ADC
Analog-to-digital converter — hardware that samples an analog voltage and encodes it as a digital value.
THE FIELD DICTIONARY
Clear definitions for the science, engineering and decisions behind AeroSense.
What does Orco mean?
Odorant receptor co-receptor — an insect co-receptor that partners with ORs to form ligand-gated ion channels.
Start with a term. Follow the connections.
127 definitions
Analog-to-digital converter — hardware that samples an analog voltage and encodes it as a digital value.
A family of mycotoxins produced by some Aspergillus fungi. Detecting an odor associated with a fungus does not measure toxin concentration.
Antennal lobe — the insect brain center that receives primary olfactory input and performs early odor processing.
Air–liquid interface — a culture or sampling setup where cells contact gas above a liquid medium.
A statistical score comparing variation between groups with variation within groups; used here as one feature-ranking check.
Business-to-business: a product or service sold to an organization rather than directly to individual consumers.
A simple comparison method used to judge whether a more complex model actually adds value.
The first narrowly defined customer group and use case a team chooses to test before expanding.
A standardized genetic part format used in iGEM and related registries for modular DNA assembly.
Bill of materials — the list of parts, quantities, and specifications needed to build a device.
A type IIS restriction enzyme used in some DNA assembly workflows; an internal site can interfere with that assembly method.
Biosafety level — a set of containment practices and facilities matched to the organisms and procedures in a laboratory.
Computer-aided design — the digital geometry and drawings used to describe and revise a physical part.
Comparing an instrument with a known reference so its response can be interpreted or corrected.
Coding sequence — the DNA segment whose information is translated into a protein.
Computational fluid dynamics — numerical calculations of fluid motion, used here to compare airflow and pressure through the reader.
A signal exceeding the usable measurement range and being cut off at a limit. Background subtraction cannot recover the missing signal.
A promoter derived from cytomegalovirus that is commonly used to drive gene expression in mammalian cells.
Changing a gene's DNA codons while preserving its protein sequence, often to suit the expression host.
A genetic construct assembled from multiple functional DNA elements to perform a defined role.
A follow-up test using an appropriate validated method to investigate a screening signal.
A table comparing predicted classes with reference labels, including correct and incorrect decisions.
Signal from one channel appearing in another. In the four-well reader, optical mixing can remain even after frequency-selective processing.
Evaluating a model across multiple training/test splits to estimate how it performs on unseen data.
Electrical output from a light-detection system even when no intended light reaches its sensor.
Information from the test set enters model training, making performance appear better than it would be on truly new data.
Design → Build → Test → Learn → Redesign: a cycle that records a decision, its test, what was learned, and the next change.
Direct digital synthesis — generating a periodic waveform using a digital phase accumulator and a reference clock.
The lowest signal or concentration that a specified method can reliably distinguish from its blank under stated conditions.
Digital lock-in amplifier — a digital method that extracts a signal at a known reference frequency while rejecting other noise.
Design-rule check — software checks whether a PCB layout follows specified spacing and manufacturing rules.
A genus of flies. The fruit fly Drosophila melanogaster is a source of well-studied odorant receptors and inspired the project's sensing and coding designs.
An instrument that combines chemical sensors and pattern analysis to distinguish odor mixtures.
Exponential moving average — a display smoothing method that gives more weight to recent values. Smoothing does not remove systematic measurement error.
An internal ribosome entry site derived from encephalomyocarditis virus, used to translate a downstream protein from the same mRNA.
Electrical-rule check — software checks for possible connection mistakes in a circuit schematic.
A family of microcontrollers that can control electronics and process data on a compact board.
Light used to stimulate a fluorescent reporter; it must be separated from the weaker light emitted by the reporter.
A classification score combining precision and recall. Its meaning depends on the dataset and evaluation split.
A test misses a problem that the reference condition says is present.
A test flags a problem when the reference condition says that problem is absent.
Frequency-division multiplexing — assigning distinct carrier frequencies so multiple optical channels can share a detector path.
Taiwan's From IP to IPO innovation and entrepreneurship program, which provided business-plan and pitch feedback to the team.
