Safety
Laboratory safety, project-specific risk assessment, responsible future applications, and ethics in human engagement.
Overview
Safety is a fundamental responsibility in synthetic biology, essential to protecting researchers, the public, and the environment. The development of new biological systems therefore requires careful consideration of potential risks alongside their intended benefits. In developing dogmaOS, our team incorporated safety considerations throughout the research process, guided by the iGEM Safety Rules and Policies (iGEM Foundation, 2026), the Biosecurity Law of the People’s Republic of China (Standing Committee of the National People’s Congress, 2020), and Xi’an Jiaotong-Liverpool University’s laboratory safety requirements.
This commitment extends from the experimental work needed to develop dogmaOS to the implications of its wider use. Our assessment begins with Laboratory Safety, extends to Project-Specific Safety concerning the engineered system and its environmental impact, looks ahead to Responsible Use and Future Applications, and also addresses Human Engagement Ethics. Within each section, identified risks are discussed alongside corresponding measures, available evidence, and remaining limitations, with implemented practices clearly distinguished from safeguards proposed for future development.
Laboratory Safety
Laboratory Access and Safety Training
The team’s application for laboratory access at Xi’an Jiaotong-Liverpool University was approved. Preparation for laboratory work brought together safety guidance and the practical skills needed to carry out dogmaOS. Dr. Zhongkai Huang led the team’s laboratory safety training, while Dr. Ziwen Xie provided additional guidance during the project.
The experimental work required training in microbial cultivation, strain construction, recombinant protein expression, and protein analysis. Basic laboratory skills included accurate pipetting, aseptic handling, and bacterial cultivation. Strain construction and evaluation involved plasmid preparation, bacterial transformation including electroporation, PCR, gel electrophoresis, and quantitative PCR. Protein studies required recombinant protein expression, cell lysis, preparation of soluble and insoluble protein fractions, SDS-PAGE, and Western blot analysis. Safety training covered the correct use of relevant laboratory equipment, handling of biological and chemical materials, and waste disposal associated with these procedures.
Procedure-specific safety guidance helped team members recognize exposure and contamination risks and identify situations requiring additional supervision or assistance.
Biological and Chemical Materials
Biological and chemical materials require precautions appropriate to their hazards during handling, storage, and disposal. Bacterial cultures, for example, require containment to minimise accidental contact and contamination of the laboratory environment. Used cultures and contaminated consumables must be collected through the laboratory’s biological-waste system.
For chemical materials, precautions depend on their composition, concentration, and intended use. Where a reagent presents skin or eye contact hazards, handling requires the protective measures specified in its safety data sheet. These material-specific requirements also guide labelling, storage, and disposal in accordance with laboratory procedures.
Equipment Safety and Laboratory Practices
Laboratory equipment can introduce mechanical, electrical, and other operational hazards that require appropriate precautions. For example, improperly balanced centrifuge loads or damaged tubes may cause equipment failure or sample leakage, while electrophoresis systems present electrical hazards if handled while powered on. To minimise these risks, centrifuge tubes are inspected and balanced before operation, equipment is kept closed while running, and electrophoresis power supplies are switched off before opening the apparatus.
Beyond these equipment-specific precautions, safe laboratory practices include following established operating procedures, maintaining orderly workspaces, and reporting equipment abnormalities promptly. In the event of accidental spills, equipment malfunctions, or personal exposure, experimental activities should be stopped and the incident reported to the laboratory supervisor for appropriate handling in accordance with laboratory emergency procedures.
| Category | Material / Equipment | Potential Hazards | Safety Precautions |
|---|---|---|---|
| Biological | E. coli DH5α, BL21(DE3), and engineered derivatives | Accidental release of recombinant bacteria and contamination of work areas | Handle cultures in designated laboratory areas; use appropriate containment and biological waste disposal |
| Biological | Recombinant plasmids and antibiotic-resistance markers | Retention or unintended dissemination of engineered genetic elements and resistance genes | Remove unnecessary editing plasmids and selection markers; verify removal and manage recombinant biological waste |
| Biological | Recombinant proteins (G-CSF, human leptin, PfCHT1) | Potential unintended exposure to recombinant protein-containing cultures and lysates during cell disruption and sample processing | Minimise direct contact with cultures and lysates; use appropriate PPE and controlled sample handling |
| Chemical | Antibiotics (ampicillin, kanamycin, spectinomycin) | Potential irritation or sensitisation following exposure; environmental concerns associated with inappropriate disposal | Wear suitable PPE; label and store solutions appropriately; dispose of antibiotic-containing waste according to laboratory procedures |
| Chemical | TRIzol reagent and chloroform | Toxic and irritating; accidental splashes or exposure to vapours may cause skin, eye, or inhalation hazards | Handle in a chemical fume hood; avoid direct contact and inhalation; wear appropriate gloves, lab coat, and eye protection; dispose of waste according to laboratory chemical-waste procedures |
