To evaluate TRIDENT's potential as a targeted therapeutic delivery platform, we designed a series of experiments investigating the characteristics, delivery capabilities, and biological effects of engineered yeast-derived extracellular vesicles. Our experimental workflow encompassed vesicle isolation and characterization, surface functionalization, and genetic cargo loading, followed by fluorescence imaging, flow cytometry, and scratch assays to assess reporter expression and cellular responses. This page outlines our experimental designs, methodologies, and controls, highlighting the procedures used to evaluate TRIDENT's performance and the challenges encountered throughout testing.

Experimental Design


The three experiments below follow one logical flow. We first establish what we are delivering (how many vesicles, what size, and whether they are intact), then assess reporter expression in recipient cells, and finally test whether targeted delivery kills cancer cells selectively. Each stage uses the output of the one before it, so a failure at an early step stops the work before it reaches the more expensive biology.

Experiment One

NTA & Cryo Experiments

Count and characterize the EVs.


Every downstream result depends on dose, and dose depends on how many vesicles we have. Protein concentration is a poor proxy for particle number in engineered preparations, because potential inclusion of protein and lipid aggregates collected alongside EVs during isolation would contribute mass without adding vesicles. We therefore quantify particles directly by nanoparticle tracking analysis (NTA), which reports particles per milliliter and the size distribution. Yeast EVs are expected to fall within roughly 50 to 300 nm, and a preparation is accepted when its mode lies in that range and at least 5 × 10¹¹ particles are recovered in total.

The documented protocol specifies at least five 60-second videos taken within the instrument's linear counting range, with camera and threshold settings recorded so runs can be compared. A media blank and a PBS blank are run alongside every sample, and counts are reported after blank subtraction. The media blank must be no more than 5% of the sample count; if it is higher, the sample is re-prepared rather than corrected. Total protein is measured by micro-BCA so that a particle-to-protein ratio can be reported as particles per microgram, with a target of at least 1 × 10¹⁰ particles per µg.

Nanoparticle tracking analysis: particle diameter plotted against particle count
NTA size distribution — particle diameter against particle count.

NTA counts alone do not establish membrane-bound vesicles. Electron microscopy can provide evidence of bilayer-delimited particles in sampled fields. Negative staining can introduce cup-shaped artifacts; cryo-EM preserves hydrated morphology more faithfully. DLS and zeta potential, if performed, characterize hydrodynamic size and surface charge rather than independently verifying membrane structure. None of these measurements demonstrates endosomal biogenesis, EV purity, or cargo encapsulation.

Cryo-electron micrograph of Po1f yeast extracellular vesicles Cryo-electron micrograph of yeast extracellular vesicles, foil hole field of view
Cryo-EM of the isolated vesicles, showing bilayered morphology.
Experiment Two

Preliminary EGFP Experiment

Assess EGFP reporter expression after treatment with EV preparations.


Uptake alone does not show functional cargo delivery. This assay asks whether treated HEK293 cells express the plasmid-associated EGFP reporter. Green fluorescence is consistent with reporter expression, which involves transcription of DNA and translation of EGFP mRNA, not translation of siRNA or DNA. Texas Red siRNA is a separate fluorescence readout for labeled material; it does not establish cytosolic delivery or gene silencing.

HEK293 cells were chosen because they are widely used for transfection and reporter assays. Their altered p53 signaling does not make them immune to miR-34a effects: p53-independent responses are possible. This experiment assesses reporter expression; viability and specificity require separate measurements.

Plate layout for the preliminary EGFP delivery experiment
Experimental design for the preliminary EGFP delivery experiment.

The design uses 10,000 cells per well with three volumes of EVs (1, 2, and 3 µL per well), alongside cells-only wells as the negative control. EVs were untargeted for this round, carrying no TROP2 nanobody, so the question was whether the vesicles get into cells at all. Images were taken at 12 hours and again at 40 hours to separate early uptake from accumulating expression. Each condition is repeated across two biological replicates before a difference between volumes is treated as real.

Experiment Three

Final Well Plates & Scratch Assay

Assess cell-line responses and gap closure after treatment.


