On this page

Project Search

0 results

Dry Lab · Model

Model

Hardware simulations, odor decoding and receptor engineering

Hardware simulations / Summary

Physical model overview

The gas model predicts a four-well surface t90 of 47.80–49.42 s at 3 mL/min, D = 10 mm²/s and a 100 µL fill. Conditional optical transport predicts D3 detector collection of 0.593 ± 0.035 nW. We use these separate calculations to locate transport and readout limits before interpreting a biological signal.

Hardware simulations / Physical models

Transport and measurement assumptions

Molecules must reach the cells and emitted light must reach the detector. We model these steps separately to locate limits from optical collection, excitation leakage, gas distribution and liquid transport.

These physical models quantify gas delivery to the liquid interface, fluorescence collection and optical interference in the reader design.

This study concerns the proposed reader’s physical signal path. Odor decoding is a separate study of metal-oxide sensor data.

Hardware simulations / 01

Gas arrival at the wells

We compared chamber geometry and flow under the same inlet concentration step to test arrival time and delivery uniformity. Maps locate delayed regions; surface curves show timing and spatial spread across wells.

Inputs
Integral shelf, nominal CAD and 100 µL per well
Method
Gas flow and advection–diffusion
Output
Gas-side surface concentration and arrival time

Arrival is measured from a concentration step at the modeled inlet to the area-mean gas concentration in the first layer above the liquid. The calculation stops at the gas side of that interface; it does not predict uptake into the medium or the cell response.

We first compared how a concentration step moves through the chamber. The movie holds the color scale fixed across geometries and flows; the maps below resolve that progression in a vertical section and immediately above each well.

Gas concentration at the liquid surfacesSimulation · 60 s
Video 1. Geometry comparison at 3 mL/min, followed by the selected shelf at 1, 3 and 5 mL/min. Each chapter shows 180 physical seconds in 30 seconds of playback and uses the same concentration scale. The clock resets between chapters. Maps and curves use computed gas concentrations; the liquid is a stationary boundary.
Gas concentration in the northern section and at all four liquid surfaces after 10, 30 and 60 seconds
Figure 1. At 3 mL/min, D = 10 mm²/s and 100 µL per well, a vertical section and the first gas-cell layers show concentration after 10, 30 and 60 s. Every panel uses C/Cin from 0 to 1. Blank regions are outside the gas domain; values are gas concentrations, not concentrations in the medium.

The maps reveal where gas remains dilute, but choosing a flow also requires a time threshold. We therefore tracked each well’s surface-area mean as it approaches the inlet concentration; the shaded curves retain spatial variation around that mean.

Liquid-adjacent gas concentration over time and slowest-well arrival time across flow rates and gas diffusivities.
Figure 2. Gas arrival at the liquid surface. Curves show surface-area mean concentration; shading spans the spatial 10th–90th percentiles. Nominal conditions are 3 mL/min, gas diffusivity 10 mm²/s and a 0.4 mm grid. Time starts at the modeled inlet concentration step. These are gas-arrival times, not cellular response times.

At 3 mL/min and nominal gas diffusivity 10 mm²/s, the four surfaces reach 10% of inlet concentration in 5.30–6.29 s and 90% in 47.80–49.42 s. Across the three tested diffusivities, the slowest surface reaches 90% in approximately 50 s on the main grid.

Geometry was compared at the same flow and diffusivity to separate redistribution from simply pumping faster. Read each interval from t10 to t90 and compare its t50 marker: the shelf redirects gas without giving the shortest interval in every case.

Gas-surface concentration and rise-time intervals for the open chamber, perforated plate and integral shelf
Figure 3. At Q = 3 mL/min and D = 10 mm²/s, the slowest surface t90 is 51.67 s for the open chamber, 48.36 s for the original 12-hole plate and 49.42 s for the shelf. The intervals show t10–t90, with t50 marked by a dot; they are not error bars. Small differences on one grid do not establish a physical ranking.

For the selected shelf, the slowest surface t90 is 149.3, 49.4 and 29.9 s at 1, 3 and 5 mL/min. The 3 mL/min candidate retains timing margin without treating faster arrival as the only design criterion. The geometry comparison and numerical sensitivity checks below test the effects of chamber design and discretization.

Finally, flow and diffusivity sweeps test the operating range, while grid and time-step checks show how much the timing depends on discretization. The small separation between geometries must be read alongside these numerical shifts.

Twenty-one first-layer gas transport cases and grid and time-step sensitivity checks
Figure 4. First-layer timing across seven flows and three diffusivities. At Q = 3 mL/min and D = 20 mm²/s, t90 is 50.024 s on the main grid, 51.010 s at 0.3 mm, 50.499 s at 0.2 mm and 49.872 s with the main-grid time step halved. Grid changes also change the stair-step geometry; these are numerical sensitivity checks, not experimental uncertainty intervals.
Hardware simulations / 02

Liquid and membrane transport

Gas must also cross the liquid to reach bottom-attached cells. We varied liquid depth and diffusivity before adding a membrane; compare depth effects first, then the membrane’s added delay.

The first comparison places gas-side wash-in and delivery to the well floor on their respective time axes. It tests whether chamber equilibration is a useful proxy for exposure of bottom-attached cells.

Separate time scales for gas-interface wash-in and liquid-bottom delivery
Figure 5. Gas and liquid transport have different time scales. At 8.929 mm depth, bottom t90 is 45.67, 22.83 and 11.42 h for D = 0.5, 1 and 2 × 10⁻⁹ m²/s. These deterministic, unmixed surface-step calculations describe transport to the bottom, not receptor or GCaMP response time.

At 100 µL per well, the nominal liquid depth is 8.929 mm. With an ideal concentration step at the surface, no mixing and liquid diffusivity D = 10⁻⁹ m²/s, the model gives a bottom t90 of 22.83 h. The relation t90 ≈ 1.031105 L²/D makes liquid depth a strong design variable: halving the path reduces this idealized time fourfold. [1]

Depth and effective diffusivity were varied independently to ask which design change could shorten that path. The depth sweep tests geometric distance; the mixing multiplier represents a hypothetical transport enhancement.

Sensitivity of bottom delivery to liquid depth and an assumed effective mixing factor
Figure 6. Bottom delivery scales with liquid depth squared and inversely with diffusivity. A 25 µL counterfactual gives about 1.43 h at D = 10⁻⁹ m²/s; the selected fill remains 100 µL. Increased effective diffusivity represents an assumed mixing effect, not an implemented mixing mechanism.

A membrane adds another barrier whose importance may depend on liquid mixing. The thickness–diffusivity–partitioning sweep separates those regimes: color tracks delay, while gray marks conditions that do not reach the target during the simulated window.

Coupled membrane and liquid sensitivity across the assumed parameter grid
Figure 7. PDMS thickness, diffusivity and partitioning jointly control delay. The 40 displayed cells are a slice of 243 deterministic conditions, at 100 µL fill, liquid D = 10⁻⁹ m²/s and liquid–gas partition coefficient 10. Gray cells did not reach 90% within 168 h. Material inputs are illustrative; the model does not measure target-specific permeability or cell stability.

The coupled PDMS sweep tests 243 material and geometry combinations. A representative 100 µm film changes t90 from 22.85 to 23.39 h under stagnant-liquid assumptions; with liquid diffusion increased 100-fold, the same comparison becomes 0.25 versus 0.85 h. The liquid can dominate one regime and the membrane another. This supports the no-film baseline until a target molecule and measured permeability justify adding a layer.

Hardware: selected no-film chamber and sample geometry →

Hardware simulations / 03

Trace excitation and fluorescence

We varied optical geometry to test fluorescence collection and source-well mixing at the shared detector. Compare collection with spatial variation, then follow each LED row across the mixing matrix to separate intended-well signal from crosstalk.

Inputs
CAD, 500 µW LED-on reference, assumed optical properties
Method
Finite-detector Monte Carlo photon transport
Output
Collection, spatial variation and well mixing
Decision
Fix registration and calibrate each well

Geometry reference. The 470/520 nm study and path movie use monochromatic transport. The separate spectral comparison weights unfiltered Monte Carlo inputs by wavelength; the two studies report different power and noise quantities. spectral filter comparison

The Monte Carlo geometry contains four registered wells, a finite offset photodiode, a finite emission filter and specified resin/liquid interfaces. Excitation and fluorescence packets are scored separately at nominal wavelengths of 470 and 520 nm. The reference source is a 20 µm layer at the well floor with absorption 0.5 mm−1, quantum yield 1 and 500 µW LED-on power. Ideal clear resin is an explicit assumption, not a measured material specification.

The optical maps follow Burton et al.’s separation of excitation fluence and detector acceptance (Fig. 2H–J). AeroSense computes its own four-well geometry; none of the paper’s device performance is transferred. [2]

Current optical parameter sweep with three-seed uncertainty
Figure 8. Current optical sensitivity study. Every comparison uses the stated geometry and source assumptions; error bars represent finite Monte Carlo sampling.
Canonical optical simulation matrix: row-normalized response percentages for readout D1 to D4 and source wells D1 to D4
Figure 9. Simulation · canonical optical mixing. This is the same floor-layer design model used in Hardware. Each row is normalized to 100%; for example, D4 own-well power 0.657 nW becomes 90.9% of its row total. Rows are LED / readout channels and columns are fluorescent source wells. The original three-seed matrix and its 20 µm source layer, absorption coefficient 0.5 mm⁻¹ and geometry are unchanged. Measured comparison

The measured comparison pairs all 16 corresponding entries of the simulated and measured row-normalized matrices. The scatter plot uses simulation on the horizontal axis and measurement on the vertical axis, retaining negative measured responses; Pearson r = 0.810. This is a descriptive association between dependent matrix entries, not evidence that the response magnitudes are equal.

The D3 reference yields 0.593 ± 0.035 nW at the ideal detector (mean ± one SE across three seeds). Intended-well shares span 88.6–90.9% across LED rows; D3 floor CV is 46.2%. The original power-matrix condition number is approximately 1.86.

Optical paths and modulated detector tracesOriginal simulation · 20 s
Video 2. 100× slow motion: Panel A displays saved D3 sample trajectories only; the four LED indicators and ideal, conditional received and residual traces share one clock. Paths switch with LED state: they are not simulated photon flight times. Traces use green-equivalent nW. No calcium response, measured PCB timing or fabricated paths for the other wells are included. Data availability.
Current four-well floor excitation maps
Figure 10. Simulation · spatial illumination. D3 illumination uses 600,000 excitation packets; collection uses 224 source positions with 65,536 packets each and 0.5 × 0.4 mm pixels. The D3 floor irradiance has spatial CV 46.2%. Collection-map standard errors and Wilson 95% bounds are saved in the source but are not plotted as error bars; median relative collection-map SE is 17.3%. These are Monte Carlo sampling uncertainties, not biological replicates or measured uniformity. Fixed well registration and spatially distributed standards remain necessary. Method precedent: separate illumination and collection maps in Burton et al. [2] Data availability. Positive irradiance and collection efficiency are shown in red; white denotes zero.
Hardware simulations / 04

Filter choice: predicted signal and leakage

Frequency tagging cannot reject excitation leakage at the fluorescence modulation frequency. We compare filter rejection against signal retention: read the spectra, integrated currents and signal-to-noise estimates under the same source assumptions.

Inputs
Unfiltered Monte Carlo powers, source spectra and detector response
Method
Spectral weighting, synthetic current and four-frequency complex fits
Output
Signal retention, conditional noise and blank-drift sensitivity
Decision
Select one LEE 101 layer; verify headroom and blank stability

The comparison tests no filter, one or two LEE101 layers, and a constructed 500 nm OD4 longpass scenario. The model integrates wavelength-dependent source power, filter transmission and detector responsivity to predict photodiode current in nA under the stated optical assumptions.

Burton et al. also separate fluorescence collection from excitation leakage in a compact photometry reader. Here, LEE transmission comes from the vendor curve; the paper’s filter and device measurements are not used as LEE 101 performance data. [2]

Filter transmission, source spectra, retained photocurrent and conditional SNR
Figure 11. Simulation · spectral comparison. LEE uses sampled vendor data; the OD4 pointwise curve is constructed. Panel C shows relative integrated photocurrent on a logarithmic axis (0.01–200%); panel D gives the minimum analytic SNR across four channels for a 1% fluorescence change after an ideal stable blank. No experimental or Monte Carlo confidence bands are shown. Data availability.
Table 1. Modeled detector currents and ideal-blank analytic SNR for four filter scenarios under the same sources. LED and proxy-green currents are percentages of the no-filter case; SNR assumes a 1% fluorescence change and the stated idealized noise model.
Detector screenLED current (%)Proxy-green current (%)Raw peak (nA)Ideal-blank analytic SNR for 1% ΔF
No filter100.000100.00104.3639.09
LEE 101 ×12.98770.434.08716.14
LEE 101 ×20.41051.271.22012.77
500 nm OD4 ×1*0.19482.741.34420.54

Under the stated noise assumptions, one LEE 101 layer retains 70.43% of modeled proxy-green current with analytic SNR 16.14 for a 1% change. The two-layer and constructed OD4 cases compare signal retention with stronger rejection.

Selected design

Use one LEE 101 layer in the reader. Retain raw I/Q, independent illuminated blanks and a signed phase reference; do not automatically apply the simulated mixing matrix.

Four filter scenarios with raw current, residual and corrected AC on different vertical scales
Figure 12. Simulation · filter waveforms. The first 200 ms of four filter scenarios under identical source powers, clock and noise seeds. Columns show raw and ideal current, raw residual including DC and excitation leakage, and blank-corrected AC at four fundamentals. Vertical scales differ; OD4 is a constructed filter scenario. Data availability.
Blank-corrected residual and modeled sensitivity to excitation-leakage drift
Figure 13. Simulation · stability requirement. Left: one seeded corrected AC residual, in pA, on the same four-frequency basis. Right: deterministic blue I/Q gain drift relative to a hypothetical 1% fluorescence change; the dotted 0.1 line is an example engineering budget, not a validated acceptance limit. Fixed optical mean powers and a constructed OD4 scenario are used; no hardware drift is measured, and these curves are not uncertainty intervals. Data availability.
Hardware simulations / 05

What the models changed

Table 2. Computational evidence and the resulting gas-flow, optical and membrane design decisions.
QuestionEvidenceDecision
Can gas direction change without another part?Shelf/open comparison, including worse exchange symmetryKeep the integrated shelf and eight selected prints
Which flow gives useful gas wash-in?26 current surface cases and the 28-point operating-band sweepSelect 3 mL/min conditionally against declared criteria
Does a finite PD collect modeled fluorescence?MC geometry and acceptance mapsRetain the carrier as a test candidate; preserve filter / PD registration
Are frequency tags independent wells?Nonzero off-diagonal optical contributionsPreserve complex channels and measure a mixing matrix
Does lock-in reject synchronous excitation?Per-LED leakage and conditional channel biasSelect one LEE 101 layer and an independent illuminated blank; measure actual headroom

Hardware: resulting apparatus and assembly →

Hardware simulations / Discussion

Discussion

Gas-surface arrival and transport to bottom-attached cells are separate processes. The shelf redirects flow without being fastest in every comparison. The selected 3 mL/min condition provides margin against the 60 s criterion; grid sensitivity weakens the near-threshold 2.5 mL/min result. The membrane sweep supports a no-film baseline until delivery and recovery at the cell plane are measured.

Optical mixing requires a measured channel matrix, while LED-synchronous leakage requires an illuminated blank. Predicted currents and Monte Carlo SE depend on the assumed source, material, detector and filter properties; they do not include measured electronics or cellular variation. The constructed OD4 scenario also uses a different mounting geometry from the selected film.

Strong same-well entries drive much of the simulated–measured matrix association: the 12 cross-well entries alone give Pearson r = 0.257. Different source distributions and electronic effects prevent treating this as quantitative leakage agreement. Blank and dye calibration, single-source-well tests, detector headroom and noise, and assembled-path flow and concentration measurements are the next checks.

Hardware simulations / Conclusion

Conclusion

The calculations support one LEE 101 layer, an integral shelf and a conditional 3 mL/min operating point. They also identify liquid-path length as a potential bottleneck. These design choices now have explicit optical, gas-delivery and cell-plane measurements against which they can be tested.

From sensor patterns to receptor patterns

A fly-inspired spiking network reaches its highest observed UCI macro-F1 of 0.83 and ends at 0.79 in one training run. Layerwise probes locate the largest loss at the KC→MBON readout. On 91 DoOR odorants, a coarser quantile encoding with denser wiring raises SNN macro-F1 from 0.46 to 0.52. The analyses guide a readout redesign and define the measurements needed before transfer to the cell platform.

Introduction

A pattern across receptors can distinguish odors even when no receptor is uniquely selective. The fly mushroom body suggests a compact computational strategy: expand an input into many sparsely active Kenyon cells (KCs), then learn the connections to mushroom-body output neurons (MBONs). Random projection-neuron (PN) convergence and APL-mediated inhibition motivate this design. [Turner] [Caron] [Lin]

We implement this motif in Brian2 and ask two questions: can the network classify response patterns, and where does useful class information disappear? UCI-270 tests gas identity from metal-oxide sensor measurements; DoOR tests chemical-family prediction from published fly-receptor responses. Wet-lab measurements are examined separately from these benchmark inputs. [Brian2] [Model record]

Network schematic from the model record
Figure 1. Network schematic from the model record. The reported experiments use PN, KC, APL, MBON, MBON inhibition and the training-only forced answer. The drawn ALLN and reward-prediction-error/DAN elements are not used in these experiments; the diagram is broader than the tested circuit.
Two input domains share the PN–KC–MBON pipeline: UCI-270 provides 128 sensor features per measurement, while DoOR provides ten receptor values per odorant
Figure 2. Two input domains share the PN–KC–MBON pipeline: UCI-270 provides 128 sensor features per measurement, while DoOR provides ten receptor values per odorant. The dashed cell-line input is a proposed transfer route, not an experimentally trained cell-based classifier.