| Chemical | Ethanol, isopropanol, and methanol | Flammable solvents; accidental contact may cause skin or eye irritation | Keep away from ignition sources; use in well-ventilated areas; wear appropriate PPE and store and dispose of solvents according to laboratory procedures |
| Chemical | Antibiotics (ampicillin, kanamycin, spectinomycin) | Potential irritation or sensitisation following exposure; inappropriate disposal may contribute to the environmental release of antimicrobial agents | Wear suitable PPE; label and store solutions appropriately; dispose of antibiotic-containing waste according to laboratory procedures |
| Chemical | IPTG | Potential exposure during solution preparation or handling; may cause irritation depending on concentration and route of exposure | Avoid direct contact and inhalation of powders; wear appropriate PPE and follow reagent-specific safety data sheets |
| Chemical | Agarose gel stain | Potential irritation or other adverse effects following accidental contact, depending on the staining reagent used | Avoid direct contact; wear appropriate gloves and eye protection; handle and dispose of staining solutions according to reagent-specific procedures |
| Chemical | Unpolymerized acrylamide/bis-acrylamide solution | Toxic before polymerization; accidental skin or eye contact may result in harmful exposure | Avoid direct contact with unpolymerized solutions; wear appropriate gloves, lab coat, and eye protection; follow reagent-specific safety data sheets |
| Chemical | SDS, ammonium persulfate (APS), and TEMED | May cause skin or eye irritation; APS is an oxidizing reagent, while other hazards depend on reagent concentration and formulation | Avoid direct contact; wear appropriate PPE; prepare and handle solutions according to reagent-specific safety data sheets |
| Chemical | β-Mercaptoethanol | Toxic and irritating; vapours and accidental skin or eye contact may cause harmful exposure | Handle in a chemical fume hood; avoid inhalation and direct contact; wear appropriate PPE and dispose of waste according to laboratory procedures |
| Chemical | Urea-containing electrophoresis reagents | May cause irritation depending on reagent concentration and formulation | Avoid direct contact; use appropriate gloves and eye protection; follow reagent-specific safety data sheets |
| Chemical | Coomassie Brilliant Blue staining reagents | Potential skin or eye irritation during staining and destaining procedures, depending on formulation | Avoid direct contact; wear appropriate PPE; handle staining and destaining waste according to laboratory chemical-waste procedures |
| Equipment | French press | High-pressure operation may cause sample leakage, splashing, or mechanical injury | Inspect equipment and seals; follow pressure limits and operating procedures; release pressure before opening |
| Equipment | High-speed centrifuges and ultracentrifuges | Rotor imbalance or tube failure may cause mechanical damage, sample leakage, or aerosol generation | Balance samples, inspect rotors and tubes, use compatible containers, and keep equipment secured during operation |
| Equipment | Electroporator | High-voltage pulses may present electrical hazards if equipment is improperly handled | Use compatible electroporation cuvettes and follow the equipment’s electrical safety procedures |
| Equipment | Electrophoresis and Western blot transfer systems | Electrical shock from powered equipment and potential exposure to electrophoresis buffers | Switch off power before accessing gels or buffers; inspect electrical connections and follow established operating procedures |
The table summarizes representative biological materials, chemical reagents, and laboratory equipment used in the project, highlighting their potential hazards and corresponding safety precautions. The selection focuses on key safety concerns rather than providing an exhaustive inventory of all materials and equipment.
Project-Specific Safety
Genetic Engineering and Host Modification
Genome editing in dogmaOS involved auxiliary plasmids and antibiotic-resistance markers, whose retention after editing could leave unnecessary resistance determinants and genome-editing machinery in the final engineered chassis.
To minimise these risks, the chromosomal kanamycin-resistance cassette introduced during alaXW promoter replacement was excised, and the helper plasmids pSIM6 and pCP20 were subsequently cured. Similarly, pEcCas and pEcgRNA were removed following proL promoter modification. These removal steps, verified by antibiotic-resistance screening and plasmid-specific PCR, reduced the retention of editing-related genetic elements in the final chassis, while the corresponding chromosomal modifications were confirmed by PCR and sequencing.
Beyond the removal of editing-related genetic elements, engineering the host tRNA pool introduces an additional project-specific consideration. Because tRNAs participate in the translation of both recombinant and endogenous proteins, altering their availability may affect host physiology beyond the intended target protein (Hanson & Coller, 2018). To assess whether our tRNA-pool engineering caused an obvious growth defect, we compared the growth profiles of the engineered and control strains. Under the tested conditions, the engineered strains showed growth patterns comparable to the control, suggesting that the modifications did not cause a major impairment in cellular growth. However, normal growth alone does not exclude more subtle physiological effects, which would require further characterization.
Recombinant Protein Safety
The recombinant proteins expressed in dogmaOS include G-CSF and human leptin, which have physiological signalling functions, and PfCHT1, a chitinase derived from Plasmodium falciparum. Their biological functions and origins were considered when assessing potential risks associated with unintended exposure during recombinant expression, cell disruption, and sample processing.
