Abstract
We followed the progression from odor-related fluorescence in the fly brain to construct preparation, reporter expression and stimulus-associated fluorescence in engineered HEK293 cells.
Three light-sheet recordings show regional signals during odor delivery. Colony plates and DNA gels document construct preparation; microscopy fields and two kinetic odor assays show reporter-associated fluorescence alongside their controls.
Results at a glance
01 · Biological inspiration
Fly brain imaging
AeroSense approaches odor sensing as a pattern distributed across channels. We examined that principle by following regional fluorescence during odor delivery. TH-GFP reveals labeled structures; GH146-GCaMP6f records regional fluorescence across seven odor presentations. The two GH146 recordings come from the same fly. Figure 1 defines the measured regions; the recordings show their image context, and Figure 2 compares regional time courses with whole-image means.

Watch on iGEM Video Universe ↗
Watch on iGEM Video Universe ↗
Watch on iGEM Video Universe ↗
In the shared three-odor sequence, the middle and upper GH146 regions showed mean local ΔF/F₀ changes of +1.73% to +2.67%, while the right region ranged from −0.61% to +0.48%. Across the four additional odor windows, regional means ranged from −1.00% to +1.56%. Figures 3 and 4 align each odor window to stimulus onset and its own pre-odor baseline, allowing the regional patterns to be compared locally.


02 · Colony plates
Colony plates
The engineered-cell experiments required twelve vector constructs. We selected isolated colonies for plasmid preparation and subsequent DNA checks. Figures 5–7 show colony plates from this twelve-vector set; the markings identify the colonies selected for follow-up.
Discrete colonies were available alongside denser growth regions, allowing individual candidates to be selected for plasmid preparation.
Engineered cell experiments
DNA electrophoresis
Before transfection, we checked whether DNA was detectable in the plasmid preparations and whether paired samples showed comparable migration patterns. Figure 8 groups the undigested preparations by construct label beside the Bio-1Kb™ Mass DNA Ladder (PROTECH).
DNA is visible in all 24 sample lanes. The two lanes for each of the twelve construct labels show similar migration patterns within each pair.
Marker labels describe linear DNA fragments; undigested plasmid migration also depends on conformation.
04 · Transfection efficiency
Assessing transfection
The construct design pairs mCherry with the OR cassette and GCaMP6f with the calcium-reporting module. Before testing fluorescence kinetics, we examined the reporter channels alongside cell density and the nuclear reference. Figure 9 shows matched brightfield, DAPI, RED and GREEN images from each field.
The dataset contains 25 fields across 12 conditions: n = 1–3 technical fields per condition, N = 1 independent experiment. Select a condition and field to inspect its four matching channels.
blank (no transfect) · 3 fields acquired · technical observations

Choose a condition and inspect its acquired fields.
Object overlay: white = below both thresholds; pink = RED+; green = GREEN+; yellow = both; cyan = excluded object. Object numbers match the measurement table.
Fluorescence around resolvable DAPI objects
We quantified the fraction of eligible DAPI objects exceeding the blank-derived reporter threshold in each channel. Figure 10 shows individual technical fields and the pooled fraction, calculated as total positive objects divided by total eligible objects. The complete counts and denominators are retained in Supplementary data, Table 1.

The blank yielded 1/170 eligible objects above each channel threshold. The mCherry-free Orco-only condition yielded 0/342 RED-positive and 24/342 GREEN-positive objects, separating the two reporter channels within this image set.
05 · Odor testing
Odor testing
We followed fluorescence over time in ten OR + ORCO conditions, ORCO-only cells and the control condition specified for each test. Figures 11–14 show Test 1 and Test 2 time courses, condition comparisons, control-referenced maps and the Test 2 VUAA1-referenced map.
Test 2 contains 72 wells and 1,440 readings across ten OR + ORCO conditions, ORCO-only cells and the blank control. Each construct × stimulus has one well.
VUAA1 is an established Orco agonist used in heterologous receptor assays. [2] [3]
In Test 2, ten of twelve VUAA1 time courses end above their first reading, while eleven conditions have a positive corrected change. Or7a + ORCO and the blank control end lower; a positive corrected score does not necessarily mean that the measured trace rises.
VUAA1 signals and control behavior
Figure 12 compares all twelve conditions. In Test 2, corrected changes are +36.67 pp for Or98a + ORCO, +18.69 pp for ORCO only and −0.11 pp for the blank control.
Test 1 includes a large positive buffer-control signal, whereas the twelve Test 2 DMSO-control scores range from −1.79 to −0.31 pp. The corrected values are descriptive results from individual wells, rather than activation thresholds.
Responses relative to assay controls
Figure 13 adds the six-stimulus Test 2 screen to the original response maps. Test 2 corrected VUAA1 values range from −0.11 to +39.23 pp. Valeric acid spans −0.77 to +8.17 pp; the other three odor rows range from −2.06 to +1.36 pp. We show vehicle subtraction and the blank adjustment separately so that control-dependent changes remain visible.
Responses relative to each construct’s VUAA1 reference
Figure 14 compares each Test 2 odor response with the VUAA1 reference for the same construct, after subtracting its DMSO control. Construct-specific VUAA1 referencing has been used in heterologous receptor assays. [3]
post-addition fluorescence dynamics and the DoOR reference
A separate analysis of the retained post-addition fluorescence readings compares four odorant profiles across ten OR + ORCO conditions with the DoOR receptor database. The two views below place measured, vehicle-referenced fluorescence changes beside the receptor patterns used to inform our decoding work. The analysis uses the experimenter-confirmed channel labels and source-cell mapping in the post-addition fluorescence workbook; it reuses the Test 2 post-addition fluorescence records.