Two datasets, two prediction tasks

The two benchmark datasets and the distinct questions they answer.
PropertyUCI-270DoOR subset
Input16 metal-oxide sensors; eight features per sensorOr7a, Or19a, Or22a, Or35a, Or42a, Or59b, Or67a, Or67b, Or85b and Or98a
Samples13,910 measurements across ten batches and 36 months91 odorants measured on at least eight of the ten receptors
LabelsEthanol, ethylene, ammonia, acetaldehyde, acetone and tolueneAcids (15), alcohols (20), aromatics (15), esters (25), terpenes (16)
ValuesResistance change, normalized change and six exponential-moving-average features per sensorUnitless consensus receptor responses, 0–1; 13.4% missing cells
Prediction questionRecognize a gas from repeated sensor measurementsRecognize a chemical family for a held-out odorant

UCI-270 is the public Gas Sensor Array Drift at Different Concentrations dataset. DoOR combines published receptor recordings into a consensus matrix; the selected ten receptors correspond to the wet-lab panel. Missing DoOR values are filled with training-split medians. [UCI-270] [Vergara] [Rodríguez-Luján] [DoOR]

DoOR consensus responses for 91 odorants and ten receptors
Figure 3. DoOR consensus responses for 91 odorants and ten receptors. Darker blue denotes stronger response; grey cells are missing published measurements. Acids and terpenes are weak across this panel, while alcohols, esters and aromatics recruit different overlapping receptors.

Standardization, PCA and population coding

For UCI, the 128 features are standardized and projected onto 20 principal components using training data only. Three components retain 75% of the reported variance and twenty retain 98%. For DoOR, ten standardized receptor values are reduced to six components, retaining 86%. PCA captures variance, which need not coincide with class separation. [PCA]

UCI-270 projected onto the first three principal components after standardization
Figure 4. UCI-270 projected onto the first three principal components after standardization. Each panel highlights one gas; approximately 5% of extreme display positions are omitted for visibility. The display omission is not described as a training-data exclusion. The final panel shows explained variance.
DoOR odorants projected onto the first three principal components
Figure 5. DoOR odorants projected onto the first three principal components. Each panel highlights a chemical family. Acids and terpenes overlap in a weak-response region, while alcohols and esters are dispersed. The six retained components explain 86% of the reported variance.

Each PCA axis selects one PN bin. UCI uses 20 training-data quantile bins per axis: 20 components × 20 bins produce 400 PNs, with 20 active per exposure. Values outside the training range enter the outermost bin. Quantile bins allocate resolution where samples are dense; they replace equal-width bins that leave much of the code unused. DoOR compares 20 equal-width bins per component (120 PNs) with five quantile bins (30 PNs). Bin boundaries are fitted to training data.

Network dynamics and learning

The UCI network contains 400 PNs, 2,000 KCs, one APL neuron and six MBONs. Fixed random PN→KC connections have probability 0.0125, or about five inputs per KC, normalized to 800 nS total input. KCs excite APL, which inhibits KCs. Every KC projects to all MBONs; MBONs mutually inhibit one another. This is a biological abstraction, not a reconstruction of every fly connection. [Expansion] [Connectivity]

Conductance-based leaky integrate-and-fire neurons are integrated with forward Euler at 0.1 ms. A spike resets the membrane potential. Synaptic conductances decay exponentially and increase by the connection weight on each presynaptic spike:

C dV/dt = gL(EL − V) + gAMPA(EAMPA − V) + gGABA(EGABA − V) + Iinput
dgx/dt = −gx/τx; on a presynaptic spike, gx ← gx + w

KC thresholds rise with recent activity and recover during silence. The spike trace x increases by 0.1 per spike and decays over 10 ms:

dVth/dt = ηx(t)(Vmax − Vth) − κ(Vth − Vmin) 𝟙[x(t) < 10−6]

Only KC→MBON synapses learn. The model uses a pair-based potentiating rule: either spike order strengthens a synapse when KC and MBON spikes are close in time, with 5 ms traces. Each weight remains within 0–10 nS; each KC’s outgoing weights are normalized to a 10 nS total after every training exposure. A correct-class teacher drives its MBON during training. Testing switches off the teacher and freezes learning; the MBON with the most spikes supplies the answer. This potentiating rule is a modeling choice. [STDP] [MBONs] [Plasticity]

The complete settings and the DoOR differences are in Supplementary parameters.

Training and evaluation

Evaluation units and splits. Repeated network presentations do not increase the number of independent measurements.
AnalysisTraining and held-out unitReported evaluation
UCI SNN learning curveGas-stratified random 80%/20% measurement split; up to 800 cycles, six sampled exposures per cycle1,800 test presentations (300 per gas), checked after every 100 cycles; one training run
UCI representation probesLinear SVM at each layer; repeated presentations of the same measurement stay togetherThe same five measurement-grouped folds over 1,799 recorded presentations of 1,322 measurements after 800 cycles
DoOR comparisonThe same stratified five odorant folds for the SNN and logistic-regression readoutsEach odorant belongs to one held-out fold; about 18 odorants per fold

An exposure lasts 30 ms, followed by a 3 ms gap. Macro-F1 averages class-specific F1 scores, so each class contributes equally. The learning curve and representation probes answer different questions: probe classifiers are fitted within the recorded held-out representations. Their grouped folds prevent repeated copies of one measurement from crossing the probe training/test boundary.

UCI: training stability and the readout bottleneck

The single UCI run reaches macro-F1 0.80 after 100 cycles and a highest displayed value of 0.83 at 300 cycles. Performance then falls to 0.53 at 400 cycles and returns to 0.79 at 800. More training is therefore not monotonically better; 0.83 is the observed checkpoint maximum, not an independently replicated estimate.

UCI-270 macro-F1 on 1,800 test presentations at 100-cycle checkpoints in one run
Figure 6. UCI-270 macro-F1 on 1,800 test presentations at 100-cycle checkpoints in one run. The dashed 0.89 line is the linear SVM readout of KC spikes from the 800-cycle representation analysis; it is not a separately measured KC baseline at every checkpoint.

The measurement-grouped probes score 0.97 on the standardized features, 0.96 after PCA, 0.92 on PN spike counts and 0.89 on KC spike counts. Both the MBON probe and the network’s most-active-MBON decision score 0.79. The largest adjacent drop in this analysis is KC→MBON (0.10), motivating a readout-focused redesign.

Class information accessible to a linear SVM at successive representations, after 800 UCI training cycles
Figure 7. UCI layerwise readout after 800 training cycles. Five folds are grouped by measurement over 1,799 presentations from 1,322 measurements. Bars show mean macro-F1 and lines show source-reported fold spread. Blue denotes the network’s most-active-MBON answer.

DoOR: coarse coding for a small receptor dataset

For the 91 DoOR odorants, logistic regression scores 0.69 on the ten receptor values and 0.71 on six PCA components. Twenty equal-width PN bins reduce the linear-readout score to 0.52; five quantile bins retain 0.66. The SNN scores 0.46 and 0.52 respectively, compared with 0.09 for always choosing the largest family.

DoOR chemical-family macro-F1 on the same five odorant folds
Figure 8. DoOR chemical-family macro-F1 on the same five odorant folds. Blue bars compare SNN configurations; dark grey bars show logistic-regression readouts. Binning, PN→KC connectivity and training duration vary together. Bars are means and lines show source-reported fold spread.

The coarser configuration uses five quantile bins and PN→KC probability 0.2 for 100 cycles; the equal-width configuration uses twenty bins and probability 0.05 for 200 cycles. Both provide about six PN inputs per KC. With roughly 73 training odorants per fold, coarse bins reduce fragmentation of this small dataset. A remaining gap between PN-code and SNN readouts identifies room for readout improvement.

First comparison with wet-lab measurements

The model record compares DoOR with the first four-acquisition wet-lab assay, Test 1. Its four retained odorants are 3-octanol, benzaldehyde, 2-heptanone and valeric acid. Each receptor–odorant condition has one well. This comparison is separate from Test 2’s within-stage drift subtraction and VUAA1-reference ratios in Measurement and Results.

Test 1 responses and DoOR reference patterns
Figure 9. Test 1 responses and DoOR reference patterns. Each point is one receptor; measured ΔF is the Test 1 peak-based corrected response fraction. The grey ±0.043 area is a source-reported reference band. Pearson r and p annotations are retained from the supplied analysis.

The source reports correlations from −0.63 to +0.17 across the four odorants, and pooled r = −0.18, p = 0.28 over 39 receptor–odorant pairs.

post-addition fluorescence dynamics alongside the decoding reference

The subsequent post-addition fluorescence reanalysis compares four odorants with DoOR consensus minus receptor-specific spontaneous firing rate. Across tuning receptors, Pearson r / Spearman ρ are +0.317 / +0.406 for 2-heptanone, +0.325 / +0.442 for isopentyl acetate, +0.211 / +0.283 for valeric acid, and −0.002 / +0.006 for pentyl acetate. The comparison includes ten receptors per odorant, except the missing Or42a–valeric acid reference (n = 9). Results presents the two comparison figures.

These profiles connect the wet-lab observations to the database used for decoding: three odorants share part of its receptor ordering, with a near-zero relationship for pentyl acetate. Reusing the existing reference-pattern backend’s Pearson calculation reproduced all four coefficients.

Discussion

The results support a focused computational conclusion: the UCI representation retains class information through KC activity, while the learned readout loses more. On DoOR, coarse encoding helps a small odorant dataset, but bin count, wiring probability and training duration change together. Controlled ablations are needed to isolate their contributions. The biology motivates the architecture; benchmark scores alone do not show that each circuit motif causes an improvement.

The UCI split is random rather than day- or batch-held-out. Reusing its held-out set for checkpoints and parameter comparisons makes the best checkpoint exploratory. The DoOR folds are small, and their spread is not independent training-seed replication. For Figure 7, the source reports 1,799 rather than the planned 1,800 presentations; it does not document the omitted presentation. Neither benchmark measures food-safety classification or a trained fluorescence-to-odor system.

The Test 1–DoOR comparison has one well per receptor–odorant condition and does not establish transfer to the cell platform. We propose three to five independent wells per condition, with controls and a prespecified analysis, for the next experiment. Its ±0.043 reference band has no supplied calculation or replicate sampling definition, so it is not a biological uncertainty interval. The source reports 39 pooled pairs but does not supply the complete paired vector or explain the missing fortieth pair; the correlation statistics are retained as reported. This comparison does not use Test 2’s S or VUAA1-normalized N. Likewise, fold-spread lines in the UCI and DoOR plots have no specified SD/SE or confidence-interval definition.

The source describes an integer implementation, but this update supplies figures and methods rather than matching executable training code, fitted preprocessing, fold assignments, seeds or integer/float agreement tests. We therefore make no new device-speed, energy or integer-accuracy claim. The reader’s current reference-pattern backend is distinct from a deployed PN–KC–MBON classifier. Earlier KT/UCI analyses, including their clock-error finding, remain in the historical supplement.

The post-addition fluorescence comparison reuses Test 2 recordings under a separately defined, vehicle-referenced metric and the experimenter-confirmed channel map; it is not another independent experiment. Weak across-receptor correlations are evidence of partial profile correspondence, not decoder accuracy. The computational cross-check runs the existing Pearson function only. A PN–KC–MBON inference run would require a fitted input transformation and compatible trained checkpoint, which are not supplied with these fluorescence data.

Conclusion

The next computational priority is the KC→MBON readout, evaluated with fixed comparison folds and independent training runs. For receptor data, input resolution must match the number of available odorants.

The post-addition fluorescence profiles provide a measured starting point for comparing the cell platform with the DoOR reference. Their odorant-dependent agreement motivates a future paired evaluation with fixed preprocessing and independently replicated cell measurements.

This study combines published receptor-response data with our computational analyses. It is separate from the metal-oxide sensor datasets in Odor decoding and from the HEK293 assays in Results. Its figures and data come from the Data availability; no engineered-receptor improvement is claimed.

AeroSense · Computational receptor design

Receptor Engineering

From response data and cross-species tests to receptor design and molecular access.

Receptor candidates and computational evidence

We identified receptor candidates, built a response-prediction model and established a molecular-analysis workflow to guide experimental evaluation.

  • 1 · Priority receptors for functional testing

    Published measurements support prioritizing Or22a and Or35a, two fly odorant receptors: their mean responses were higher for our selected mold-related odorants than for the control panel. This comparison prioritizes candidates for testing against mold-associated and control odorants. ([1])

    Read the evidence
  • 2 · A model of receptor–odorant response

    We curated 2,640 responses across 24 receptors and 110 odorants, combining receptor sequences with molecular features. ([1]) In the latest matched 109-odorant comparison, the baseline achieved R² ≈ 0.39 for held-out chemical groups. It has predictive value with substantial remaining error; R² is not percentage accuracy.

    Read the evidence
  • 3 · Vibrational and AI features connected to the predictor

    We processed and tested 82 measured IR (infrared) spectra, published quantum vibration modes for 85 odorants, and OpenPOM features for 109 odorants. OpenPOM learns molecular representations from odor descriptions. ([2]; [3]; [4]; [5]) The workflow works, but these additions have not consistently outperformed the original model.

    Read the evidence
  • 4 · Candidate access directions and local obstructions

    In the mosquito reference complex, we established molecular dynamics (MD, simulation of atomic motion) in a membrane environment, extended simulations to 70 ns (nanoseconds) and identified two candidate access directions. Whole-molecule path scans located protein and lipid clashes. This identifies positions to investigate, but no route has been validated by complete molecular passage.

    Read the evidence
  • 5 · Mutation designs and computational checks

    We designed 35 single-amino-acid substitutions and checked structures and docking poses for a subset. None of the tested mutations showed robust evidence of improved selectivity.

    Read the evidence

AeroSense needs receptors that help distinguish mold-associated volatile patterns. We combine response data and receptor sequences with molecular size, measured and computed vibrations, learned odor features, cross-species evaluation, structural models and molecular dynamics. The studies below connect each question to its method, result and next design decision.

Receptor prediction, molecular features and ligand-access studies

Research questions and evidence

Select a study to inspect its question, result and interpretation.

01–02 · Candidate design in Drosophila receptors

Receptor sequence + odorant chemistry (including weight) → functional response predictor

Matched holdouts, random controls and uncertainty analysis supported retaining the baseline.

Parallel question · Cross-species transferFly data → Anopheles receptors → direct prediction & local-fragment matchingDirect transfer failed; local matching yielded a weak, unconfirmed signal. Explore the evidence →

The structural question motivates a separate reference-system study and a comparison of species-specific receptor contexts.

03–06 · Molecular access in the OR10 (odorant receptor 10 from Aedes aegypti, the yellow-fever mosquito) ([6]) reference complex

Design candidates · Drosophila receptors

Published odor-response measurements guide Or22a (one of the named Drosophila melanogaster odorant receptors in our design panel) ([1]) / Or35a mutation screening. AlphaFold (AI system that predicts protein 3D structures from sequence) ([7]) models and ColabFold (protein-structure prediction workflow built around AlphaFold and fast sequence searches) ([8]) predictions support structural hypotheses.

Test transfer · Anopheles receptors

Compare fly-trained predictions with mosquito measurements, and test whether local sequence fragments identify receptors with similar response profiles. This is a separate test of generalization.

Investigate access · OR10 reference complex

Cryo-EM (cryo-electron microscopy: reconstructing molecular structures from electron images of frozen samples) structures 8V00 (PDB ID for the experimentally determined odorant-free OR10–Orco complex) ([6]) and 8V02 (PDB ID for the experimentally determined o-cresol-bound OR10–Orco complex) provide an unbound and o-cresol (2-methylphenol, the odorant resolved in 8V02)-bound reference: mosquito OR10 (odorant receptor 10 from Aedes aegypti, the yellow-fever mosquito) with three Orco (odorant-receptor co-receptor, a shared partner that forms the channel with the odor-selective OR) subunits from Apocrypta bakeri. This separate model system does not validate Drosophila mutations. 8V00 · 8V02

Research evidence

Data foundation and evaluation design

Published receptor–odorant measurements define the response matrix and benchmark. Receptor and chemical-group holdouts separately test extension beyond observed combinations.

The curated benchmark contains 2,640 published responses across 24 receptors and 110 odorants, with separate holdouts for different generalization questions.

Published measurements

The response data behind receptor selection

Figure 1. All 2,640 curated Hallem receptor–odorant responses. Columns retain odorant-ID order; the CSV gives the chemical identities. Red and blue indicate positive and negative recorded responses. These are published electrophysiological measurements, not new team experiments. Published data source: ([1]).

Candidate prediction

Computational evidence

From response data to candidates

Compare published responses for mold-related and control odor panels, then test added molecular and receptor features against held-out measurements. Panel differences select candidates; matched ablations test predictive information, not mutant function.

Published response differences prioritize Or22a and Or35a for functional testing, while receptor sequence features improve held-out-receptor prediction without establishing mold specificity or improved mutant function.

Published measurements

Choosing the first receptors

Figure 2. Published mean responses for the five-receptor screening panel, comparing the selected mold-related odorants with controls. Or35a (one of the named Drosophila melanogaster odorant receptors in our design panel) and Or22a show the largest positive panel differences here. These are literature measurements, not team-generated functional tests; panel preference does not establish specificity to mold. Published data source: ([1]).
Our computational results

Prediction comparison

Figure 3. Prediction for held-out receptors. R² (coefficient of determination; 1 is perfect, 0 matches the mean baseline, and negative values are worse) rises with sequence information. The full feature set adds only 0.0031 over the ligand (a molecule that can bind to a receptor; here, the tested odorant) + sequence baseline (paired 95% interval −0.0316 to 0.0344). Values come from matched out-of-fold predictions on 2,640 receptor–odorant pairs; this is not a biological intervention result. Published data source: ([1]).
Our computational results

Which information improves generalization?

Figure 4. Matched feature ablation on unseen chemical clusters and unseen receptors. L: ligand (a molecule that can bind to a receptor; here, the tested odorant); S: sequence/ESM2 (protein language model used here to turn sequences into numerical features) ([9]); P: pocket (a local cavity in the receptor that can accommodate the ligand); D: docking (computationally placing and scoring ligand poses in a receptor) ([10])/contact; M: multiple poses. All groups use the same data, estimator settings and folds. The small full-model gain over LS on unseen receptors has an interval spanning zero; these bars alone do not establish significance. Published data source: ([1]).

Research evidence

Test richer odorant features

We compared measured vibrations, computed modes and learned molecular features with the baseline. Each comparison uses matched compounds and folds, separating feature effects from dataset coverage.

Measured spectra, harmonic modes and frozen learned features were tested against matched baselines; none established a consistent gain across models and holdouts.

