPentyl acetateDMSO control
Or7a + ORCO1.0000.3140.1920.9720.3420.000
Or19a + ORCO1.0000.0510.0670.1570.0280.000
Or42a + ORCO1.0000.1400.0490.1510.0920.000
Or98a + ORCO1.0000.0200.0380.0840.0120.000
Or22a + ORCO1.000-0.010-0.0160.214-0.0010.000
Or67a + ORCO1.0000.0340.0320.2010.1410.000
Or67b + ORCO1.000-0.0300.0400.0360.0420.000
Or59b + ORCO1.000-0.0310.0100.003-0.0150.000
Or85b + ORCO1.0000.0190.0560.0930.0270.000
Or35a + ORCO1.0000.0120.0200.1030.0330.000
ORCO only1.000-0.0580.0170.0180.0130.000

Processing definitions

For Test 2, we calculate the endpoint change within each acquisition and subtract the F0 change from the post-addition change. S is expressed in percentage points (pp). For Or98a + ORCO with VUAA1, +34.09% − (−2.57%) gives +36.67 pp using unrounded values. ORCO only gives +18.69 pp, while the blank control gives −0.11 pp.

ΔF_after = 100 × (F_after,last / F_after,first − 1)
ΔF0 = 100 × (F0last / F0first − 1)
S = ΔF_after − ΔF0

The Test 2 subtraction compares a 168 s post-addition window with a 48 s F0 window. It is a descriptive disturbance correction, not a fitted bleaching correction. A matched 0–48 s calculation is included in the numerical audit: the eleven receptor-containing VUAA1 conditions remain positive, while the blank value is −7.83 pp. For VUAA1, the shorter window preserves the direction but changes the magnitude.

Control behavior remains important. In Test 1, the Or35a + ORCO buffer-only well had a 35.25% excursion. In Test 2, all twelve DMSO-control S values lie between −1.79 and −0.31 pp. Or7a + ORCO has a small positive S of +0.40 pp even though its post-addition signal falls by 1.47%, because F0 falls further. These examples show why both subtraction components accompany the corrected values.

Calculation and interpretation

B(s,c) = S(s,c) − S(DMSO,c)
C(s,c) = B(s,c) − B(s,blank)

For Test 1, the same between-well operations use its buffer-corrected excursion and buffer-only row. The four-acquisition Test 1 protocol and the two-acquisition Test 2 protocol have different within-well definitions; their magnitudes are not interchangeable. The original earlier numerical tables are retained in the audit.

View the full processing components

References

Research and technical documentation
  1. Chen, T.-W., et al. (2013). Ultrasensitive fluorescent proteins for imaging neuronal activity. Nature, 499, 295–300. doi:10.1038/nature12354.
    Source highlights
    • GCaMP6 calcium-indicator development. Basal brightness alone is not a functional calcium-response assay.
  2. Jones, P. L., Pask, G. M., Rinker, D. C., & Zwiebel, L. J. (2011). Functional agonism of insect odorant receptor ion channels. PNAS 108, 8821–8825. Source.
    Source highlights

    Characterizes VUAA1 as an Orco-family agonist using calcium imaging and electrophysiology. This literature establishes the choice of probe, not the mechanism of the AeroSense Test 1 fluorescence signal.

  3. Zboray, K., et al. (2023). High-throughput ligand profile characterization in novel cell lines expressing seven heterologous insect olfactory receptors for the detection of volatile plant biomarkers. Scientific Reports 13, 21757. Source.
    Source highlights

    Provides a published heterologous OR/ORCO fluorescence-assay precedent. Its stable cell lines and validated protocol are separate from this transient, single-plate AeroSense pilot.

  4. Thermo Fisher Scientific. DAPI solution: nuclear labeling and preparation limits. Product guidance. Manufacturer documentation.
    Source highlights
    • DAPI nuclear-labeling guidance relevant to preparation and denominator limits.
  5. Thermo Fisher Scientific. LIVE/DEAD cell viability assays. Membrane-integrity and esterase-based measurements. Manufacturer documentation.
    Source highlights
    • Independent viability assays measure features such as membrane integrity or esterase activity. mCherry fluorescence alone does not establish viability.
  6. Montero Llopis, P., et al. (2021). Best practices and tools for reporting reproducible fluorescence microscopy methods. Nature Methods, 18, 1463–1476. doi:10.1038/s41592-021-01156-w.
    Source highlights
    • Reproducible fluorescence-microscopy reporting: acquisition conditions, processing and analysis should be traceable.
  7. Nature Communications. Image integrity and standards. Source preservation and disclosure of image adjustments. Editorial policy.
    Source highlights
    • Image-integrity guidance for source preservation and disclosure of display adjustments.
On this page
Back to top