Figure 15 shows distinct profiles across the four odorants. Valeric acid has the largest positive contrast, +6.97 percentage points (pp) for the supplied Or22a channel, followed by +3.02 pp for Or67a and +2.98 pp for Or35a. Isopentyl acetate is highest for Or42a (+1.35 pp), while pentyl acetate is highest for Or67a (+1.74 pp). Values retain their signs and are shown on a common fluorescence scale.
The across-receptor comparisons show weak positive association with DoOR for 2-heptanone (Pearson r = +0.317; Spearman ρ = +0.406), isopentyl acetate (r = +0.325; ρ = +0.442) and valeric acid (r = +0.211; ρ = +0.283). Pentyl acetate is close to zero (r = −0.002; ρ = +0.006). Thus, the experimental profiles share part of the database ordering for three odorants, with agreement depending on the odorant.
Discussion
The Test 2 VUAA1 time courses show within-acquisition rises in most receptor conditions. After subtracting each well’s F0 change, eleven conditions are positive and the blank value is close to zero. Test 1 and Test 2 use different control designs and calculations, so they provide separate observations rather than interchangeable estimates.
In Test 1, the ORCO-only VUAA1 well showed an 11.86% fluorescence excursion, compared with 0.98% in the untransfected well. The 35.25% excursion in a buffer-only well shows why a rise alone cannot establish ligand-specific activation.
Colony growth and undigested-plasmid migration document preparation, but neither establishes insert sequence or construct identity. Separate RED and GREEN images likewise do not establish receptor localization or channel function.
GCaMP6f is a calcium-sensitive indicator. Its resting fluorescence is not a constitutive, calcium-independent measure of transfection. Low green signal may reflect indicator state, expression, acquisition sensitivity or background, and a single endpoint cannot distinguish these explanations. Functional interpretation requires time-resolved, controlled stimulation. [1]
The fixed-cell screen at 44–48 h and Test 1 at approximately 72 h are separate pre-selection records. Their position in the workflow does not establish that they came from the same cell batch.
The microscopy fractions all come from one experiment. Uneven field coverage, within-field clustering and density exclusions prevent ranking receptor conditions as independently replicated estimates of transfection or expression. Blank and Orco-only controls provide within-study context, but do not supply biological replication.
Test 1 used a laboratory plate reader. These results characterize the biological assay; they do not establish the performance of the assembled AeroSense reader.
Control comparisons use separate single wells and describe fluorescence patterns rather than receptor-specific activation. Test 2 includes a DMSO reference; Test 1 lacks a matched vehicle control. Unrecorded gain, cell-state variation and dilution-only concentration records limit interpretation. Vehicle-matched tests at documented doses in independent cultures are needed to separate these effects.
The post-addition fluorescence comparison provides an exploratory connection between the cell measurements and the DoOR reference used in Model. Its metric is C = Dodor − DDMSO, based on early and late post-addition fluorescence means; it is distinct from the F0-subtracted S values and VUAA1-referenced N ratios above. Positive C can represent a smaller decline than DMSO, rather than a rising trace. The experimenter confirmed matched DMSO fraction and addition volume, while gain consistency and addition-to-first-read delay remain unconfirmed. The experimenter-confirmed post-addition fluorescence channel map supersedes the earlier Test 2 receptor labels; the underlying fluorescence readings are unchanged.
The first three odorants show weak positive cross-platform agreement, while pentyl acetate does not. Leaving one receptor out gives Pearson ranges of +0.080 to +0.502, +0.198 to +0.488, +0.169 to +0.550 and −0.284 to +0.182, respectively. These ranges describe sensitivity to receptor selection, not confidence intervals. One well per condition, shared DMSO references and different measurement platforms limit transfer claims; timepoints do not increase biological n. This reanalysis does not provide an independent experimental validation, receptor-specific activation test or demonstrated fluorescence-to-odor classifier.
Conclusion
The expression screen detected reporter-associated fluorescence above the blank-derived threshold in resolvable DAPI objects. RED-positive fractions across the OR + ORCO conditions ranged from 0.7% to 16.5%; dense overlap prevents interpreting these fractions as whole-culture transfection efficiency.
The odor assays provide time-resolved evidence of VUAA1-associated fluorescence. In Test 2, F0-subtracted VUAA1 changes are +36.67 pp for Or98a + ORCO, +17.52 pp for Or85b + ORCO, +29.46 pp for Or35a + ORCO, and +18.69 pp for ORCO only, compared with −0.11 pp in the blank control. The control maps and retained raw records make these observations inspectable.
The post-addition fluorescence reanalysis adds odorant-dependent comparisons with DoOR: weak positive across-receptor associations for three odorants and near-zero association for pentyl acetate. The shared reference makes the measured profiles and their correspondence to the decoding database directly inspectable.
Data availability
Research archive: Zenodo · DOI: 10.5281/zenodo.23469212. Public release pending.
Code, analysis scripts and reusable documentation are published in the official iGEM GitLab repository. Archive availability: Research archive availability.