Research evidence

Experiment A · molecular weight and measured IR

Measured IR may overlap with size-related descriptors. Compare added spectra and removal of molecular weight or size features against matched baselines, separately for chemical and receptor holdouts.

Adding measured IR spectra did not improve prediction for held-out chemical groups in either tested model, and small held-out-receptor gains remained uncertain.

Our computational results

Measured IR and size ablation

Figure 5. All variants use the same 82 odors and fixed folds. Removing molecular weight differs from removing all three size-related descriptors. IR (infrared absorption: how a molecule absorbs light at different vibrational frequencies) did not improve chemical-holdout R² (coefficient of determination; 1 is perfect, 0 matches the mean baseline, and negative values are worse) in either model; full paired intervals are downloadable.

Research evidence

Experiment B · complete harmonic modes, EVA and computed IR

We compared frequency-based EVA, intensity-weighted computed IR, fold-contained compression and random controls. The second figure retrains measured and computed alternatives on shared compounds, separating representation effects from larger-cohort results.

EVA and computed-IR features derived from published harmonic modes produced model- and holdout-dependent changes in prediction.

Our computational results

Quantum feature comparison

Figure 6. The 85-odorant comparison includes full EVA (a fixed-length descriptor formed by smoothing equally weighted normal-mode frequencies) ([11]), computed IR (infrared absorption: how a molecule absorbs light at different vibrational frequencies), training-fold-only PCA (principal component analysis, which compresses features along directions of greatest variation) and random-feature controls. PCA moves chemical-holdout scores closer to baseline but does not exceed it. These are predictions of published functional responses. ([1])
Our computational results

Measured and computed spectra on the same odors

Figure 7. All models are retrained on the same 67-odorant overlap. Different spectral ranges, dimensions and normalization remain part of the comparison; it cannot isolate source accuracy. Scores should not be compared directly to the larger cohorts.

Research evidence

Experiment C · transfer frozen OpenPOM molecular features

We transferred frozen OpenPOM features from odor-description learning to receptor-response prediction. Compare matched variants and paired gain intervals; pretraining alone does not validate receptor predictions.

Frozen OpenPOM features changed prediction performance in a model-dependent direction, with no stable POM-specific gain established over the matched baseline.

Our computational results

Does an odor-perception AI improve receptor predictions?

Figure 8. Matched 109-odorant comparison. All variants retain molecular weight and sequence features. The second fixed checkpoint is a sensitivity analysis, not a selected best model. Chemical-group holdout applies to downstream response labels; upstream molecular exposure is possible. ([4]; [5])
Our computational results

Do the improvements survive uncertainty?

Figure 9. Points show added-feature ΔR² (difference in R² between the compared models); lines show paired group-bootstrap (resampling observations or groups to assess statistical uncertainty) 95% intervals conditional on fixed predictions. Each row uses its own eligible cohort and matched baseline, not a common ranking of features. A line crossing zero does not establish a reliable gain; secondary intervals are unadjusted.

Mutation comparison

Computational evidence

Does better docking support selectivity?

We paired mutant and wild-type docking across the same odor panels. Compare score shifts with side-chain–ligand distances to test each candidate’s rationale, rather than relying on a favorable pose.

The proposed mutations did not retain a robust positive panel preference across docking checks, so their selectivity benefits remain hypotheses for functional testing.

Our computational results

Do the proposed mutations improve panel preference?

Figure 10. Common-box docking (computationally placing and scoring ligand poses in a receptor) comparison against each wild-type receptor. Dots show mean shifts; bars span the minimum and maximum across docking searches, not a confidence interval. The shift is mean ΔVina (mutant docking score minus the corresponding wild-type score) for controls minus mean ΔVina for the mold-related panel; positive values favor the selected mold-related panel. No candidate stays positive across the searches. This scoring diagnostic does not establish an affinity or functional change. Structure / method references: ([8]; [10]).
Our computational results

Checking the proposed mutation mechanism

Figure 11. Minimum mutated-side-chain distance to each odorant in the historical top docking (computationally placing and scoring ligand poses in a receptor) pose. Blue outlines mark distances ≤4.5 Å (ångström; 1 Å = 0.1 nm). F34Y (residue 34: phenylalanine → tyrosine) and E196Q (residue 196: glutamate → glutamine) are distant from the ligand (a molecule that can bind to a receptor; here, the tested odorant) in these poses; I87V (residue 87: isoleucine → valine) illustrates that geometrical contact alone does not establish improved panel selectivity. Values are pose-level geometry, not binding energies. Structure / method references: ([8]; [10]).

Research evidence

Can receptor function transfer across species?

We tested fly-trained response predictions against mosquito measurements and separately compared sequence similarity with functional profiles. Read prediction–observation agreement before evaluating the ranking signal from local sequence matching.

The fly-trained baseline did not transfer reliably to mosquito responses, while local sequence matching produced only a weak exploratory signal requiring independent validation.

Our computational results

Fly-trained predictions versus mosquito measurements

Figure 12. Each point is one of 2,000 mosquito receptor–odorant pairs across 50 Anopheles receptors and 40 shared odorants. The fly-trained ExtraTrees (an ensemble of decision trees with randomized splitting rules) baseline has R² (coefficient of determination; 1 is perfect, 0 matches the mean baseline, and negative values are worse) = −0.288 and Spearman ρ (rank correlation, from −1 to +1; it measures ordering, not prediction accuracy as a percentage) = −0.060. The dashed line is perfect agreement, not a fitted trend. Observed responses come from Carey et al.; predictions come from this project. Receptors and odorants are shared across points, so the points are not independent biological replicates. Published data source: ([1]; [12]).
Our computational results

Sequence methods for finding functional analogues

Figure 13. All twelve tested sequence methods on the primary 48 × 24 receptor-pair set. Points show agreement between sequence scores and Pearson (correlation measuring linear similarity between numerical profiles) similarity of the 40-odorant response profiles; bars are receptor-bootstrap (resampling observations or groups to assess statistical uncertainty) intervals. The leading 31-aa (amino-acid residues) reciprocal method reaches Spearman ρ (rank correlation, from −1 to +1; it measures ordering, not prediction accuracy as a percentage) = 0.141, but its BH-adjusted (Benjamini–Hochberg multiple-testing correction; q is the adjusted p-value reported here) ([13]) q = 0.259 does not meet 0.05. Methods were selected using the same matrix. This is an exploratory profile-matching analysis, not a validated odor-response predictor. Published data source: ([1]; [12]).

Receptor dynamics

Computational evidence

Does receptor motion improve odor ranking?

Receptor motion may change accessible poses and rankings. We compared static and trajectory-derived ensembles against a published functional panel; trajectory diagnostics qualify the ranking results where structural regions drift.

In the 29-odorant literature panel, docking to MD-derived receptor ensembles did not improve response ranking over the static unbound reference.

Our computational results

Odor-response ranking

Figure 14. Retrospective ranking of 29 odorants from one published calcium-response assay (a defined experimental test of biological activity). Points show Spearman ρ (rank correlation, from −1 to +1; it measures ordering, not prediction accuracy as a percentage); intervals are exploratory odor-bootstrap (resampling observations or groups to assess statistical uncertainty) intervals and omit experimental measurement uncertainty. MD (molecular dynamics: computing atomic motion step by step from a force field) ([14]) ensembles did not outperform static 8V00 (PDB ID for the experimentally determined odorant-free OR10–Orco complex) ([6]). The aromatic-ring-count comparison (ρ = 0.790) was an exploratory chemical baseline added after inspecting the panel. Published data source: ([15]).
Our computational results

The original bound-state MD diagnostics

Figure 15. Completed bound-state trajectories to 20 ns (nanoseconds, 10⁻⁹ seconds). Lines show 0.1 ns-bin medians, except hydrogen-bond geometry, shown as the within-bin fraction. Shading marks the prespecified 15–20 ns analysis window. Temperature and membrane readouts coexist with continued rebuilt-region drift. Geometry checks passed, but the trajectories do not establish equilibrium, binding affinity or an experimentally validated loop conformation.
Our computational results

Which parts move during odorant-free MD?

Figure 16. Recorded 5 ns (nanoseconds, 10⁻⁹ seconds) trajectories of the two rebuilt apo (the odorant-free state) starting models. All three readouts use the same fit to resolved-core Cα (alpha-carbon atoms, used to trace the protein backbone) atoms and measure displacement from each starting structure. Rebuilt regions cover the modeled missing parts of the complex, not only OR10 (odorant receptor 10 from Aedes aegypti, the yellow-fever mosquito) ([6]). The shaded first 1 ns includes heating and staged restraint release; the remaining 4 ns are unrestrained. Larger motion in rebuilt regions motivates structural uncertainty checks; these short trajectories do not demonstrate equilibrium or correct loop reconstruction.

Ligand encounter

Computational evidence

Bring odorants closer to a candidate entrance

Docking does not explain arrival at the pocket. We varied starting positions and molecular availability, tracking each molecule’s distance and pocket contacts; approach alone does not meet the sustained-entry criterion.

Bringing o-cresol closer to the receptor or increasing molecular availability produced encounters but no sustained pocket entry in the analyzed trajectories.

Our computational results

Distance and contacts during attempted entry

Figure 17. Actual unrestrained trajectories from water, membrane-interface and near-entrance placements, shown as 20 ps (picoseconds, 10⁻¹² seconds)-bin medians. A/B identify the two starting models; all analyzed trajectories are included. Dashed lines mark the separate entry components: pocket (a local cavity in the receptor that can accommodate the ligand) distance ≤0.5 nm (nanometers; 1 nm = 10⁻⁹ meters) and contact with at least four pocket residues (within 0.45 nm), jointly sustained for 100 ps. The full-frame analysis found no entry. The 2 ns (nanoseconds, 10⁻⁹ seconds) and 10 ns observation windows differ, so this plot does not estimate comparative entry probabilities.
Method schematic

Three ways to increase receptor encounters

Figure 18. Placement schemes used to distinguish diffusion to the receptor from pocket (a local cavity in the receptor that can accommodate the ligand) entry. Orange shapes indicate initial odorant positions; the first panel shows alternative water and interface placements. The drawings do not show observed trajectories. More available molecules or a shorter starting distance did not establish sustained entry in the analyzed simulations. The concentration comparison remains exploratory.

Opening and relaxation

Computational evidence

Does an open entrance permit release?

We guided entrance distances toward the unbound reference to test a possible geometric obstruction. Compare reduced geometry error with ligand distance and persistence after bias removal: changing receptor geometry and releasing the ligand are separate outcomes.

Guiding entrance distances toward the unbound reference changed receptor geometry, but neither guided nor unsteered 70 ns trajectories established sustained odorant exit.

Our computational results

Entrance motion and odorant release are different readouts

Figure 19. Recorded 70 ns (nanoseconds, 10⁻⁹ seconds) trajectories for two starting conformations. Upper panels show the mismatch of S3/S6 (labels for the third and sixth membrane-spanning helices of OR10) ([6]) reference distances to apo (the odorant-free state) values; lower panels show odorant distance from the pocket (a local cavity in the receptor that can accommodate the ligand) center. Lines are 0.1 ns-bin medians for readability. Shading marks the final bias-removal interval. The full saved-frame analysis found no sustained exit; a decrease in entrance-distance error is not evidence of a passable tunnel.
Our computational results

Look at the structures saved during MD

Figure 20. Coordinates from one entrance-guided A trajectory, saved at 7.6, 27.6, 69 and 70 ns (nanoseconds, 10⁻⁹ seconds). All frames are aligned on OR10 (odorant receptor 10 from Aedes aegypti, the yellow-fever mosquito) ([6]) Cα (alpha-carbon atoms, used to trace the protein backbone) atoms to the first displayed frame and shown in one fixed projection at the same scale. Teal and purple highlight pocket (a local cavity in the receptor that can accommodate the ligand)-adjacent segments 117–139 and 281–299; orange shows actual o-cresol (2-methylphenol, the odorant resolved in 8V02) heavy atoms. The last frame follows bias removal. Local geometry changes while the ligand (a molecule that can bind to a receptor; here, the tested odorant) remains near the pocket. A two-dimensional projection cannot establish clearance, and selected snapshots do not show a continuous entry or exit path.

Molecular pathways

Computational evidence

From empty space to a molecular pathway

A point-probe corridor may exclude a finite, oriented odorant. We progressed to whole-ligand placement and flexible pulling; compare target and ligand motion, then inspect clashes and waiting tests for remaining obstacles.

Whole-ligand searches across 24 saved conformations found no low-clash complete route, and flexible pulling did not establish sustained exit through the two tested corridors.

1 · Map empty space

Point probes suggest candidate corridors.

2 · Place the whole ligand

Size and orientation expose clashes.

3 · Allow the environment to move

Flexible pulling still did not establish an exit.

Figure 21. Conceptual illustration, not a molecular trajectory or a validated tunnel. Green shapes represent the receptor environment, tan circles nearby lipids, and the orange shape the odorant. Candidate geometry, steric feasibility and observed passage are separate tests.
Our computational results

Candidate space before full-ligand testing

Figure 22. Candidate spherical-probe radius lower bounds from one guided trajectory, comparing 0.10 and 0.05 nm (nanometers; 1 nm = 10⁻⁹ meters) grids and protein-only versus protein-plus-lipid obstacles. Open triangles show finer-grid evaluations. Each obstacle model selects from the same candidate pool and may choose a different path. These are static centerline diagnostics, not observed ligand (a molecule that can bind to a receptor; here, the tested odorant) routes or independent timepoint experiments; grid sensitivity limits claims of a converged channel width.
Our computational results

Does the ligand follow the pulling target?

Figure 23. Recorded outward SMD (steered molecular dynamics: MD with an applied guiding force) ([16]) along two candidate corridors at two nominal target speeds. Time begins after the common 0.1 ns (nanoseconds, 10⁻⁹ seconds) baseline; lines are 20 ps (picoseconds, 10⁻¹² seconds)-bin medians. The target is held when lag or force becomes too large, producing plateaus. Target path arc, actual ligand (a molecule that can bind to a receptor; here, the tested odorant)–pocket (a local cavity in the receptor that can accommodate the ligand) distance and bias force are separate readouts: advancing the target did not establish ligand escape. The receptor and surrounding environment were flexible during these runs; applied force is not a measured natural exit barrier.
OR10–Orco: steered molecular dynamics of o-cresolComputational trajectory · 19.08 s
Video 5. Saved coordinates show o-cresol under steered molecular dynamics in OR10–Orco, with ligand–pocket distance and bias force. The target follows a lateral candidate route at a nominal 0.20 nm/ns; the 3.610 ns run ends without sustained exit and does not represent spontaneous dissociation.

Positive control: benzamidine displacement from trypsin

A successful displacement control gives the stalled OR10–Orco trajectory a useful comparison. In this trypsin–benzamidine pilot, the original binding pose is lost during guided MD and is not restored by the recorded endpoint after force removal.

Trypsin–benzamidine · guided MD positive controlEndpoint preview · 11.200 ns
Final saved frame of the trypsin–benzamidine positive-control pilot: displaced ligand, zero native atom-pair contacts and remaining protein contact after force removal.Watch on iGEM Video Universe ↗
Endpoint of the 11.200 ns positive-control pilot, with a nominal pulling-target speed of 0.20 nm/ns followed by force-free release. The video annotations report a ligand–site distance of 1.256 nm and zero native atom-pair contacts at the endpoint; the nearest protein distance remains 0.321 nm. This supports loss of the original pose under the tested forcing protocol, while contact with the protein remains. It does not establish complete unbinding, a natural dissociation rate or odorant-receptor activation.
Our computational results

Does a longer local wait relieve the obstruction?

Figure 24. The target was held fixed after lag developed in the slower pulling condition. This plot shows the extension from 0.5 to 2 ns (nanoseconds, 10⁻⁹ seconds) of total fixed-target waiting, at the original 2 ps (picoseconds, 10⁻¹² seconds) sampling. Catch-up requires both axial lag ≤0.20 nm (nanometers; 1 nm = 10⁻⁹ meters) and bias force ≤100 kJ/mol/nm (about 166 pN); orange diamonds mark individual frames meeting both. These brief events did not persist for 100 ps and no sustained exit was observed. Longer local waiting alone has not resolved the blockage in the tested window.
Our computational results

Do other receptor conformations open a route?

Figure 25. Peak positive Lennard–Jones (an atomic interaction potential; only its positive repulsive part is summed in our clash scans) repulsion along selected whole-ligand (a molecule that can bind to a receptor; here, the tested odorant) paths, including protein and lipids. Each starting structure contributes snapshots at the indicated times, evaluated separately in two corridors. Lower values mean fewer severe clashes in this diagnostic, not a validated passage. Even the lowest path peak is far above its native-pose reference; these are not free-energy barriers. Related snapshots are not independent experiments.

Discussion

The strongest predictive benefit comes from receptor sequence within a species. Measured infrared spectra, quantum modes and frozen odor embeddings do not provide a stable gain across models and cohorts, so richer molecular descriptions alone do not solve transfer. The mutation comparisons likewise depend on receptor context and matched evaluation.

The structural calculations add a second constraint: a wider entrance or an apparent geometric tunnel does not guarantee passage of a complete, flexible ligand. Protein and lipid obstacles, conformation choice and relaxation all affect the route. Prediction can prioritize a candidate, but functional change requires a matched receptor assay; geometric access requires a sustainable molecular path.

Receptor engineering / Conclusion

Conclusion

The study narrows receptor candidates with controlled prediction and structural comparisons. Sequence remains the useful predictive baseline, and whole-ligand tests constrain which access routes deserve further examination. The resulting candidates and routes are testable selections, rather than demonstrated improvements in receptor function.

Figure detail

Data availability

Research archive: Zenodo · DOI: 10.5281/zenodo.23469212. Public release pending.

Code, analysis scripts and reusable documentation are published in the official iGEM GitLab repository. Archive availability: Research archive availability.

Decoder data and code

The editable model manuscript preserves the current UCI/DoOR figures and settings; the engineering manuscript records the three redesign cycles. UCI-270 and DoOR are public source datasets. The older manuscript and four-feature NumPy MLP linked below document separate historical work.

Sources [18]

Methods and provenance
Numerical data and code

Receptor analysis files

Plotted values, out-of-fold predictions and pose-level outputs are retained with provenance and coverage manifests. The source handover identifies the supplied analyses; continuous water and lipid-tail coordinates are not available for every trajectory.

