A TROP2-binding nanobody conjugated to the vesicle surface through a PEG linker, so that vesicles bind cells displaying TROP2.
PENN STATE iGEM 2026
Developing TRIDENT required a systematic approach to engineering a targeted extracellular vesicle delivery platform. Through the Design–Build–Test–Learn cycle, we investigated each stage of development, from vesicle isolation and surface functionalization to genetic cargo loading and cell-based evaluation. This page documents our engineering decisions, experimental challenges, and troubleshooting efforts, highlighting how our findings informed improvements to our methods and our understanding of the platform.
TRIDENT is a platform using yeast-derived extracellular vesicles (EVs; yEVs for the yeast-derived preparation) to investigate targeted nucleic-acid delivery. A miR-34a-expressing plasmid is one cargo format. Cell-culture viability differences motivate further work, but do not alone establish TROP2-dependent uptake, miR-34a target silencing, or safety in healthy tissue.
miR-34a is a well-studied tumor suppressor that represses survival genes such as BCL2, but delivering it safely has been difficult. A good delivery vehicle must do two things: carry viable nucleic acid cargo intact into cells, and reach cancer cells but not healthy ones. Our design question was whether a yeast-derived vesicle, decorated with a TROP2-binding nanobody, could do both.
miR-34a is an endogenous regulatory RNA; the plasmid carrying its expression sequence is an engineered construct. Our contribution is to combine that cargo with a targeted delivery platform and compare cellular readouts with other treatment conditions. The cargo and targeting ligand are intended to be independently replaceable modules.
We designed a vesicle-based delivery system with three functional modules:
A TROP2-binding nanobody conjugated to the vesicle surface through a PEG linker, so that vesicles bind cells displaying TROP2.
Yeast-derived EVs are investigated as a potentially scalable delivery chassis. Their compatibility, loading efficiency, and safety relative to mammalian EVs or liposomes require formulation-specific comparisons.
A miR-34a expression plasmid is used in the EV preparation. Intravesicular encapsulation, the duration of miR-34a expression, and cancer-specific effects require independent measurements.
We chose yeast as the vesicle source because it is inexpensive to culture and scale. We chose protein binding as the targeting mechanism so that retargeting means changing only one component: the nanobody. We chose a plasmid over a synthetic mimic because a plasmid is transcribed continuously, while a mimic is a finite dose that dilutes and degrades. We expected the plasmid to sustain miR-34a expression and so produce a more powerful apoptotic response — which is what we went on to observe in our flow cytometry data.
We isolated yEVs from yeast culture media using tangential flow filtration.
We conjugated the TROP2-binding nanobody to the PEG linker as a means to increase surface area and control orientation.
We then loaded vesicles with the miR-34a plasmid and the TROP2-PEG conjugate using ExoFect, and purified using one last round of ultracentrifugation.
We confirmed what we had built before using it:
Our first purification approach to removing excess TROP2-PEG conjugate molecules was size exclusion, but it left vesicles in the retentate and did not remove excess unconjugated TROP2 as intended. This was determined using a NanoDrop spectrophotometer. We then switched to ultracentrifugation.
We tested in two stages, ordered so that a cheap experiment answered a critical question before we spent on expensive ones.
Before testing cell viability, we assessed reporter expression in HEK293 cells in an 8-well format with 1, 2, or 3 µL of undecorated (TROP2-free) EV preparations containing an EGFP/miR-34a plasmid and Texas Red siRNA; cells-only wells were the negative control. Texas Red fluorescence reports the presence or localization of the label associated with the siRNA preparation (TR-siRNA). siRNA is not translated into protein. This signal alone does not establish EV-mediated uptake, cytosolic release, RISC activity, gene silencing, or functional knockdown. EGFP fluorescence is consistent with transcription of the reporter DNA and translation of EGFP mRNA. Treated cells showed both signals; free-label, free-cargo, and localization controls are needed to interpret delivery.
| Timepoint | Observation |
|---|---|
| 12 hours | Green fluorescence is consistent with EGFP reporter expression. Texas Red-labeled material is detectable at the earliest timepoint; its location and functional delivery are not established by this signal alone. |
| 40 hours | Green signal is brighter and more widespread in the same wells, consistent with increasing reporter expression; uptake kinetics were not independently measured. |
We treated BxPC-3 (TROP2-high, the target line) and PANC-1 (TROP2-low, the specificity control) and measured apoptosis by Annexin V-APC / SYTOX Blue flow cytometry at 100 h.