Source data and documents
Test 2 odor-assay archive
The complete Test 2 raw-data package is prepared locally for Zenodo; no public deposit has been verified. The package contains twelve unchanged XLSX exports, checksums, 1,440 observations with source-cell references, 72 corrected summaries, matched-window sensitivity values and reproducible analysis scripts. The earlier mean-ratio calculation is retained only as a secondary audit metric. All corrected values are available in the supplementary tables.
Test 2 correction and VUAA1-reference source Corrected Test 2 changes · CSV Corrected Test 2 observations · CSV Corrected Test 2 summary · JSON Corrected Test 2 VUAA1-referenced scores · CSV Corrected Test 2 well summary · CSV
Complete odor-assay curves
The complete-curve analysis preserves the original acquisition boundaries and checks every plotted reading against the canonical exports. The scalable figure, chart-data tables and endpoint audit accompany the single reproducible builder.
Full-size vector figure · SVG · All 5,280 raw curve readings · CSV · Test 2 referenced time courses · CSV · Figure 14 endpoint checks · CSV · Test 1 peak-metric checks · CSV · Original acquisition source checksums · JSON · Original complete-curve analysis source · Original complete-curve reproduction guide
Test 1 kinetic assay
Test 1 source and archive — Test 1 analysis source — GitLab · Full raw-data archive availability — the complete archive preserves 32 exact instrument exports, filename map, source analysis, tidy data, independent calculations, English figures and executed methods. The numerical analysis uses only Python’s standard library. Original inputs are preserved, including the source report whose claims are audited.
3,840-row tidy time series — archive availability · 96-well summaries · Analysis script — GitLab · Metadata and provenance · Test 1 executed methods · PDF · Reproduction guide — GitLab
Numerical audit · Transparent QC table · QC label audit
Endpoint microscopy
The dataset contains 100 individual-channel images across 25 fields, 12 pre-existing merges and the experimental workbook. Individual channels are 2592 × 1944 pixels; fluorescence images are 8-bit pseudocolored exports. Measurements use the individual channels and the condition and field identifiers in the supplied source folders. The WL-MIC-01 reanalysis retains the original acquisition and single-experiment scope. Acquisition metadata, processing parameters and source-file checksums accompany the analysis.
Download pixel-identical WebP image channels by condition and field
Original TIFF files and metadata: see the Original TIFF archive availability. The iGEM links below provide pixel-identical WebP images.
- blank (no transfect)
- Field 1: Brightfield · DAPI · Green · Red
- Field 2: Brightfield · DAPI · Green · Red
- Field 3: Brightfield · DAPI · Green · Red
- ORCO only
- Field 1: Brightfield · DAPI · Green · Red
- Field 2: Brightfield · DAPI · Green · Red
- Field 3: Brightfield · DAPI · Green · Red
- Or7a+ORCO
- Field 1: Brightfield · DAPI · Green · Red
- Field 2: Brightfield · DAPI · Green · Red
- Or19a+ORCO
- Field 1: Brightfield · DAPI · Green · Red
- Field 2: Brightfield · DAPI · Green · Red
- Or22a+ORCO
- Field 1: Brightfield · DAPI · Green · Red
- Field 2: Brightfield · DAPI · Green · Red
- Or35a+ORCO
- Field 1: Brightfield · DAPI · Green · Red
- Field 2: Brightfield · DAPI · Green · Red
- Or42a+ORCO
- Field 1: Brightfield · DAPI · Green · Red
- Field 2: Brightfield · DAPI · Green · Red
- Or59b+ORCO
- Field 1: Brightfield · DAPI · Green · Red
- Field 2: Brightfield · DAPI · Green · Red
- Or67a+ORCO
- Field 1: Brightfield · DAPI · Green · Red
- Field 2: Brightfield · DAPI · Green · Red
- Or67b+ORCO
- Field 1: Brightfield · DAPI · Green · Red
- Field 2: Brightfield · DAPI · Green · Red
- Or85b+ORCO
- Field 1: Brightfield · DAPI · Green · Red
- Or98a+ORCO
- Field 1: Brightfield · DAPI · Green · Red
- Field 2: Brightfield · DAPI · Green · Red
| Record | Contents | Access |
|---|---|---|
| Reproducible control audit | Fisher/Holm diagnostics, nominal Wilson limits, three blank holdouts, area/object agreement, exact input hashes and source script | Files — Microscopy analysis source — GitLab · Microscopy analysis source — GitLab · Python — GitLab · CSV |
| Analysis package | Scripts, parameters, source hashes, CSV tables and the analysis report; pixel-identical WebP images are linked separately | Browse files — Microscopy analysis source — GitLab · Microscopy analysis source — GitLab |
| Object measurements | Every segmented object ≥200 pixels, inclusion/exclusion reason, scores and threshold calls | CSV — archive availability |
| Per-field results | All 25 field denominators, positive counts and retained area | CSV |
| Per-condition results | Pooled fractions and threshold sensitivity | CSV |
| Image-export diagnostics | 100 channel records, blank-relative area, clipping, medians and large blue regions | CSV |
| Source manifest | Original filenames, bit depth, TIFF tags and SHA-256 hashes | JSON |
| Analysis report | Methods, tables, threshold sensitivity and interpretation in a standalone appendix | Microscopy analysis report · PDF |
| DNA electrophoresis | Annotated panels, pixel-identical WebP gel images, lane maps and reproducible processing settings | Annotated panels · Source gels and lane maps · Processing record · Source script — GitLab |
| Cloning photographs | Three unchanged source photographs; filenames and SHA-256 hashes | JSON |
| Source workbook | Original plate-layout and reagent-calculation records; not proof of execution or assay outcomes | XLSX — archive availability |
| Light-sheet imaging | Source measurements, ROI archives, movies, physical timestamps and reproducible plots | GH146 numerical dataset — archive availability · TH numerical dataset — archive availability |
Light-sheet recordings
Measured segmentation parameters · JSON · Light-sheet plotting source
post-addition fluorescence dynamic comparison
The complete archive includes the 1,080-reading source workbook with cell references, all 72 dynamic summaries, 48 vehicle contrasts, DoOR provenance, missing-value records and leave-one-receptor-out checks. Analysis code, validation code and reproduction guide — GitLab. The complete data package is retained in the prepared research archive; public deposit status is described in the archive availability record. The existing reference-pattern backend Pearson function independently reproduced the four reported coefficients.