Methods and provenance
Figure and video files
Numerical data and code

Paired-response comparison and methods

Supplementary data

Optical methods and filter comparisons

D1–D4 use the CAD/channel registration shown in the model: D1 (−x, −y), D2 (+x, −y), D3 (+x, +y), and D4 (−x, +y), at 41, 67, 89, and 113 Hz, respectively. This fixes the labels across figures; bottom-view wiring orientation has not been independently checked against the assembled reader.

Optical geometry and sampling

The solver uses rectilinear material boundaries with Fresnel reflection and Henyey–Greenstein scattering. It represents a 7.5 mm² photodiode by a 3 × 2.5 mm equal-area detector, with separate excitation and emission packets. The main sweep contains 24 conditions, three seeds and 6,048,000 packets; seed variation measures numerical sampling uncertainty, not instrument calibration.

Sources [3]

Table 7. Monte Carlo sampling budgets for the optical sweep, floor irradiance, detector collection map and additional filter study. Variation among seeds estimates numerical sampling uncertainty; it does not calibrate the physical instrument.
CalculationSamplingInterpretation
Main optical sweep24 conditions × 3 seeds; 24,000 excitation + 60,000 emission packets / seed6,048,000 packets; seed variation estimates Monte Carlo sampling uncertainty
Floor irradiance600,000 excitation packetsSpatial illumination, not a measured light field
Collection map224 positions × 65,536 isotropic-source packetsFinite detector acceptance, not a detector calibration
Additional LED / filter study12 conditions × 3 seeds; 3,024,000 packetsPer-LED excitation rejection assumptions
Finite photodiode angular acceptance and sensitivity to the selected geometry
Figure 14. Detector-angle and geometry sensitivity under the idealized transport model. Do not interpret a datasheet half-sensitivity angle as an acceptance cutoff.
Archived alternative source distribution

The earlier uniform-volume sensitivity calculation used a 100 µL emitting volume and absorption coefficient 0.001 mm⁻¹. It is retained as an archived alternative, not the design model used in the primary Hardware / Model comparison. The canonical floor-layer matrix above is unchanged. Archived volume-source figure.

Spectral and noise assumptions

The LEE curve comes from vendor samples; stacked layers use transmission squared. The LED, green-emission proxy and OD4 edge are constructed spectra, while detector responsivity is digitized from a typical curve. Traces contain 8,000 samples over 2 s at 4 kHz with 25% duty. Joint fits retain four AC fundamentals; DC, PWM harmonics, analog transfer, ADC clipping and timing jitter are excluded. Sixty-four noise realizations test the analytic noise estimate, without propagating geometry, spectral or biological uncertainty.

Sources [4] [5]

Conditional fluorescence-change budget and lock-in noise target
Figure 16. Conditional photon-budget sensitivity. The archived calculation uses quantum yield 0.6 and cell-layer absorption coefficient 0.5 mm⁻¹. All plotted quantities are positive, so the logarithmic scale runs from white to red. Changing quantum yield, optical power or fluorescence change changes the target. The SNR = 5 contour is a modeled noise threshold, not a measured device detection limit.
Gas and liquid transport methods

Gas-surface calculation

The confirmed fill is 100 µL per well. Printed brim capacity is estimated at approximately 120 µL; nominal CAD capacity remains 140 µL, so the capacity estimate does not define a replacement geometry. The first gas-cell centers are 0.2 mm above the nominal liquid surface on the 0.4 mm grid. The liquid has zero uptake; external tubing and cell response are excluded. The 26 cases comprise 21 flow–diffusivity combinations, two geometry controls and three numerical checks. The largest relative global mass residual is 9.13 × 10⁻¹².

Table 8. Nominal first-gas-layer arrival times: Q = 3 mL/min, D = 10 mm²/s, 100 µL per well, 0.4 mm grid and 0.25 s time step. Symmetric pairs follow the nominal geometry.
Wellt10 (s)t50 (s)t90 (s)
D36.2918.2449.42
D45.3016.6647.80
D15.3016.6647.80
D26.2918.2449.42

Geometry and operating-band checks

The earlier 0.6–1.4 mm sampling band is distinct from the current first-layer surface calculation. Its operating sweep contains 28 combinations of seven flows and four diffusivities (5, 10, 15 and 20 mm²/s). At 3 mL/min it gives approximately 50.00 s worst-well t90, 0.00280 mm/s near-liquid P95 speed and 0.02737 Pa chamber pressure drop. These values exclude external tubing and filters. Shelf momentum reduction changes from 30.9% to 30.1% to 36.1% across 0.4, 0.3 and 0.2 mm grids; local flow metrics are not grid independent.

Sources [6] [7]

Velocity and momentum comparison of open, perforated and shelf gas-path designs
Figure 17. Simulation · gas-lid geometry screen. This figure compares 18 deterministic geometry cases on the original 0.4 mm grid: worst downward-momentum proxy, near-liquid P95 speed normalized to the open design, and pressure loss. Cases are design alternatives, not statistical replicates; no Monte Carlo seeds or error bars apply. The separate shelf/open refinement gives momentum reductions of 30.9%, 30.1% and 36.1% at 0.4, 0.3 and 0.2 mm respectively, so grid convergence is not established. All cases use the nominal CAD gas space with a 100 µL fill. Data availability.
Near-liquid gas-concentration wash-in in the selected shelf geometry
Figure 18. At 1 mL/min and Dgas = 10 mm²/s, the D3 baseline t90 is 149.55 s. Gas concentration at the liquid interface is distinct from concentration at bottom-attached cells.
Discrete gas delivery-time and near-liquid speed tradeoff for sampled flows
Figure 19. Fixed-CAD flow/diffusivity study. Gas diffusivities 5/10/15/20 mm²/s are uncertain material assumptions; the candidate is the lowest qualifying sampled flow, not a global optimum.
Perforated geometry sensitivity with two refined cases
Figure 20. Exploratory six-hole sweep. This is a comparison set, not an alternate selected print or proof of a global optimum.
Three-dimensional scatter of 28 computed flow and diffusivity conditions, with worst-well gas arrival time
Figure 21. Twenty-eight computed operating-band conditions across seven flows and four assumed diffusivities (5, 10, 15 and 20 mm²/s). The three-dimensional scatter shows worst-well gas t90 in the 0.6–1.4 mm sampling band above the liquid. It is separate from the current first-gas-layer surface calculation.
Open plenum, perforated plate and integral shelfOriginal simulation · 20 s
Video 3. 60 physical seconds in 20 seconds of playback. Panels A–C advect saved velocity markers in the open, 12-hole and selected-shelf gas geometries at the 1 mL/min baseline. Marker density is not concentration. Panel D independently plots finite-volume gas concentration for the shelf with Dgas = 10 mm²/s. The liquid remains a stationary boundary; no liquid mixing or cell motion is simulated. This is not a movie of the later 3 mL/min candidate. Data availability · Data availability.
Table 9. Operating-band comparison at the 3 mL/min candidate. These values sample 0.6–1.4 mm above the liquid; current first-layer results and checks are reported separately above.
MetricComputed resultDeclared criterion / boundary
Worst near-liquid gas t9050.00 s≤60 s across four wells and four gas-diffusivity assumptions
Refined grid / half time step50.98 s / 49.85 sNumerical checks at the chosen candidate
Near-liquid gas P95 speed0.00280 mm/s≤0.01 mm/s engineering comparison cap; not a cell-injury threshold
Port Reynolds number1.77≤3 in the declared comparison
Chamber pressure drop0.02737 PaExcludes external filters and tubing
Nearby 2.5 mL/min pointWorst t90 ≈60.04 sNumerically borderline; not proven physically inadequate

Membrane assumptions

The layer equation is K ∂u/∂t = ∂(DK ∂u/∂x)/∂x, with gas-equivalent concentration u and material concentration c = Ku. It assumes dilute linear transport, instant interfacial partitioning, uniform area and no convection, reaction or cellular consumption. The 243-condition sweep varies membrane thickness, diffusivity and partition coefficients; 74 cases do not reach t90 within seven days. A 20-minute pulse gives a delayed 2.78% peak after 3.92 h in the illustrated case.

Sources [8]

Modeled pulse response and delayed liquid transport under generic material assumptions
Figure 22. Transient storage and delayed delivery are consequences of the stated transport model; they are not biological measurements.

Numerical checks reproduce the analytical membrane time lag within 0.00305% and liquid-bottom t90 within 0.000762%. Refining the coupled liquid mesh from 48 to 96 cells changes t90 by 0.00405%; the largest normalized mass-balance residual is 2.17 × 10⁻⁵. These checks test the solver, while target-specific material properties remain separate inputs.

Validation comparisons

Physical validation pairs

The validation matrix pairs each calculation with an independent measurement: a calibrated fluorescence standard for optical collection, illuminated blanks for demodulation, assembled-path concentration histories for gas arrival, and a cell-plane time course for liquid delivery. Numerical verification tests the calculation; these paired measurements test the apparatus.

Table 10. Numerical optical, demodulation and transport predictions are paired with the physical measurements needed for validation. The table contains proposed validation pairs, not fitted experimental results.
PredictionAvailable evidenceRequired paired observation
Optical collection: D3 0.593 ± 0.035 nW under the stated referenceMonte Carlo outputs and convergence checksTraceable fluorescence standard, actual filter spectrum and photodiode calibration in the same geometry
Synthetic demodulation: residual amplitude bias 2.63–3.52%Generated interference and host-tested analysisIndependent illuminated blank and reference recordings, including saturation and drift
Gas candidate: 3 mL/min; worst first-layer t90 50.024 sNominal CAD geometry and confirmed 100 µL fillMeasured well capacity, assembled-path flow and gas-interface time course
Stagnant liquid: bottom t90 22.83 h at 100 µL, D = 10⁻⁹ m²/sIdealized diffusion calculationConcentration time course at the cell plane under verified depth and mixing

Capture hypotheses

No reproducible target-specific capture-protein calculation is supplied in this hardware release. Docking can propose poses or compare scores within one model; it does not measure affinity, uptake, receptor activation or resolution of liquid-delivery limits.

Liquid and capture decisions

The no-film build establishes the baseline before testing membrane selectivity, recovery and carryover. Any capture-protein proposal requires a defined protein–ligand pair and measured uptake and release; neither decision follows from gas wash-in alone.

Table 11. Material and capture comparisons, with the measurement needed for each design decision.
QuestionEvidenceDecisionRemaining measurement
Should a membrane be part of the current build?Gas–liquid transport and conditional membrane sensitivity; no measured target-specific permeabilityKeep the current enclosure without a film; establish the no-film baseline firstDefined-molecule arrival and recovery at the cell plane, then measured film selectivity and carryover
Does a capture protein speed cell exposure?No target-specific uptake or binding records supplied in this packageRetain a separately labeled hypothesisIdentify protein and ligand; measure uptake and release
Current UCI and DoOR model parameters

These are the settings reported for the UCI analysis in the model source. They are simulation specifications, not values fitted to the AeroSense reader. Integer clipping described in the source is an implementation specification; device validation is not supplied.

Network size reconstructed only from explicitly stated population counts.
PopulationUCI setting
PN400 (20 PCA components × 20 quantile bins)
KC2,000
APL1
MBON / teacher6 / 6
Neuron settings from the model record; units and bounds are preserved.
SymbolMeaningValueRange / limits
CMembrane capacitance300 pF—
g_LLeak conductance30 nSMembrane time constant C / g_L = 10 ms
E_LResting potential−70 mV—
VMembrane potentialStarts at −70 mVPhysically bounded by E_GABA and E_AMPA (−80 to 0 mV); the integer engine clips V to this range
V_thFiring threshold−40 mVFixed for PN, APL, MBON and teacher; adaptive for KCs (below)
V_resetPotential after a spike−60 mVRefractory period 1 ms
E_AMPA , τ_AMPAExcitatory reversal potential and decay0 mV, 2 msg_AMPA ≥ 0
E_GABA , τ_GABAInhibitory reversal potential and decay−80 mV, 5 msg_GABA ≥ 0
xSpike trace used by plasticity+0.1 per spike, decays with τ_x = 10 msDimensionless, x ≥ 0
KC intrinsic-plasticity settings.
SymbolMeaningValueRange / limits
V_th(0)Initial KC threshold−40 mV—
V_min , V_maxThreshold limits−60 mV, 0 mVV_th always stays within [−60, 0] mV
ηIP learning rate (threshold rise)0.015 ms⁻¹0.005 ms⁻¹ × IP factor 3 ( ip = 3)
κRecovery rate (threshold fall)1 × 10⁻⁴ ms⁻¹Acts only while the KC is silent (x < 10⁻⁶)
Connection weights and learning settings.
ConnectionReceptorWeight per synapseLimits / learning
PN → KCAMPARandom, then scaled so that each KC’s inputs sum to 800 nS (about 5 inputs of ~160 nS; p_pn_kc = 0.0125)Fixed
KC → APLAMPA30 nS (all KCs)Fixed
APL → KCGABA60 nS (all KCs; w_apl_kc )Fixed
KC → MBONAMPAEach KC’s 6 outputs sum to 10 nS ( w_kc_mbon )Each synapse within [0, 10] nS; STDP adds up to 0.0125 nS per KC–MBON spike pair ( learning_rate ; τ_pre = τ_post = 5 ms); outputs re-normalized after every training exposure
Teacher → MBONAMPA1,500 nS (one-to-one)Training only
MBON → teacherGABA200 nS (one-to-one)Silences the teacher once its MBON fires
MBON ↔︎ MBONGABA2,000 nS between different MBONs ( lateral )Fixed
Input and presentation schedule.
ItemSetting
Odor input2.05 nA injected into the 20 active PNs for 30 ms
Teacher input10 nA into the teacher neuron of the correct gas, starting 1 ms after odor onset (training only)
Exposure timing30 ms exposure followed by a 3 ms gap
TrainingUp to 800 cycles; each cycle presents every gas once (6 exposures); tested after every 100 cycles
Testing300 exposures per gas (1,800), with all learning frozen

DoOR changes: 1,000 KCs; six PCA components; APL→KC 30 nS; intrinsic-plasticity factor 2; learning step 0.025 nS; five MBONs and teachers; 50 test presentations per class. Twenty equal-width bins use PN→KC probability 0.05 and 200 training cycles. Five quantile bins use probability 0.2 and 100 cycles.

Biological pathway schematic
Original conceptual pathway illustration produced with OpenAI image generation and reviewed by the team; it is not an anatomical reconstruction
Figure S21. Original conceptual pathway illustration produced with OpenAI image generation and reviewed by the team; it is not an anatomical reconstruction. Sensory neurons project to the antennal lobe; PNs reach the mushroom body and lateral horn. The modeled route follows PNs to KCs and MBONs; the lateral horn is not modeled. AI assistance and team review.
Earlier KT/UCI decoder analysis and figures S1–S17

This retained analysis uses earlier datasets, settings and splits. Its KT five-gas scores, drift studies and precision audit are historical evidence, not results of the UCI/DoOR comparison above. Original figure destinations remain available.

Odor decoding / Summary

Odor recognition under sensor change

A fly-inspired PN–KC–MBON network classifies KT metal-oxide recordings with random-split five-fold macro-F1 0.87 ± 0.03, decreasing to 0.73 on unseen days. Layerwise probes localize the largest measured loss to the learned readout. On an independent 36-month UCI corpus, reference-gas correction raises cross-batch SVM accuracy from 33% to 58%.

The results identify collection-day dependence and loss at the learned readout in the tested metal-oxide benchmarks.

ODOR DECODING / INDEPENDENT BENCHMARK

From sensor patterns to neural computation

The following study uses KT and UCI metal-oxide sensor recordings, independently of simulated optical traces and AeroSense biological measurements.

Conceptual network from sensor features through PN-like coding, sparse KC activity and MBON-like classification
Figure S1. Model architecture. Public metal-oxide sensor data provide the current benchmark for this fly-inspired classifier.
Odor decoding / Evidence

The decoder loses accuracy on unseen days

We test information loss, unseen-day performance and reference-gas correction. The newer five-fold study extends the single-run benchmark; its parameter sweep retains a separate 0.868 reference. These metal-oxide studies are independent of the reader simulations and HEK293 experiments.

The clearest current bottleneck is the readout: the KC representation remains highly separable, but the present local learning rule does not recover all of that information. A second finding changes experimental design: measurement day and gas identity must be disentangled before a drift claim is credible.

Odor decoding / Introduction

The challenge: sensor drift

Electronic noses combine cross-sensitive chemical sensors with pattern recognition. Aging, poisoning and environmental changes can shift the response to the same analyte, weakening a classifier trained on earlier measurements. Calibration samples, ensembles and adaptation can reduce this loss, at the cost of additional measurements or assumptions about the shift. [1] [2]

We tested sparse neural representations and a locally learned readout using pooled classification and unseen-day SNN evaluation. The separate long-term drift analysis uses conventional classifiers.

Odor decoding / Introduction

Why borrow fly-brain computation?

Can sparse expansion make overlapping sensor responses easier to classify? The circuit diagram separates representation from learned output and training-only teacher signals from test inputs, preparing the later layerwise comparisons.

Follow an odor pattern through projection neurons, a sparse Kenyon-cell ensemble and a learned MBON readout. Compare training with testing, then explore the implemented network and its evidence below.

Explore the circuit

Encode → sparsify → learn the readout

Conceptual walkthrough
Odor input activates PN neurons; expansion leaves sparse KCs; learned connections drive the MBON class output. A teacher stimulates the matching MBON during training and is removed during testing.
Receptors / outputPN / learned pathsActive KCsTeacher
Several channels respond to the same odor

PN activity expands into a sparse KC ensemble. During training, the Answerₚ teacher stimulates its corresponding MBON; testing removes the teacher and reads the learned output.

PN: projection neuron · KC: Kenyon cell · MBON: mushroom body output neuron. Filled nodes are active; open nodes are inactive.

Each animation stops after one pass. Reduced-motion settings start with a still view. Step and teacher buttons also work without playing motion.