Flow legend. Annexin V reports phosphatidylserine exposure (APC, red) | SYTOX reports loss of membrane integrity | double positive is compatible with late apoptosis or other membrane-compromised states | FITC = green.
Stage 1 produced EGFP fluorescence consistent with reporter expression. In Stage 2, plasmid-loaded TROP2 vesicles reduced BxPC-3 viability from 98.8% to 30.4%, and mimic-loaded TROP2 vesicles reduced it to 47.1%. These observations do not establish the delivery route or miR-34a-specific target silencing.
The same mimic-loaded TROP2 preparation lowered viability by about 52 points in BxPC-3 and about 6 points in PANC-1, roughly a 9-fold difference. This cell-line difference is consistent with the targeting hypothesis but is not a direct test of TROP2 dependence or carrier safety. Receptor-blocking and matched ligand-free, cargo-free, and free-cargo controls are needed.
Lipofected mimic reduced viability in both cell lines. Existing narrative values for PANC-1 conflict with the Results summary table and require reconciliation before quantitative comparison. Annexin V/SYTOX patterns alone do not identify lipid-reagent toxicity or establish a specific cell-death mechanism.
The BxPC-3 versus PANC-1 contrast motivates further targeting studies. A PEG linker is intended to present the nanobody on the EV surface; outward orientation and ligand density cannot be inferred from viability or fluorescence alone.
In BxPC-3, the plasmid condition had lower recorded viability than the mimic condition (30.4% vs 47.1% alive). Sustained miR-34a expression is one untested explanation. Loss of Texas Red signal relative to EGFP does not compare RNA activity or persistence: the labels and biological readouts are different.
Early apoptosis was under 1% at the 100 h endpoint. That observation does not establish prior progression through apoptosis; earlier, repeated measurements would be needed to resolve the time course.
The Build stage above depends on tangential flow filtration (TFF) to concentrate our vesicles. To make that step work for us, we also engineered a piece of hardware: a 3D-printed adapter that lets two TFF filters run in tandem.
Full hardware page →Within microbiology and synthetic biology, the use of Tangential Flow Filtration (TFF) is an important tool used for the isolation of biological material from buffer, media components, and other waste particles. This was particularly important for the isolation of yeast EVs. With issues like proteins released in the multicellular vesicle as well as existing proteins and other waste in the media, these particles become contaminants that can bind to the lipid layer of the EVs we used as a delivery system. As such, the way we prevented this was by combining two different-sized filters together to allow for better filtering and removal of proteins. However, without support between biotech companies, and with overly expensive stands for one filter, our team was forced to find a different approach to the solution. By utilizing the quick prototyping capabilities of 3D printing, our team was able to design a part that would allow two TFF filters to work in tandem and be connected in a simple and efficient way. As a team, we tested the system and had great success, and as a 3D-printed part, it is both easily accessible as a 3D file and can be printed on an entry-level 3D printer, allowing teams to connect these two specific filter types together.
The DBTL cycle for our TFF adapter
Select a stage to read what it involved, or use the cycle button in the middle to step through them in order.
Combining two different-sized filters allowed for better filtering and removal of proteins, but there was no off-the-shelf way to join them: stands sold for a single filter were overly expensive, and there was no support between biotech companies. Using the quick prototyping capabilities of 3D printing, our team designed a part that would allow two TFF filters to work in tandem and be connected in a simple and efficient way.
The adapter is a 3D-printed part, so building it does not require specialized manufacturing. It can be printed on an entry-level 3D printer.
As a team, we tested the system and had great success. Running the two different-sized filters together allowed for better filtering and removal of the proteins and other waste that would otherwise bind to the lipid layer of our EVs.
Because the adapter exists as a 3D file, it is easily accessible and can be printed by anyone with an entry-level 3D printer, allowing other teams to connect these two specific filter types together.