Supplementary data
Microscopy counts and fields
Pooled reporter-positive fractions
| Image label | Fields | RED+ / eligible | GREEN+ / eligible | Both / eligible | DAPI foreground retained |
|---|---|---|---|---|---|
| blank (no transfect) | 3 | 1/170 (0.6%) | 1/170 (0.6%) | 1/170 (0.6%) | 9.1% |
| ORCO only | 3 | 0/342 (0.0%) | 24/342 (7.0%) | 0/342 (0.0%) | 19.6% |
| Or7a+ORCO | 2 | 21/192 (10.9%) | 3/192 (1.6%) | 1/192 (0.5%) | 16.2% |
| Or19a+ORCO | 2 | 25/242 (10.3%) | 1/242 (0.4%) | 0/242 (0.0%) | 16.2% |
| Or22a+ORCO | 2 | 8/189 (4.2%) | 1/189 (0.5%) | 1/189 (0.5%) | 9.9% |
| Or35a+ORCO | 2 | 28/200 (14.0%) | 11/200 (5.5%) | 8/200 (4.0%) | 10.2% |
| Or42a+ORCO | 2 | 18/263 (6.8%) | 4/263 (1.5%) | 1/263 (0.4%) | 22.8% |
| Or59b+ORCO | 2 | 38/230 (16.5%) | 3/230 (1.3%) | 2/230 (0.9%) | 21.1% |
| Or67a+ORCO | 2 | 17/161 (10.6%) | 6/161 (3.7%) | 4/161 (2.5%) | 10.6% |
| Or67b+ORCO | 2 | 14/193 (7.3%) | 2/193 (1.0%) | 2/193 (1.0%) | 9.5% |
| Or85b+ORCO | 1 | 25/156 (16.0%) | 8/156 (5.1%) | 7/156 (4.5%) | 18.9% |
| Or98a+ORCO | 2 | 2/286 (0.7%) | 2/286 (0.7%) | 2/286 (0.7%) | 20.2% |
Shared record WL-MIC-01 · acquisition provenance · measurement pipeline and calibration audit.
Images were acquired 44–48 h after transfection, before G418 selection, with the same exposure within each fluorescence channel across conditions and blank calibration. All 25 fields come from one supplied transfection study, without independent biological repeats. The control comparison below is an exploratory calculation on the selected objects; it cannot establish a reproducible difference between cultures.
Open every field directly
- blank (no transfect): Field 1, Field 2, Field 3
- ORCO only: Field 1, Field 2, Field 3
- Or7a+ORCO: Field 1, Field 2
- Or19a+ORCO: Field 1, Field 2
- Or22a+ORCO: Field 1, Field 2
- Or35a+ORCO: Field 1, Field 2
- Or42a+ORCO: Field 1, Field 2
- Or59b+ORCO: Field 1, Field 2
- Or67a+ORCO: Field 1, Field 2
- Or67b+ORCO: Field 1, Field 2
- Or85b+ORCO: Field 1
- Or98a+ORCO: Field 1, Field 2
We excluded ambiguous connected regions instead of forcing a cell count through the dense aggregates. The condition table gives the number of positive objects and the denominator explicitly. “DAPI foreground retained” is the eligible objects’ share of segmented blue area, not the fraction of all cells or nuclei retained. The low retained area warns that these estimates sample the easier-to-segment portion of each field.
Density and thresholds matter
The images contain broad connected DAPI regions and clipping at the maximum exported value. Even a sharp edge around a fluorescent patch can contain several overlapping nuclei. Retaining a small, isolated subset avoids inventing divisions within those clusters, but introduces a selection bias. The excluded regions remain visible in every overlay.
Threshold choice also matters. For Or98a + Orco, the RED-positive fraction changes from 30.8% at the less stringent blank P95 threshold to 0.7% at P99. We use the conservative P99 rule as the primary analysis and report the full sensitivity table.