Figure S2. Interactive teaching diagram adapted from the team’s circuit prototype. The fixed example illustrates encoding, sparse KC activity and a training-only Answerₚ → MBON teacher signal. Node activity and connection highlights are scripted, not recorded spikes, fitted weights or a live simulation. The animation’s 5 PNs, 28 KCs and 3 MBONs are illustrative; the implemented decoder uses 160 PNs, 1,000 KCs, 1 APL and 5 MBONs. APL inhibition and threshold adaptation are explained in the network methods rather than drawn here. The same-pattern replay explains teacher removal; it is not a held-out classification result.
Two odor inputs in a simulated PN–KC circuitCircuit simulation · 10.84 s
Video 4. Two odor inputs, each activating 20 projection neurons, drive a leaky integrate-and-fire PN–KC simulation on Hemibrain anatomy; rasters show simulated KC spikes. This circuit illustration is separate from calcium imaging and the AeroSense decoder benchmark.
Biological rationale and implementation mapping

In Drosophila, projection neurons (PNs) relay olfactory information from the antennal lobe to Kenyon cells (KCs). Sparse PN→KC connectivity expands the representation; feedback from the anterior paired lateral (APL) neuron constrains KC activity. Mushroom body output neurons (MBONs) read this activity through synapses shaped by learning. [3] [4] [5] [6]

This organization suggests a practical division: keep a random feature expansion fixed, regulate its activity, and learn a small readout. Related motifs support similarity search and insect-inspired chemical classification. [7] [8] [9] The contribution of expansion depends on input statistics, connectivity and sparseness. [10] [11]

Table 3. Biological circuit motifs, their implementations in the simulated decoder and the engineering questions tested. The mapping is a modeling abstraction rather than a literal reconstruction of a fly circuit.
MotifImplementationQuestion
PN→KC expansionFixed random links into 1,000 KCsDoes useful class information survive encoding?
APL and intrinsic plasticityGlobal inhibition and adaptive KC thresholdsCan activity remain sparse across inputs?
KC→MBON readoutLocal potentiation with weight normalizationCan learning use the information in KCs?
Learning in stagesAdd one gas after four othersHow much earlier performance is retained?
Network schematic with PN, KC, APL, MBON, teacher, and proposed ALLN and DAN pathways
Figure S3. Network architecture. The reported experiments use PN, KC, APL, MBON, MBON inhibition and a training-only teacher. ALLN activation/inhibition in the full schematic is inactive in these experiments. The DAN pathway remains under development; its presence in the drawing is not evidence of a completed dopamine-learning result.
Odor decoding / Methods 01

Turn an exposure into model input

Encoding must be consistent and exclude test-set information. Follow each exposure from sensor features to neural input, then compare overlapping patterns in the gas-by-sensor heatmap with later classwise errors.

Inputs
External metal-oxide exposures
Method
Train-only preprocessing, PCA and bin encoding
Output
Versioned PN input patterns
Decision
Separate data splitting from sampling trials

The KT Batch 1–3 corpus contains 8,366 cleaned exposures from a 14-channel metal-oxide array. Five devices were measured over 95 acquisition days. Known faulty Batch 2 devices 1–2 were excluded, approximately 13% of the raw recordings. Four concentrations per gas and four humidity levels provide variation within the five classes.

Each KT exposure becomes a train-fitted input pattern. KT and UCI use different sensors, gases and preprocessing, so their scores remain separate.

Sensor traces, response extraction, PCA, PN encoding, and repeated SNN training
Figure S4. Computational workflow. A static response vector is extracted from each exposure, then presented to the network for 30 ms of simulated time. This is not the physical gas-exposure duration. Learning combines KC threshold adaptation, spike-pair updates and weight normalization.
Five gas response profiles across fourteen KT sensors
Figure S5. Median peak response by gas and sensor across 8,366 KT exposures, expressed in each sensor’s spread units for visualization. NO₂ has distinct response directions, while toluene and ethanol have similar profiles. These summaries motivate the confusion analysis but do not measure classifier performance.
Odor decoding / Methods 02

Network dynamics and the learned readout

We separate expansion, inhibition and readout learning so that errors can be traced to the representation or its learned output.

The model expands PN inputs into sparse KC activity, then trains the KC-to-MBON readout with a correct-class teacher. Testing disables the teacher and learning; this is a computational abstraction of olfactory circuitry.

Odor decoding / Methods 03

Keep the three evaluation splits separate

Random exposure splits test separation within the collection; whole-day holdouts test unseen collection conditions. Both differ from the chronological UCI analysis. Preprocessing is fitted within each training partition.

KT evaluation uses five folds under two strategies. A gas-stratified random split mixes measurement days across training and testing. A whole-day split keeps each day intact, so test days are unseen. Imputation, scaling where applicable, PCA and bin edges are fitted to training data. Training comprises 300 cycles, each presenting every gas once; testing uses fifty presentations per gas with frozen learning.

The corpus unit is an exposure; a sampled presentation is a simulation trial. Repeated draws from an exposure do not create independent measurements. Macro-F1 is the unweighted mean of classwise F1 scores; accuracy is the fraction classified correctly. The metrics remain distinct throughout.

Table 4. Dataset, split and reporting unit for each decoder evaluation. Fold summaries, held-out exposures and sampled simulation presentations are distinguished, and macro-F1 is not interchangeable with accuracy.
StudyDataset / splitReported scale
Main SNN comparisonKT random / whole-day five-foldFold means; random macro-F1 0.87 ± 0.03
SensitivityKT one random split; one run per setting250 sampled test presentations; baseline F1 0.868
Layer diagnosisKT one common random split6,692 train / 1,674 held-out exposures
Offline readout rulesUCI KC representations; five foldsMacro-F1; mean and fold spread
Reference calibrationUCI train Batch 1, test later batchesAccuracy averaged over Batches 2–10
Continual learningKT four gases, then NH₃ onlyOne run; fraction correct per class
Odor decoding / Results 01

Classification varies across five gases

An overall score can conceal repeated class confusion. Compare the confusion matrix with sensor-response patterns, then use spike rasters to trace example decisions; the rasters explain dynamics rather than estimate accuracy.

Under stratified random five-fold evaluation, KT mean macro-F1 is 0.87 with reported variation ±0.03; the source separately reports approximately 88% accuracy. This extends the earlier single-run 0.868 baseline without implying an identical seed or test partition.

The dominant error is toluene → ethanol

In the illustrated classwise result, NO₂ recall is 98%. Toluene recall is 60%, with 24% assigned to ethanol, consistent with their similar sensor profiles. The illustrated F1 scores are SO₂ 0.88, NO₂ 0.93, toluene 0.73, ethanol 0.83 and NH₃ 0.83; these are not the five-fold class means.

Per-class SNN F1 and confusion matrix showing toluene misclassified as ethanol
Figure S6. Classwise performance and confusion. Rows are true classes and columns predicted classes; percentages are row-normalized. Grey bars are an empirical RBF-SVM probe of KC activity, not a proven upper bound. The KC code supports toluene F1 near 0.96, motivating readout diagnosis.

A sparse response precedes the decision

Eight PN units receive current per KT exposure. KC activity is initially stronger, then APL inhibition suppresses it after approximately 5 ms; the source reports about 11% active KCs on average. Four of the five illustrated trials are correct, while toluene is classified as ethanol. These examples explain dynamics rather than provide an independent accuracy estimate.

PN, KC and MBON rasters for one exposure from each gas
Figure S7. Spike rasters over 30 ms for one example per gas. Sparse KC responses and competing MBON activity are visible, including a toluene-to-ethanol error.
Odor decoding / Results 02

Unseen days expose a generalization gap

Keeping measurement days intact tests reliance on shared collection conditions. Compare random and unseen-day bars before attributing their difference to a particular drift mechanism.

Unseen days reduce macro-F1 to 0.73

Gas identity is strongly associated with the 95 KT measurement days: almost every day contains only one gas, and no day has more than two. Random splitting can share day-specific conditions across training and test data. Keeping days intact is more stringent: SNN mean macro-F1 decreases from 0.87 to 0.73.

Compare classifiers under the same split question

Table 5. Five-fold KT macro-F1 comparison for three classifier/input combinations under random-exposure and whole-day splits. The whole-day split tests transfer to held-out measurement days; these are proxy sensor-array results.
Classifier / inputRandom macro-F1Whole-day macro-F1
RBF SVM / eight PCs0.990.90
Linear SVM / PN code0.960.84
SNN / MBON output0.870.73

Figure 8: Compare the random and unseen-day splits on the same metric before attributing the loss to drift.

Five-fold random-versus-whole-day macro-F1 for three classifiers
Figure S8. Bars are five-fold means; lines show source-reported fold spread, without a specified SD/SE definition. SNN loses about 0.14 macro-F1; the SVM comparisons lose about 0.09 and 0.12. This is not a chronological SNN drift evaluation.

Design consequence. Whole-day holdout exposes day-dependent variation that pooled splits conceal, although it does not isolate aging from concentration, humidity or collection changes.

Sensitivity identifies parameters worth controlling

The one-factor sweep tests sensitivity around the earlier reference. Departures from the dashed line identify parameters worth controlling, not an independently confirmed optimum.

A one-at-a-time sweep varies parameters around the selected KT setting. Most changes of approximately 30–50% alter macro-F1 by less than 0.05. The KC→MBON weight limit and PN bin count have the largest effects; halving KC threshold adaptation decreases F1 by approximately 0.07. Each setting has one run and 250 sampled test presentations, so small differences need repetition before being called improvements.

Single-run parameter sensitivity relative to 0.868 macro-F1
Figure S9. The dashed line is the earlier single-run 0.868 reference. The plot’s approximate ±0.02 sampling-noise annotation is a heuristic, not a documented confidence interval. Parameter sensitivity does not replace controlled ablations or temporal testing.
Odor decoding / Results 03

The readout is the main bottleneck

Errors may reflect upstream information loss or an inadequate learned output. Compare conventional probes across representations on a common split, then with MBON output, to locate the loss.

Conventional probes were trained on sensor, PCA, PN and KC representations using the same 6,692 training and 1,674 held-out KT exposures. RBF-SVM scores remain about 0.99 on raw sensor features and PCA, and 0.97 on PN and KC codes. The learned MBON output scores 0.84 in this diagnostic split: a 0.13 gap from the KC probe.

Figure 10: Layer probes distinguish representation quality from the learned MBON readout.

Layerwise classification scores from sensor features through MBON output
Figure S10. Common-split diagnosis. Nonlinear probes remain strong through KC activity, while the learned MBON stage loses 0.13 macro-F1. The 0.84 diagnostic result is distinct from the five-fold headline 0.87.

Linear-probe F1 improves only slightly from PN 0.96 to KC 0.97. Restricting a KC classifier to the 1,355 unique exposures actually encountered by sampled SNN training still gives about 0.95. These comparisons prioritize the learning/readout stage without proving that every upstream choice is optimal.

Error-driven readout comparison

To test the readout diagnosis, we fixed the KC representation and varied only the output rule. Compare averaging, error-dependent updates and a linear classifier using the same information.

Offline UCI tests hold KC representations fixed. The current Hebbian rule with normalization reaches about 0.81 macro-F1; class averaging gives 0.80, adding depression after wrong answers gives 0.82, and error-driven variants reach 0.84–0.85. A linear-SVM probe reaches 0.89. Dopamine-dependent mushroom-body learning motivates error-sensitive updates, but biological reinforcement is more heterogeneous than a single correction signal. [12] [13] [14]

Five-fold UCI comparison of Hebbian, depression, error-driven and SVM readouts
Figure S11. Offline readout comparison: five-fold means and reported fold spread. The plot’s “best any linear readout can do” label denotes the tested linear-SVM benchmark, not a mathematical bound. The improved offline rules have not yet shown the same gain in the full spiking network.
Odor decoding / Results 04

Drift changes response patterns

The separate UCI batches test long-term gain changes and classification loss. Read sensor traces before their common and gas-dependent components: a shared correction may not fit every sensor–gas pair.

UCI concentration-corrected gain is compared with Batch 1 on a log₂ scale: +1 is a twofold gain and −1 a halving. For most gases, the median response gain across the sixteen sensors is about 1.2–2.3 times the initial value in Batches 2–9; by the 36-month batch, all six gas medians fall below their initial level. Four TGS2602 sensors differ from the other twelve: acetaldehyde, acetone and toluene responses become approximately 4–11 times weaker from Batch 2; one response is nearly silent around months 21–23. Drift depends on gas and is larger at low concentrations.

Concentration-corrected log-two gain across ten UCI batches
Figure S12. Thin traces denote individual sensors and blue denotes their median. Missing gas–batch combinations remain absent. This is a characterization of the dataset, not an SNN accuracy result.
Table 6. Reported shares of the UCI drift decomposition across all 128 features. Global, sensor-model, individual-sensor and gas-by-sensor components show why a single reference gas cannot identify every gas-specific change.
ComponentShareReference-gas interpretation
Global shift7%Shared factor
Sensor-model shift55%Model-specific factors needed
Individual sensor7%Sensor-specific factors needed
Gas × sensor31%Gas-specific changes across the panel
Global, sensor-model, individual-sensor and gas-specific drift contributions
Figure S13. Drift decomposition for ΔR and all 128 features; total RMS log₂ gain is shown above each bar. The shared components sum to 69%, suggesting a reference-gas correction opportunity under this decomposition. It is not a measured 69% accuracy recovery.

Aging and concentration coverage both matter

The curves compare training-batch choice and test-concentration coverage, separating within-batch classification from between-batch transfer rather than estimating a single drift penalty.

Within-batch SVM accuracy is about 99%. Training on Batch 1 and testing later batches gives about 33% mean accuracy; training on the preceding batch gives about 71%. More than 90% of Batch 10 samples fall outside Batch 9’s concentration range. Restricting comparisons to in-range concentrations changes several results, so the unrestricted loss cannot be attributed entirely to sensor aging.

Chronological UCI SVM accuracy under two batch-training settings
Figure S14. Within-batch, unrestricted cross-batch and concentration-matched curves answer different questions. The plotted preceding-batch study excludes 467 samples of a gas absent from its training batch; class coverage therefore also affects comparison.

Ten ethanol measurements recover part of the loss

Can one reference gas help classify the others? Compare its correction with global and per-sample normalization. The gas-specific comparator uses extra information and is not an ethanol-only outcome.

Ten ethanol references per new batch, with separate feature corrections, raise mean Batch 1→later-batch SVM accuracy from 33% to 58%. This recovers 25 of the approximately 66 percentage points separating the uncorrected score from the within-batch reference. A global correction gives 34%, and normalizing each sample gives 43%. Related domain-adaptation methods likewise use labeled target-domain samples. [15]

Figure 15: The UCI reference-gas comparison separates ten-ethanol-reference correction from the optimistic gas-specific comparator.

UCI accuracy: 33% uncorrected, 34% global, 43% sample-normalized, 58% ethanol feature correction, 88% gas-specific, 99% within-batch
Figure S15. Mean SVM accuracy over Batches 2–10. The practical reference condition uses ten ethanol measurements from each new batch. Gas-specific correction uses extra information about every gas; its 88% is an optimistic comparator, not an ethanol-only result or a universal upper bound.

The reference-gas correction recovers part of the conventional classifier’s cross-batch loss. This is an SVM calibration result, not evidence of inherent SNN drift resistance.

Odor decoding / Results 05

New-gas learning trades off retention

We tested whether learning a new gas disrupts earlier classes. Read old- and new-gas fractions together; success on the added class alone would conceal forgetting.

Sequential learning can interfere with earlier knowledge. [16] In an initial KT experiment, the network learns four gases and then receives ten cycles of NH₃ alone, without rehearsal of the old gases.

Single-run class recognition before and after NH3-only training
Figure S16. One sequential-learning run. NH₃ recognition changes from 0% to 72%; SO₂ 80%→72%, NO₂ 94%→90%, toluene 80%→76%, ethanol 84%→74%. These are fractions correct per class, not macro-F1.

The four old classes lose 4–10 percentage points while retaining most of their initial performance in this run. The discussion considers the role of representation overlap.

The teacher schedule prevents the proposed error signal

The implemented dopamine-inspired rule weakens connections to a wrong MBON, but that event did not trigger: the correct teacher acted early and inhibition suppressed competing responses.

Odor decoding / Discussion

Discussion

The practical lesson is to vary collection conditions independently before replacing the classifier. Record gas, device, concentration, humidity and day; interleave gases within days; evaluate feature-specific reference correction; and compare readout changes on fixed exposure partitions before increasing network size.

The HEK293 observations and the external sensor-array benchmarks are separate datasets. Results contains the acquired biological measurements.

The source describes integer arithmetic, but the released figures report simulation benchmarks without a corresponding embedded timing, memory or power measurement.

  1. 01 Measure

    Wet Lab / sensing layer produces a response (today: KT surrogate; target: AeroSense receptor fluorescence features).

    Sense · Wet Lab
  2. 02 Encode

    Hardware measurement path (or archived sensor export) turns the measurement into a versioned feature vector.

    Measurement · Dry Lab · Hardware
  3. 03 Model

    Fly-inspired SNN maps features → class scores (this page).

    Odor decoding · Dry Lab · Model You are here
  4. 04 Evaluate uncertainty / error

    Splits, seeds, ablations, drift tests, per-class errors — only where archived.

    Classification · Evaluation
  5. 05 Change design

    Update sensing panel, measurement quality, or model hyperparameters — only from validated evidence.

    Act · Design change
  6. 06 Measure again

    Close the loop with a new assay / export (EXP-AS-07 path when available).

    Sense · Wet Lab
Figure S17. Feedback loop linking Wet Lab and Dry Lab (Hardware | Model). No closed AeroSense fluorescence → Model → redesign cycle is claimed yet; KT work develops odor-classification methods on a surrogate aging corpus.

Dataset provenance: “KT” is the label in the team analysis record; its expansion, thesis author, institution and stable source have not been recovered. The KT scores rest on a corpus readers cannot presently obtain from this release. The separately cited UCI dataset is publicly retrievable. No decoder score on this page is measured AeroSense cell performance.

The fold plots label their uncertainty as “spread”; the source does not specify whether ±0.03 denotes standard deviation or another statistic. We therefore report fold variation, not a confidence interval. New-run seeds, fold assignments and machine-readable predictions are not included. Parameter sweeps selected settings, but a separate nested selection protocol is undocumented; these estimates do not establish performance on a completely untouched deployment population.

KC overlap was not quantified in the continual-learning run, so the contribution of representation overlap to retention remains a question for controlled ablation.

This one-factor sensitivity study is exploratory. The related weight refinement was jagged and non-monotonic, and its best fixed-seed value remains gated. The companion state-precision experiment was invalidated by a clock-scheduling error; it is not a valid precision result. Read the invalidation and exact scope · Inspect the engineering record.