Light emitted by a molecule after it absorbs light at another wavelength. AeroSense uses a calcium-sensitive fluorescent reporter in its sensing design.
The ratio of emitted fluorescence photons to absorbed excitation photons. It describes emission efficiency, not how much light the detector collects.
An antibiotic used to select mammalian cells carrying a compatible resistance gene.
Gas chromatography–mass spectrometry — a laboratory method that separates volatile compounds and helps identify them by mass.
A family of genetically encoded fluorescent reporters that become brighter when calcium inside a cell rises.
A genetically encoded fluorescent calcium indicator used to report intracellular Ca²⁺ changes.
General-purpose input/output — programmable microcontroller pins that read or drive digital signals.
The gas above a liquid or solid sample; volatile molecules from the sample may enter this space.
A human cell line derived from embryonic kidney culture and transformed with adenovirus 5 DNA. HEK293 is the host used for the team’s heterologous receptor-expression experiments.
A large opposition to current flow. In a photodiode receiver, high-impedance input nodes require careful layout because small leakage currents can interfere with the measured signal.
Comparing a measured signal with two reference waves separated by a quarter cycle. Their in-phase and quadrature components describe the signal's amplitude and phase at a selected frequency.
The shared database where teams document biological parts, including their identity, sequence, and characterization.
A volatile organic compound that can occur in microbial metabolism; a signal of indole alone cannot identify a pathogen.
The way stakeholder input changes a project's choices throughout development, with the change and its evidence documented.
A compound that raises intracellular calcium and can test whether a calcium reporter responds independently of the odorant-receptor channel.
Institutional Review Board — a body that reviews certain research involving human participants; whether review is required depends on the activity and local rules.
Internal ribosome entry site — an RNA element that can initiate translation of a downstream open reading frame independently of the 5′ cap.
An international standard for the competence of testing and calibration laboratories. A future certification goal is not current accreditation.
Kenyon cell — a mushroom-body neuron that typically participates in sparse, high-dimensional odor representations.
Open-source software for designing circuit schematics and printed circuit boards.
A short sequence around a start codon that helps a mammalian ribosome begin protein translation.
A circuit motif in which active units suppress neighbors, often increasing contrast between signals.
Liquid chromatography–mass spectrometry — a laboratory method that separates compounds in a liquid sample and analyzes their masses.
Low-dropout regulator — a circuit that maintains a regulated supply voltage with a small required voltage difference between input and output.
Light-emitting diode — a semiconductor light source. In the reader, blue excitation light stimulates a fluorescent response; it is not the fluorescence signal itself.
A method for estimating environmental impacts across a product's materials, manufacture, use, and disposal.
Letter of intent — a written statement that an organization is interested in a defined next step; it is not the same as a purchase.
Leave-one-sensor-out analysis — remove one sensor at a time and see how a model's performance changes.
Locality-sensitive hashing — a method that maps similar inputs to nearby codes with high probability.
Mushroom body — an insect brain structure involved in olfactory learning, memory, and sparse odor coding.
Mushroom body output neuron — a neuron that reads mushroom-body activity and contributes to behavioral decisions.
A red fluorescent protein used here as an expression marker; it is distinct from the calcium-sensitive sensing readout.
Microcontroller unit — a small computer on a chip that coordinates electronics, timing, and data acquisition.
A numerical method that follows many randomly sampled events. In the optical model, simulated photon paths estimate how much light reaches the detector.
Minimum viable product — the smallest usable product that can test a specific customer need.
A toxic secondary metabolite that some fungi can produce. Detecting mold growth is not the same measurement as quantifying a mycotoxin.
A gene giving resistance to neomycin-family selection drugs such as G418, used to select cells carrying an expression vector.
Odorant-binding protein — a soluble protein that can bind and help transport hydrophobic odorants.
An insect receptor protein that helps turn binding by an odor molecule into a cellular signal, usually in partnership with Orco.
Light energy incident per unit area, integrated over time. In a steady optical calculation, the corresponding fluence rate describes light power per unit area arriving from all directions.
A fruit-fly odorant receptor considered in the project's receptor library for indole-related sensing research.