All per-field object counts and fractions
| Condition | Field | Eligible DAPI objects | RED+ | GREEN+ | DAPI foreground retained |
|---|---|---|---|---|---|
| blank (no transfect) | 1 | 36 | 1 (2.8%) | 1 (2.8%) | 5.3% |
| blank (no transfect) | 2 | 72 | 0 (0.0%) | 0 (0.0%) | 12.4% |
| blank (no transfect) | 3 | 62 | 0 (0.0%) | 0 (0.0%) | 11.4% |
| Or19a+ORCO | 1 | 114 | 9 (7.9%) | 1 (0.9%) | 15.7% |
| Or19a+ORCO | 2 | 128 | 16 (12.5%) | 0 (0.0%) | 16.7% |
| Or22a+ORCO | 1 | 137 | 7 (5.1%) | 0 (0.0%) | 14.8% |
| Or22a+ORCO | 2 | 52 | 1 (1.9%) | 1 (1.9%) | 5.8% |
| Or35a+ORCO | 1 | 100 | 14 (14.0%) | 7 (7.0%) | 7.1% |
| Or35a+ORCO | 2 | 100 | 14 (14.0%) | 4 (4.0%) | 17.1% |
| Or42a+ORCO | 1 | 105 | 5 (4.8%) | 1 (1.0%) | 27.7% |
| Or42a+ORCO | 2 | 158 | 13 (8.2%) | 3 (1.9%) | 20.2% |
| Or59b+ORCO | 1 | 151 | 12 (7.9%) | 0 (0.0%) | 20.9% |
| Or59b+ORCO | 2 | 79 | 26 (32.9%) | 3 (3.8%) | 21.4% |
| Or67a+ORCO | 1 | 132 | 13 (9.8%) | 6 (4.5%) | 12.1% |
| Or67a+ORCO | 2 | 29 | 4 (13.8%) | 0 (0.0%) | 7.6% |
| Or67b+ORCO | 1 | 78 | 13 (16.7%) | 2 (2.6%) | 9.6% |
| Or67b+ORCO | 2 | 115 | 1 (0.9%) | 0 (0.0%) | 9.5% |
| Or7a+ORCO | 1 | 88 | 15 (17.0%) | 2 (2.3%) | 15.1% |
| Or7a+ORCO | 2 | 104 | 6 (5.8%) | 1 (1.0%) | 17.4% |
| Or85b+ORCO | 1 | 156 | 25 (16.0%) | 8 (5.1%) | 18.9% |
| Or98a+ORCO | 1 | 140 | 2 (1.4%) | 2 (1.4%) | 30.5% |
| Or98a+ORCO | 2 | 146 | 0 (0.0%) | 0 (0.0%) | 15.2% |
| ORCO only | 1 | 120 | 0 (0.0%) | 8 (6.7%) | 23.2% |
| ORCO only | 2 | 141 | 0 (0.0%) | 11 (7.8%) | 22.5% |
| ORCO only | 3 | 81 | 0 (0.0%) | 5 (6.2%) | 14.2% |
Threshold sensitivity for every condition
| Condition | RED P95 | RED P99 | RED P99.5 | GREEN P95 | GREEN P99 | GREEN P99.5 |
|---|---|---|---|---|---|---|
| blank (no transfect) | 1.8% | 0.6% | 0.6% | 1.8% | 0.6% | 0.6% |
| ORCO only | 13.7% | 0.0% | 0.0% | 14.6% | 7.0% | 5.6% |
| Or7a+ORCO | 23.4% | 10.9% | 10.4% | 9.4% | 1.6% | 1.6% |
| Or19a+ORCO | 20.2% | 10.3% | 10.3% | 2.9% | 0.4% | 0.4% |
| Or22a+ORCO | 12.7% | 4.2% | 4.2% | 1.6% | 0.5% | 0.5% |
| Or35a+ORCO | 35.0% | 14.0% | 11.5% | 13.5% | 5.5% | 3.5% |
| Or42a+ORCO | 33.5% | 6.8% | 5.7% | 7.2% | 1.5% | 0.4% |
| Or59b+ORCO | 38.7% | 16.5% | 15.7% | 5.7% | 1.3% | 0.4% |
| Or67a+ORCO | 37.3% | 10.6% | 9.9% | 7.5% | 3.7% | 3.7% |
| Or67b+ORCO | 23.8% | 7.3% | 6.7% | 5.7% | 1.0% | 1.0% |
| Or85b+ORCO | 30.8% | 16.0% | 15.4% | 9.0% | 5.1% | 4.5% |
| Or98a+ORCO | 30.8% | 0.7% | 0.0% | 3.8% | 0.7% | 0.7% |
Measurement audit
What the controls show
The control comparison asks whether the object-calling procedure separates reporter-associated signal from the blank within this image set. We recomputed the primary counts from the object-level CSV, retaining the positive-object numerator and eligible-object denominator before comparing each nonblank condition with the untransfected control. Eight of ten OR-labelled conditions have nominal RED Holm-adjusted values below 0.05 under an independent-object model. Or22a (0.080) and Or98a (1.000) do not cross that diagnostic cutoff. These values describe the selected image objects under the stated statistical model.
Interpretation boundary. These are post-hoc, exploratory object-level calculations. Objects share fields and a single experiment, so the independence assumption is not satisfied; the blank also fitted the positivity threshold. Neither Fisher testing nor Holm correction repairs pseudoreplication or that calibration reuse. We report the values to make the comparison inspectable, without biological-significance stars or population claims. The full statistical specification is on Measurement.