Odor decoding / Conclusion

Conclusion

Whole-day evaluation reveals losses that random exposure splits conceal. Layerwise probes locate the largest measured loss at the learned readout, and reference calibration improves cross-batch classification only with suitable gas and concentration coverage. For AeroSense, the supported next design choice is controlled acquisition and evaluation before increasing network complexity.

Earlier KT/UCI methods, figures S18–S20 and reproducibility record

The settings below belong to the earlier record. They do not replace the current 400-PN/2,000-KC UCI configuration or the DoOR settings above.

Dataset and network methods

Preprocessing and encoding

Each KT exposure is referenced to the preceding clean-air baseline. Fourteen signed delta-peak features undergo train-only median imputation and eight-component PCA without peak standardization. Each PCA axis is divided into 20 training-range bins, giving 160 PN units with eight active inputs. UCI uses its own standardized features and twenty PCA components. Concentration ranges and the input plots appear below.

Sources [17] [18] [19]

Table 12. Gas concentration ranges represented in the five-class KT metal-oxide sensor dataset. These dataset ranges are not the concentrations used in AeroSense cell assays.
ClassRange
SO₂10–100 ppm
NO₂2–20 ppm
Toluene1–10 ppm
Ethanol5–40 ppm
NH₃2–20 ppm
KT exposures in three principal components, with one gas highlighted per panel
Figure S18. KT PCA projection. Gas panels share viewing angle and axis ranges. Toluene and ethanol occupy nearby regions; NH₃ is more dispersed. Explained variance summarizes the projection shown, not classification performance.
Standardized UCI exposures projected onto three principal components
Figure S19. UCI PCA projection with extreme display positions omitted. Concentration changes tend to extend each gas along a response direction, while batches can occupy different directions. The twenty-component UCI configuration is distinct from the eight-component KT configuration.
Eight active bins across eight KT components and twenty bins per component
Figure S20. PN encoding for representative NO₂, toluene and ethanol exposures. Each row selects one of twenty bins. This is a feature code inspired by a projection-neuron representation, not a reconstruction of individual fly glomeruli.

Network parameters

Brian2 integrates conductance-based neurons at 0.1 ms. The circuit contains 160 PNs, 1,000 KCs, one APL and five MBONs. PN→KC probability is 0.05, with 800 nS total incoming weight per KC; both APL directions use 30 nS. KC→MBON spike pairs potentiate by at most 0.025 nS, followed by normalization to 10 nS outgoing weight per KC. The correct-class teacher operates only during training. Equations and all neuron, connection and timing values are preserved in three complete parameter tables.

Sources [20] [21]

Table 13. Membrane, synaptic and threshold-adaptation parameters used in the simulated neurons. Values are settings from the team Model record; no fit to AeroSense measurements or row-specific literature derivation is archived.
ParameterValueScopeSource / selection basis
Capacitance C300 pFAll neuronsData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Leak gL / reversal EL30 nS / −70 mVMembrane time constant 10 msData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Threshold / reset−40 mV / −60 mVKC threshold subsequently adaptsData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Refractory period1 msAll neuronsData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Excitatory reversal / decay0 mV / 2 msAMPA-like currentData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Inhibitory reversal / decay−80 mV / 5 msGABA-like currentData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
KC trace+0.1 per spike; τ = 10 msThreshold adaptationData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
KC threshold bounds−60 to 0 mVInitially −40 mVData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
KC η / κ0.01 / 0.0001 ms⁻¹η = 0.005 × IP factor 2; recovery below trace 10⁻⁶Data availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
IntegrationEuler; Δt = 0.1 msState reset between exposuresData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Table 14. Connection probabilities, conductances and learning rules in the simulated PN–KC–APL–MBON network. Fixed connections are distinguished from the plastic readout and training-only teacher input; these values are simulation settings.
ConnectionWeight / totalLearningSource / selection basis
PN→KCp = 0.05; incoming sum 800 nS / KCFixed random projectionData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
KC→APL30 nS per synapseFixed; all KCsData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
APL→KC30 nS per synapseFixed; all KCsData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
KC→MBONOutgoing sum 10 nS / KC; individual 0–10 nSPair potentiation ≤0.025 nS; τ = 5 ms; normalize after exposureData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Teacher→MBON1,500 nSOne-to-one; training onlyData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
MBON→teacher200 nS inhibitoryOne-to-one feedbackData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Different MBONs2,000 nS inhibitoryFixed mutual inhibitionData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Table 15. Input currents, exposure timing and sampled presentation counts for KT decoder training and testing. Learning is frozen during testing; sampled presentations are simulation trials, not additional independent sensor measurements.
SettingKT valueSource / selection basis
Odor current2.05 nA in eight active PNs for 30 msData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Teacher current10 nA in the correct teacher, beginning 1 ms after odor onsetData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Exposure / gap30 ms / 3 msData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Training300 cycles × five gases = 1,500 sampled presentationsData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Testing50 sampled presentations / gas = 250; learning frozenData availability; simulation setting. No AeroSense measurement fit or row-specific literature derivation is archived.
Sensitivity and biological transfer

Transfer to the biological reader

Gas delivery, receptor response, reporter dynamics, optical background and preprocessing form distinct transformations between airborne odor and decoder input. Metal-oxide benchmark scores therefore do not measure the cell-based reader. Transfer requires matched biological features and evaluation across device, day and collection conditions.

Table 16. Assumptions required to transfer the metal-oxide proxy studies to AeroSense biology. Each row identifies the corresponding delivery, fluorescence, receptor, drift or calibration quantity that still requires measurement.
DimensionMetal-oxide studyAeroSense quantity to identify
KineticsArchived peak-response features; dataset-specific samplingGas-to-cell delay, rise/decay, integration-window loss and sampling interval
Dynamic rangeResistance-derived feature scales and train-fitted binsΔF/F₀ distribution, reporter saturation and noise floor under fixed optical settings
SelectivityFive KT / six UCI gas labels; sensor-array response patternsReceptor × odor response matrix with dose, solvent, Orco and viability controls
DriftDevice/day/batch variation in resistance featuresCell-batch, expression, photobleaching, temperature and optical-registration variation
CalibrationReference-gas correction on UCI SVM featuresWhether a biological / optical reference predicts those changes without erasing true response
Reproduction record and analysis checks

Reproduction requirements

An independent decoder rerun requires the training engine, resolved presets, fitted preprocessing, fold and exposure IDs, seeds and machine-readable predictions. The available record describes the workflow but does not supply all these artifacts. Additional KT transfer observations lack enough metric, classifier and sample-budget detail for direct comparison with the SNN or UCI results.

Table 17. Available decoder documentation and the artifacts still required for an independent rerun. Reported equations and metrics do not replace executable code, resolved presets, fold assignments or prediction records.
RecordAvailableRequired for a rerun
DatasetCounts, cleaning and feature definitionsKT thesis citation, release authorization, exact features
PreprocessingTrain-only protocolFitted medians, scales, PCA and bins per fold
NetworkEquations, units, weights and scheduleExecutable code, versions and resolved presets
EvaluationSeventeen figures and reported metricsFold IDs, new-run seeds, exposure IDs and predictions
UncertaintyFold means and reported spreadSpread definition, fold values and separate seed replication
DeploymentSource description of integer implementationEngine, numerical agreement and device benchmarks

Analysis checks

The state-precision result was withdrawn because quantization ran every 1 ms while integration ran every 0.1 ms; nine of ten steps retained float64 states. It is separate from the later five-fold results. Fold spread is not a defined confidence interval or independent seed replication. Parameter sensitivity does not isolate circuit motifs, and no benchmark here establishes measured classification by the cell-based reader.

Receptor data and prediction methods

Dataset and holdouts

The benchmark contains 2,640 published responses from 24 Drosophila receptors and 110 odorants, without missing responses or duplicate pair IDs. Docking excludes multicomponent ammonium hydroxide and uses 2,616 pairs; the prediction benchmark retains all 2,640. Holdouts distinguish unseen pairs, odorants, chemical groups, receptors and receptor groups. DoOR overlaps the training sources, so its comparison checks consistency rather than independent generalization.

Sources [1] [17] [10] [6] [7] [18] [9] [19]

Table 18. Five prepared holdout definitions and the generalization question each asks. A defined split is not evidence that every model was evaluated on that split.
SplitQuestion
Random-pairPredict a held-out combination within known receptor and odorant sets.
Odorant-coldPredict an odorant excluded from training.
Chemical-cluster-coldPredict an excluded cluster of chemically similar odorants.
Receptor-coldPredict a receptor excluded from training.
Receptor-cluster-coldPredict an excluded sequence-related receptor group.

Matched prediction comparisons

Six feature sets use the same response pairs, histogram-gradient-boosting settings and fixed folds. Ligand-only, sequence/ESM, pocket, docking/contact and multiple-pose features are compared within that controlled design. Held-out-receptor R² rises from 0.1125 for ligand features to 0.2325 with sequence features; the full model reaches 0.2356 without a reliable additional gain. Earlier estimators and docking-population comparisons are retained separately because they do not use identical analysis populations.

Sources [1] [10] [7] [8] [9] [20] [17] [14]

Table 19. Matched feature ablation using the same response pairs, fixed folds and histogram-gradient-boosting settings. R² is reported for unseen chemical clusters and unseen receptors; the small full-model gain over ligand-plus-sequence features does not establish an additional structural-feature benefit.
FeaturesChemical-cluster-cold R² (coefficient of determination; 1 is perfect, 0 matches the mean baseline, and negative values are worse)Receptor-cold R²
L0.13070.1125
LS0.38550.2325
LSP0.38400.2221
LSD0.37810.2131
LSPD0.38370.2154
LSPDM0.37790.2356
Table 20. Historical model-development scores under different holdouts and representative model versions. R² and Spearman rank correlation are separate metrics; these rows must not be combined into the performance of one model.
Evaluation / modelR²Spearman ρ (rank correlation, from −1 to +1; it measures ordering, not prediction accuracy as a percentage)
Random-pair / stacked tree0.5690.739
Chemical-cluster-cold / global blend0.4200.659
Receptor-cold / original HGB0.2290.463
Receptor-cold / HGB with multiple poses0.2460.472

Feature-comparison cohorts

Measured IR uses 82 odorants, published harmonic modes use 85, the matched measured/computed intersection uses 67, and frozen OpenPOM features use 109. Comparisons retain their own matched baselines and fixed predictions. Bootstrap intervals describe conditional group-level uncertainty; different cohorts cannot be pooled into one feature ranking. Matched cohort definitions appear in the table below.

Sources [10] [14] [1] [9] [11] [6] [4] [5]

Table 21. Eligible odorants, receptor–odorant pairs and chemical groups for each molecular-feature experiment. Each cohort receives its own retrained baseline, so scores from different rows are not directly interchangeable.
ExperimentOdorantsResponse pairsChemical groups
Measured IR / size ablation821,96853
Quantum modes852,04056
Measured–computed overlap671,60845
OpenPOM (Principal Odor Map; OpenPOM is its open-source reproduction for learned molecular odor features) ([4]; [5])1092,61669

Measured spectra

Accepted gas-phase NIST spectra are aligned to a common representation and compared with molecular-weight and physicochemical controls on the same 82-odorant cohort. Adding measured IR did not improve held-out chemical-group prediction in either tested model family. The record includes the spectrum-quality criteria, example spectra and matched ablation values. This tests predictive information, not a molecular vibration-sensing mechanism.

Sources [21] [22] [2]

Published measurements

Measured odorant spectra

Figure 26. Six accepted NIST (US National Institute of Standards and Technology; its Chemistry WebBook supplies spectral records) gas-phase spectra after background correction and area normalization. Peak patterns describe relative molecular absorption, not receptor activity or absolute absorption strength. ([2])
Table 22. Matched R² results for measured infrared features, descriptor removals and random-feature controls on 82 odorants. Chemical and receptor columns denote separate holdouts; the comparison tests predictive value, not a biological vibration mechanism.
InputsChemical · HGBChemical · ExtraTreesReceptor · HGBReceptor · ExtraTrees
Baseline0.39300.37460.20800.1000
+ IR 630.32780.34580.21080.1103
Sequence + IR only0.21350.32090.16790.1103
Remove weight0.40520.35570.17920.1096
Remove size group0.36380.29950.20530.0949
+ Random 630.31940.32410.21320.1078

Harmonic-mode features

Published Gaussian calculations supply complete harmonic modes for 85 odorants. Equal-mode EVA and intensity-weighted computed IR encode the same modes differently; full and compressed features are compared with matched baselines. The 67-odorant overlap controls cohort membership when comparing measured and computed spectra, but still differs in spectral range, dimensionality and normalization. These comparisons do not isolate source accuracy or demonstrate vibrational detection.

Sources [3] [11] [23] [14] [24] [25] [26]

Our computational results

Equal-mode EVA versus intensity-weighted IR

Figure 27. Descriptors computed from two published harmonic mode sets, with the same Gaussian width and grid. The ordinate scales differ because EVA (a fixed-length descriptor formed by smoothing equally weighted normal-mode frequencies) weights modes equally and computed IR (infrared absorption: how a molecule absorbs light at different vibrational frequencies) uses intensities. Shading marks frequencies below the measured-IR window. This is not a measured spectrum or a receptor-bound calculation. ([11]; [3])
Table 23. R² comparison on 85 odorants for full 800-dimensional EVA or computed-IR features, 16-component training-fold PCA and random-feature controls. Point changes do not establish a stable improvement across models and holdouts.
InputsChemical · HGBChemical · ExtraTreesReceptor · HGBReceptor · ExtraTrees
Baseline0.38100.42250.22170.1435
+EVA 8000.34210.37720.23150.1175
+ Computed IR 8000.31770.37550.23720.1014
+EVA PCA 160.36830.41860.21860.1320
+ Computed IR PCA 160.36350.41640.22980.1272
+ Random 8000.22650.28120.23380.1037
+ Random 160.32410.39870.23230.1287
Table 24. R² comparison after retraining on the same 67-odorant, 1,608-pair measured/computed-spectrum overlap. Differences in spectral range, dimension and normalization remain, so the comparison does not isolate source accuracy.
InputsChemical · HGBChemical · ExtraTreesReceptor · HGBReceptor · ExtraTrees
Baseline0.37440.40030.20750.1094
+EVA 8000.28470.34880.20760.0910
+ Computed IR 8000.23910.36430.20470.0968
+ Measured IR 630.33600.38090.21270.1121

Frozen molecular representations

OpenPOM contributes fixed 256-dimensional molecular features while retaining molecular weight. The 109-odorant comparison evaluates the same eligible responses with matched models and chemical-group holdouts. Performance changes depend on the model, and uncertainty intervals do not establish a consistent gain beyond the retained baseline. No task-specific adaptation is claimed; all out-of-fold predictions and paired comparisons remain in the record.

Sources [4] [5] [1] [27]

Table 25. R² results for frozen 256-dimensional OpenPOM features on 109 odorants, including fingerprint replacement, feature addition, random controls and a second fixed checkpoint. Effects depend on the response model; downstream holdout does not guarantee unseen molecules in upstream pretraining.
InputsChemical · HGBChemical · ExtraTreesReceptor · HGBReceptor · ExtraTrees
Baseline0.38920.35720.21080.1210
POM replaces fingerprint0.32510.40040.22670.1320
+ POM0.32320.39670.23320.1321
+ Random 2560.28210.27270.23120.1323
Replace: second weights0.35150.40750.20570.1256
Add: second weights0.35650.41030.21850.1351
Our computational results

Predicted versus measured response

Figure 28. Out-of-fold predictions for the chemical-group holdout, baseline versus added POM (Principal Odor Map; OpenPOM is its open-source reproduction for learned molecular odor features) ([4]; [5]). Each point is a receptor–odorant pair; shared receptors and chemicals mean points are not independent experimental replicates. The dashed line denotes perfect prediction. ([1])

Species-transfer evaluation

The fly-trained response predictor and local sequence-fragment matching answer different questions. The main fragment analysis compares 48 mosquito × 24 fly receptors using response profiles for 40 shared odorants, with receptor-level bootstrap and multiplicity adjustment. The leading 31-residue reciprocal method gives Spearman ρ = 0.141 and adjusted q = 0.259. Method selection used this same matrix, so it remains exploratory rather than an independent transfer validation.

Sources [12] [9] [13] [28] [29]

Structure preparation and trajectory checks

Structural references

8V00 and 8V02 are experimental cryo-EM structures of an OR10–Orco complex: Aedes aegypti OR10 with three Apocrypta bakeri Orco subunits. 8V00 is odorant-free; 8V02 contains o-cresol. They are structural references for molecular analysis, not functional measurements of the target Drosophila mutants. A resolved bound pose does not reveal the ligand’s entry route.

Sources [30] [6] [7] [14] [10]

Table 26. Experimental cryo-EM references used for the OR10–Orco studies: odorant-free 8V00 and o-cresol-bound 8V02. Both combine Aedes aegypti OR10 with Apocrypta bakeri Orco; they are structural references rather than target Drosophila receptor measurements.
PDB entryWhat was observedUse in our study
8V00Apo: no bound odorant. Experimental resolution: 2.88 Å (1 Å = 0.1 nm).Odorant-free structural reference; a starting template for apo MD and static docking comparisons.
8V02Odorant-bound (holo): o-cresol (2-methylphenol) is resolved in the OR10 pocket. Experimental resolution: 2.90 Å.Reference for the bound ligand pose, bound-state MD, and candidate outward-path studies.

Molecular-system preparation

Unresolved regions were rebuilt as structural hypotheses before embedding the complex in POPC, water and ions. OpenMM uses ff14SB/Lipid17, TIP3P water and GAFF ligand parameters with AM1-BCC charges. The baseline is 300 K and 1 bar with a 1 nm short-range cutoff; steering uses the documented NVT setup. The long Orco 244–312 loop has low template confidence (mean pLDDT 37.68; loop-to-core PAE 28.88 Å). Rebuilding completes coordinates without validating the native loop conformation.