This is the test that matters most for the project, because it asks whether TROP2 targeting and the miR-34a payload together kill cancer cells while sparing healthy ones. Two cell lines are used in 24-well plates: BxPC-3, which is TROP2-high and serves as the target; PANC-1, which is TROP2-low and serves as a specificity control. Before any treatment, each line's TROP2 level is verified by flow cytometry.

Well plate layout, first half Well plate layout, second half
Plate layout for the final treatment arms.

Cells are seeded to reach about 20% confluence at treatment and 80 to 85% at harvest, and the plate is re-inverted between halves to prevent the uneven seeding that otherwise produces apparent treatment effects. Treatment begins 24 hours after seeding. EVs are dosed by particle number, never by protein, at a fixed ratio of about 1 × 10⁴ particles per cell, with a dose-response series of 1 × 10⁹, 5 × 10⁹, 2.5 × 10¹⁰, and 5 × 10¹⁰ particles per mL read at 24, 48, and 72 hours, with 48 hours as the primary timepoint. Arms carrying the nanobody are matched on surface display intensity to within about 20%, because coupling efficiency varies between lots and equal mass does not guarantee equal targeting density.

Two comparisons separate the mechanisms. Matched arms with and without the TROP2 nanobody show whether targeting, rather than the vesicle itself, drives any effect. The Lipofectamine-delivered miR-34a mimic, scrambled mimic, and plasmid arms provide a ceiling and a sequence-specific control, so an apoptosis signal can be attributed to the payload and not to lipid toxicity. The Lipofectamine arms are used as the reference for maximum achievable delivery.

Apoptosis is read by flow cytometry using Annexin V-APC with PI or SYTOX Blue. Apoptotic cells detach, so the medium and PBS wash are collected with the attached cells for every well, and detachment uses EDTA-free Accutase so that it does not strip surface-bound EVs or cause false Annexin V positives. Staurosporine at 1 µM serves as the positive apoptosis control, and the gate is set against it. Each group is pooled from three wells into a single tube, which makes n = 1 per group on any one day, so statistics come from repeating the entire run on separate days for three biological replicates. Annexin V-APC is used instead of FITC because the plasmid arms express EGFP, and the tracer labeling would otherwise interfere with the readout.

Scratch assay design showing the insert wall and the cell-free gap
Scratch assay design: cells seeded on either side of a removable wall.

The scratch assay measures how well each cell population heals a wound in vitro, which serves as a readout of proliferation and growth. Cells are seeded on each side of a thin wall inserted into the well, so each well starts as two confluent sections. Once the cells are confluent, the wall is removed, leaving a defined cell-free gap. The wells are then imaged at 6-hour intervals from the moment of removal, and the gap area at each timepoint is measured. The rate and extent of gap closure show how quickly each arm's cells repopulate the empty space. Comparing these curves across 6 wells of PANC-1, with 3 untreated and 3 treated with TROP2-decorated, miR-34a-loaded EVs, tests whether the engineered EVs slow growth in the target cells. Because gap closure reflects both proliferation and cell migration, the assay is most informative when contextualized with the Annexin V apoptosis data. A slowed closure that coincides with rising apoptosis points to cell death, while slowed closure without apoptosis points to a growth arrest. Either one suggests the prevention of metastasis.

See our results →

Challenges & Troubleshooting


We did not have adequate funding for some of the materials we needed, so we reached out to companies offering them access to our data. Because we were using many of the materials for novel applications, applying them to yeast EV isolation, we were able to provide them with the opportunity to explore and validate novel applications for products they already had, potentially expanding their market without any further R&D on their end.

For our first 8-well experiment, we initially intended to choose a cell line with functional p53. However, upon further consideration, we realized that a p53-negative cell line would offer a better test of delivery, as a culture with functional p53 may see an increase in apoptosis preferentially in the cells that had effective plasmid delivery. This would kill the most EGFP-expressive portion of the population, skewing the data towards lower expression despite effective delivery. For the sake of scientific rigor and clarity of results, we elected to use HEK293, which is immortalized by disabling the p53 pathway.

During post-engineering purification for the final experiment, we initially tested size exclusion as our method for removing excess TROP2 after loading. However, this presented challenges, as the filter size was too small and left the EVs in the retentate, and any gel size-exclusion we could perform would present the same trade-off, so we went with ultracentrifugation instead.

Protocols Handbook