| Condition | RED+ / eligible | RED fraction | Difference from blank (percentage points) | Nominal Fisher p | Nominal Holm p |
|---|---|---|---|---|---|
| Or19a+ORCO | 25/242 | 10.33% | +9.74 | 1.2e-05 | 8.8e-05 |
| Or22a+ORCO | 8/189 | 4.23% | +3.64 | 0.027 | 0.080 |
| Or35a+ORCO | 28/200 | 14.00% | +13.41 | 1.9e-07 | 1.7e-06 |
| Or42a+ORCO | 18/263 | 6.84% | +6.26 | 0.00084 | 0.004 |
| Or59b+ORCO | 38/230 | 16.52% | +15.93 | 3.3e-09 | 3.7e-08 |
| Or67a+ORCO | 17/161 | 10.56% | +9.97 | 3.1e-05 | 0.00019 |
| Or67b+ORCO | 14/193 | 7.25% | +6.67 | 0.0009 | 0.004 |
| Or7a+ORCO | 21/192 | 10.94% | +10.35 | 1.1e-05 | 8.8e-05 |
| Or85b+ORCO | 25/156 | 16.03% | +15.44 | 5.1e-08 | 5.1e-07 |
| Or98a+ORCO | 2/286 | 0.70% | +0.11 | 0.687 | 1.000 |
| ORCO only | 0/342 | 0.00% | -0.59 | 1.000 | 1.000 |
In GREEN, only Orco-only (24/342; nominal Holm p = 0.00485) crosses the same descriptive cutoff. Or35a has 11/200 positive objects (5.5%; nominal Holm p = 0.063) across two technical fields and does not cross that cutoff. The discussion separates indicator abundance, calcium state and receptor function. Control comparison files.
The nominal 95% Wilson limits in the download quantify binomial counting uncertainty only under independent-object sampling. They exclude field clustering, threshold fitting, staining incompleteness and segmentation bias; they are not confidence intervals for a culture’s transfection efficiency.
Bright area is not localized signal
An image can look broadly fluorescent even when little signal is locally distinguishable around a resolved object. To examine that difference, Figure 17 compares the median field-level fluorescent-area percentage with the pooled positive-object fraction. The area denominator is the analyzed image pixels outside the fixed annotation exclusion; the object denominator is the eligible DAPI objects across the acquired fields. This asks whether broad area and localized object contrast vary together, rather than assuming they measure the same property.
Across 12 conditions, median fluorescent area and pooled object fractions have RED Spearman ρ = 0.23 (descriptive p = 0.47) and GREEN ρ = −0.02 (p = 0.95). Within the ten receptor labels, the corresponding ρ values are −0.32 and 0.006. Small samples, shared acquisition and different denominators prevent a precise agreement claim.

Or98a makes the difference concrete: median GREEN-positive area is 97.55%, but only 2/286 eligible objects (0.70%) exceed the local GREEN threshold; RED area is 23.61% versus 2/286 objects (0.70%). RED object positivity changes from 30.77% at P95 to 0.70% at P99. Broad fluorescence and local object-to-background contrast are measuring different properties.
Area coverage and detector clipping quantify different properties. Only 0.0002% of Or98a GREEN export pixels reach 255 DN in each field, while median GREEN intensity is 39–41 DN. RED clipping is 0.0002–0.0003%. DAPI has substantial clipping and merged regions, but the reporter exports do not support calling Or98a “near-saturated.” Elevated local background is a possible contributor to lower object contrast.
The measurement audit details the difference between export clipping, broad background and segmentation.
Supplementary evidence
The fluorescence-area diagnostics retain every supplied field, flag clipping at the exported value of 255, and show sensitivity to blank-derived pixel thresholds. They characterize the image exports; their percentages are neither cell percentages nor transfection efficiency. Open the full diagnostic plot.
Experimental methods · Sample records
Further reading: [7]
Kinetic assay audit
Single-well kinetic summaries
| Well / condition | Test excursion | Earlier buffer excursion | Corrected difference |
|---|---|---|---|
| A11 · ORCO / VUAA1 | +11.86% | −9.62% | +21.48 pp |
| A12 · untransfected / VUAA1 | +0.98% | +0.57% | +0.41 pp |
| A10 · Or35a + ORCO / VUAA1 | +17.76% | +4.03% | +13.73 pp |
| H03 · Or42a + ORCO / buffer | +1.42% | −30.08% | +31.50 pp |
| H10 · Or35a + ORCO / buffer | +35.25% | −9.61% | +44.86 pp |
| H11 · ORCO / buffer | −0.35% | +1.32% | −1.67 pp |
Raw traces and numerical audit
All 420 supplied numeric baseline and excursion entries that could be compared match the independent reconstruction to the source’s four-decimal rounding. The audit also identifies two interpretation hazards: the supplied QC column labeled as a median contains first readings, and the supplied VUAA1 normalization uses a negative Or7a denominator, reversing signs. Transparent QC diagnostics replace undocumented ratios; VUAA1 normalization is omitted from the new figures.
The source’s six retained untransfected corrected values reproduce SD = 0.04483 and 3 SD = 0.13448. These are heterogeneous single wells exposed to different additions, not a calibrated blank distribution. We do not use this value as a detection limit, a significance test or a positive/negative cutoff.
Complete odor-assay time courses
Open the vector figure at full size to inspect every cell condition and acquisition. The four Test 1 panels and two Test 2 panels retain all 5,280 raw readings; the right column contains 990 Test 2 normalized points.
The measured 48 s F0 endpoint change is subtracted as a constant from each post-addition trajectory; no F0 trace is extended to 168 s. Or7a has the smallest VUAA1-minus-DMSO reference (2.19 pp), making its ratios sensitive to that denominator. Trajectory definition and measurement scope.