Sources [6] [7] [14] [8] [31] [32] [33] [34] [35] [36]

Our computational results

Uncertainty in rebuilt Orco regions

Figure 29. AlphaFold (AI system that predicts protein 3D structures from sequence) confidence summaries for the three missing Orco (odorant-receptor co-receptor, a shared partner that forms the channel with the odor-selective OR) segments in 8V02 (PDB ID for the experimentally determined o-cresol-bound OR10–Orco complex). Higher pLDDT (predicted local structure confidence on a 0–100 scale; higher is more confident) indicates greater local confidence; larger loop-to-core PAE (predicted aligned error, an estimate of uncertainty in relative residue placement; lower is more confident) indicates less certain relative placement. The long 244–312 loop has particularly uncertain placement. Confidence is inherited from the template prediction and does not validate the subsequently rebuilt, relaxed coordinates. Structure / method references: ([6]; [7]).
Table 27. Unresolved Orco sequence segments in the experimental 8V02 and 8V00 references, with the total residues rebuilt across each complex. Rebuilt coordinates are starting hypotheses rather than experimentally resolved loop conformations.
ReferenceUnresolved Orco segments per subunitRebuilt residues across the complex
8V021–6, 160–167, 244–312249
8V001–3, 160–167, 244–312240

Trajectory diagnostics

Bound-state trajectories compare prespecified 3–5 ns and 15–20 ns windows. Geometry checks pass, but rebuilt regions continue to drift: their mean RMSD changes from 1.0383 to 1.5917 nm across those windows. Ser133 hydrogen-bond geometry fraction changes from 0.9567 to 0.7613. These trajectory-level structural summaries do not establish equilibrium, affinity, residence time or activation; frames are correlated and share the starting-model assumptions.

Sources [6]

Table 28. Bound-state MD readouts in the prespecified 3–5 ns and 15–20 ns windows, summarized as mean ± SD across trajectory-level averages. Frames are correlated; continued rebuilt-region drift prevents these diagnostics from establishing equilibrium.
Readout3–5 ns · mean ± SD (standard deviation, describing spread among observations)15–20 ns · mean ± SD
Temperature (K)300.2847 ± 0.0416300.2873 ± 0.0363
Box volume (nm³)6464.2306 ± 0.55426463.5634 ± 0.5781
Lateral area (nm²)384.2783 ± 0.5193378.9845 ± 1.8196
Membrane phosphate thickness (nm)3.8239 ± 0.00943.8575 ± 0.0128
Resolved-core Cα (alpha-carbon atoms, used to trace the protein backbone) RMSD (nm)0.2189 ± 0.00510.2500 ± 0.0212
OR10 (odorant receptor 10 from Aedes aegypti, the yellow-fever mosquito) ([6]) Cα RMSD (nm)0.1269 ± 0.01490.1432 ± 0.0180
Rebuilt-region Cα RMSD (nm)1.0383 ± 0.04451.5917 ± 0.1706
Ligand (a molecule that can bind to a receptor; here, the tested odorant) RMSD after OR10 fit (nm)0.0758 ± 0.00390.1142 ± 0.0434
Ser133 (serine at residue 133) H-bond geometry fraction0.9567 ± 0.02520.7613 ± 0.1792
Mutation and molecular-pathway methods

Mutation-score controls

Mutation comparisons retain the wild-type and mutant computational constructs, selected target/control odor panel, common docking box and pose-contact checks. F34Y and E196Q are distant from the ligand in the saved top poses; I87V shows that contact alone does not establish improved panel preference. Docking rankings depend on setup and are not measurements of binding affinity, biological sensitivity or receptor selectivity. The matched docking comparisons appear in the tables below.

Sources [10] [6] [1] [8] [7] [37]

Table 29. Or22a and Or35a substitutions included in the first computational structural screen. These are modeled constructs; similar predicted structures do not establish expression, stability or receptor function.
ReceptorSubstitutions in the first structural screen
Or22aE196Q, E196A (residue 196: glutamate → alanine), E196K (residue 196: glutamate → lysine), S33A (residue 33: serine → alanine), S33T (residue 33: serine → threonine), F34A (residue 34: phenylalanine → alanine), F34Y
Or35aI87A (residue 87: isoleucine → alanine), I87V (residue 87: isoleucine → valine), I87F (residue 87: isoleucine → phenylalanine), W305F (residue 305: tryptophan → phenylalanine), W305Y (residue 305: tryptophan → tyrosine)
Table 30. The selected eight mold-related and eight control odorants used in the docking panel-preference calculation. Preference refers to this score comparison and panel, not demonstrated mold specificity or receptor activation.
GroupOdorants
Mold-related1-octen-3-ol; 2-heptanone; 1-octanol; 1-butanol; 3-methylbutanol; 4-ethyl guaiacol; methyl octanoate; ethyl octanoate
Controlsacetophenone; benzaldehyde; ethyl acetate; ethyl butyrate; geranyl acetate; linalool; linalool oxide; methyl acetate

Ensembles and functional panels

Static and MD-ensemble docking are compared against published responses, with the seven-odorant oocyte panel kept separate from the expanded 29-odorant assay. The initial panel has nine oocytes per odorant and uses 3-methylindole normalization; o-cresol supplies a pose control but has no functional label in that panel. Its native pose is reproduced at 1.17–1.22 Å symmetry-corrected heavy-atom RMSD. Retrospective rank correlations and short trajectories do not establish prospective generalization or equilibrium.

Sources [14] [10] [6] [15] [30] [20] [38]

Experimental structure

Where is the odorant in the receptor complex?

Figure 30. Cα (alpha-carbon atoms, used to trace the protein backbone) traces and o-cresol (2-methylphenol, the odorant resolved in 8V02) heavy atoms from experimental PDB (Protein Data Bank, the archive of molecular 3D structures) ([30]) 8V02 (PDB ID for the experimentally determined o-cresol-bound OR10–Orco complex). Teal is OR10 (odorant receptor 10 from Aedes aegypti, the yellow-fever mosquito), gray-green the three Orco (odorant-receptor co-receptor, a shared partner that forms the channel with the odor-selective OR) subunits, and orange the odorant. Missing resolved-chain segments remain disconnected. The tan band is a homology-transferred membrane-orientation reference, not observed lipids. This figure shows the structural starting reference, not an MD (molecular dynamics: computing atomic motion step by step from a force field) ([14]) trajectory. Experimental structure source: ([6]).
Our computational results

See the odorants behind the correlation

Figure 31. Each panel contains the same 29 odorants. Our docking (computationally placing and scoring ligand poses in a receptor) ([10]) scores are compared with AaOR10 (odorant receptor 10 from Aedes aegypti, the yellow-fever mosquito) ([6]) calcium responses digitized from Bohbot et al. (2011), Figure 2; these are literature measurements, not our wet-lab results. The horizontal axis reverses the Vina (AutoDock Vina docking score; lower scores are more favorable in this model, not a measured response) ([20]) score so stronger predicted docking lies to the right. Color identifies aromatic chemistry. The scatter exposes substantial response variation at similar scores; ensemble docking has not established a calibrated sensitivity or EC50 (concentration producing half the maximal response in a specified functional assay) predictor. Published data source: ([15]).
Our computational results

The first functional panel and static docking controls

Figure 32. Top: published AaegOR10 (odorant receptor 10 from Aedes aegypti, the yellow-fever mosquito) ([6])/AaegOrco (the odorant-receptor co-receptor from Aedes aegypti) oocyte currents normalized to 3-methylindole, with mean ± SEM (standard error of the mean, describing uncertainty in an estimated mean) from nine oocytes per odorant. A zero SEM for the normalization reference is not evidence of noise-free measurement. Bottom: this project’s static docking (computationally placing and scoring ligand poses in a receptor) ([10]) scores versus the same seven response means. The assay (a defined experimental test of biological activity) uses a different Orco (odorant-receptor co-receptor, a shared partner that forms the channel with the odor-selective OR) from the structural complex, and screening concentration remains unresolved. This panel is analyzed separately from the 29-odorant calcium assay. Published data source: ([38]).

Entry criteria

External-water, membrane-interface and near-entrance placements reduce different encounter barriers. Analysis tracks distance, designated pocket contacts and sustained occupancy for the same molecule. Surface or membrane encounters are not counted as entry. Near-entrance runs extending to 10 ns showed no sustained pocket entry; this time window cannot rule out slower entry or other routes.

Sources [6]

Steering and exit criteria

Direct ligand pulling and receptor-distance guidance are separate protocols. Receptor guidance controls nine S3/S6 distances without pulling o-cresol directly; short, extended and 70 ns schedules retain matched controls. A candidate exit requires distance ≥1.5 nm from the pocket reference, zero designated pocket contacts and persistence ≥100 ps within one stage. Neither guided nor unsteered 70 ns trajectories met that criterion. Entrance-distance changes and non-equilibrium work do not measure a natural exit rate or free-energy barrier.

Sources [6] [16]

Method schematic

Two different targets for an applied force

Figure 33. Left: SMD (steered molecular dynamics: MD with an applied guiding force) ([16]) couples the odorant to a moving target using a spring. Right: a separate protocol guides S3/S6 (labels for the third and sixth membrane-spanning helices of OR10) ([6]) reference distances while applying no direct pulling force to the odorant. Blue arrows indicate imposed guidance, not observed trajectories. Both protocols test constrained conditions and do not measure natural entry or exit rates.
Table 31. Durations of baseline, receptor-distance guidance, target holding and bias removal in the three guided protocols. These schedules control receptor distances rather than pulling the ligand directly.
StageShort protocolExtended protocol70 ns (nanoseconds, 10⁻⁹ seconds) protocol
Baseline0.1 ns0.1 ns0.1 ns
Change the target1 ns5 ns5 ns
Hold the target0.5 ns2.5 ns63.9 ns
After bias removal1 ns1 ns1 ns
Total trajectory time2.6 ns8.6 ns70 ns
Our computational results

Short versus extended entrance guidance

Figure 34. Entrance-distance RMSE (root-mean-square error relative to the selected reference values) over the last 100 ps (picoseconds, 10⁻¹² seconds) before bias removal, compared with time-matched unsteered controls. Each starting conformation is shown separately. The extended protocol changes both target-ramp duration and holding time. Lower RMSE means closer to the selected apo (the odorant-free state) distances, not a wider or passable tunnel. The comparison is descriptive and uses correlated trajectories.

Whole-ligand pathway tests

Rigid searches include all 16 o-cresol atoms, translation and rotation, two candidate corridors, and protein-only versus protein-plus-lipid obstacles. Twenty-four saved conformations did not supply a complete low-clash route. Flexible pulling advances at 0.2 or 0.5 nm/ns and pauses at 0.40 nm lag or 180 kJ/mol/nm force; resumption requires lag below 0.20 nm and force below 100 kJ/mol/nm. Extending fixed-target waiting to 2 ns did not establish sustained exit. Positive Lennard–Jones repulsion diagnoses clashes, not free-energy barriers, and paths from different snapshots cannot be joined into an observed trajectory.

Sources [6] [16] [14]

Table 32. Centerline lengths and peak positive-repulsion scores for two whole-ligand corridors in the fixed 63.2 ns snapshot. Protein-only and protein-plus-lipid scores diagnose clashes; they are not free-energy barriers or observed ligand passage.
CorridorCenterline arc (nm)Protein peak (kJ/mol)Protein + lipid peak (kJ/mol)
Lower membrane coordinate3.2712,005555,394
S3/S6 lateral4.0329,838103,961
Our computational results

Locate the obstruction along a candidate path

Figure 35. Detailed static placement scan for the 69 ns (nanoseconds, 10⁻⁹ seconds) entrance-guided A snapshot: the lower corridor has the lowest combined repulsion peak among the evaluated selected paths. Top panels score the same ligand (a molecule that can bind to a receptor; here, the tested odorant) poses with protein alone and with protein plus lipids; the dotted line is the native-pose reference (~23 kJ/mol). Bottom panels identify the four largest contributors at two different peaks of the lower route: protein at 1.54 nm (nanometers; 1 nm = 10⁻⁹ meters) and combined at 2.97 nm. Protein residues and later lipids both obstruct this candidate. Distances are path arc lengths, not simulation time; positive LJ (an atomic interaction potential; only its positive repulsive part is summed in our clash scans) repulsion is a clash diagnostic, not a free-energy profile.

Molecular availability

Matched starting boxes compare one and twenty o-cresol molecules, approximately 0.26 and 5.2 mM by whole-box volume. These are not water-phase concentrations or airborne ppm. Completed 2 ns runs form an incomplete, unbalanced comparison: mean per-molecule protein-contact fractions are 0/0.036 for model A and 0/0.021 for model B. Shared molecules are not independent experiments; surface contact does not establish a concentration–response curve or association rate.

Sources [6]

Table 33. Mean per-molecule protein-contact time fractions for completed, checked 2 ns trajectories with one or twenty o-cresol molecules in starting models A and B. This incomplete exploratory comparison measures surface contact, not sustained pocket entry, a concentration–response curve or an association rate.
Starting model1 odorant20 odorants
A0.0000.036
B0.0000.021
Evidence record and comparison design

Evidence and provenance

Stored out-of-fold predictions support model comparisons; pose-level outputs support docking and pathway checks. Provenance manifests retain source hashes and analysis coverage. Trajectory export differs by study: water and lipid-tail coordinates were not continuously saved in every case. Candidate prioritization, structural diagnostics and comparison designs are supported; improved mutant function, complete molecular passage and transfer to independent assays require their own evidence.

Sources [14] [4] [5] [6] [10]

Table 34. Inference boundaries for prediction, mutation, starting structures and molecular pathways, paired with the comparisons defined to address them.
Defined comparisonQuestion it can answer
Fold-contained AI adaptation, 3D odorant descriptors and independent dataCan richer features improve responses beyond the retained baseline?
Alternative loop hypotheses and local drift analysisHow dependent are the conclusions on uncertain starting regions?
Target Drosophila WT (wild type: the unmutated reference sequence)/mutant OR–Orco (odorant-receptor co-receptor, a shared partner that forms the channel with the odor-selective OR) ([6]) complexesDo candidate-specific dynamic differences reproduce?
Independent functional data and nested species-transfer evaluationDoes performance persist on genuinely unseen receptors and assays (a defined experimental test of biological activity)?
Matched expression and functional dose-response experimentsDo designed receptors change activity, selectivity or sensitivity?
Continuous flexible pathways and unbiased follow-upIs a guided route physically sustainable after removing the force?

Matched comparison design

The defined comparison pairs small ligand-guidance steps and local relaxation with a no-pull control. Readouts track ligand, side-chain, lipid and water motion, collision diagnostics and persistence after force removal. Matched expression and receptor dose–response measurements are the separate functional endpoint. This is a comparison design, not a completed experiment.

Sources [27]

Comparison design

Coordinated motion with a matched control

Figure 36. The comparison design pairs small guided ligand movements and local relaxation with a matched no-pull condition. It records side-chain, lipid and water rearrangements relative to ligand motion. This schematic specifies the comparison; it contains no experimental result.

References

Research papers

Hardware simulation sources

  1. Firpo, G., Angeli, E., Guida, P., Pezzuoli, D., Repetto, D., Repetto, L., & Valbusa, U. (2019). The Role of Surfaces in Gas Transport Through Polymer Membranes. Polymers, 11(5), 910. Source ↗
    Source highlights

    Measures PDMS gas transport and distinguishes bulk diffusion from surface resistance. Table 1 supplies the source package’s oxygen example at 293 K; it does not supply the generic VOC grid or characterize the proposed film.

  2. Burton, A., Obaid, S. N., Vázquez-Guardado, A., Schmit, M. B., Stuart, T., Cai, L., Chen, Z., Kandela, I., Haney, C. R., Waters, E. A., Cai, H., Rogers, J. A., Lu, L., & Gutruf, P. (2020). Wireless, battery-free subdermally implantable photometry systems for chronic recording of neural dynamics. Proceedings of the National Academy of Sciences, 117(6), 2835–2845. Source ↗
    Source highlights

    Figure 2H–J separates excitation fluence, detector acceptance and their overlap. It supports the optical-map method and excitation-rejection rationale; its implant geometry, filter and measured performance are not AeroSense inputs.

  3. Wang, L., Jacques, S. L., & Zheng, L. (1995). MCML—Monte Carlo modeling of light transport in multi-layered tissues. Computer Methods and Programs in Biomedicine, 47(2), 131–146. Source ↗
    Source highlights

    Primary description of weighted-photon Monte Carlo transport through absorbing and scattering media with refractive interfaces. AeroSense uses these transport ingredients in independent code, not the MCML program or its tissue parameters.

  4. LEE Filters. 101 Yellow. Accessed 11 October 2026. Source ↗
    Source highlights

    Manufacturer transmission information for the sampled LEE101 curve. Layer stacking, source spectra and complete-reader performance are separate modeling assumptions.

  5. Edmund Optics. 500 nm, 12.5 mm Ultra-Thin OD4 Longpass Filter (#29-190). Accessed 11 October 2026. Source ↗
    Source highlights

    Manufacturer band specifications and dimensions: 12.45 ± 0.15 mm diameter, 0.30 mm thickness and 90% clear aperture. The wiki pointwise transmission is an explicit constructed scenario; the product page does not establish fit in AeroSense or measured device sensitivity.

  6. Qian, Y. H., d’Humières, D., & Lallemand, P. (1992). Lattice BGK Models for Navier-Stokes Equation. Europhysics Letters, 17(6), 479–484. Source ↗
    Source highlights

    Foundational lattice-BGK collision and equilibrium formulation used by the D3Q19 airflow solver. It supports the numerical method, not the chosen geometry, pump flow or biological safety limits.

  7. Guo, Z.-L., Zheng, C.-G., & Shi, B.-C. (2002). Non-equilibrium extrapolation method for velocity and pressure boundary conditions in the lattice Boltzmann method. Chinese Physics, 11(4), 366–374. Source ↗
    Source highlights

    Boundary distributions combine imposed equilibrium values with an extrapolated non-equilibrium part from a neighboring fluid node. This matches the pressure-terminal reconstruction in the airflow source code; it is not a citation for the separate scalar solver.

  8. Bian, P., Wang, Y., & McCarthy, T. J. (2021). Rediscovering Silicones: The Anomalous Water Permeability of “Hydrophobic” PDMS Suggests Nanostructure and Applications in Water Purification and Anti-Icing. Macromolecular Rapid Communications, 42(5), 2000682. Source ↗
    Source highlights

    Experiments on unfilled, silica-free PDMS show that water repellency does not imply low water-vapor transmission; thin-film surface kinetics can matter. No evaporation rate or culture lifetime is transferred to AeroSense.