Odorant receptor co-receptor — an insect co-receptor that partners with ORs to form ligand-gated ion channels.
A coordinated set of biological parts with a clear purpose and documentation showing how the parts work together.
Principal component analysis — a method that summarizes variation in many measurements using a smaller set of combined axes.
Printed circuit board — the physical board that connects electronic components. A CAD layout is a board design, not proof that a board was manufactured.
A mammalian expression plasmid that carries inserted DNA and regulatory elements needed for expression in cultured cells.
Polydimethylsiloxane — a silicone polymer considered in transport models. It is not part of the current AeroSense assembly or required bill of materials.
An electronic component that converts incoming light into a small electrical current.
Photocurrent produced per unit of incident optical power, usually expressed in amperes per watt. It depends on the wavelength of the light.
A circular DNA molecule used as a carrier for genes or other genetic elements in an experiment.
Projection neuron — a neuron that relays processed olfactory information from the antennal lobe to higher centers.
Proof of concept — an early demonstration that a core idea can work under defined conditions.
A DNA signal that directs formation of the 3′ end and poly(A) tail of a messenger RNA in a eukaryotic cell.
An iGEM BioBrick assembly standard. Compatibility with it must be checked independently of other standards.
iGEM Registry assembly standard for composing BioBrick/RFC-compatible parts with defined prefix and suffix sites.
A classification of biological agents by the relative risk they pose; institutional assignment must be confirmed locally.
A category such as low, medium, or high used to guide the next action; it is not a direct measurement of food safety.
Serviceable available market — the part of TAM the product could realistically serve given its scope and geography.
A DNA sequencing method often used to verify a cloned sequence or junction.
Successive-approximation analog-to-digital converter — a circuit that samples a voltage and resolves its digital value by successive comparisons.
An early check that identifies samples needing closer attention. A screening result is not a certified safety verdict.
United Nations Sustainable Development Goal — a shared framework for describing social and environmental aims, not proof that an aim has been achieved.
Safety Data Sheet — a supplier document describing chemical hazards, handling, and emergency information for a substance.
In electronics, how strongly a device responds to a small input. In classification, the proportion of true positives correctly detected. The intended meaning needs context.
Spiking neural network — a neural model that communicates with discrete spike events over time.
Signal-to-noise ratio — how large the useful signal is compared with unwanted variation or background.
Serviceable obtainable market — the share a team could plausibly capture within a stated period and sales plan.
Standard operating procedure — an institution-approved written method for performing a task safely and consistently.
A representation strategy in which only a small fraction of units are strongly active for a given input.
In sensing, how selectively a system responds to a target. In classification, the proportion of true negatives correctly identified.
Serial Peripheral Interface — a synchronous serial bus commonly used between a microcontroller and peripherals such as ADCs.
A preprocessing step that centers features and scales them by their training-set standard deviation; it must be fitted without test-set leakage.
Spike-timing-dependent plasticity — a learning rule that changes connection strength based on the timing of neuron-like spikes.
A triangle-mesh file format commonly used to transfer a three-dimensional part to 3D-printing software. A printable model is not evidence of validated fit or function.
Support vector machine — a model that learns a boundary between classes from labeled examples.
The time needed for a response to reach 90% of its final change. Gas-phase, liquid-phase, and biological response times describe different processes.
Total addressable market — the broadest plausible market for a defined product, under stated assumptions.
Transimpedance amplifier — a circuit that converts a small input current into a usable output voltage.
Universal asynchronous receiver-transmitter — a serial data interface. The AeroSense programming connection uses 3.3 V UART; it is separate from USB-C power.
Volatile organic compound — a carbon-containing chemical that readily enters the gas phase at ambient conditions.
Voltage reference — a stable comparison voltage that helps an ADC convert an input signal into numbers.
A synthetic compound used to activate Orco-containing insect odorant-receptor channels; useful as a pathway control.
How much a specified buyer would pay for a defined solution; it must be tested with the actual buyer, not inferred from general interest.
Relative fluorescence change — the change in fluorescence divided by a baseline fluorescence level.