Test 2 odor assay: all 72 corrected values
Each table follows the Test 2 plate order. S uses post-addition 0–168 s minus F0 0–48 s. S48 uses both acquisitions over 0–48 s. Values are percentage points; one well contributes to each condition. Negative values and all controls are retained.
| Construct | VUAA1 | Isopentyl acetate | 2-Heptanone | Valeric acid | Pentyl acetate | DMSO control |
|---|---|---|---|---|---|---|
| Or7a + ORCO | +0.40 | -1.10 | -1.37 | +0.34 | -1.04 | -1.79 |
| Or19a + ORCO | +8.94 | -0.01 | +0.14 | +0.99 | -0.23 | -0.49 |
| Or42a + ORCO | +13.44 | +0.46 | -0.91 | +0.63 | -0.27 | -1.66 |
| Or98a + ORCO | +36.67 | -0.61 | +0.05 | +1.81 | -0.93 | -1.39 |
| Or22a + ORCO | +39.23 | -0.72 | -0.92 | +8.17 | -0.34 | -0.31 |
| Or67a + ORCO | +17.42 | -0.66 | -0.69 | +2.46 | +1.36 | -1.29 |
| Or67b + ORCO | +21.42 | -1.75 | -0.19 | -0.27 | -0.13 | -1.08 |
| Or59b + ORCO | +13.39 | -1.25 | -0.67 | -0.77 | -1.02 | -0.81 |
| Or85b + ORCO | +17.52 | -1.11 | -0.41 | +0.29 | -0.96 | -1.47 |
| Or35a + ORCO | +29.46 | -1.00 | -0.74 | +1.81 | -0.36 | -1.37 |
| ORCO only | +18.69 | -2.06 | -0.59 | -0.56 | -0.66 | -0.92 |
| Blank | -0.11 | -1.25 | -1.31 | +0.27 | -0.87 | -1.20 |
| Construct | VUAA1 | Isopentyl acetate | 2-Heptanone | Valeric acid | Pentyl acetate | DMSO control |
|---|---|---|---|---|---|---|
| Or7a + ORCO | +2.19 | +0.69 | +0.42 | +2.13 | +0.75 | +0.00 |
| Or19a + ORCO | +9.43 | +0.48 | +0.63 | +1.48 | +0.26 | +0.00 |
| Or42a + ORCO | +15.10 | +2.11 | +0.74 | +2.29 | +1.38 | +0.00 |
| Or98a + ORCO | +38.06 | +0.78 | +1.44 | +3.20 | +0.46 | +0.00 |
| Or22a + ORCO | +39.54 | -0.41 | -0.61 | +8.47 | -0.03 | +0.00 |
| Or67a + ORCO | +18.71 | +0.63 | +0.60 | +3.75 | +2.65 | +0.00 |
| Or67b + ORCO | +22.50 | -0.67 | +0.89 | +0.81 | +0.95 | +0.00 |
| Or59b + ORCO | +14.20 | -0.43 | +0.15 | +0.04 | -0.21 | +0.00 |
| Or85b + ORCO | +18.99 | +0.36 | +1.07 | +1.77 | +0.52 | +0.00 |
| Or35a + ORCO | +30.83 | +0.37 | +0.63 | +3.18 | +1.00 | +0.00 |
| ORCO only | +19.61 | -1.14 | +0.33 | +0.36 | +0.25 | +0.00 |
| Blank | +1.08 | -0.06 | -0.11 | +1.47 | +0.33 | +0.00 |
| Construct | VUAA1 | Isopentyl acetate | 2-Heptanone | Valeric acid | Pentyl acetate | DMSO control |
|---|---|---|---|---|---|---|
| Or7a + ORCO | +1.11 | +0.75 | +0.53 | +0.67 | +0.42 | +0.00 |
| Or19a + ORCO | +8.34 | +0.53 | +0.74 | +0.01 | -0.07 | +0.00 |
| Or42a + ORCO | +14.02 | +2.17 | +0.85 | +0.82 | +1.05 | +0.00 |
| Or98a + ORCO | +36.97 | +0.83 | +1.55 | +1.73 | +0.13 | +0.00 |
| Or22a + ORCO | +38.45 | -0.36 | -0.50 | +7.01 | -0.36 | +0.00 |
| Or67a + ORCO | +17.63 | +0.69 | +0.71 | +2.29 | +2.32 | +0.00 |
| Or67b + ORCO | +21.42 | -0.61 | +1.01 | -0.65 | +0.62 | +0.00 |
| Or59b + ORCO | +13.11 | -0.38 | +0.26 | -1.42 | -0.54 | +0.00 |
| Or85b + ORCO | +17.91 | +0.42 | +1.18 | +0.30 | +0.19 | +0.00 |
| Or35a + ORCO | +29.74 | +0.43 | +0.74 | +1.71 | +0.68 | +0.00 |
| ORCO only | +18.53 | -1.08 | +0.44 | -1.11 | -0.07 | +0.00 |
| Blank | +0.00 | +0.00 | +0.00 | +0.00 | +0.00 | +0.00 |
| Construct | VUAA1 | Isopentyl acetate | 2-Heptanone | Valeric acid | Pentyl acetate | DMSO control |
|---|---|---|---|---|---|---|
| Or7a + ORCO | +1.13 | +0.05 | -0.02 | +1.06 | +0.36 | -0.70 |
| Or19a + ORCO | +6.13 | +1.26 | +0.95 | +1.64 | +0.90 | +1.39 |
| Or42a + ORCO | +9.25 | +1.20 | +0.52 | +1.42 | +0.51 | -0.16 |
| Or98a + ORCO | +19.67 | +0.60 | +1.58 | +1.14 | +0.75 | -0.11 |
| Or22a + ORCO | +23.53 | +0.91 | +0.67 | +5.40 | +1.14 | +0.92 |
| Or67a + ORCO | +12.19 | +0.30 | +0.53 | +1.98 | +1.08 | +0.38 |
| Or67b + ORCO | +9.11 | +0.14 | +1.29 | +0.95 | +0.75 | +0.31 |
| Or59b + ORCO | +3.72 | +0.77 | +0.78 | +0.36 | +0.22 | +0.85 |
| Or85b + ORCO | +13.84 | +0.52 | +0.66 | +0.72 | +0.25 | +0.06 |
| Or35a + ORCO | +9.82 | +0.28 | +0.41 | +1.08 | +0.66 | +0.31 |
| ORCO only | +8.85 | -0.20 | +0.58 | +0.17 | +0.64 | +0.37 |
| Blank | -7.83 | +0.09 | +0.05 | +0.96 | +0.81 | +0.32 |
VUAA1-reference normalization
For Test 2, S is the F0-subtracted change defined above. For each construct c and stimulus s, N(s,c) = [S(s,c) − S(DMSO,c)] / [S(VUAA1,c) − S(DMSO,c)]. This sets the measured DMSO and VUAA1 reference wells to 0 and 1; it does not impose a biological response bound. Negative ratios and ratios above 1 remain valid numerical outcomes and are not clipped.