Odor decoding sources

  1. Marco, S., & Gutiérrez-Gálvez, A. (2012). Signal and data processing for machine olfaction and chemical sensing: A review. IEEE Sensors Journal, 12(11), 3189–3214. Source ↗
    Source highlights
    • Reviews signal and data processing for machine olfaction / electronic noses.
    • Background for conventional e-nose pipelines that AeroSense compares against conceptually.
  2. Vergara, A., Vembu, S., Ayhan, T., Ryan, M. A., Homer, M. L., & Huerta, R. (2012). Chemical gas sensor drift compensation using classifier ensembles. Sensors and Actuators B: Chemical, 166–167, 320–329. Source ↗
    Source highlights
    • Public chemical gas sensor drift dataset used widely in e-nose machine learning.
    • Dataset context for drift-robust classification benchmarks (not AeroSense wet-lab data).
  3. AeroSense modeling team. (2026). AeroSense — Model (iGEM Wiki V3). Team-supplied analysis record. Source ↗
  4. Turner, G. C., Bazhenov, M., & Laurent, G. (2008). Olfactory representations by Drosophila mushroom body neurons. Journal of Neurophysiology, 99(2), 734–746. Source ↗
    Source highlights
    • Olfactory representations and coding ideas that motivate sparse / combinatorial models.
    • Biological inspiration only — not an AeroSense measurement.
  5. Caron, S. J. C., Ruta, V., Abbott, L. F., & Axel, R. (2013). Random convergence of olfactory inputs in the Drosophila mushroom body. Nature, 497, 113–117. Source ↗
    Source highlights
    • Random convergence of olfactory inputs onto Kenyon cells in the Drosophila mushroom body.
    • Biological inspiration for sparse high-dimensional odor representations (computational analogy only).
  6. Lin, A. C., Bygrave, A. M., de Calignon, A., Lee, T., & Miesenböck, G. (2014). Sparse, decorrelated odor coding in the mushroom body enhances learned odor discrimination. Nature Neuroscience, 17(4), 559–568. Source ↗
    Source highlights
    • Mushroom-body circuit organization relevant to sparse odor coding analogies.
    • Supports fly-inspired computational framing on the Model page.
  7. Aso, Y., et al. (2014). Mushroom body output neurons encode valence and guide memory-based action selection in Drosophila. eLife, 3, e04580. Source ↗
    Source highlights
    • Comprehensive mushroom-body output neuron map in Drosophila.
    • Anatomical inspiration for MBON-style readout stages in the computational analogy.
  8. Dasgupta, S., Stevens, C. F., & Navlakha, S. (2017). A neural algorithm for a fundamental computing problem. Science, 358(6364), 793–796. DOI: 10.1126/science.aam9868.
    Source highlights
    • Connects fly mushroom-body sparse coding ideas to locality-sensitive hashing for similarity search.
    • Provides a computational rationale for sparse, efficient odor-pattern representations.
  9. Schmuker, M., & Schneider, G. (2007). Processing and classification of chemical data inspired by insect olfaction. Proceedings of the National Academy of Sciences, 104(51), 20285–20289. Source ↗
    Source highlights
    • Early computational olfaction / classification work used as baseline inspiration.
    • Historical context for sparse or biologically motivated odor classifiers.
  10. Imam, N., & Cleland, T. A. (2020). Rapid online learning and robust recall in a neuromorphic olfactory circuit. Nature Machine Intelligence, 2, 181–191. Source ↗
    Source highlights
    • Neuromorphic / olfactory-computation framing for rapid odor identification.
    • Supports discussing biologically inspired algorithms versus conventional ML baselines.
  11. Babadi, B., & Sompolinsky, H. (2014). Sparseness and expansion in sensory representations. Neuron, 83(5), 1213–1226. Source ↗
    Source highlights

    Expansion and sparseness can amplify within-class variability; they do not guarantee robustness.

  12. Litwin-Kumar, A., Harris, K. D., Axel, R., Sompolinsky, H., & Abbott, L. F. (2017). Optimal Degrees of Synaptic Connectivity. Neuron, 93(5), 1153–1164.e7. Source ↗
    Source highlights

    Relates synaptic degree, representation dimension and associative readout performance.

  13. Aso, Y., & Rubin, G. M. (2016). Dopaminergic neurons write and update memories with cell-type-specific rules. eLife, 5, e16135. Source ↗
    Source highlights

    Dopaminergic cell types modify memories under distinct timing-dependent rules.

  14. Jiang, L., & Litwin-Kumar, A. (2021). Models of heterogeneous dopamine signaling in an insect learning and memory center. PLOS Computational Biology, 17(8), e1009205. Source ↗
    Source highlights

    Models heterogeneous dopamine signals, rather than one shared scalar error.

  15. Cassenaer, S., & Laurent, G. (2012). Conditional modulation of spike-timing-dependent plasticity for olfactory learning. Nature, 482, 47–52. Source ↗
    Source highlights

    Locust experiments connect timing-dependent plasticity and neuromodulation; biological context, not direct validation of this fly-inspired model.

  16. Zhang, L., & Zhang, D. (2015). Domain Adaptation Extreme Learning Machines for Drift Compensation in E-nose Systems. IEEE Transactions on Instrumentation and Measurement, 64(7), 1790–1801. Source ↗
    Source highlights

    Uses limited labeled target-domain data, distinct from a zero-calibration claim.

  17. McCloskey, M., & Cohen, N. J. (1989). Catastrophic interference in connectionist networks: The sequential learning problem. Psychology of Learning and Motivation, 24, 109–165. Source ↗
    Source highlights

    Introduces the sequential-learning interference problem motivating retention tests.

  18. Rodríguez-Luján, I., Fonollosa, J., Vergara, A., Homer, M., & Huerta, R. (2014). On the calibration of sensor arrays for pattern recognition using the minimal number of experiments. Chemometrics and Intelligent Laboratory Systems, 130, 123–134. Source ↗
    Source highlights

    Examines calibration sampling and concentration coverage; a requested UCI source citation.

  19. Vergara, A. (2012). Gas Sensor Array Drift at Different Concentrations [Dataset]. UCI Machine Learning Repository. Source ↗
    Source highlights

    13,910 measurements, 16 sensors, six gases, 128 features, ten batches and concentration metadata across 36 months.

  20. Jolliffe, I. T. (2002). Principal Component Analysis (2nd ed.). Springer. Source ↗
    Source highlights
    • Standard reference on principal component analysis.
    • Used when discussing conventional dimensionality reduction baselines.
  21. Stimberg, M., Brette, R., & Goodman, D. F. M. (2019). Brian 2, an intuitive and efficient neural simulator. eLife, 8, e47314. DOI: 10.7554/eLife.47314.
    Source highlights
    • Brian 2 simulator for spiking neural networks.
    • Software context for the Dry Lab / Model Brian2 experiments.
  22. Song, S., Miller, K. D., & Abbott, L. F. (2000). Competitive Hebbian learning through spike-timing-dependent synaptic plasticity. Nature Neuroscience, 3(9), 919–926. Source ↗
    Source highlights
    • Spike-timing-dependent plasticity (STDP) classic reference.
    • Learning-rule context for spiking-network training discussions.
Other sources

Receptor engineering sources

Publications, datasets and software cited in the receptor-engineering analysis.

  1. Hallem, E. A., & Carlson, J. R. (2006). Coding of Odors by a Receptor Repertoire. Cell, 125(1), 143–160. Source ↗
  2. National Institute of Standards and Technology. (n.d.). NIST Chemistry WebBook, SRD 69: Infrared spectra and data guide [Database]. Source ↗
  3. Harada, Y., Maeda, S., Shen, J., Misonou, T., Hori, H., & Nakamura, S. (2025). Motional representation; the ability to predict odor characters using molecular vibrations [Preprint]. arXiv, 2509.16245. Source ↗
  4. Lee, B. K., Mayhew, E. J., Sanchez-Lengeling, B., Wei, J. N., Qian, W. W., Little, K. A., Andres, M., Nguyen, B. B., Moloy, T., Yasonik, J., Parker, J. K., Gerkin, R. C., Mainland, J. D., & Wiltschko, A. B. (2023). A principal odor map unifies diverse tasks in olfactory perception. Science, 381(6661), 999–1006. Source ↗
  5. Barsainyan, A. A., Kumar, R., Saha, P., & Schmuker, M. (2023). OpenPOM — Open Principal Odor Map [Software; revision 5434c4b7badebca8e7d180aa34d2f787402121ee]. Source ↗
  6. Zhao, J., Chen, A. Q., Ryu, J., & del Mármol, J. (2024). Structural basis of odor sensing by insect heteromeric odorant receptors. Science, 384(6703), 1460–1467. Source ↗
  7. Jumper, J., Evans, R., Pritzel, A., Green, T., Figurnov, M., Ronneberger, O., Tunyasuvunakool, K., Bates, R., Žídek, A., Potapenko, A., Bridgland, A., Meyer, C., Kohl, S. A. A., Ballard, A. J., Cowie, A., Romera-Paredes, B., Nikolov, S., Jain, R., Adler, J., Back, T., Petersen, S., Reiman, D., Clancy, E., Zielinski, M., Steinegger, M., Pacholska, M., Berghammer, T., Bodenstein, S., Silver, D., Vinyals, O., Senior, A. W., Kavukcuoglu, K., Kohli, P., & Hassabis, D. (2021). Highly accurate protein structure prediction with AlphaFold. Nature, 596(7873), 583–589. Source ↗
  8. Mirdita, M., Schütze, K., Moriwaki, Y., Heo, L., Ovchinnikov, S., & Steinegger, M. (2022). ColabFold: making protein folding accessible to all. Nature Methods, 19(6), 679–682. Source ↗
  9. Lin, Z., Akin, H., Rao, R., Hie, B., Zhu, Z., Lu, W., Smetanin, N., Verkuil, R., Kabeli, O., Shmueli, Y., dos Santos Costa, A., Fazel-Zarandi, M., Sercu, T., Candido, S., & Rives, A. (2023). Evolutionary-scale prediction of atomic-level protein structure with a language model. Science, 379(6637), 1123–1130. Source ↗
  10. Trott, O., & Olson, A. J. (2010). AutoDock Vina: Improving the speed and accuracy of docking with a new scoring function, efficient optimization, and multithreading. Journal of Computational Chemistry, 31(2), 455–461. Source ↗
  11. Turner, D. B., & Willett, P. (2000). The EVA spectral descriptor. European Journal of Medicinal Chemistry, 35(4), 367–375. Source ↗
  12. Carey, A. F., Wang, G., Su, C. Y., Zwiebel, L. J., & Carlson, J. R. (2010). Odorant reception in the malaria mosquito Anopheles gambiae. Nature, 464(7285), 66–71. Source ↗
  13. Benjamini, Y., & Hochberg, Y. (1995). Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing. Journal of the Royal Statistical Society Series B: Statistical Methodology, 57(1), 289–300. Source ↗
  14. Eastman, P., Galvelis, R., Peláez, R. P., Abreu, C. R. A., Farr, S. E., Gallicchio, E., Gorenko, A., Henry, M. M., Hu, F., Huang, J., Krämer, A., Michel, J., Mitchell, J. A., Pande, V. S., Rodrigues, J. P., Rodriguez-Guerra, J., Simmonett, A. C., Singh, S., Swails, J., Turner, P., Wang, Y., Zhang, I., Chodera, J. D., De Fabritiis, G., & Markland, T. E. (2024). OpenMM 8: Molecular Dynamics Simulation with Machine Learning Potentials. The Journal of Physical Chemistry B, 128(1), 109–116. Source ↗
  15. Bohbot, J. D., Jones, P. L., Wang, G., Pitts, R. J., Pask, G. M., & Zwiebel, L. J. (2011). Conservation of Indole Responsive Odorant Receptors in Mosquitoes Reveals an Ancient Olfactory Trait. Chemical Senses, 36(2), 149–160. Source ↗
  16. Isralewitz, B., Baudry, J., Gullingsrud, J., Kosztin, D., & Schulten, K. (2001). Steered molecular dynamics investigations of protein function. Journal of Molecular Graphics and Modelling, 19(1), 13–25. Source ↗
  17. Kim, S., Chen, J., Cheng, T., Gindulyte, A., He, J., He, S., Li, Q., Shoemaker, B. A., Thiessen, P. A., Yu, B., Zaslavsky, L., Zhang, J., & Bolton, E. E. (2025). PubChem 2025 update. Nucleic Acids Research, 53(D1), D1516–D1525. Source ↗
  18. Varadi, M., Anyango, S., Deshpande, M., Nair, S., Natassia, C., Yordanova, G., Yuan, D., Stroe, O., Wood, G., Laydon, A., Žídek, A., Green, T., Tunyasuvunakool, K., Petersen, S., Jumper, J., Clancy, E., Green, R., Vora, A., Lutfi, M., Figurnov, M., Cowie, A., Hobbs, N., Kohli, P., Kleywegt, G., Birney, E., Hassabis, D., & Velankar, S. (2022). AlphaFold Protein Structure Database: massively expanding the structural coverage of protein-sequence space with high-accuracy models. Nucleic Acids Research, 50(D1), D439–D444. Source ↗
  19. Münch, D., & Galizia, C. G. (2016). DoOR 2.0 - Comprehensive Mapping of Drosophila melanogaster Odorant Responses. Scientific Reports, 6, 21841. Source ↗
  20. Eberhardt, J., Santos-Martins, D., Tillack, A. F., & Forli, S. (2021). AutoDock Vina 1.2.0: New Docking Methods, Expanded Force Field, and Python Bindings. Journal of Chemical Information and Modeling, 61(8), 3891–3898. Source ↗
  21. Saberi, M., & Seyed-allaei, H. (2016). Odorant receptors of Drosophila are sensitive to the molecular volume of odorants. Scientific Reports, 6, 25103. Source ↗
  22. Chacko, R., Jain, D., Patwardhan, M., Puri, A., Karande, S., & Rai, B. (2020). Data based predictive models for odor perception. Scientific Reports, 10, 17136. Source ↗
  23. Gabler, S., Soelter, J., Hussain, T., Sachse, S., & Schmuker, M. (2013). Physicochemical vs. Vibrational Descriptors for Prediction of Odor Receptor Responses. Molecular Informatics, 32(9–10), 855–865. Source ↗
  24. Franco, M. I., Turin, L., Mershin, A., & Skoulakis, E. M. C. (2011). Molecular vibration-sensing component in Drosophila melanogaster olfaction. Proceedings of the National Academy of Sciences, 108(9), 3797–3802. Source ↗
  25. Block, E., et al. (2015). Implausibility of the vibrational theory of olfaction. Proceedings of the National Academy of Sciences, 112(21), E2766–E2774. Source ↗
  26. Williams, J. Z., Marszalek, P. E., & Yang, W. (2026). Evidence from computational infrared spectroscopy against vibrational detection of propionate by human olfactory receptor OR51E2. European Biophysics Journal, 55(4), 631–638. Source ↗
  27. McConachie, G., Duniec, E., Guerina, F., Younger, M., & DePasquale, B. (2026). Low rank adaptation of chemical foundation models generate effective odorant representations. International Conference on Learning Representations (ICLR 2026). Source ↗
  28. de Fouchier, A., Walker, W. B., Montagné, N., Steiner, C., Binyameen, M., Schlyter, F., Chertemps, T., Maria, A., François, M. C., Monsempes, C., Anderson, P., Hansson, B. S., Larsson, M. C., & Jacquin-Joly, E. (2017). Functional evolution of Lepidoptera olfactory receptors revealed by deorphanization of a moth repertoire. Nature Communications, 8, 15709. Source ↗
  29. Jacquin-Joly, E., Legeai, F., Montagné, N., Monsempes, C., François, M. C., Poulain, J., Gavory, F., Walker III, W. B., Hansson, B. S., & Larsson, M. C. (2012). Candidate chemosensory Genes in Female Antennae of the Noctuid Moth Spodoptera littoralis. International Journal of Biological Sciences, 8(7), 1036–1050. Source ↗
  30. Berman, H. M., Westbrook, J., Feng, Z., Gilliland, G., Bhat, T. N., Weissig, H., Shindyalov, I. N., & Bourne, P. E. (2000). The Protein Data Bank. Nucleic Acids Research, 28(1), 235–242. Source ↗
  31. Jorgensen, W. L., Chandrasekhar, J., Madura, J. D., Impey, R. W., & Klein, M. L. (1983). Comparison of simple potential functions for simulating liquid water. The Journal of Chemical Physics, 79(2), 926–935. Source ↗
  32. Maier, J. A., Martinez, C., Kasavajhala, K., Wickstrom, L., Hauser, K. E., & Simmerling, C. (2015). ff14SB: Improving the Accuracy of Protein Side Chain and Backbone Parameters from ff99SB. Journal of Chemical Theory and Computation, 11(8), 3696–3713. Source ↗
  33. OpenMM contributors. (n.d.). OpenMM User Guide 7.7: Running simulations, AMBER14 force fields [Software documentation; includes ff14SB and Lipid17 parameter-file descriptions]. Source ↗
  34. Wang, J., Wolf, R. M., Caldwell, J. W., Kollman, P. A., & Case, D. A. (2004). Development and testing of a general amber force field. Journal of Computational Chemistry, 25(9), 1157–1174. Source ↗
  35. Jakalian, A., Jack, D. B., & Bayly, C. I. (2002). Fast, efficient generation of high‐quality atomic charges. AM1‐BCC model: II. Parameterization and validation. Journal of Computational Chemistry, 23(16), 1623–1641. Source ↗
  36. Grossfield, A., Patrone, P. N., Roe, D. R., Schultz, A. J., Siderius, D., & Zuckerman, D. M. (2018). Best Practices for Quantification of Uncertainty and Sampling Quality in Molecular Simulations [Article v1.0]. Living Journal of Computational Molecular Science, 1(1), 5067. Source ↗
  37. Zhang, C., Shine, M., Pyle, A. M., & Zhang, Y. (2022). US-align: universal structure alignments of proteins, nucleic acids, and macromolecular complexes. Nature Methods, 19(9), 1109–1115. Source ↗
  38. Pullmann-Lindsley, H., Huff, R. M., Boyi, J., & Pitts, R. J. (2024). Odorant receptors for floral- and plant-derived volatiles in the yellow fever mosquito, Aedes aegypti (Diptera: Culicidae). PLOS ONE, 19(5), e0302496. Source ↗
On this page