For PfCHT1, our experiments involved recombinant expression in E. coli rather than cultivation of the malaria parasite itself. Protein-containing samples were handled according to the biological-material safety precautions described under Laboratory Safety, with particular attention to preventing accidental contact during sample processing.
Environmental Release and Genetic Dissemination
The use of engineered E. coli and recombinant expression plasmids in dogmaOS also raises concerns about accidental environmental release. If recombinant bacteria or plasmid-containing materials escape laboratory containment, they could introduce engineered genetic elements, including antibiotic-resistance markers carried by expression plasmids, into the surrounding environment, creating potential opportunities for genetic dissemination.
To prevent unintended release, engineered strains were handled within designated laboratory areas, while cultures and contaminated materials were managed through established biological waste-disposal procedures. These measures focused on maintaining containment throughout recombinant protein production and preventing the uncontrolled release of engineered biological materials.
Responsible Use and Future Applications
Transferability and Potential Misuse
In its current implementation, dogmaOS was developed using laboratory strains of E. coli, with biosafety measures tailored to the genetic modifications and recombinant proteins involved. While the identified risks are managed within this controlled experimental setting, the same safety considerations may not apply when the approach is transferred to other biological systems.
A key feature of dogmaOS is the combination of synonymous codon optimization with host tRNA-pool engineering. Since tRNA availability influences the translation of both recombinant and endogenous proteins (Hanson & Coller, 2018), applying this strategy to different microbial chassis could produce host-dependent effects. Differences in genetic background, pathogenic potential, and environmental adaptability may further alter the associated biosafety risks. In addition, the potential use of this expression-optimization approach for producing biologically hazardous proteins raises dual-use concerns. Therefore, the safety profile of dogmaOS should be considered in the context of each application rather than assumed to remain unchanged across different hosts and target proteins.
For future applications, the host organism, target protein, proposed use, and relevant genetic modifications should therefore be reviewed before implementation. Applications involving organisms with increased pathogenic or environmental persistence, or target proteins associated with significant biological hazards, would require additional institutional and regulatory assessment. These safeguards represent considerations for future implementation rather than measures validated in the current project.
Responsible Industrial Scale-Up
Scaling dogmaOS from laboratory experiments to industrial recombinant protein production would introduce additional biosafety considerations associated with larger volumes of engineered E. coli cultures and increased material handling. Operations such as culture transfer, harvesting, and downstream processing could increase opportunities for accidental spills, aerosol generation, and exposure to recombinant biological materials.
To address these risks, future large-scale applications should incorporate appropriate containment systems, controlled material-transfer procedures, and measures to prevent unintended environmental release. The increased volume of biological waste and process effluents would also require validated inactivation procedures before disposal. These measures would help ensure that the expansion of recombinant protein production is accompanied by safety controls appropriate to the production scale. However, they represent considerations for future implementation and have not been validated at industrial scale in the current project.
Human Engagement Ethics
Our Human Practices and Education activities included surveys, interviews, discussions, and public engagement with different stakeholder groups. Because these activities involved human participants, we treated ethical oversight and participant protection as part of our safety responsibilities.
All questionnaires and organized public-engagement activities underwent the relevant ethical review and approval procedures at Xi’an Jiaotong-Liverpool University before implementation. Participation was based on voluntary involvement and informed consent. Before each activity, participants were informed of its purpose, what participation involved, how their information would be used, and their right to decline questions or withdraw from participation.
We followed a data-minimisation principle, collecting only the information necessary for each activity. Survey responses and feedback materials were anonymised or de-identified wherever possible, and access to raw materials was limited to appropriate team members. Names, affiliations, direct quotations, photographs, or other identifiable information were only included in Wiki pages, presentations, or other project materials after obtaining explicit permission from the participants concerned. iGEM similarly recommends anonymising Human Practices data unless specific permission has been obtained to identify an individual (iGEM Foundation, n.d.).
For activities involving minors, the necessary school and/or guardian permissions were obtained, and activities were conducted under appropriate supervision. For older participants, information was presented in a clear and accessible manner, participation remained voluntary and non-coercive, and additional assistance was provided where needed.
These measures ensured that our engagement activities were conducted with appropriate ethical oversight, informed participation, privacy protection, and additional consideration for participants requiring greater protection. They also allowed us to use stakeholder feedback responsibly while respecting the rights, privacy, and autonomy of the people who contributed to our project.
References
Hanson, G., & Coller, J. (2018). Codon optimality, bias and usage in translation and mRNA decay. Nature Reviews Molecular Cell Biology, 19(1), 20–30. https://doi.org/10.1038/nrm.2017.91
iGEM Foundation. (2026). Rules & policies. https://competition.igem.org/about/rules-and-policies
iGEM Foundation. (n.d.). Informed consent. https://responsibility.igem.org/guidance/informed-consent
Standing Committee of the National People’s Congress. (2020). Biosecurity Law of the People’s Republic of China. https://www.mee.gov.cn/ywgz/fgbz/fl/202303/t20230314_1019536.shtml