All eleven Test 2 receptor-containing denominators are positive (2.19–39.54 pp). Seven of the 44 odor ratios are negative, and none exceeds 1. Or7a’s denominator is only 2.19 pp, compared with at least 9.43 pp for the other constructs; its valeric-acid ratio of 0.972 comes from a 2.13 pp vehicle-subtracted response. The blank control is omitted from the construct-referenced ratio.
Test 1 is not shown in this normalized map: eight of its eleven buffer-referenced VUAA1 denominators are nonpositive, and its buffer row is not a matched DMSO vehicle. Direct and control-referenced ratios for both tests are retained in the research audit. These single-well ratios cannot remove well-to-well transfection differences or supply uncertainty estimates.
| Construct | VUAA1 | Isopentyl acetate | 2-Heptanone | Valeric acid | Pentyl acetate | DMSO control |
|---|---|---|---|---|---|---|
| Or7a + ORCO | 1.000 | 0.314 | 0.192 | 0.972 | 0.342 | 0.000 |
| Or19a + ORCO | 1.000 | 0.051 | 0.067 | 0.157 | 0.028 | 0.000 |
| Or42a + ORCO | 1.000 | 0.140 | 0.049 | 0.151 | 0.092 | 0.000 |
| Or98a + ORCO | 1.000 | 0.020 | 0.038 | 0.084 | 0.012 | 0.000 |
| Or22a + ORCO | 1.000 | -0.010 | -0.016 | 0.214 | -0.001 | 0.000 |
| Or67a + ORCO | 1.000 | 0.034 | 0.032 | 0.201 | 0.141 | 0.000 |
| Or67b + ORCO | 1.000 | -0.030 | 0.040 | 0.036 | 0.042 | 0.000 |
| Or59b + ORCO | 1.000 | -0.031 | 0.010 | 0.003 | -0.015 | 0.000 |
| Or85b + ORCO | 1.000 | 0.019 | 0.056 | 0.093 | 0.027 | 0.000 |
| Or35a + ORCO | 1.000 | 0.012 | 0.020 | 0.103 | 0.033 | 0.000 |
| ORCO only | 1.000 | -0.058 | 0.017 | 0.018 | 0.013 | 0.000 |
Processing definitions
For Test 2, we calculate the endpoint change within each acquisition and subtract the F0 change from the post-addition change. S is expressed in percentage points (pp). For Or98a + ORCO with VUAA1, +34.09% − (−2.57%) gives +36.67 pp using unrounded values. ORCO only gives +18.69 pp, while the blank control gives −0.11 pp.
ΔF_after = 100 × (F_after,last / F_after,first − 1)ΔF0 = 100 × (F0last / F0first − 1)S = ΔF_after − ΔF0
The Test 2 subtraction compares a 168 s post-addition window with a 48 s F0 window. It is a descriptive disturbance correction, not a fitted bleaching correction. A matched 0–48 s calculation is included in the numerical audit: the eleven receptor-containing VUAA1 conditions remain positive, while the blank value is −7.83 pp. For VUAA1, the shorter window preserves the direction but changes the magnitude.
Control behavior remains important. In Test 1, the Or35a + ORCO buffer-only well had a 35.25% excursion. In Test 2, all twelve DMSO-control S values lie between −1.79 and −0.31 pp. Or7a + ORCO has a small positive S of +0.40 pp even though its post-addition signal falls by 1.47%, because F0 falls further. These examples show why both subtraction components accompany the corrected values.
Calculation and interpretation
B(s,c) = S(s,c) − S(DMSO,c)C(s,c) = B(s,c) − B(s,blank)
For Test 1, the same between-well operations use its buffer-corrected excursion and buffer-only row. The four-acquisition Test 1 protocol and the two-acquisition Test 2 protocol have different within-well definitions; their magnitudes are not interchangeable. The original earlier numerical tables are retained in the audit.